Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 Wireless I/O Module WM11 Datasheet OVERVIEW The WM11 provides long-distance wireless connectivity to reduce the cost of wiring sensors and equipment in hard to reach places. With a range of over 300m in open-air settings, the built-in analog and digital IO capture and transmit data directly to the Samsara IG41 Industrial Controller where it is automatically uploaded to the Samsara cloud. The WM11 is battery powered, IP66-rated, and mounts easily on industrial equipment for rapid deployment. Lower costs and save time by elminating wiring, and bring visibility to industrial equipment no matter the location. HIGHLIGHTS Long range wireless 300m+ open air range for industry-standard analog and digital sensors Analog & digital IO Connects up to 4 analog inputs, 1 digital input, 1 digital output Ruggedized Rugged, IP66-rated enclosure Low power Low power consumption with consumption field replaceable batteries or optional external power TENTATIVE 2 WM11 Wireless Module ENCLOSURE Dimensions (WxHxD) 93mm x 124mm x 65mm Weight 400 g Mounting Four mounting ears, M5 (#10) ENVIRONMENTAL Operating temperature -40°C to +75°C (-40°F to +167°F) Storage temperature -40°C to +85°C (-40°F to +185°F) Operating humidity 10% RH to 90% RH, noncondensing Ingress protection IP66 POWER Battery life 2 years with 1 poll per hour Batteries Two 3.6-V 2500-mAH lithium AA batteries External power (optional) 9 ~ 36 VDC SHOCK & VIBRATION Free fall IEC 60068-2-32 Operating shock IEC 60068-2-27 Operating vibration IEC 60068-2-6 CONNECTIVITY Protocol LoRaWAN Range 300m+ in open air Polling interval Configurable from 20s to one day TENTATIVE 3 WM11 Wireless Module ANALOG INPUTS Number of inputs 4 Configuration 2 AI voltage, 2 AI current Input range 0-10V, 0-20mA Resolution 16 bit Input load resistance 10 MΩ (voltage), 120 Ω (current) Accuracy ±0.1% (Voltage) at 25 °C ±0.2% (Current) at 25 °C” DIGITAL INPUTS Number of inputs 1 Voltage range Dry contact : Logic level 0: close to GND, Logic level 1: open Wet contact : Logic level 0: 0 ~ 1 VDC, Logic level 1: 3 ~ 30 VDC Pull-up current 32 μA Input high voltage 2.0 V min Input low voltage 0.8 V max Isolation None Channels 2ch DIGITAL OUTPUTS Number of outputs 1 Voltage range 0-30 V Output type Open drain Output current 100 mA max Protection Current limit protection Isolation None TENTATIVE 4 WM11 Wireless Module SAFETY, HAZARDOUS LOCATIONS, & COMPLIANCE* Hazardous locations US (UL) • Class I, Division 2, Groups A, B, C, D, T4 • Class I, Zone 2, AEx nA IIC T4 Electromagnetic compatibility • FCC 47 CFR Part 15B, Class A • ICES-003:2016 Issue 6 (ITE) Class A • ANSI C63.4:2014 • EN 61000-4-2:2009 / IEC 61000-4-2:2008 ED. 2.0 • EN 61000-4-3:2006 +A1:2008 +A2:2010 / IEC 61000-4-3:2010 ED. 3.2 • EN 61000-4-4:2012 / IEC 61000-4-4:2012 ED. 3.0 • EN 61000-4-5:2014 +A1:2017 / IEC 61000-4-5:2014 +A1:2017 ED. 3.0 • EN 61000-4-6:2014 +AC:2015 / IEC 61000-4-6:2013 ED. 4.0 • EN 61000-4-8:2010 / IEC 61000-4-8:2009 ED. 2.0 Note: In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intended for use only in heavy-industrial locations. *pending certification TENTATIVE 5 WM11 Wireless Module FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. IMPORTANT NOTE FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. TENTATIVE
Confidentiality Request Letter Date: Sep. 29, 2020 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request FCC ID: 2AIHD1014 To Whom It May Concern: Pursuant to Sections 0.457 and 0.459 of the Commission’s rules, we hereby request confidential treatment for the following attachments to this application as outlined below: ☒ Block Diagram ☒ Schematics ☒ Theory of Operation The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Further, pursuant to DA 04-1705 of the Commission’s public notice, in order to comply with the marketing regulations in 47CFR §2.803 and the importation rules in 47 CFR §2.1204 while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we are requesting the commission to grant short-term confidentiality request on the following attachments until 180 days after the grant date: ☒ Internal Photographs ☒ External Photographs ☒ User Manual ☒ Test Setup Photographs The applicant understands that pursuant to Section 0.457 of the rules, disclosure of this application and all accompanying documentation will not be made prior to the grant of equipment authorization. Signature: Benjamin Calderon Executive Vice President, Hardware Engineering and Operations Samsara Network, Inc. 1990 Alameda Street, San Francisco, CA 94103 Tel: +1 (415) 985-2400 Email: [email protected] DocuSign Envelope ID: DBFEC014-3931-4C3F-A472-DEBD9B5A17AC 10/5/2020
Letter of Authorization Date: Oct. 26, 2020 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, Samsara Networks, Inc., hereby authorize the following person to act on our behalf in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (“BV CPS Taoyuan”) Address:No.19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City, Taiwan (R.O.C.) Name:Andrea Hsia Job Title:Supervisor E-mail:[email protected] This authorization is applicable to the following products: FCC ID: 2AIHD1014 Product(s): ACC-WM11 Signature: Benjamin Calderon Executive Vice President, Hardware Engineering and Operations Samsara Network, Inc. 1990 Alameda Street, San Francisco, CA 94103 Tel: +1 (415) 985-2400 Email: [email protected] DocuSign Envelope ID: 22C16FEE-D177-4DDC-860D-71254CA3C547
Reference No.: BEAD-WTW-P20080101 Page 1 / 6 CONSTRUCTION PHOTOS OF EUT Model: ACC-WM11 Reference No.: BEAD-WTW-P20080101 Page 2 / 6 Reference No.: BEAD-WTW-P20080101 Page 3 / 6 Reference No.: BEAD-WTW-P20080101 Page 4 / 6 Model: BB-WSW2C00015-1 Reference No.: BEAD-WTW-P20080101 Page 5 / 6 Reference No.: BEAD-WTW-P20080101 Page 6 / 6
Label location will be in side of device
Reference No.: BEAD-WTW-P20080101 Page 1 / 10 CONSTRUCTION PHOTOS OF EUT Model: ACC-WM11 Reference No.: BEAD-WTW-P20080101 Page 2 / 10 Reference No.: BEAD-WTW-P20080101 Page 3 / 10 Reference No.: BEAD-WTW-P20080101 Page 4 / 10 Reference No.: BEAD-WTW-P20080101 Page 5 / 10 Reference No.: BEAD-WTW-P20080101 Page 6 / 10 Reference No.: BEAD-WTW-P20080101 Page 7 / 10 Model: BB-WSW2C00015-1 Reference No.: BEAD-WTW-P20080101 Page 8 / 10 Reference No.: BEAD-WTW-P20080101 Page 9 / 10 Reference No.: BEAD-WTW-P20080101 Page 10 / 10
Report No.: SABEAD-WTW-P20080101 Page No. 1 / 5 Report Format Version: 6.1.1 RF Exposure Report Report No.: SABEAD-WTW-P20080101 FCC ID: 2AIHD1014 Test Model: ACC-WM11 Received Date: Aug. 06, 2020 Date of Evaluation: Sep. 01, 2020 Issued Date: Sep. 03, 2020 Applicant: Samsara Networks Inc. Address: 1990 Alameda Street, San Francisco, CA 94103 Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, TAIWAN FCC Registration / Designation Number: 788550 / TW0003 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. Report No.: SABEAD-WTW-P20080101 Page No. 2 / 5 Report Format Version: 6.1.1 Table of Contents Release Control Record .................................................................................................................................. 3 1 Certificate of Conformity ...................................................................................................................... 4 2 RF Exposure .......................................................................................................................................... 5 2.1 Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5 2.2 MPE Calculation Formula ................................................................................................................... 5 2.3 Classification ....................................................................................................................................... 5 2.4 Calculation Result of Maximum Conducted Power ............................................................................. 5 Report No.: SABEAD-WTW-P20080101 Page No. 3 / 5 Report Format Version: 6.1.1 Release Control Record Issue No. Description Date Issued SABEAD-WTW-P20080101 Original Release Sep. 03, 2020 Report No.: SABEAD-WTW-P20080101 Page No. 4 / 5 Report Format Version: 6.1.1 1 Certificate of Conformity Product: Industrial LoRaWAN node Brand: Samsara Test Model: ACC-WM11 Sample Status: Engineering Sample Applicant: Samsara Networks Inc. Date of Evaluation: Sep. 01, 2020 Standards: FCC Part 2 (Section 2.1091) References Test Guidance : KDB 447498 D01 General RF Exposure Guidance v06 IEEE C95.3 -2002 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s RF characteristics under the conditions specified in this report. Prepared by : , Date: Sep. 03, 2020 Shelly Hsueh / Specialist Approved by : , Date: Sep. 03, 2020 Dylan Chiou / Senior Project Engineer Report No.: SABEAD-WTW-P20080101 Page No. 5 / 5 Report Format Version: 6.1.1 2 RF Exposure 2.1 Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (minutes) Limits For General Population / Uncontrolled Exposure 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f 2 )* 30 30-300 27.5 0.073 0.2 30 300-1500 ... ... f/1500 30 1500-100,000 ... ... 1.0 30 f = Frequency in MHz ; *Plane-wave equivalent power density 2.2 MPE Calculation Formula Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale pi = 3.1416 r = distance between observation point and center of the radiator in cm 2.3 Classification The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. 2.4 Calculation Result of Maximum Conducted Power Band Frequency Band (MHz) Max Power (dBm) Antenna Gain (dBi) Distance (cm) Power Density (mW/cm 2 ) Limit (mW/cm 2 ) LoRaWAN 902.3~914.9 18.87 2.01 20 0.024 0.60 Note: 1. Determining compliance based on the results of the compliance measurement, not taking into account measurement instrumentation uncertainty. 2. The above Antenna information is declared by manufacturer and for more detailed features description, please refer to the manufacturer's specifications, the laboratory shall not be held responsible Therefore the maximum calculations of above situations are less than the “1” limit. --- END ---
Report No.: RFBEAD-WTW-P20080101 Page No. 1 / 47 Report Format Version: 6.1.1 FCC Test Report Report No.: RFBEAD-WTW-P20080101 FCC ID: 2AIHD1014 Test Model: ACC-WM11 Received Date: Aug. 06, 2020 Test Date: Aug. 14, 2020 ~ Aug. 26, 2020 Issued Date: Sep. 03, 2020 Applicant: Samsara Networks Inc. Address: 1990 Alameda Street, San Francisco, CA 94103 Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, Taiwan FCC Registration / Designation Number: 788550 / TW0003 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. Report No.: RFBEAD-WTW-P20080101 Page No. 2 / 47 Report Format Version: 6.1.1 Table of Contents Release Control Record .................................................................................................................................. 4 1 Certificate of Conformity ...................................................................................................................... 5 2 Summary of Test Results ..................................................................................................................... 6 2.1 Measurement Uncertainty ................................................................................................................... 6 2.2 Modification Record ............................................................................................................................ 6 3 General Information .............................................................................................................................. 7 3.1 General Description of EUT ................................................................................................................ 7 3.2 Description of Test Modes ................................................................................................................... 8 3.2.1 Test Mode Applicability and Tested Channel Detail ............................................................................. 9 3.3 Description of Support Units ............................................................................................................. 10 3.3.1 Configuration of System under Test .................................................................................................. 10 3.4 General Description of Applied Standards and references ................................................................ 11 4 Test Types and Results ...................................................................................................................... 12 4.1 Radiated Emission and Bandedge Measurement ............................................................................. 12 4.1.1 Limits of Radiated Emission and Bandedge Measurement .............................................................. 12 4.1.2 Test Instruments ................................................................................................................................ 13 4.1.3 Test Procedures ................................................................................................................................. 14 4.1.4 Deviation from Test Standard ............................................................................................................ 14 4.1.5 Test Setup .......................................................................................................................................... 15 4.1.6 EUT Operating Conditions ................................................................................................................. 16 4.1.7 Test Results ....................................................................................................................................... 17 4.2 Conducted Emission Measurement .................................................................................................. 32 4.2.1 Limits of Conducted Emission Measurement .................................................................................... 32 4.2.2 Test Instruments ................................................................................................................................ 32 4.2.3 Test Procedures ................................................................................................................................. 32 4.2.4 Deviation from Test Standard ............................................................................................................ 33 4.2.5 Test Setup ...................................................................................................................................…
Text truncated - open the document above for the full version.
Reference No.: RFBEAD-WTW-P20080101 Page No. 1 / 4 PHOTOGRAPHS OF THE TEST CONFIGURATION Conducted Emission Test (Test Mode B) Reference No.: RFBEAD-WTW-P20080101 Page No. 2 / 4 Radiated Emission Test <Frequency Range below 1GHz> (Test Mode A) Reference No.: RFBEAD-WTW-P20080101 Page No. 3 / 4 Radiated Emission Test <Frequency Range below 1GHz> (Test Mode B) Reference No.: RFBEAD-WTW-P20080101 Page No. 4 / 4 Radiated Emission Test <Frequency Range above 1GHz> (Test Mode A)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.3 MHz - 914.9 MHz | 77.00 mW |
Worker Safety Wearable
Equipment Class
UWB - Ultra Wideband TransmitterVehicle Gateway
Equipment Class
DTS - Digital Transmission System
HW-IG41
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Vehicle Gateway
Equipment Class
NII - Unlicensed National Information Infrastructure TX
AG46
Equipment Class
PCB - PCS Licensed Transmitter