FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Inrico Technologies Co.,Ltd/
  3. 2AIV6-T710A

2AIV6-T710APoC RADIO

Inrico Technologies Co.,Ltd
PoC RADIO - FCC ID 2AIV6-T710A - Inrico Technologies Co.,Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 18, 2023
Application Purpose
Original Equipment
Date of Application
Apr 18, 2023
Equipment Note
PoC RADIO
Frequency Range
2412.00000000 - 2462.00000000
Company
Inrico Technologies Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

www.inricosolutions.com Please read this instruction book carefully before using and keep this with care. T710A USER GUIDE PoC RADIO Professional In High Quality Two Way Radios INRICO TECHNOLOGIES CO., LTD. www.inricosolutions.com Please read the following content carefully. It is very important for radio users to gain general knowledge and risks. ● Do not use the device or charging the battery in any hazardous areas such as gas, dust, steam, etc. ● Please turn off the device while refueling or parking at the gas station. ● Do not disassemble your radio. ● Avoid prolonged time in the sun or placing it near heating appliance. ● Avoid excessive exposure to the extreme dusty, damp and splashing place, or leave it on unstable surface. ● Reparation by professional technicians, do not disassemble by yourself. Notes Before Using 01 Unpacking and Device Checking Please unpack and take out the device and all accessories carefully, and ensure all lists have been gotten before discarding the cardboard box. If any items are lost or damaged in transit, please contact with our distributors. PoC Radio Lithium Battery Power Adaptor USB Charging Cable Belt Clip Hand Strip User Manual 1 1 1 1 1 1 1 ItemsNumber Accessories Contents 01 01 02 03 03 03 03 04 05 06 06 06 07 07 07 08 08 08 08 08 08 09 09 09 10 11 12 13 Unpacking and Device Checking.................................. Accessories.................................................................. Handling Precautions................................................... Battery Care.................................................................. Fully Charge Battery Before Initial Use....................... Properly Store Batteries............................................. Features of Lithium Battery ....................................... Clean and Maintenance............................................ Product Overview......................................................... Accessories Installation............................................... Insert SIM Card ........................................................ Attaching the Battery................................................. Attaching the Battery Cover....................................... Removing the Battery Cover....................................... Attaching Headset.................................................... Install Hand Strip....................................................... Basic Functions............................................................ Power On/Off............................................................. User Log-in................................................................ Initiate a Call............................................................. Program.................................................................... Network Connecting.................................................... Wi-Fi Connecting....................................................... Bluetooth Connecting................................................ Status Indicators.......................................................... Simple Troubleshooting............................................... Specification................................................................ FCC Caution................................................................. 03 02 Handling Precautions ● Do not overcharge the battery Please stop charging if it can’t be fully charged within required time. The battery probably overheats, smokes, bursts or suddenly be on fire due to abnormal charging process. When fully charged or not charged, please disconnect the charger and unplug it from the power outlet. ● Do not discard battery in a microwave or high pressure container. The battery probably overheats, smokes, bursts or suddenly be on fire. ● Do not expose damaged battery near any fire. If the battery is broken, leaking or has an abnormal odor, please remove it from flammable areas immediately. The fluid in the battery is flammable, which may cause smoke and fire. ● Do not use abnormal battery If the battery is with odd smelly, discolored, deformed, etc., please stop charging or disassemble from the device immediately. ● Please use authorized power adaptor To comply with warranty terms and avoid damages, charge the battery using a specified charger for best performance. Battery Care Fully Charge Battery Before Initial Use ● Do preserve battery life by switching off a device and removing the batteries when it's not being used, and is not expected to be used for extended periods of time. ● Do practice proper battery storage by keeping batteries in a cool, dry place at normal room temperature. Properly Store Batteries ● Remove the battery from the device. ● Charge and discharge the battery to 40%-65% if it will not be used for 10 days or more. This can greatly extend the battery life. ● The battery should drop below 65% when it is idle for more than 10 days to prevent it from swelling. ● Store the battery in cool and dry environment that’s less than 25°C. Features of Lithium Battery ● Battery capacity will reduce after multiple charging cycles. ● The battery capacity drops gradually even without being used. ● Longer charging time is required in shady place. ● Charging and storing lithium battery in warm condition will short its lifespan. Please do not leave them inside the vehicle or near the heater. ● If the battery working time has reduced significantly, please replace the battery immediately in avoidance of fluid leakage. 14 04 05 Product Overview OK UPDown Power PTT F1 F2 Clean and Maintenance ● Before cleaning and maintaining the device: please stop running, turn off the device, and disconnect all connections with other equipment. ● When you do not use the radio, please cover the accessories connector. ● When cleaning the dust, please use soft brush and neutral detergent (no strong corrosive chemicals) to wipe it. ● Please keep the equipment and accessories dry. ● Please do not use th…

Text truncated - open the document above for the full version.

Attestation Statements

Inrico Technologies Co.,Ltd Address:A1703, Shenzhen National Engineering Laboratory Building, No. 20 Gaoxin South 7th Road , Shenzhen,China Tel: 0755-83273589 Email: [email protected] Date: 2023/02/10 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir/Madam, We, Inrico Technologies Co.,Ltd, hereby authorize China Certification ICT Co., Ltd (Dongguan) to act as a laboratory for testing and test report generation for the following project(s): (Product description: PoC RADIO, model name: T710A, FCC ID: 2AIV6-T710A) declare that the device does not support channel 12-13 in 2.4 GHz band and any non-US channels Sincerely Yours, Client's signature Wenshun Zhang Manager

Attestation Statements

Inrico Technologies Co.,Ltd Address:A1703, Shenzhen National Engineering Laboratory Building, No. 20 Gaoxin South 7th Road , Shenzhen,China Tel: 0755-83273589 Email: [email protected] CFR 47 §2.911(d)(5)(i) Attestation Letter Attestation Letter Date: 2023-2- 10 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID: 2AIV6-T710A Inrico Technologies Co.,Ltd certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Signature Wenshun Zhang Manager

Attestation Statements

Inrico Technologies Co.,Ltd Address:A1703, Shenzhen National Engineering Laboratory Building, No. 20 Gaoxin South 7th Road , Shenzhen,China Tel: 0755-83273589 Email: [email protected] CFR 47 §2.911 (d)(5)(ii) Attestation Letter Attestation Letter Date: 2023-2- 10 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID: 2AIV6-T710A Inrico Technologies Co.,Ltd certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature Wenshun Zhang Manager

Attestation Statements

Inrico T Add:A1 Road, S Tel: 075 Email: Date: 2 0 FEDER Authori 7435 O Colum b Ref : A t FC C I D Inrico T the Unit The ap p after the related p Echo91 of the d Desi gn a Name: E Address Tel.: +1 Email:w Signed Signat u Applic a Add:A1 Road, S FRN: 0 Tel: 07 5 Email: Signed Signat u Technologie 1703, Shenz Shenzhen, C 55-8327358 sales@inric C 023-02-10 RAL COMM ization and akland Mil l bia, MD 210 ttestation St D: 2AIV6-T Technologies ted States, fo licant acknow e grantee has proceeding i 11, LLC(U. designated U ated U.S. A Echo911, L s: 1004 Oste 1 (205) 370 4 warren@echo by (printed ure: ant: Inrico T 1703, Shenz Shenzhen, C 025688870 55-8327358 sales@inric by (printed ure: s Co.,Ltd zhen Nation China 89 cosolutions. CFR 47 §2 MUNICATI Evaluation ls Road 046 tatements C 710A Co.,Ltd as re or purposes o wledgesthe a s terminated involving th .S. agent) ac U.S. agent fo Agent Inform LLC er Drive NW 4346 o911.com name): War Technologie zhen Nation China 89 cosolutions. name): W e nal Engineer com 2.911(d)(7 IONS COM Division FR 47 §2.9 equired by se of acting as th applicant’s a d all marketi he equipmen ccepts, as o for service o mation: , Suite C, Hu rren Sandusk es Co.,Ltd nal Engineer com enshun Zhan ring Labora 7)Agent D MMISSIONS 11(d)(7) Fil ection 2.911 he applicant’ acceptance t ing and impo nt. f the date of of process fo untsville AL ky ring Labora ng atory Buildi Designatio S ling (d)(7), desig ’s agent for s to maintain a ortation or th f the filing o or the above 35816 atory Buildi ing, No. 20 CFR on Attesta gnates the fol service of pro an agent for he conclusio of the appli e referenced ing, No. 20 Gaoxin So u 47 §2.911(d) ation llowing agen ocess. r no less than on of any Co cation, the o d FCC ID. Gaoxin So u uth 7th (7) U.S Agent nt, located in n one year ommission- obligation uth 7th t

Cover Letter(s)

Inrico Technologies Co.,Ltd Address:A1703, Shenzhen National Engineering Laboratory Building, No. 20 Gaoxin South 7th Road , Shenzhen, China Tel: 0755-83273589 Email: [email protected] QA-FR-170-B 7/29/2014 FCC Authorization Date: 2023-2- 10 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We Inrico Technologies Co.,Ltd, the undersigned, hereby authorizes China Certification ICT Co., Ltd (Dongguan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by China Certification ICT Co., Ltd (Dongguan) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Wenshun Zhang Manager

Cover Letter(s)

Inrico Technologies Co.,Ltd Address:A1703, Shenzhen National Engineering Laboratory Building, No. 20 Gaoxin South 7th Road , Shenzhen,China Tel: 0755-83273589 Email: [email protected] FCC Confidential Authorization Date: 2023-2-10 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AIV6-T710A In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Inrico Technologies Co.,Ltd hereby requests long-term confidential treatment of information accompanying this application as outlined below: • Block Diagram • Schematics • Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours Signature: Wenshun Zhang Manager • Parts List/Tune up procedure (for licensed devices)

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS

ID Label/Location Info

label Label location

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS uncover battery WiFi/BLE/GPS Antenna GSM/WCDMA/LTE Main Antenna LTE DIV Antenna chip chip chip chip chip NFC Antenna

RF Exposure Info

Report No.: CR221259137-20 Page 1 of 2 APPENDIX B EUT TEST POSITION PHOTOS Liquid depth ≥ 15cm Phantom: Twin SAM; Type: Twin SAM V5.0; Serial: TP:1412 Report No.: CR221259137-20 Page 2 of 2 Face Up Setup Photo (10mm) Body Back Setup Photo (0mm) 10 mm

RF Exposure Info

APPENDIX C PROBE CALIBRATION CERTIFICATES DIPOLE CALIBRATION CERTIFICATES

RF Exposure Info

SAR TEST REPORT Applicant: Inrico Technologies Co.,Ltd Address: A1703, Shenzhen National Engineering Laboratory Building, No. 20 Gaoxin South 7th Road, Shenzhen, China FCC ID: 2AIV6-T710A Product Name: PoC RADIO Model Number: T710A Standard(s): 47 CFR Part 2(2.1093) The above equipment has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR221259137-20 Date Of Issue: 2023-02-10 Reviewed By: Karl Gong Title: SAR Engineer Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR221259137-20 Page 2 of 82 SAR TEST RESULTS SUMMARY Operation Frequency Bands Highest Reported 1g SAR (W/kg) Limits (W/kg) Face Up (Gap 10mm) Body SAR (Gap 0mm) GSM 850 0.710.52 1.6 PCS 1900 0.140.42 WCDMA Band 2 0.190.28 WCDMA Band 4 0.640.34 WCDMA Band 5 0.630.31 LTE Band 2 0.290.31 LTE Band 5 0.70.46 LTE Band 7 0.660.25 LTE Band 12&170.660.5 LTE Band 38 0.40.17 LTE Band 40 0.160.14 LTE Band 66&4 0.790.67 WLAN 2.4G 0.060.08 Maximum Simultaneous Transmission SAR Items Face Up (Gap 10mm) Body-Worn (Gap 0mm) Limits Sum SAR(W/kg) 0.87 0.82 1.6 SPLSR / / 0.04 EUT Received Date: 2022/12/16 Tested Date: 2022/12/27~2022/12/30 Tested Result: Pass China Certification ICT Co., Ltd (Dongguan) Report No.: CR221259137-20 Page 3 of 82 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0123. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. China Certification ICT Co., Ltd (Dongguan) Report No.: CR221259137-20 Page 4 of 82 CONTENTS SAR TEST RESULTS SUMMARY .............................................................................................. 2 TEST FACILITY .......................................................................................................................................... 3 DECLARATIONS .......................................................................................................................................... 3 DOCUMENT REVISION HISTORY .......................................................................................... 6 1. GENERAL INFORMATION .................................................................................................... 7 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 7 1.2 TEST SPECIFICATION, METHODS AND PROCEDURES ........................................................................ 8 1.3 SAR LIMTS ........................................................................................................................................... 9 2. SAR MEASUREMENT SYSTEM .......................................................................................... 10 3. EQUIPMENT LIST AND CALIBRATION .......................................................................... 17 3.1 EQUIPMENTS LIST & CALIBRATION INFORMATION ....................................................................... 17 4. SAR MEASUREMENT SYSTEM VERIFICATION ........................................................... 18 4.1 LIQUID VERIFICATION ...................................................................................................................... 18 4.2 SYSTEM ACCURACY VERIFICATION ................................................................................................. 21 4.3 SAR SYSTEM VALIDATION DATA ............................................................................................. 22 5. EUT TEST STRATEGY AND METHODOLOGY .............................................................. 29 5.1 TEST POSITIONS FOR DEVICE OPERATING NEXT TO A PERSON’S EAR ......................................... 29 5.2 CHEEK/TOUCH POSITION .................................................................................................................. 30 5.3 EAR/TILT POSITION ........................................................................................................................... 30 5.4 TEST POSITIONS FOR BODY-WORN AND OTHER CONFIGURATIONS ................................................ 31 5.5 TEST DISTANCE FOR SAR EVALUATION .......................................................................................... 32 5.6 SAR EVALUATION PROCEDURE ....................................................................................................... 33 6. CONDUCTED OUTPUT POWER MEASUREMENT ........................................................ 34 6.1 TEST PROCEDURE .............................................................................................................................. 34 6.2 DESCRIPTION OF TEST CONFIGURATION ..............................…

Text truncated - open the document above for the full version.

RF Exposure Info

Report No.: CR221259137-20 Page 1 of 46 Test Plot 1#: GSM 850_Face Up_Middle DUT: POC RADIO; Type: Y710A; Serial: 1TS5 Communication System: Generic GSM (0); Frequency: 836.6 MHz;Duty Cycle: 1:8 Medium parameters used: f = 836.6 MHz; σ = 0.903 S/m; ε r = 41.658; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration:  Probe: EX3DV4 - SN7522; ConvF(9.7, 9.7, 9.7) @ 836.6 MHz; Calibrated: 2022/5/6  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn1354; Calibrated: 2022/10/31  Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1412  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (6x12x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.900 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 26.58 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 1.05 W/kg SAR(1 g) = 0.667 W/kg; SAR(10 g) = 0.449 W/kg Maximum value of SAR (measured) = 0.890 W/kg 0 dB = 0.890 W/kg = -0.51 dBW/kg Report No.: CR221259137-20 Page 2 of 46 Test Plot 2#: GSM 850_Body Worn Back_Middle DUT: POC RADIO; Type: Y710A; Serial: 1TS5 Communication System: Generic GSM (0); Frequency: 836.6 MHz;Duty Cycle: 1:8 Medium parameters used: f = 836.6 MHz; σ = 0.903 S/m; ε r = 41.658; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration:  Probe: EX3DV4 - SN7522; ConvF(9.7, 9.7, 9.7) @ 836.6 MHz; Calibrated: 2022/5/6  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn1354; Calibrated: 2022/10/31  Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1412  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (6x12x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.654 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 23.96 V/m; Power Drift = -0.14 dB Peak SAR (extrapolated) = 0.767 W/kg SAR(1 g) = 0.491 W/kg; SAR(10 g) = 0.331 W/kg Maximum value of SAR (measured) = 0.663 W/kg 0 dB = 0.663 W/kg = -1.78 dBW/kg Report No.: CR221259137-20 Page 3 of 46 Test Plot 3#: GSM 850 _ Body Back_Middle DUT: POC RADIO; Type: Y710A; Serial: 1TS5 Communication System: Generic GPRS-3 slots (0); Frequency: 836.6 MHz;Duty Cycle: 1:2.66 Medium parameters used: f = 836.6 MHz; σ = 0.903 S/m; ε r = 41.658; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration:  Probe: EX3DV4 - SN7522; ConvF(9.7, 9.7, 9.7) @ 836.6 MHz; Calibrated: 2022/5/6  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn1354; Calibrated: 2022/10/31  Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1412  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (6x12x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.577 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 21.91 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 0.658 W/kg SAR(1 g) = 0.432 W/kg; SAR(10 g) = 0.296 W/kg Maximum value of SAR (measured) = 0.573 W/kg 0 dB = 0.573 W/kg = -2.42 dBW/kg Report No.: CR221259137-20 Page 4 of 46 Test Plot 4#: PCS 1900_Face Up_Middle DUT: POC RADIO; Type: Y710A; Serial: 1TS5 Communication System: Generic GSM (0); Frequency: 1880 MHz;Duty Cycle: 1:8 Medium parameters used: f = 1880 MHz; σ = 1.424 S/m; ε r = 39.659; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration:  Probe: EX3DV4 - SN7522; ConvF(7.79, 7.79, 7.79) @ 1880 MHz; Calibrated: 2022/5/6  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn1354; Calibrated: 2022/10/31  Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1412  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (6x12x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.167 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.612 V/m; Power Drift = -0.06 dB Peak SAR (extrapolated) = 0.194 W/kg SAR(1 g) = 0.120 W/kg; SAR(10 g) = 0.070 W/kg Maximum value of SAR (measured) = 0.167 W/kg 0 dB = 0.167 W/kg = -7.77 dBW/kg Report No.: CR221259137-20 Page 5 of 46 Test Plot 5#: PCS 1900_Body Worn Back_Middle DUT: POC RADIO; Type: Y710A; Serial: 1TS5 Communication System: Generic GSM (0); Frequency: 1880 MHz;Duty Cycle: 1:8 Medium parameters used: f = 1880 MHz; σ = 1.424 S/m; ε r = 39.659; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration:  Probe: EX3DV4 - SN7522; ConvF(7.79, 7.79, 7.79) @ 1880 MHz; Calibrated: 2022/5/6  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn1354; Calibrated: 2022/10/31  Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1412  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (6x12x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.506 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 6.556 V/m; Power Drift = 0.00 dB Peak SAR (extrapolated) = 0.647 W/kg SAR(1 g) = 0.354 W/kg; SAR(10 g) = 0.185 W/kg Maximum value of SAR (measured) = 0.517 W/kg 0 dB = 0.517 W/kg = -2.87 dBW/kg Report No.: CR221259137-20 Page 6 of 46 Test Plot 6#: PCS 1900_ Body Back_Middle DUT: POC RADIO; Type: Y710A; Serial: 1TS5 Communication System: Generic GPRS-3 slots (0); Frequency: 1880 MHz;Duty Cycle: 1:2.66 Medium parameters used: f = 1880 MHz; σ = 1.424 S/m; ε r = 39.659; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration:  Probe: EX3DV4 - SN7522; ConvF(7.79, 7.79, 7.79) @ 1880 MHz; Calibrated: 2022/5/6  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn1354; Calibrated: 2022/10/31  Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1412  Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12 (7470) Area Scan (6x12x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.435 W/kg Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Val…

Text truncated - open the document above for the full version.

Test Report

Antenna information: Antenna Name Model(s)/Type(s) Antenna 1 Model/Part Number: T710A Manufacturer: Shenzhen Anforte Electronics Co., LTD 3rd Floor, Building B, Hong Kong-Shenzhen Innovation Park, No. 40, Huoning Road, Dalang Street, Longhua District, Shenzhen Frequency Range: GSM/GPRS/EDGE: 850/1900 WCDMA:B2/4/5 FDD:B2/4/5/7/12/17/66 TDD:B38/40 Connector Type/ GSM850:0.3dBi;PCS1900: 0.8dBi WCDMA :B2:0.8dbi B4:0.8dbi B5:0.3dbi TDD :B2:0.8dbi B4: 0.8dbi B5:0.3dbi B7: 1dbi B12:0.1dbi B17:0.1dbi B66:0.8dbi FDD:B38:1dbi B40: 1dbi Maximum Gain Antenna Type/ Pattern: FPC Measurement: mm(57.41) x mm(18.69) x mm(0.12) Antenna 2 Model/Part Number: T710A Manufacturer: Shenzhen Anforte Electronics Co., LTD 3rd Floor, Building B, Hong Kong-Shenzhen Innovation Park, No. 40, Huoning Road, Dalang Street, Longhua District, Shenzhen Frequency Range: WIFI 2.4G ,GPS,BT Connector Type/ WIFI 2.4G/BT:1.4dbi GPS: 0.75dbi Maximum Gain Antenna Type/ Pattern: PCB Measurement: mm(23.26) x mm(15.4 ) x mm(0.12) Antenna 3 Model/Part Number: T710A Manufacturer: Shenzhen Anforte Electronics Co., LTD 3rd Floor, Building B, Hong Kong-Shenzhen Innovation Park, No. 40, Huoning Road, Dalang Street, Longhua District, Shenzhen Frequency Range: GSM/GPRS/EDGE: 850/1900 WCDMA:B2/4/5 FDD:B2/4/5/7/12/17/66 TDD:B38/40 Connector Type/ GSM850:0.3dBi;PCS1900: 0.8dBi Maximum Gain WCDMA:B2:0.8dbi B4:0.8dbi B5:0.3dbi TDD :B2:0.8dbi B4: 0.8dbi B5:0.3dbi B7: 1dbi B12:0.1dbi B17:0.1dbi B66:0.8dbi FDD:B38:1dbi B40: 1dbi Antenna Type/ Pattern: PCB Measurement: mm(44) x mm(21.97) x mm(0.12) Main antenna 700-960MHz Main antenna 1710-2690MHz Antenna 700-960MHz antenna 1710-2690MHz WiFi antenna 2400-2500MHz GPS antenna 1575.42MHz

Test Report

TEST REPORT Applicant: Inrico Technologies Co., Ltd Address: A1703, Shenzhen National Engineering Laboratory Building, No. 20 Gaoxin South 7th Road , Shenzhen,China FCC ID: 2AIV6-T710A Product Name: PoC RADIO Standard(s): 47 CFR Part 15, Subpart C(15.247) ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 The above equipment has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR221259137-00F Date Of Issue: 2023/2/27 Reviewed By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR221259137-00F Page 2 of 42 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0123. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. China Certification ICT Co., Ltd (Dongguan) Report No.: CR221259137-00F Page 3 of 42 CONTENTS T EST FACILITY .......................................................................................................................................... 2 DECLARATIONS .......................................................................................................................................... 2 DOCUMENT REVISION HISTORY .......................................................................................... 5 1. GENERAL INFORMATION .................................................................................................... 6 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 6 1.2 DESCRIPTION OF TEST CONFIGURATION ........................................................................................... 8 1.2.1 EUT Operation Condition: ............................................................................................................................. 8 1.2.2 Support Equipment List and Details .............................................................................................................. 8 1.2.3 Support Cable List and Details ...................................................................................................................... 8 1.2.4 Block Diagram of Test Setup ...........................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Wenshun Zhang(Manager)
[email protected]0755-83273589Fax: 0755-82689912

Test Firm

CHINA CERTIFICATION ICT CO., LTD (DONGGUAN)Tanie Ou
[email protected]0086 0769 86858888

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz19.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device supports 20 MHz and 40 MHz bandwidth modes. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly. SAR compliance for face up condition must provide a minimum separation distance of 10 mm between the device and face. The highest reported SAR for face up, body-worn accessory and simultaneous transmission exposure conditions are 0.06 W/kg, 0.08 W/kg and 0.85 W/kg, respectively.

Other Applications from Inrico Technologies Co.,Ltd

4G LTE Terminal - FCC ID 2AIV6-T740A - Inrico Technologies Co.,Ltd
2AIV6-T740A

4G LTE Terminal

Nov 26, 2025

Equipment Class

DTS - Digital Transmission System
PoC Radio - FCC ID 2AIV6-T521 - Inrico Technologies Co.,Ltd
2AIV6-T521

PoC Radio

Jul 31, 2024

Equipment Class

PCF - PCS Licensed Transmitter held to face
Wireless RSM - FCC ID 2AIV6-B06 - Inrico Technologies Co.,Ltd
2AIV6-B06

Wireless RSM

Jul 21, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
SMART MULTI-MODE RADIO - FCC ID 2AIV6-IRC380 - Inrico Technologies Co.,Ltd
2AIV6-IRC380

SMART MULTI-MODE RADIO

Jul 03, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless RSM - FCC ID 2AIV6-B05 - Inrico Technologies Co.,Ltd
2AIV6-B05

Wireless RSM

Jun 03, 2024

Equipment Class

DTS - Digital Transmission System