2AIT9-PG-108Alarm Host

SZ PGST CO., LTD

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Jan 16, 2024
Application Purpose
Original Equipment
Date of Application
Jan 16, 2024
Equipment Note
Alarm Host
Frequency Range
1850.20000000 - 1909.80000000
Company
SZ PGST CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

Cover Letter(s)

↗

External Photos

ID Label/Location Info

Internal Photos

RF Exposure Info

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Task Status Keyboard lock status FCC Warnning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: ЬReorient or relocate the receiving antenna. ЬIncrease the separation between the equipment and receiver. ЬConnect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Test Report

1. Antenna Description: Antenna type Spring Antenna Model PG-108-GPRS Manufacturer SZ PGST Co., Ltd Gain (869 MHz -894MHz):1dBi (1930 MHz -1990MHz) :1dBi 2. Antenna Photo: Length: 27.25mm Width: 4.04mm

Test Report

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China FCC PART 22/24 TEST REPORT FCC Part 22 /Part 24 Report Reference No. .....................: FCC ID. .............................................: CTA24010301204 2AIT9-PG-108 Compiled by ( position+printed name+signature) .. : File administrators Zoey Cao Supervised by ( position+printed name+signature) .. : Project Engineer Amy Wen Approved by ( position+printed name+signature) .. : RF Manager Eric Wang Date of issue ..................................... : Jan. 11, 2024 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ............................ : SZ PGST Co., Ltd Address ............................................ : No.9 Building, Huafu Industrial Park, Huachang Road, Longhua District, Shenzhen, Guangdong, China Test specification ........................... : Standard ........................................... : FCC Part 22: PUBLIC MOBILE SERVICES FCC Part 24: PERSONAL COMMUNICATIONS SERVICES Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .....................: Alarm Host Trade Mark ....................................... : N/A Manufacturer .................................... : SZ PGST Co., Ltd Model/Type reference....................... : PG-108 Listed Models ................................... : PG-103, PG-105 Frequency .......................................... GSM 850MHz; PCS 1900MHz; Modulation ....................................... : GMSK GPRS................................................. Supported Ratings ............................................. : DC 3.7V From battery and DC 5.0V From external circuit Result................................................ : PASS Report No.: CTA24010301204 Page 2 of 33 T E S T R E P O R T Equipment under Test : Alarm Host Model /Type : PG-108 Listed Models : PG-103, PG-105 Applicant : SZ PGST Co., Ltd Address : No.9 Building, Huafu Industrial Park, Huachang Road, Longhua District, Shenzhen, Guangdong, China Manufacturer : SZ PGST Co., Ltd Address : No.9 Building, Huafu Industrial Park, Huachang Road, Longhua District, Shenzhen, Guangdong, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA24010301204 Page 3 of 33 Contents 1 T E S T S T A N D A R D S ................................................................. 4 2 S U M M A R Y ............................................................................ 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Equipment under Test 5 2.4 Short description of the Equipment under Test (EUT) 6 2.5 EUT configuration 6 2.6 Related Submittal(s) / Grant (s) 6 2.7 Modifications 6 2.8 General Test Conditions/Configurations 6 2.9 Modifications 6 3 T E S T E N V I R O N M E N T .............................................................. 7 3.1 Address of the test laboratory 7 3.2 Test Facility 7 3.3 Environmental conditions 7 3.4 Test Description 7 3.5 Equipments Used during the Test 9 4 T E S T C O N D I T I O N S A N D R E S U L T S ........................................... 10 4.1 Output Power 10 4.2 Radiated Spurious Emssion 13 4.3 Occupied Bandwidth and Emission Bandwidth 16 4.4 Band Edge Complicance 18 4.5 Spurious Emssion on Antenna Port 20 4.6 Frequency Stability Test 29 4.7 Peak-to-Average Ratio (PAR) 31 5 T E S T S E T U P P H O T O S O F T H E E U T ......................................... 33 6 E X T E RN A L A N D I N T E R N A L P H OT O S O F T H E E U T ...................... 33 Report No.: CTA24010301204 Page 4 of 33 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Part 2: FREQUENCY ALLOCA-TIONS AND RADIO TREATY MAT-TERS; GENERAL RULES AND REG-ULATIONS FCC Part 22 Subpart H: PRIVATE LAND MOBILE RADIO SERVICES. FCC Part 24 Subpart E: PUBLIC MOBILE SERVICES ANSI/TIA-603-E-2016: Land Mobile FM or PM Communications Equipment Measurement and Performance Standards. ANSI C63.26-2015: IEEE/ANSI Standard for Compliance Testing of Transmitters Used in Licensed Radio Services FCCKDB971168D01 Power Meas License Digital Systems Report No.: CTA24010301204 Page 5 of 33 2 S U M M A R Y 2.1 General Remarks Date of receipt of test sample : Jan. 03, 2024 Testing commenced on : Jan. 03, 2024 Testing concluded on : Jan. 11, 2024 2.2 Product Description Product Name: Alarm Host Model/Type reference: PG-108 Power supply: DC 3.7V From battery and DC 5.0V From external circuit Adapter information (Auxiliary test supplied by test Lab): Model: EP-TA20CBC Input: AC 100-240V 50/60Hz Output: DC 5V 2A Hardware version: V2.9 Software version: V1 testing sample ID: CTA240103012-1# (Engineer sample), CTA240103012-2#(Normal sample) Modilation Type GMSK Antenna Type Spring Antenna GSM/EDGE/GPRS Supported GPRS GSM/GPRS Power Class GSM850:Power Class 4/ PCS1900:Power Class 1 GSM/GPRS Operation Frequency GSM850 :824.2MHz-848.8MHz/PCS1900:1850.2MHz-1909.8MHz GPRS Operation Frequency Band GPRS850/GPRS1900 GPRS Multislot Class Multi-slot Class 12 Extreme temp. Tolerance -30°C to +50°C GPRS operation mode Class B Antenna gain: GSM850:1.0dbi,DCS1900: 1.0dbi 2.3 Equipment under Test Power supply system utili…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2AIT9-PG-108 Test Setup Photos of the EUT FCC ID: 2AIT9-PG-108

Contact Information

Applicant

DU ZHIXIAN
[email protected]0775-33252178Fax: 0775-33252179

Test Firm

SHENZHEN CTA TESTING TECHNOLOGY CO., LTD.Eric Wang
[email protected]+86 755 2322 5875

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz685.50 mW247KGXW2.5 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is ERP below 1GHz and EIRP above 1GHz. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

Other Applications from SZ PGST CO., LTD

Wi-Fi Smart Caller - FCC ID 2AIT9-PG-M06 - PGST CO., LTD
2AIT9-PG-M06

Wi-Fi Smart Caller

Jul 08, 2026

Equipment Class

DTS - Digital Transmission System
Door contact sensor - FCC ID 2AIT9-PG-B02 - PGST CO., LTD
2AIT9-PG-B02

Door contact sensor

Jul 08, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wireless Interlinked Smoke Alarm - FCC ID 2AIT9-PG-S12 - PGST CO., LTD
2AIT9-PG-S12

Wireless Interlinked Smoke Alarm

Jul 08, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control - FCC ID 2AIT9-PG-F02 - PGST CO., LTD
2AIT9-PG-F02

Remote Control

Jul 08, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wi-Fi Emergency Button - FCC ID 2AIT9-PG-J05 - PGST CO., LTD
2AIT9-PG-J05

Wi-Fi Emergency Button

Jul 08, 2026

Equipment Class

DTS - Digital Transmission System