Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Pet-Immune PIR Detector User Manual Before using this device, carefully read and understand all contents of this manual.Incorrect installation or use may lead to device malfunction, false alarms, or failure to provide effective protection.Retain this manual for future reference.Images are for reference only; actual product features and appearance may vary. I. Product OverviewII. Technical Specifications III. Using the Infrared Detector V. Installation & Calibration IV. Pairing with Alarm Control Panel 1.1 Product Components Description Indicator Light Test Button Detection Window Detection Window Power Switch Mounting Bracket Battery Compartment Powering On the Device • Slide the detector's Power Switch to ON. • Normal Response: Red LED blinks twice, confirming operational status. • No Response? Open the Battery Compartment and replace with new batteries. Testing the Alarm • Briefly press the Test Button once. • Normal Response: Red LED blinks once, indicating proper function. • No Response? Open the Battery Compartment and replace with new batteries. Follow the Alarm Control Panel User Manual to activate its Learning Mode for detectors. Place the detector near the control panel. Press the Test Button or trigger motion directly in front of the detector to transmit the pairing signal. The detector and control panel will pair successfully. NOTE: • If the alarm control panel fails to pair with the detector within 20 seconds, it will automatically exit pairing mode. • Should pairing fail, repeat steps to to retry the process. 1.2 Visual Indicators • Indicator Light: Displays the operating status of the detector. • Detection Window: Receives human infrared radiation for PIR detection. • Mounting Bracket: Used for installing the detector. • Test Button: For device testing and pairing operations. • Power Switch: Turns the detector ON/OFF. • Battery Compartment: Holds 2×AAA batteries. Status Power On Test Alarm Triggered Infrared Alarm Triggered Low Battery LED Indication Red LED blinks 2 times Red LED blinks 1 time Red LED blinks 1 time Red LED blinks 3 times Operating Voltage Standby Current Alarm Current Detection Range Detection Angle Transmission Freq. Wireless Range Operating Environment Mounting Height Pet Immunity DC 3V (2×1.5V AAA batteries) < 20 μA < 25 mA 8~12 m 110° 433.92MHz (ASK) > 100 m (open area) -20°C~55°C, <95%RH 1.8 m ~ 2.2 m ≤25kg (55lbs) Mounting Height 2m Detection Range:8~12m PIR Coverage Diagram This product employs two infrared detection sensors, effectively resolving the issue of false alarms caused by small pets. Simultaneously, it utilizes the operating principle of dual infrared signal symmetry to significantly enhance product stability. To ensure optimal performance, we strongly recommend users thoroughly review the product instruction manual. Pet-Immune PIR Detector User Manual Before using this device, carefully read and understand all contents of this manual.Incorrect installation or use may lead to device malfunction, false alarms, or failure to provide effective protection.Retain this manual for future reference.Images are for reference only; actual product features and appearance may vary. I. Product OverviewII. Technical Specifications III. Using the Infrared Detector V. Installation & Calibration IV. Pairing with Alarm Control Panel 1.1 Product Components Description Indicator Light Test Button Detection Window Detection Window Power Switch Mounting Bracket Battery Compartment Powering On the Device • Slide the detector's Power Switch to ON. • Normal Response: Red LED blinks twice, confirming operational status. • No Response? Open the Battery Compartment and replace with new batteries. Testing the Alarm • Briefly press the Test Button once. • Normal Response: Red LED blinks once, indicating proper function. • No Response? Open the Battery Compartment and replace with new batteries. Follow the Alarm Control Panel User Manual to activate its Learning Mode for detectors. Place the detector near the control panel. Press the Test Button or trigger motion directly in front of the detector to transmit the pairing signal. The detector and control panel will pair successfully. NOTE: • If the alarm control panel fails to pair with the detector within 20 seconds, it will automatically exit pairing mode. • Should pairing fail, repeat steps to to retry the process. 1.2 Visual Indicators • Indicator Light: Displays the operating status of the detector. • Detection Window: Receives human infrared radiation for PIR detection. • Mounting Bracket: Used for installing the detector. • Test Button: For device testing and pairing operations. • Power Switch: Turns the detector ON/OFF. • Battery Compartment: Holds 2×AAA batteries. Status Power On Test Alarm Triggered Infrared Alarm Triggered Low Battery LED Indication Red LED blinks 2 times Red LED blinks 1 time Red LED blinks 1 time Red LED blinks 3 times Operating Voltage Standby Current Alarm Current Detection Range Detection Angle Transmission Freq. Wireless Range Operating Environment Mounting Height Pet Immunity DC 3V (2×1.5V AAA batteries) < 20 μA < 25 mA 8~12 m 110° 433.92MHz (ASK) > 100 m (open area) -20°C~55°C, <95%RH 1.8 m ~ 2.2 m ≤25kg (55lbs) Mounting Height 2m Detection Range:8~12m PIR Coverage Diagram This product employs two infrared detection sensors, effectively resolving the issue of false alarms caused by small pets. Simultaneously, it utilizes the operating principle of dual infrared signal symmetry to significantly enhance product stability. To ensure optimal performance, we strongly recommend users thoroughly review the product instruction manual. VI.Battery Replacement 1. Installation Requirements 1.1 Optimal Motion Detection Infrared detection sensitivity is highest when detecting lateral movement relative to the sensor lens, while axial movement (approaching/receding) yields reduced sensitivity. Select installation locations accordingly. 1.2 Mounting Height Installation height critically impacts both cov…
Text truncated - open the document above for the full version.
PGSTCO.,LTD Address:1stFloor,9thBlock,HuafuIndustrialPark,LangkouCommunity,Dalang,Longhua District,ShenzhenCity FRN:0025677766 Date:2026-06-28 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2AIT9-PG-P03 (“PGSTCO.,LTD”)certifiesthat,asofthedateofthefilingoftheapplication,( PlethyInc )is ourdesignatedU.S.agentforserviceofprocessforthe abovereferencedFCCID.(“PGSTCO.,LTD”)acceptstomaintainanagentfornoless thanoneyearafterthegranteehasterminatedallmarketingandimportationorthe conclusionofanyCommission-relatedproceedinginvolvingtheequipment. ( PlethyInc )accepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: Name:PlethyInc FRN:0035219609 Address:2362QumeDr,Suite#DSanJose,CA95131UnitedStates ContactPerson:RajaSundaram/CEO Tel.:(408)607-7646 Email:[email protected] Sincerely, PGSTCo.,LTDPlethyInc Name:DuZhixianName:RajaSundaram Title:ManagerTitle:CEO Date:2026-06-28 Date:2026-06-30
Rev1/26/2023 PGSTCO.,LTD FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:June30,2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2AIT9-PG-P03 [PGSTCO.,LTD]certifiesthattheequipmentforwhichauthorizationissoughtisnot“covered” equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903oftheFCC rules. [PGSTCO.,LTD]certifiesthattheequipmentforwhichauthorizationissoughtdoesnotinclude cybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.oranyofitssuccessors andassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofitssuccessorsand assignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446D01Covered EquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, ContactName:DuZhixian Rev1/26/2023 PGSTCO.,LTD Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: June 30, 2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2AIT9-PG-P03 [PGST CO., LTD] certifies that, as of the date of the filing of the application, the applicantis notidentified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, ContactName:DuZhixian
EffectiveDate:April2,2020QSF7.6.4-8–AgentAuthorizationLetterTemplatePage1of1 RevisionDate:Revision:0 PGSTCo.,LTD Date:Date:June30,2026 ProductModelNumber:PG-P03 FCCID:2AIT9-PG-P03 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C.CanadaV5J5K5to actonourbehalfonallmattersconcerningtheabovenamedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformationrelatedtothe approvalprojecttotheappliedcertificationbodyandtothenotificationentitiesandtodiscuss anyissuesconcerningtheapprovalapplication.AnyandallactscarriedoutbyQAILaboratories Ltd.onourbehalfshallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:Manager Email:[email protected] Telephone:0775-33252178 Onbehalfof:PGSTCo.,LTD
PGSTCO.,LTD OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:June30,2026 Subject;RequestforConfidentiality FCCID:2AIT9-PG-P03 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram OperationalDescription Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:DuZhixian Title:Manager
ShenzhenQCTestingLaboratoryCo.,Ltd. Page 1 of 4 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ProductName: Pet-ImmunePIRDetector TestModelNo.: PG-P03 EUTConstructionalDetails ShenzhenQCTestingLaboratoryCo.,Ltd. Page 2 of 4 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ShenzhenQCTestingLaboratoryCo.,Ltd. Page 3 of 4 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ShenzhenQCTestingLaboratoryCo.,Ltd. Page 4 of 4 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ------End------
FCCID:2AIT9-PG-P03 Length:320mm Width:260mm
ShenzhenQCTestingLaboratoryCo.,Ltd. Page 1 of 3 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ProductName: Pet-ImmunePIRDetector TestModelNo.: PG-P03 EUTConstructionalDetails: ShenzhenQCTestingLaboratoryCo.,Ltd. Page 2 of 3 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn 433MTXAntenna ShenzhenQCTestingLaboratoryCo.,Ltd. Page 3 of 3 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ------End------
ShenzhenQCTestingLaboratoryCo.,Ltd. Page1of1 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn FCCID:2AIT9-PG-P03 RFExposureEvaluation AccordingtoKDB447498D04RFExposureProceduresandEquipmentAuthorizationPoliciesforMobileand PortableDevicespart2.1.2,asingleRFsourceisexemptRFdevice(fromtherequirementtoshowdata demonstratingcompliancetoRFexposurelimits,aspreviouslymentioned)iftheavailablemaximum time-averagedpowerisnomorethan1mW,regardlessofseparationdistanceT'hisexemptionappliestoall operatingconligurationsandexposureconditions,forthefrequencyrange100kHzto100GHz,regardlessof fixed,mobile,orportabledeviceexposureconditions.Thisisastandaloneexemption,anditcannotbe appliedinconjunctionwithanyothertestexemption. Theresultisroundedtoonedecimalplaceforcomparison Here. ThedevicehasbeenevaluatedtomeetgeneralRFexposurerequirement.Thedevicecanbeused inportableexposureconditionwithoutrestriction. TestResultofRFExposureEvaluation For433.92M Frequency(MHz) Power (dBuV/m) Power (dBm) Power (mW) Limmit (mW) 433.92M91.38-3.820.41501 Notes:91.38dBuV/m-95.2=-3.82dBm Conclusion: 0.4150mW<1mW,soaSARtestisnotrequired.
Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT26ER-0092 -01 Page 1 of 22 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn FCC PART 15.231 TEST REPORT On Behalf of PGST CO., LTD 1st Floor, 9th Block, Huafu Industrial Park, Langkou Community, Dalang,Longhua District, Shenzhen City FCC ID: 2AIT9-PG-P03 Model: PG-P03 July 04, 2026 T hi s Repor t Concer ns: Or iginal Report Equi pm ent T ype: Pet-Imm une PI R Det ect or Test Engineer: Fan Yang Report Number: QCT26ER-0092 -01 Test Date: May 20 2026~June 03, 2026 Test Result: Pass Reviewed By: Vincent Yang Approved By: Kendy Wang Prepared By: Shenzhen QC Testing Laboratory Co., Ltd. East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT26ER-0092 -01 Page 2 of 22 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China Tel: 0755-23008269 Fax: 0755-23726780 www.qctest.com.cn Table of Contents 1. GENERAL INFORMATION ............................................................................................ 4 1.1 Product Description for Equipment under Test (EUT) ......................................................... 4 1.2 System Test Configuration .................................................................................................. 4 1.3 Test Facility.......................................................................................................................... 5 1.4 Measurement Uncertainty .................................................................................................... 5 2. SUMMARY OF TEST RESULTS ................................................................................... 6 3. LIST OF TEST AND MEASUREMENT INSTRUMENTS ............................................... 7 3.1 Radiated Emission Test ....................................................................................................... 7 3.2 RF Conducted test ............................................................................................................... 7 4. ANTENNA REQUIREMENT ........................................................................................... 8 5. RADIATED EMISSION METHOD .................................................................................. 9 5.1 Applicable Standard............................................................................................................. 9 5.2 Limit ..................................................................................................................................... 9 5.3 Receiver setup ................................................................................................................... 10 5.4 Test setup .......................................................................................................................... 10 5.5 Test Procedure .................................................................................................................. 11 5.6 Test Data ........................................................................................................................... 11 6. 20DB OCCUPY BANDWIDTH ..................................................................................... 12 6.1 Applicable Standard........................................................................................................... 16 6.2 Limit ................................................................................................................................... 16 6.3 Test setup .......................................................................................................................... 16 6.4 Test Data ........................................................................................................................... 16 7. RELEASE TIME MEASUREMENT .............................................................................. 17 7.1 Applicable Standard........................................................................................................... 18 7.2 Limit ................................................................................................................................... 18 7.3 Test Procedure .................................................................................................................. 18 7.4 Test setup .......................................................................................................................... 18 7.5 Test Data ........................................................................................................................... 18 8. DUTY CYCLE ............................................................................................................... 20 8.1 Applicable Standard........................................................................................................... 20 8.2 Limit ................................................................................................................................... 20 8.3 Test setup .......................................................................................................................... 20 8.4 Test Procedure .................................................................................................................. 20 8.5 Test Data ........................................................................................................................... 20 Shenzhen QC Testing Laboratory Co., Ltd. Report No.: QCT26ER-0092 -01 Page 3 of 22 Address: East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, …
Text truncated - open the document above for the full version.
SHENZHENDASHANCOMMUNICATIONCO.,LTD SampleConfirmationLetter Applicant PGSTCo.,Ltd ProjectName PG-13 PartName 433MTransmission antennaspring frequencyrange 433±5MHz PartNumberDS-T433E15-07-Aedition R:A Sampletype IssueDate 2024.05.09 Preparedby Reviewedby Approve Customer Approval purchasedinlargequantitieswitnessing:______________ □Limitededitionrecognition,limit___,reason:_______ Address 1stFloor,9thBlock,HuafuIndustrialPark,Langkou Community,Dalang,Longhua District,ShenzhenCity Manufacturer ShenzhenQiliSpringElectronicsCo.,Ltd. Address 304,Building46,ZoneB,YuanshanIndustrialPark,Shangcun Community,GongmingSub-district,GuangmingDistrict, ShenzhenCity,GuangdongProvince,China number: DS-QR-EN-001 version:A0Shelflife:2yearseffectivedate:2023.05.09 1 □Fullyrecognized,canbe 2 SHENZHENDASHANCOMMUNICATIONCO.,LTD Content 1、Cover)..................................................................................1 2、Content.................................................................................2 3、ProductPicture......................................................................3 4、Specification........................................................................4 5、Electricitytestreport..........................................................4-5 3 SHENZHENDASHANCOMMUNICATIONCO.,LTD 3、Productdimensiondiagram SHENZHENDASHANCOMMUNICATIONCO.,LTD 4 4.Specification FrequencyRange(MHz) 433±5 Antennagain(dBi) 0 Efficiency(%) 25 VSWR ≤3.0Forreferenceonly InputImpedance(Ω) 50 OperationTemperature -40°C~65°C StorageTemperature -40°C~65°C 5、RadiationReport 5.1standingwave 5.2Efficiencychart ANT frequencypointefficiency gain 42325%-1.9 42725%-1.3 43128%-1.5 43528%-1.2 43928%0 44328%-1.0 SHENZHENDASHANCOMMUNICATIONCO.,LTD 5.3Directionaldiagram 6.TestSetupPhoto 5
ShenzhenQCTestingLaboratoryCo.,Ltd. Page 1 of 1 Address:Eastof1/F.,BuildingE,XinghongSciencePark,No.111,ShuikuRoad,Fenghuanggang,XixiangStreet,Bao'anDistrict,Shenzhen,Guangdong,China Tel:0755-23008269Fax:0755-23726780http://www.qctest.com.cn ProductName: Pet-ImmunePIRDetector TestModelNo.: PG-P03 PhotographofTestSetup RadiatedEmissions(30MHz-1GHz) RadiatedEmissions(Above1GHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

Wi-Fi Smart Caller
Equipment Class
DTS - Digital Transmission System
Door contact sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wireless Interlinked Smoke Alarm
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Control
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wi-Fi Emergency Button
Equipment Class
DTS - Digital Transmission System