FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. PGST CO., LTD/
  3. 2AIT9-PG-S12

2AIT9-PG-S12Wireless Interlinked Smoke Alarm

PGST CO., LTD
Wireless Interlinked Smoke Alarm - FCC ID 2AIT9-PG-S12 - PGST CO., LTD
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jul 08, 2026
Application Purpose
Original Equipment
Equipment Note
Wireless Interlinked Smoke Alarm
Frequency Range
433.92000000 - 433.92000000
Company
PGST CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

(1) Self-check Test: Press the [TEST/ ] button on any alarm or the remote control. All interconnected alarms will trigger audible and visual alarms in sequence, indicating normal functionality. (2)Smoke Alarm Test: Bring test smoke close to any alarm. All interconnected devices will trigger audible and visual alarms in sequence, indicating normal functionality. (3)High-Temperature Test: Place any alarm in an environment exceeding 57°C. Once it triggers, all interconnected devices will activate audible and visual alerts sequentially, confirming normal operation. Tension de fonctionnement: DC 3V (Batterie lithium CR123A remplaçable) Courant en veille: < 35ÎŒA Courant d’alarme: < 100mA Alarme de tempĂ©rature: >57°C DurĂ©e de vie de la batterie: 3 ans Niveau sonore d’alarme: >85dB FrĂ©quence sans fil: 433,92 MHz Distance de transmission: ≄200 m (en zone ouverte) Nombre maximum de dispositifs interconnectĂ©s:200 unitĂ©s Mode d’installation: Montage au plafond TempĂ©rature de fonctionnement: –10°C ~ 55°C HumiditĂ© de fonctionnement: ≀95%RH Normes europĂ©ennes: EN 14604:2005 Normes amĂ©ricaines: UL 217 (ConformĂ©ment aux spĂ©cifications, voir l'Ă©tiquette arriĂšre.) Betriebsspannung: DC 3V (Austauschbare CR123A Lithiumbatterie) Standby-Strom: < 35ÎŒA Alarmstrom: < 100mA Temperaturalarm: >57°C Batterielebensdauer: 3 Jahre Alarmschallempfindlichkeit: >85dB Funkfrequenz: 433,92 MHz Übertragungsdistanz: ≄200 m (Freifeld) Max. Anzahl vernetzter GerĂ€te: 200 StĂŒck Installationsart: Deckenmontage Betriebstemperatur: –10°C ~ 55°C Betriebsfeuchtigkeit: ≀95%RH EuropĂ€ische Normen: EN 14604:2005 US-Normen: UL 217 (GemĂ€ĂŸ Versandangaben, siehe RĂŒcketikett.) Deutsch Français Italiano Español Kurzanleitung fĂŒr den drahtlosen vernetzten Rauchmelder 01 Außenansicht 05 Technische Spezifikationen Guide de dĂ©marrage rapide de l’alarme de fumĂ©e sans fil interconnectĂ©e 01 SchĂ©ma d'apparence 05 SpĂ©cifications techniques Guida rapida all’allarme antincendio wireless interconnesso 01 Schema dell’aspetto GuĂ­a de inicio rĂĄpido del detector de humo inalĂĄmbrico interconectado 01 Diagrama de apariencia TensiĂłn de funcionamiento: DC 3V (BaterĂ­a de litio CR123A reemplazable) Corriente en reposo: < 35ÎŒA Corriente en alarma: < 100mA Alarma de temperatura: >57°C DuraciĂłn de la baterĂ­a: 3 años Nivel de sonido de alarma: >85dB Frecuencia inalĂĄmbrica: 433,92 MHz Distancia de transmisiĂłn: ≄200 m (en zona abierta) NĂșmero mĂĄximo de dispositivos interconectados:200 unidades MĂ©todo de instalaciĂłn: Montaje en techo Temperatura de funcionamiento: –10°C ~ 55°C Humedad de funcionamiento: ≀95%RH Normas UE: EN 14604:2005 Normas EE. UU.: UL 217 (SegĂșn especificaciones de envĂ­o, ver etiqueta trasera.) 05 Especificaciones tĂ©cnicas Wireless Interconnected Smoke Alarm Quick Start Manual 01 Appearance Diagram 02 Factory Configuration and Installation Notes The alarms are pre-configured for interconnection and successfully paired with the included remote control. Before installation, test all wireless alarms to confirm the interconnection is functioning properly before putting them into service.To add more alarms to the existing network, please refer to the detailed user manual. 03 Test Functions 04 Installation 02 Werkseinstellungen und Installationshinweise Die Alarme sind vorinstalliert fĂŒr die Vernetzung und werden mit der beigefĂŒgten Fernbedienung erfolgreich gepaart. Bevor Sie sie installieren, testen Sie alle drahtlosen Alarme, um sicherzustellen, dass die Vernetzung korrekt funktioniert, bevor Sie sie in Betrieb nehmen. Um weitere Alarme zu einem bestehenden Netzwerk hinzuzufĂŒgen, lesen Sie bitte das detaillierte Benutzerhandbuch. 03 Testfunktionen 04 Installation (1) Auto-test: Appuyez sur le bouton [TEST/ ] de n'importe quelle alarme ou de la tĂ©lĂ©commande. Toutes les alarmes interconnectĂ©es dĂ©clenchent des alarmes sonores et visuelles successivement. (2) Test d'alarme de fumĂ©e: Approchez de la fumĂ©e de test de n'importe quelle alarme. Tous les appareils interconnectĂ©s dĂ©clenchent des alarmes sonores et visuelles successivement. (3) Test de tempĂ©rature Ă©levĂ©e: Placez une alarme dans un environnement supĂ©rieur Ă  57°C. Une fois dĂ©clenchĂ©e, tous les appareils interconnectĂ©s activent des alertes sonores et visuelles successivement. (1) Selbsttest: DrĂŒcken Sie die [TEST/ ]-Taste an jedem Alarm oder der Fernbedienung. Alle vernetzten Alarme lösen nacheinander akustische und visuelle Alarme aus. (2) Rauchalarm-Test: Bringen Sie Testrauch in die NĂ€he eines beliebigen Alarms. Alle vernetzten GerĂ€te lösen nacheinander akustische und visuelle Alarme aus. (3) Hochtemperatur-Test: Platzieren Sie einen Alarm in einer Umgebung ĂŒber 57°C. Sobald er ausgelöst wird, aktivieren alle vernetzten GerĂ€te nacheinander akustische und visuelle Warnungen. 02 Configuration usine et notes d’installation Les alarmes sont prĂ©configurĂ©es pour la connexion et appairĂ©es avec succĂšs avec le tĂ©lĂ©commande fournie. Avant l'installation, testez tous les alarmes sans fil pour confirmer que la connexion fonctionne correctement avant de les mettre en service. Pour ajouter plus d'alarmes au rĂ©seau existant, veuillez consulter le manuel d'utilisation dĂ©taillĂ©. 03 Tests de fonctionnement Marquer et percer les trous Ă  l'aide du support, puis faire tourner l'alarme dans le sens des aiguilles d'une montre, dans la direction "OPEN→CLOSE", pour la fixer. Enfin, appuyer sur le bouton«TEST/ »pour confirmer le bon fonctionnement. 04 Installation (1) Autotest: Premere il pulsante [TEST/ ] su qualsiasi allarme o sul telecomando. Tutti gli allarmi interconnessi attivano in sequenza allarmi acustici e visivi. (2) Test allarme fumo: Avvicinare il fumo di prova a qualsiasi allarme. Tutti i dispositivi interconnessi attivano in sequenza allarmi acustici e visivi. (3) Test alta temperatura: Posizionare un allarme in un ambiente superiore a 57°C. Una volta attivato, tutti i dispositivi interconnessi attivano in sequenza avvisi acustici e visivi. 02 Configurazione di fabbrica e note di installazione Gli allarmi sono pr


Text truncated - open the document above for the full version.

Attestation Statements

PGSTCO.,LTD Address1stFloor,9thBlock,HuafuIndustrialPark,LangkouCommunity,Dalang,Longhua District,ShenzhenCity FRN:0025677766 Date:2026-06-28 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2AIT9-PG-S12 (“PGSTCO.,LTD”)certifiesthat,asofthedateofthefilingoftheapplication,( PlethyInc )is ourdesignatedU.S.agentforserviceofprocessforthe abovereferencedFCCID.(“PGSTCO.,LTD”)acceptstomaintainanagentfornoless thanoneyearafterthegranteehasterminatedallmarketingandimportationorthe conclusionofanyCommission-relatedproceedinginvolvingtheequipment. ( PlethyInc )accepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: Name:PlethyInc FRN:0035219609 Address:2362QumeDr,Suite#DSanJose,CA95131UnitedStates ContactPerson:RajaSundaram/CEO Tel.:(408)607-7646 Email:[email protected] Sincerely, PGSTCo.,LTDPlethyInc Name:DuZhixianName:RajaSundaram Title:ManagerTitle:CEO Date:2026-06-28 Date:2026-06-30

Attestation Statements

Rev1/26/2023 PGSTCO.,LTD FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:June30,2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2AIT9-PG-S12 [PGSTCO.,LTD]certifiesthattheequipmentforwhichauthorizationissoughtisnot“covered” equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903oftheFCC rules. [PGSTCO.,LTD]certifiesthattheequipmentforwhichauthorizationissoughtdoesnotinclude cybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.oranyofitssuccessors andassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofitssuccessorsand assignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446D01Covered EquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, ContactName:DuZhixian Rev1/26/2023 PGSTCO.,LTD FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:June30,2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2AIT9-PG-S12 [PGSTCO.,LTD]certifiesthat,asofthedateofthefilingoftheapplication,theapplicantisnotidentified ontheCoveredList(asaspecificallynamedentityoranyofitssubsidiariesoraffiliates)asanentity producing“covered”equipment. Sincerely, ContactName:DuZhixian

Cover Letter(s)

EffectiveDate:April2,2020QSF7.6.4-8–AgentAuthorizationLetterTemplatePage1of1 RevisionDate:Revision:0 PGSTCo.,LTD Date:Date:June30,2026 ProductModelNumber:PG-S12 FCCID:2AIT9-PG-S12 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C.CanadaV5J5K5to actonourbehalfonallmattersconcerningtheabovenamedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformationrelatedtothe approvalprojecttotheappliedcertificationbodyandtothenotificationentitiesandtodiscuss anyissuesconcerningtheapprovalapplication.AnyandallactscarriedoutbyQAILaboratories Ltd.onourbehalfshallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:Manager Email:[email protected] Telephone:0775-33252178 Onbehalfof:PGSTCo.,LTD

Cover Letter(s)

PGSTCO.,LTD OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:June30,2026 Subject;RequestforConfidentiality FCCID:2AIT9-PG-S12 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram OperationalDescription Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:DuZhixian Title:Manager

Cover Letter(s)

PGSTCO.,LTD To:QAILABORATORIESLTD. DECLARATIONOFIDENTITY Herebywe: PGSTCO.,LTD (NameofManufacturer) BasicModelNumber:PG-S12 BasicBrandName:/ BasicProductName:WirelessInterlinkedSmokeAlarm BasicTestReportApplication Number:QCT26ER-0091-01 DeclaretheCircuit,PCBLayout;ElectricalPartsandOutlookofthefollowing product(s)areidenticaltothebasicmodel: □  New/☑AdditionalModelNumber(s):PG-S13,PG-S14,PG-S15, PG-S16 □New/□AdditionalBrandName(s): □New/□AdditionalProductName(s): Exceptthefollowing(s):PCBboard,structureandinternalofthese model(s)arethesame,Justdifferenceistheshellandmodel. Remarks: SignaturewithCompanyChop: PrintedName:DuZhixian DATE:2026.07.04

External Photos

ShenzhenQCTestingLaboratoryCo.,Ltd. Page 1 of 5 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ProductName: WirelessInterlinkedSmokeAlarm TestModelNo.: PG-S12 EUTConstructionalDetails ShenzhenQCTestingLaboratoryCo.,Ltd. Page 2 of 5 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ShenzhenQCTestingLaboratoryCo.,Ltd. Page 3 of 5 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ShenzhenQCTestingLaboratoryCo.,Ltd. Page 4 of 5 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ShenzhenQCTestingLaboratoryCo.,Ltd. Page 5 of 5 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ------End------

ID Label/Location Info

FCCID:2AIT9-PG-S12 Length:500mm Width:300mm

Internal Photos

ShenzhenQCTestingLaboratoryCo.,Ltd. Page 1 of 4 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ProductName: WirelessInterlinkedSmokeAlarm TestModelNo.: PG-S12 EUTConstructionalDetails ShenzhenQCTestingLaboratoryCo.,Ltd. Page 2 of 4 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ShenzhenQCTestingLaboratoryCo.,Ltd. Page 3 of 4 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn 433MRXAntenna 433MTXAntenna ShenzhenQCTestingLaboratoryCo.,Ltd. Page 4 of 4 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ------End------

RF Exposure Info

ShenzhenQCTestingLaboratoryCo.,Ltd. Page1of1 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn FCCID:2AIT9-PG-S12 RFExposureEvaluation AccordingtoKDB447498D04RFExposureProceduresandEquipmentAuthorizationPoliciesforMobileand PortableDevicespart2.1.2,asingleRFsourceisexemptRFdevice(fromtherequirementtoshowdata demonstratingcompliancetoRFexposurelimits,aspreviouslymentioned)iftheavailablemaximum time-averagedpowerisnomorethan1mW,regardlessofseparationdistanceT'hisexemptionappliestoall operatingconligurationsandexposureconditions,forthefrequencyrange100kHzto100GHz,regardlessof fixed,mobile,orportabledeviceexposureconditions.Thisisastandaloneexemption,anditcannotbe appliedinconjunctionwithanyothertestexemption. Theresultisroundedtoonedecimalplaceforcomparison Here. ThedevicehasbeenevaluatedtomeetgeneralRFexposurerequirement.Thedevicecanbeused inportableexposureconditionwithoutrestriction. TestResultofRFExposureEvaluation For433.92M Frequency(MHz) Power (dBuV/m) Power (dBm) Power (mW) Limmit (mW) 433.92M90.67-4.530.35241 Notes:90.67dBuV/m-95.2=-4.53dBm Conclusion: 0.3524mW<1mW,soaSARtestisnotrequired.

Test Report

Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT26ER-0091 -01 Page 1 of 22 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn FCC PART 15.231 TEST REPORT On Behalf of PGST CO., LTD 1st Floor, 9th Block, Huafu Industrial Park, Langkou Community, Dalang,Longhua District, Shenzhen City FCC ID: 2AIT9-PG-S12 Model: PG-S12, PG-S13, PG-S14, PG-S15, PG-S16 July 06, 2026 T hi s Repor t Concer ns: Or iginal Report Equi pm ent T ype: W ir eles s I nt er link ed Sm ok e Alar m Test Engineer: Fan Yang Report Number: QCT26ER-0091 -01 Test Date: May 20 2026~June 03, 2026 Test Result: Pass Reviewed By: Vincent Yang Approved By: Kendy Wang Prepared By: Shenzhen QC Testing Laboratory Co., Ltd. East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT26ER-0091 -01 Page 2 of 22 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Table of Contents 1. GENERAL INFORMATION ............................................................................................ 4 1.1 Product Description for Equipment under Test (EUT) ......................................................... 4 1.2 System Test Configuration .................................................................................................. 4 1.3 Test Facility.......................................................................................................................... 5 1.4 Measurement Uncertainty .................................................................................................... 5 2. SUMMARY OF TEST RESULTS ................................................................................... 6 3. LIST OF TEST AND MEASUREMENT INSTRUMENTS ............................................... 7 3.1 Radiated Emission Test ....................................................................................................... 7 3.2 RF Conducted test ............................................................................................................... 7 4. ANTENNA REQUIREMENT ........................................................................................... 8 5. RADIATED EMISSION METHOD .................................................................................. 9 5.1 Applicable Standard............................................................................................................. 9 5.2 Limit ..................................................................................................................................... 9 5.3 Receiver setup ................................................................................................................... 10 5.4 Test setup .......................................................................................................................... 10 5.5 Test Procedure .................................................................................................................. 11 5.6 Test Data ........................................................................................................................... 11 6. 20DB OCCUPY BANDWIDTH ..................................................................................... 12 6.1 Applicable Standard........................................................................................................... 16 6.2 Limit ................................................................................................................................... 16 6.3 Test setup .......................................................................................................................... 16 6.4 Test Data ........................................................................................................................... 16 7. RELEASE TIME MEASUREMENT .............................................................................. 17 7.1 Applicable Standard........................................................................................................... 18 7.2 Limit ................................................................................................................................... 18 7.3 Test Procedure .................................................................................................................. 18 7.4 Test setup .......................................................................................................................... 18 7.5 Test Data ........................................................................................................................... 18 8. DUTY CYCLE ............................................................................................................... 20 8.1 Applicable Standard........................................................................................................... 20 8.2 Limit ................................................................................................................................... 20 8.3 Test setup .......................................................................................................................... 20 8.4 Test Procedure .................................................................................................................. 20 8.5 Test Data ........................................................................................................................... 20 Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT26ER-0091 -01 Page 3 of 22 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, F


Text truncated - open the document above for the full version.

Test Report

SHENZHENDASHANCOMMUNICATIONCO.,LTD SampleConfirmationLetter Applicant PGSTCo.,Ltd ProjectName PG-13 PartName 433MTransmission antennaspring frequencyrange 433±5MHz PartNumberDS-T433E15-07-Aedition R:A Sampletype IssueDate 2024.05.09 Preparedby Reviewedby Approve Customer Approval purchasedinlargequantitieswitnessing:______________ □LimitededitionrecognitionlimitïŒżïŒżïŒżïŒŒreason_______ Address 1stFloor,9thBlock,HuafuIndustrialPark,Langkou Community,Dalang,Longhua District,ShenzhenCity Manufacturer ShenzhenQiliSpringElectronicsCo.,Ltd. Address 304,Building46,ZoneB,YuanshanIndustrialPark,Shangcun Community,GongmingSub-district,GuangmingDistrict, ShenzhenCity,GuangdongProvince,China number DS-QR-EN-001 versionA0Shelflife2yearseffectivedate2023.05.09 1 □Fullyrecognized,canbe 2 SHENZHENDASHANCOMMUNICATIONCO.,LTD Content 1、Cover)..................................................................................1 2、Content.................................................................................2 3、ProductPicture......................................................................3 4、Specification........................................................................4 5、Electricitytestreport..........................................................4-5 3 SHENZHENDASHANCOMMUNICATIONCO.,LTD 3、Productdimensiondiagram SHENZHENDASHANCOMMUNICATIONCO.,LTD 4 4.Specification FrequencyRange(MHz) 433±5 Antennagain(dBi) 0 Efficiency% 25 VSWR ≀3.0Forreferenceonly InputImpedance(Ω) 50 OperationTemperature -40°C~65°C StorageTemperature -40°C~65°C 5、RadiationReport 5.1standingwave 5.2Efficiencychart ANT frequencypointefficiency gain 42325%-1.9 42725%-1.3 43128%-1.5 43528%-1.2 43928%0 44328%-1.0 SHENZHENDASHANCOMMUNICATIONCO.,LTD 5.3Directionaldiagram 6.TestSetupPhoto 5

Test Setup Photos

ShenzhenQCTestingLaboratoryCo.,Ltd. Page 1 of 1 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ProductName: WirelessInterlinkedSmokeAlarm TestModelNo.: PG-S12 PhotographofTestSetup RadiatedEmissions(30MHz-1GHz) RadiatedEmissions(Above1GHz)

Contact Information

Applicant

DU ZHIXIAN
[email protected]Fax: 0775-33252179

Technical Contact

Plethy IncRaja Sundaram
[email protected]

2362 Qume Dr, Suite #D San Jose, CA 95131 · United States

Test Firm

Shenzhen QC Testing Laboratory CO., Ltd.Kendy Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from PGST CO., LTD

Wi-Fi Smart Caller - FCC ID 2AIT9-PG-M06 - PGST CO., LTD
2AIT9-PG-M06

Wi-Fi Smart Caller

Jul 08, 2026

Equipment Class

DTS - Digital Transmission System
Door contact sensor - FCC ID 2AIT9-PG-B02 - PGST CO., LTD
2AIT9-PG-B02

Door contact sensor

Jul 08, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control - FCC ID 2AIT9-PG-F02 - PGST CO., LTD
2AIT9-PG-F02

Remote Control

Jul 08, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wi-Fi Emergency Button - FCC ID 2AIT9-PG-J05 - PGST CO., LTD
2AIT9-PG-J05

Wi-Fi Emergency Button

Jul 08, 2026

Equipment Class

DTS - Digital Transmission System
Pet-Immune PIR Detector - FCC ID 2AIT9-PG-P03 - PGST CO., LTD
2AIT9-PG-P03

Pet-Immune PIR Detector

Jul 08, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter