
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC RF Exposure Information and Statement This device meets the government's requirements for exposure to radio waves. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons regardless of age or health. The SAR limit of USA (FCC) is 1.6 W/kg averaged. Device types: Intelligent Two Way Radio (FCC ID: 2AIV6-T640A) has also been tested against this SAR limit. SAR information on this and other pad can be viewed onΟline at http://www.fcc.gov/oet/ea/fccid/. Please use the device FCC ID number for search. This device was tested simulation typical 0mm to body and 25 mm front of face. To maintain FCC Warning This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Removing the battery, the FCC label is visible . compliance with FCC RF exposure requirements, use accessories should maintain a separation distance between the user's bodies mentioned above. For body-worn accessories, please use the provided belt clip, otherwise it may not comply with FCC RF exposure requirements.
Reference N Waltek Tes http://www EXHIBI EUT View 1 EUT View 2 No.: WTX19X sting Group w.semtest.co T 2 - EUT 1 2 X09063044W (Shenzhen) m.cn T EXTER W-3/4/5 Co., Ltd. RNAL PH HOTOGR APHS Reference N Waltek Tes http://www EUT View 3 EUT View 4 No.: WTX19X sting Group w.semtest.co 3 4 X09063044W (Shenzhen) m.cn W-3/4/5 Co., Ltd. Reference N Waltek Tes http://www EUT View 5 EUT View 6 No.: WTX19X sting Group w.semtest.co 5 6 X09063044W (Shenzhen) m.cn W-3/4/5 Co., Ltd. Reference N Waltek Tes http://www EUT View 7 No.: WTX19X sting Group w.semtest.co 7 X09063044W (Shenzhen) m.cn W-3/4/5 Co., Ltd.
Reference N Waltek Tes http://www EXHIBI Proposed Specificatio n it is visible durable to r expected lif e Proposed No.: WTX19X sting Group w.semtest.co T 1 - PRO FCC ID La ns: The label or easily acc emain fully l etime. Label Loca X09063044W (Shenzhen) m.cn ODUCT L abel Forma shall be secu cessible to th legible and in ation on EU W-3/4/5 Co., Ltd. LABELIN at urely affixed t he user, and ntact on the UT FCC NG to a permane shall not be device in al l ID Label Lo ently attached readily detac l normal cond cation d part of the d chable. The l ditions of use device, in a lo label shall be e throughout ocation where e sufficiently t the deviceβs e y s
Reference N Waltek Tes http://www EXHIBI EUT Housi n EUT Housi n No.: WTX19X sting Group w.semtest.co T 3 - EUT ng and Boar ng and Boar X09063044W (Shenzhen) m.cn T INTER rd View 1 rd View 2 W-3/4/5 Co., Ltd. NAL PHO OTOGRA APHS Reference N Waltek Tes http://www EUT Housi n EUT Housi n No.: WTX19X sting Group w.semtest.co ng and Boar ng and Boar X09063044W (Shenzhen) m.cn rd View 3 rd View 4 W-3/4/5 Co., Ltd. Reference N Waltek Tes http://www EUT Housi n Solder Boa r No.: WTX19X sting Group w.semtest.co ng and Boar rd-Compone X09063044W (Shenzhen) m.cn rd View 5 ent View 1 W-3/4/5 Co., Ltd. Reference N Waltek Tes http://www Solder Boa r Solder Boa r No.: WTX19X sting Group w.semtest.co rd-Compone rd-Compone X09063044W (Shenzhen) m.cn ent View 2 ent View 3 W-3/4/5 Co., Ltd. Reference N Waltek Tes http://www Solder Boa r Solder Boa r No.: WTX19X sting Group w.semtest.co rd-Compone rd-Compone X09063044W (Shenzhen) m.cn ent View 4 ent View 5 W-3/4/5 Co., Ltd. Reference N Waltek Tes http://www Solder Boa r Antenna V i W No.: WTX19X sting Group w.semtest.co rd-Compone iew Wi-Fi/BT/GP X09063044W (Shenzhen) m.cn ent View 6 PS Ant W-3/4/5 Co., Ltd. GSM /WC CDMA /LTE A LTE RX Ant. Ant.
Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Page 1 of 160 TEST REPORT Reference No. .................... : WTX19X09063044W FCC ID ................................ : 2AIV6-T640A Applicant ........................... : Shenzhen Inrico Electronics Co.,LTD Address ............................. : 3/F, Building NO.118, High Tech Industrial Park,72 Guowei Road, Luohu District,Shenzhen, China Product Name ................... : Intelligent Two Way Radio Test Model. ........................ : T640A Standards .......................... : FCC Part 2.1093 ANSI / IEEE C95.1 : 2005+A1:2010 ANSI / IEEE C95.3 : 2002(R2008) IEEE 1528 :2013 Date of Receipt sample .... : May.27, 2020 Date of Test........................ : May.27, 2020 to Jun.16, 2020 Date of Issue ..................... : Jun.17, 2020 Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Tested by: Reviewed By: Approved & Authorized By: Jack Sun / Project Engineer Lion Cai / RF Manager Silin Chen / Manager Reference No.: WTX19X09063044W Page 2 of 160 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn TABLE OF CONTENTS 1. General Information ................................................................................................................................................... 3 1.1 Product Description for Equipment Under Test (EUT) ......................................................................................... 3 1.2 Test Standards .................................................................................................................................................... 7 1.3 Test Methodology ................................................................................................................................................ 7 1.4 Test Facility ......................................................................................................................................................... 7 2. Summary of Test Results .......................................................................................................................................... 8 3. Specific Absorption Rate (SAR) ................................................................................................................................ 9 3.1 Introduction .......................................................................................................................................................... 9 3.2 SAR Definition ..................................................................................................................................................... 9 4. SAR Measurement System ...................................................................................................................................... 10 4.1 The Measurement System ................................................................................................................................ 10 4.2 Probe ................................................................................................................................................................. 10 4.3 Probe Calibration Process ................................................................................................................................. 12 4.4 Phantom ............................................................................................................................................................ 13 4.5 Device Holder .................................................................................................................................................... 13 4.6 Test Equipment List ........................................................................................................................................... 14 5. Tissue Simulating Liquids ....................................................................................................................................... 15 5.1 Composition of Tissue Simulating Liquid ........................................................................................................... 15 5.2 Tissue Dielectric Parameters for Head and Body Phantoms ............................................................................. 16 5.3 Tissue Calibration Result ................................................................................................................................... 17 6. SAR Measurement Evaluation ................................................................................................................................ 18 6.1 Purpose of System Performance Check ............................................................................................................ 18 6.2 System Setup .................................................................................................................................................... 18 6.3 Validation Results .............................................................................................................................................. 19 7. EUT Testing Position ............................................................................................................................................... 21 7.1 EUT Antenna Position ....................................................................................................................................... 21 7.2 EUT Testing Position ...............................β¦
Text truncated - open the document above for the full version.
Reference No.: WTX19X09063044W Page 81 of 160 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn MEASUREMENT 4 For Head Liquid Type: Validation measurement (Fast, 75.00 %) Measurement duration: 12 minutes 21 seconds E-field Probe: SSE2 - SN 45/15 EPGO280; ConvF: Refer to the Calibration Certificate; Calibrated: 2019/07/08 A. Experimental conditions Area Scan dx=8mm dy=8mm Zoom Scan dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Dipole Band CW1900 Signal Duty Cycle 1:1 B. SAR Measurement Results Frequency (MHz) 1900.000000 Relative Permittivity (real part) 38.560124 Conductivity (S/m) 1.380369 Power Variation (%) 1.022540 Ambient Temperature 21.1 Liquid Temperature 21.3 SURFACE SAR VOLUME SAR Reference No.: WTX19X09063044W Page 82 of 160 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Maximum location: X=0.00, Y=0.00 SAR 10g (W/Kg) 7.174526 SAR 1g (W/Kg) 9.913214 Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.0000 10.2354 6.8400 5.0121 4.1189 3.0522 2.8424 3D screen shot Hot spot position Reference No.: WTX19X09063044W Page 83 of 160 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn MEASUREMENT 5 For Head Liquid Type: Validation measurement (Fast, 75.00 %) Date of measurement: 04/18/2019 E-field Probe: SSE2 - SN 45/15 EPGO280; ConvF: Refer to the Calibration Certificate; Calibrated: 2019/07/08 A. Experimental conditions Area Scan dx=8mm dy=8mm Zoom Scan dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Dipole Band CW2450 Signal Duty Cycle 1:1 B. SAR Measurement Results Frequency (MHz) 2450.000000 Relative Permittivity (real part) 38.153660 Conductivity (S/m) 1.740236 Power Variation (%) 1.141452 Ambient Temperature 21.1 Liquid Temperature 21.2 SURFACE SAR VOLUME SAR Reference No.: WTX19X09063044W Page 84 of 160 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Maximum location: X=0.00, Y=0.00 SAR 10g (W/Kg) 8.020427 SAR 1g (W/Kg) 13.452457 Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.0000 14.1034 12.0012 10.2624 7.4715 5.9022 4.5114 3D screen shot Hot spot position Reference No.: WTX19X09063044W Page 85 of 160 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn MEASUREMENT 6 For Head Liquid Type: Validation measurement (Fast, 75.00 %) Measurement duration: 12 minutes 21 seconds E-field Probe: SSE2 - SN 45/15 EPGO280; ConvF: Refer to the Calibration Certificate; Calibrated: 2019/07/08 A. Experimental conditions Area Scan dx=8mm dy=8mm Zoom Scan dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Dipole Band CW2600 Signal Duty Cycle 1:1 B. SAR Measurement Results Frequency (MHz) 2600.000000 Relative Permittivity (real part) 38.631092 Conductivity (S/m) 1.930182 Power Variation (%) 1.028221 Ambient Temperature 21.1 Liquid Temperature 21.2 SURFACE SAR VOLUME SAR Reference No.: WTX19X09063044W Page 86 of 160 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Maximum location: X=0.00, Y=0.00 SAR 10g (W/Kg) 8.270822 SAR 1g (W/Kg) 13.670282 Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.0000 14.0426 12.1354 10.2965 7.4854 5.9354 4.5186 3D screen shot Hot spot position Reference No.: WTX19X09063044W Page 87 of 160 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn MEASUREMENT 7 For Body Liquid Type: Validation measurement (Fast, 75.00 %) Measurement duration: 12 minutes 21 seconds E-field Probe: SSE2 - SN 45/15 EPGO280; ConvF: Refer to the Calibration Certificate; Calibrated: 2019/07/08 A. Experimental conditions Area Scan dx=8mm dy=8mm Zoom Scan dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Dipole Band CW750 Signal Duty Cycle 1:1 B. SAR Measurement Results Frequency (MHz) 750.000000 Relative Permittivity (real part) 54.964739 Conductivity (S/m) 0.931048 Power Variation (%) 0.034745 Ambient Temperature 21.1 Liquid Temperature 21.3 SURFACE SAR VOLUME SAR Reference No.: WTX19X09063044W Page 88 of 160 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Maximum location: X=0.00, Y=0.00 SAR 10g (W/Kg) 1.000865 SAR 1g (W/Kg) 2.124211 Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.0000 2.5132 1.1087 0.8214 0.5160 0.4875 0.4864 3D screen shot Hot spot position Reference No.: WTX19X09063044W Page 89 of 160 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn MEASUREMENT 8 For Body Liquid Type: Validation measurement (Fast, 75.00 %) Measurement duration: 12 minutes 21 seconds E-field Probe: SSE2 - SN 45/15 EPGO280; ConvF: Refer to the Calibration Certificate; Calibrated: 2019/07/08 A. Experimental conditions Area Scan dx=8mm dy=8mm Zoom Scan dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Dipole Band CW835 Signal Duty Cycle 1:1 B. SAR Measurement Results Frequency (MHz) 835.000000 Relative Permittivity (real part) 54.851214 Conductivity (S/m) 0.951454 Power Variation (%) 0.901472 Ambient Temperature 21.1 Liquid Temperature 21.3 SURFACE SAR VOLUME SAR Reference No.: WTX19X09063044W Page 90 of 160 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Maximum location: X=0.00, Y=0.00 SAR 10g (W/Kg) 1.028956 SAR 1g (W/Kg) 2.354211 Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.0000 2.5789 1.1300 0.8795 0.5940 0.5011 0.5100 3D screen shot Hot spot position Reference No.: WTX19X09063044W Page 91 of 160 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn MEASUREMENT 9 For Body Liquid Type: Validation measurement (Fast, 75.00 %) Measurement duration: 12 minutes 21 seconds E-field Probe: SSE2 - SN 45/15 EPGO280; ConvF: Refer to the Calibration Certificate; Calibrated: 2019/07/08 A. Experimental conditions Area Scan dx=8mm dy=8mm Zoom Scan dx=8mm dy=8mm dz=5mm Phantom Validation plane Device Position Dipole Band CW1800 Signal CW (Crest factor: 1.0) B. SAR Measurement Results Frequency (MHz) 1800.000000 Relative Permittivity (real part) 51.224510 Conduβ¦
Text truncated - open the document above for the full version.
Reference No.: WTX19X09063044W-2 Page 1 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Appendix for Band 2 Product Name: Intelligent Two Way Radio Model No: T640A Reference No.: WTX19X09063044W-2 Page 2 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Appendix A: Average Power Output Data Test Result Channel Bandwidth: 1.4 MHz Modulati on Channel RB Configuration Average Power [dBm]Verdict Size Offset QPSK LCH 1 0 23.84 PASS 1 3 23.95 PASS 1 5 23.84 PASS 3 0 23.97 PASS 3 2 23.99 PASS 3 3 23.95 PASS 6 0 22.99 PASS MCH 1 0 23.37 PASS 1 3 23.47 PASS 1 5 23.33 PASS 3 0 23.39 PASS 3 2 23.40 PASS 3 3 23.38 PASS 6 0 22.51 PASS HCH 1 0 23.58 PASS 1 3 23.72 PASS 1 5 23.59 PASS 3 0 23.67 PASS 3 2 23.71 PASS 3 3 23.69 PASS 6 0 22.65 PASS 16QAM LCH 1 0 23.19 PASS 1 3 23.19 PASS 1 5 23.16 PASS 3 0 23.17 PASS 3 2 23.16 PASS 3 3 23.14 PASS 6 0 21.93 PASS MCH 1 0 22.63 PASS 1 3 22.81 PASS 1 5 22.63 PASS 3 0 22.38 PASS 3 2 22.45 PASS 3 3 22.38 PASS Reference No.: WTX19X09063044W-2 Page 3 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn 6 0 21.36 PASS HCH 1 0 22.80 PASS 1 3 22.97 PASS 1 5 22.75 PASS 3 0 22.76 PASS 3 2 22.72 PASS 3 3 22.73 PASS 6 0 21.83 PASS Channel Bandwidth: 3 MHz Modulation Channel RB Configuration Average Power [dBm]Verdict Size Offset QPSK LCH 1 0 23.90 PASS 1 7 24.11 PASS 1 14 23.85 PASS 8 0 23.00 PASS 8 4 22.98 PASS 8 7 22.98 PASS 15 0 22.96 PASS MCH 1 0 23.40 PASS 1 7 23.68 PASS 1 14 23.37 PASS 8 0 22.48 PASS 8 4 22.52 PASS 8 7 22.51 PASS 15 0 22.40 PASS HCH 1 0 23.64 PASS 1 7 23.91 PASS 1 14 23.64 PASS 8 0 22.62 PASS 8 4 22.66 PASS 8 7 22.62 PASS 15 0 22.59 PASS 16QAM LCH 1 0 23.23 PASS 1 7 23.39 PASS 1 14 23.14 PASS 8 0 22.04 PASS 8 4 22.04 PASS 8 7 21.95 PASS 15 0 21.90 PASS MCH 1 0 22.71 PASS Reference No.: WTX19X09063044W-2 Page 4 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn 1 7 22.87 PASS 1 14 22.69 PASS 8 0 21.40 PASS 8 4 21.39 PASS 8 7 21.36 PASS 15 0 21.37 PASS HCH 1 0 22.84 PASS 1 7 23.09 PASS 1 14 22.83 PASS 8 0 21.65 PASS 8 4 21.72 PASS 8 7 21.67 PASS 15 0 21.69 PASS Channel Bandwidth: 5 MHz Modulation Channel RB Configuration Average Power [dBm]Verdict Size Offset QPSK LCH 1 0 23.91 PASS 1 12 24.15 PASS 1 24 23.73 PASS 12 0 22.92 PASS 12 6 22.94 PASS 12 13 22.87 PASS 25 0 22.96 PASS MCH 1 0 23.34 PASS 1 12 23.64 PASS 1 24 23.31 PASS 12 0 22.55 PASS 12 6 22.67 PASS 12 13 22.79 PASS 25 0 22.43 PASS HCH 1 0 23.60 PASS 1 12 23.94 PASS 1 24 23.62 PASS 12 0 22.56 PASS 12 6 22.65 PASS 12 13 22.6 PASS 25 0 22.62 PASS 16QAM LCH 1 0 23.2 PASS 1 12 23.43 PASS 1 24 23.02 PASS Reference No.: WTX19X09063044W-2 Page 5 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn 12 0 22.01 PASS 12 6 22.01 PASS 12 13 21.96 PASS 25 0 21.95 PASS MCH 1 0 22.57 PASS 1 12 22.87 PASS 1 24 22.53 PASS 12 0 21.5 PASS 12 6 21.52 PASS 12 13 21.53 PASS 25 0 21.38 PASS HCH 1 0 22.69 PASS 1 12 23.1 PASS 1 24 22.74 PASS 12 0 21.7 PASS 12 6 21.77 PASS 12 13 21.72 PASS 25 0 21.78 PASS Channel Bandwidth: 10 MHz Modulation Channel RB Configuration Average Power [dBm]Verdict Size Offset QPSK LCH 1 0 23.86 PASS 1 24 23.90 PASS 1 49 23.58 PASS 25 0 22.93 PASS 25 12 22.91 PASS 25 25 22.85 PASS 50 0 22.84 PASS MCH 1 0 23.39 PASS 1 24 23.52 PASS 1 49 23.27 PASS 25 0 22.48 PASS 25 12 22.45 PASS 25 25 22.41 PASS 50 0 22.39 PASS HCH 1 0 23.51 PASS 1 24 23.76 PASS 1 49 23.64 PASS 25 0 22.70 PASS 25 12 22.59 PASS Reference No.: WTX19X09063044W-2 Page 6 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn 25 25 22.67 PASS 50 0 22.62 PASS 16QAM LCH 1 0 23.24 PASS 1 24 23.23 PASS 1 49 22.91 PASS 25 0 21.93 PASS 25 12 21.88 PASS 25 25 21.87 PASS 50 0 21.86 PASS MCH 1 0 22.75 PASS 1 24 22.82 PASS 1 49 22.67 PASS 25 0 21.45 PASS 25 12 21.40 PASS 25 25 21.38 PASS 50 0 21.40 PASS HCH 1 0 22.57 PASS 1 24 22.92 PASS 1 49 22.79 PASS 25 0 21.78 PASS 25 12 21.69 PASS 25 25 21.74 PASS 50 0 21.72 PASS Channel Bandwidth: 15 MHz Modulation Channel RB Configuration Average Power [dBm]Verdict Size Offset QPSK LCH 1 0 23.83 PASS 1 37 23.80 PASS 1 74 23.33 PASS 37 0 22.91 PASS 37 18 22.86 PASS 37 38 22.75 PASS 75 0 22.83 PASS MCH 1 0 23.29 PASS 1 37 23.70 PASS 1 74 23.22 PASS 37 0 22.54 PASS 37 18 22.57 PASS 37 38 22.52 PASS 75 0 22.57 PASS Reference No.: WTX19X09063044W-2 Page 7 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn HCH 1 0 23.41 PASS 1 37 23.85 PASS 1 74 23.51 PASS 37 0 22.73 PASS 37 18 22.72 PASS 37 38 22.61 PASS 75 0 22.72 PASS 16QAM LCH 1 0 23.13 PASS 1 37 23.19 PASS 1 74 22.67 PASS 37 0 21.86 PASS 37 18 21.82 PASS 37 38 21.67 PASS 75 0 21.82 PASS MCH 1 0 22.65 PASS 1 37 22.80 PASS 1 74 22.55 PASS 37 0 21.50 PASS 37 18 21.50 PASS 37 38 21.44 PASS 75 0 21.44 PASS HCH 1 0 22.56 PASS 1 37 22.73 PASS 1 74 22.73 PASS 37 0 21.69 PASS 37 18 21.70 PASS 37 38 21.68 PASS 75 0 21.70 PASS Channel Bandwidth: 20 MHz Modulation Channel RB Configuration Average Power [dBm]Verdict Size Offset QPSK LCH 1 0 23.70 PASS 1 49 24.16 PASS 1 99 23.20 PASS 50 0 22.78 PASS 50 25 22.75 PASS 50 50 22.57 PASS 100 0 22.67 PASS MCH 1 0 23.17 PASS 1 49 23.60 PASS Reference No.: WTX19X09063044W-2 Page 8 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn 1 99 23.08 PASS 50 0 22.37 PASS 50 25 22.42 PASS 50 50 22.36 PASS 100 0 22.36 PASS HCH 1 0 23.05 PASS 1 49 23.59 PASS 1 99 23.24 PASS 50 0 22.36 PASS 50 25 22.51 PASS 50 50 22.36 PASS 100 0 22.35 PASS 16QAM LCH 1 0 22.95 PASS 1 49 23.11 PASS 1 99 22.46 PASS 50 0 21.71 PASS 50 25 21.76 PASS 50 50 21.54 PASS 100 0 21.64 PASS MCH 1 0 22.64 PASS 1 49 22.90 PASS 1 99 22.53 PASS 50 0 21.39 PASS 50 25 21.43 PASS 50 50 21.37 PASS 100 0 21.28 PASS HCH 1 0 22.45 PASS 1 49 22.68 PASS 1 99 22.52 PASS 50 0 21.45 PASS 50 25 21.56 PASS 50 50 21.45 PASS 100 0 21.42 PASS Reference No.: WTX19X09063044W-2 Page 9 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Appendix B: Peak-to-Average Ratio Test Resulβ¦
Text truncated - open the document above for the full version.
Reference No.: WTX19X09063044W-2 Page 60 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 10 MHz_MCH_QPSK_1RB#0 Channel Bandwidth: 10 MHz_MCH_QPSK_1RB#24 Channel Bandwidth: 10 MHz_MCH_QPSK_1RB#49 Reference No.: WTX19X09063044W-2 Page 61 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 10 MHz_MCH_QPSK_25RB#0 Channel Bandwidth: 10 MHz_MCH_QPSK_25RB#12 Channel Bandwidth: 10 MHz_MCH_QPSK_25RB#25 Reference No.: WTX19X09063044W-2 Page 62 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 10 MHz_MCH_QPSK_50RB#0 Channel Bandwidth: 10 MHz_HCH_QPSK_1RB#0 Channel Bandwidth: 10 MHz_HCH_QPSK_1RB#24 Reference No.: WTX19X09063044W-2 Page 63 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 10 MHz_HCH_QPSK_1RB#49 Channel Bandwidth: 10 MHz_HCH_QPSK_25RB#0 Channel Bandwidth: 10 MHz_HCH_QPSK_25RB#12 Reference No.: WTX19X09063044W-2 Page 64 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 10 MHz_HCH_QPSK_25RB#25 Channel Bandwidth: 10 MHz_HCH_QPSK_50RB#0 Reference No.: WTX19X09063044W-2 Page 65 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 10 MHz_LCH_16QAM_1RB#0 Channel Bandwidth: 10 MHz_LCH_16QAM_1RB#24 Channel Bandwidth: 10 MHz_LCH_16QAM_1RB#49 Channel Bandwidth: 10 MHz_LCH_16QAM_25RB#0 Reference No.: WTX19X09063044W-2 Page 66 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 10 MHz_LCH_16QAM_25RB#12 Channel Bandwidth: 10 MHz_LCH_16QAM_25RB#25 Channel Bandwidth: 10 MHz_LCH_16QAM_50RB#0 Reference No.: WTX19X09063044W-2 Page 67 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 10 MHz_MCH_16QAM_1RB#0 Channel Bandwidth: 10 MHz_MCH_16QAM_1RB#24 Channel Bandwidth: 10 MHz_MCH_16QAM_1RB#49 Reference No.: WTX19X09063044W-2 Page 68 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 10 MHz_MCH_16QAM_25RB#0 Channel Bandwidth: 10 MHz_MCH_16QAM_25RB#12 Channel Bandwidth: 10 MHz_MCH_16QAM_25RB#25 Reference No.: WTX19X09063044W-2 Page 69 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 10 MHz_MCH_16QAM_50RB#0 Channel Bandwidth: 10 MHz_HCH_16QAM_1RB#0 Channel Bandwidth: 10 MHz_HCH_16QAM_1RB#24 Reference No.: WTX19X09063044W-2 Page 70 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 10 MHz_HCH_16QAM_1RB#49 Channel Bandwidth: 10 MHz_HCH_16QAM_25RB#0 Channel Bandwidth: 10 MHz_HCH_16QAM_25RB#12 Reference No.: WTX19X09063044W-2 Page 71 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 10 MHz_HCH_16QAM_25RB#25 Channel Bandwidth: 10 MHz_HCH_16QAM_50RB#0 Reference No.: WTX19X09063044W-2 Page 72 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 15 MHz (Channel Bandwidth:15 MHz)_LCH_QPSK_1RB#0 (Channel Bandwidth:15 MHz)_LCH_QPSK_1RB#37 (Channel Bandwidth:15 MHz)_LCH_QPSK_1RB#74 (Channel Bandwidth:15 MHz)_LCH_QPSK_37RB#0 Reference No.: WTX19X09063044W-2 Page 73 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn (Channel Bandwidth:15 MHz)_LCH_QPSK_37RB#18 (Channel Bandwidth:15 MHz)_LCH_QPSK_37RB#38 (Channel Bandwidth:15 MHz)_LCH_QPSK_75RB#0 Reference No.: WTX19X09063044W-2 Page 74 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn (Channel Bandwidth:15 MHz)_MCH_QPSK_1RB#0 (Channel Bandwidth:15 MHz)_MCH_QPSK_1RB#37 (Channel Bandwidth:15 MHz)_MCH_QPSK_1RB#74 Reference No.: WTX19X09063044W-2 Page 75 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn (Channel Bandwidth:15 MHz)_MCH_QPSK_37RB#0 (Channel Bandwidth:15 MHz)_MCH_QPSK_37RB#18 (Channel Bandwidth:15 MHz)_MCH_QPSK_37RB#38 Reference No.: WTX19X09063044W-2 Page 76 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn (Channel Bandwidth:15 MHz)_MCH_QPSK_75RB#0 (Channel Bandwidth:15 MHz)_HCH_QPSK_1RB#0 (Channel Bandwidth:15 MHz)_HCH_QPSK_1RB#37 Reference No.: WTX19X09063044W-2 Page 77 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn (Channel Bandwidth:15 MHz)_HCH_QPSK_1RB#74 (Channel Bandwidth:15 MHz)_HCH_QPSK_37RB#0 (Channel Bandwidth:15 MHz)_HCH_QPSK_37RB#18 Reference No.: WTX19X09063044W-2 Page 78 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn (Channel Bandwidth:15 MHz)_HCH_QPSK_37RB#38 (Channel Bandwidth:15 MHz)_HCH_QPSK_75RB#0 Reference No.: WTX19X09063044W-2 Page 79 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn (Channel Bandwidth:15 MHz)_LCH_16QAM_1RB#0 (Channel Bandwidth:15 MHz)_LCH_16QAM_1RB#37 (Channel Bandwidth:15 MHz)_LCH_16QAM_1RB#74 (Channel Bandwidth:15 MHz)_LCH_16QAM_37RB#0 Reference No.: WTX19X09063044W-2 Page 80 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn (Channel Bandwidth:15 MHz)_LCH_16QAM_37RB#18 (Channel Bandwidth:15 MHz)_LCH_16QAM_37RB#38 (Channel Bandwidth:15 MHz)_LCH_16QAM_75RB#0 Reference No.: WTX19X09063044W-2 Page 81 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn (Channel Bandwidth:15 MHz)_MCH_16QAM_1RB#0 (Channel Bandwidth:15 MHz)_MCH_16QAM_1RB#37 (Channel Bandwidth:15 MHz)_MCH_16QAM_1RB#74 Reference No.: WTX19X09063044W-2 Page 82 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn (Channel Bandwidth:15 MHz)_MCH_16QAM_37RB#0 (Channel Bandwidth:15 MHz)_MCH_16QAM_37RB#18 (Channel Bandwidth:15 MHz)_MCH_16QAM_37RB#38 Reference No.: WTX19X09063044W-2 Page 83 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn (Channel Bandwidth:15 MHz)_MCH_16QAM_75RB#0 (Channel Bandwidth:15 MHz)_HCH_16QAM_1RB#0 (Channel Bandwidth:15 MHz)_HCH_16QAM_1RB#37 Reference No.: WTX19X09063044W-2 Page 84 of 283 Waltek Testing Group (Shenzhen) Co.β¦
Text truncated - open the document above for the full version.
Reference No.: WTX19X09063044W-2 Page 107 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn (Channel Bandwidth: 5 MHz)_LCH_16QAM_25RB#0 (Channel Bandwidth: 5 MHz)_MCH_16QAM_25RB#0 (Channel Bandwidth: 5 MHz)_HCH_16QAM_25RB#0 Reference No.: WTX19X09063044W-2 Page 108 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 10 MHz Channel Bandwidth: 10 MHz_LCH_QPSK_50RB#0 Channel Bandwidth: 10 MHz_MCH_QPSK_50RB#0 Channel Bandwidth: 10 MHz_HCH_QPSK_50RB#0 Reference No.: WTX19X09063044W-2 Page 109 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidth: 10 MHz_LCH_16QAM_50RB#0 Channel Bandwidth: 10 MHz_MCH_16QAM_50RB#0 Channel Bandwidth: 10 MHz_HCH_16QAM_50RB#0 Reference No.: WTX19X09063044W-2 Page 110 of 283 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Channel Bandwidthβ¦
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 32 | 27 | 709 MHz - 711 MHz | 87.70 mW | 8M94W7D | 0.0068 ppm |

4G LTE Terminal
Equipment Class
DTS - Digital Transmission System
PoC Radio
Equipment Class
PCF - PCS Licensed Transmitter held to face
Wireless RSM
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
SMART MULTI-MODE RADIO
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Wireless RSM
Equipment Class
DTS - Digital Transmission System