
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
The antenna of the product, under normal use condition is at least 0.2m away from the body of the user. For CE Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 25cm between the radiator& your body.
Telepower Communication Co., Ltd. 5 Bld, Zone A, Hantian Technology Town No.17 ShenHai RD, Nanhai District Foshan China Tel: 0757-86337898 Fax: 0757-86337898 Email: [email protected] CFR 47 §2.911(d)(5)(i) Attestation Letter Attestation Letter Date: 2024-07-19 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID: 2AJ2B-T10 Telepower Communication Co., Ltd. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Signature Mike Mai Product Director
Telepower Communication Co., Ltd. 5 Bld, Zone A, Hantian Technology Town No.17 ShenHai RD, Nanhai District Foshan China Tel: 0757-86337898 Fax: 0757-86337898 Email: [email protected] CFR 47 §2.911 (d)(5)(ii) Attestation Letter Attestation Letter Date: 2024-07-19 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID: 2AJ2B-T10 Telepower Communication Co., Ltd. (“the applicant”) certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature Mike Mai Product Director
U.S. AGENT LETTER OF ATTESTATION Date: 2024-07-19 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2AJ2B-T10 Telepower Communication Co., Ltd. certifies that, as of the date of the filing of the application, Iconsigh Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. Telepower Communication Co., Ltd. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Iconsigh Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Iconsigh Inc. Address: 2310 Homestead Road, Suite C1, Los Altos, CA, 94024, USA FRN: 0033398652 Tel.: +1 (408) 320-9867 Email: [email protected] Signed by (printed name): Benjamin Kaur Signature: Applicant: Telepower Communication Co., Ltd. Address: 5 Bld, Zone A, Hantian Technology Town No.17 ShenHai RD, Nanhai District Foshan China FRN: 0025951815 Tel: 0757-86337898 Email: [email protected] Signed by (printed name): Mike Mai Signature:
Telepower Communication Co., Ltd. 5 Bld, Zone A, Hantian Technology Town No.17 ShenHai RD, Nanhai District Foshan China Tel: 0757-86337898 Fax: 0757-86337898 Email: [email protected] FCC Confidential Authorization Date: 2024-07-19 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AJ2B-T10 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Telepower Communication Co., Ltd. hereby requests long-term confidential treatment of information accompanying this application as outlined below: Block Diagram Schematics Operation Description Part list/Tune up Procedure Software Security Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature Mike Mai Product Director
Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 1 of 4 EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 2 of 4 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 3 of 4 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 4 of 4
Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)
Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 1 of 19 EXHIBIT C - EUT INTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 2 of 19 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 3 of 19 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 4 of 19 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 5 of 19 BT/Wi-Fi ANT 2G/3G/4G ANT Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 6 of 19 DIV ANT Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 7 of 19 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 8 of 19 NFC ANT Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 9 of 19 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 10 of 19 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 11 of 19 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 12 of 19 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 13 of 19 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 14 of 19 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 15 of 19 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 16 of 19 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 17 of 19 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 18 of 19 Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2401S34482E-RF Page 19 of 19
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E TR-EM-RF030 Page 13 of 91 Version 3.0 FCC §1.1307 (B) & §2.1091- MPE-BASED EXEMPTION Applicable Standard According to subpart 2.1091 systems operating under the provisions of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in excess of the communication guidelines. According to KDB 447498 D04 Interim General RF Exposure Guidance MPE-Based Exemption: General frequency and separation-distance dependent MPE-based effective radiated power(ERP) thresholds are in Table B.1 [Table 1 of § 1.1307(b)(1)(i)(C)] to support an exemptionfrom further evaluation from 300 kHz through 100 GHz. For multiple RF sources: Multiple RF sources are exempt if: in the case of fixed RF sources operating in the same time-averaging period, or of multiple mobile or portable RF sources within a device operating in the same time averaging period, if the sum of the fractional contributions to the applicable thresholds is less than or equal to 1 as indicated in the following equation: Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E TR-EM-RF030 Page 14 of 91 Version 3.0 Result Mode Frequency (MHz) Tune up conducted power # Antenna Gain # ERP Evaluation Distance (cm) ERP Limit (mW) (dBm) (dBi)(dBd)(dBm)(mW) BT 2402-2480 7.5 2.48 0.33 7.83 6.07 25 1200 BLE 2402-2480 -1.5 2.48 0.33 -1.17 0.76 25 1200 2.4G Wi-Fi 2412-2462 25.5 2.48 0.33 25.83 382.82 25 1200 5.2G Wi-Fi 5180-5240 11.0 2.49 0.34 11.34 13.61 25 1200 GSM850* 824-849 25.49 0.69 -1.46 24.03 252.93 25 659 PCS1900* 1850-1910 22.49 1.31 -0.84 21.65 146.22 25 1200 WCDMA B2 1850-1910 22.5 1.31 -0.84 21.66 146.55 25 1200 WCDMA B5 824-849 22.0 0.69 -1.46 20.54 113.24 25 659 LTE B2 1850-1910 22.5 1.31 -0.84 21.66 146.55 25 1200 LTE B4 1710-1755 21.5 0.07 -2.08 19.42 87.50 25 1200 LTE B7 2500-2570 21.5 4.54 2.39 23.89 244.91 25 1200 LTE B38 2570-2620 21.5 4.07 1.92 23.42 219.79 25 1200 Note: 1. The tune up conducted power and antenna gain was declared by the applicant. 2. The BT, 2.4G Wi-Fi and 5G Wi-Fi cannot transmit at same time. 3. 0dBd=2.15dBi Note*: It was the time average power according to the duty cycle. Mode Tune-up Peak Output Power (dBm) Tune-up Average Output Power (dBm) Low Middle High Low Middle High GPRS850 1 slot 33.0 33.0 33.0 23.97 23.97 23.97 2 slots 31.5 31.5 31.5 25.48 25.48 25.48 3 slots 29.5 29.5 29.5 25.24 25.24 25.24 4 slots 28.5 28.5 28.5 25.49 25.49 25.49 GPRS1900 1 slot 29.5 29.5 29.5 20.47 20.47 20.47 2 slots 28.5 28.5 28.5 22.48 22.48 22.48 3 slots 26.5 26.5 26.5 22.24 22.24 22.24 4 slots 25.5 25.5 25.5 22.49 22.49 22.49 Note: the duty cycle for 1 slot is 1/8, 2 slots is 1/4, 3 slots is 3/8, 4 slots is 1/2 The average power=Peak power+ duty cycle factor Duty cycle factor=10*log (duty cycle) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E TR-EM-RF030 Page 15 of 91 Version 3.0 NFC: Mode Frequency (MHz) Maximum E-Field (dBuV/m@3m) Maximum EIRP (dBm) ERP Evaluation Distance (cm) ERP Limit (mW) (dBm)(mW) NFC 13.56 71.68 -23.52 -25.67 0.0027 25 1173 Note: EIRP = E-Field – 95.2 @3m, ERP = EIRP-2.15 Simultaneous transmitting consideration (worst case): The ratio= ERP 2.4G Wi-Fi /limit +ERP GSM850 /limit+ ERP NFC /limit = 382.82/1200+ 252.93/659+ 0.0027/1173 =0.703<1.0 So simultaneous exposure is compliant. To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 25cm from nearby persons. Result: Compliant.
Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF030 Page 1 of 91 Version 3.0 TEST REPORT Applicant Name: Telepower Communication Co., Ltd. Address: 5 Bld, Zone A, Hantian Technology Town No.17 ShenHai RD, Nanhai District Foshan China Report Number: 2401S34482E-RF-00E FCC ID: 2AJ2B-T10 Test Standard (s) FCC PART 27; FCC PART 22H; FCC PART 24E Sample Description Product Type: Ticket Validator Model No.: T10 Multiple Model(s) No.: N/A Trade Mark: Telpo Date Received: 2024/04/26 Issue Date: 2024/08/09 Test Result: Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By: Approved By: Gala Liu Nancy Wang RF Engineer RF Supervisor Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E TR-EM-RF030 Page 2 of 91 Version 3.0 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 4 GENERAL INFORMATION ....................................................................................................................................... 5 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 5 OBJECTIVE ................................................................................................................................................................... 6 TEST METHODOLOGY .................................................................................................................................................. 6 MEASUREMENT UNCERTAINTY .................................................................................................................................... 6 TEST FACILITY ............................................................................................................................................................. 7 SYSTEM TEST CONFIGURATION .......................................................................................................................... 8 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 8 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 8 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 9 SUPPORT CABLE DESCRIPTION .................................................................................................................................... 9 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 9 SUMMARY OF TEST RESULTS ............................................................................................................................. 11 TEST EQUIPMENT LIST ......................................................................................................................................... 12 FCC §1.1307 (B) & §2.1091- MPE-BASED EXEMPTION ..................................................................................... 13 APPLICABLE STANDARD ............................................................................................................................................ 13 RESULT ...................................................................................................................................................................... 14 FCC§2.1047 - MODULATION CHARACTERISTIC ............................................................................................. 16 FCC § 2.1046, § 22.913 (A) (D) & § 24.232 (C) (D); §27.50 (D) (H) - RF OUTPUT POWER .............................. 17 APPLICABLE STANDARD ............................................................................................................................................ 17 TEST PROCEDURE ...................................................................................................................................................... 17 TEST DATA ................................................................................................................................................................ 17 FCC §2.1049, §22.917, §22.905 & §24.238&§27.53 - OCCUPIED BANDWIDTH ................................................ 30 APPLICABLE STANDARD ............................................................................................................................................ 30 TEST PROCEDURE ...................................................................................................................................................... 30 TEST DATA ............................................…
Text truncated - open the document above for the full version.
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 1 of 20 Please refer to following plots: Band 2_1.4 MHz_Middle_QPSK_RB6#0 Band 2_1.4 MHz_Middle_16QAM_RB6#0 Att 25 dB * A Ref 30 dBm Offset 10.5 dB LVL Center 1.88 GHzSpan 3 MHz300 kHz/ 1 PK MAXH * * 3DB RBW 30 kHz VBW 100 kHz SWT 15 ms -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -11.11 dBm 1.879352000 GHz 1 Delta 1 [T1 ] 0.33 dB 1.320000000 MHz OBW 1.104000000 MHz T1 Temp 1 [T1 OBW] 8.30 dBm 1.879454000 GHz T2 Temp 2 [T1 OBW] 8.46 dBm 1.880558000 GHz D1 15.2 dBm D2 -10.8 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 16:28:59 Att 25 dB * A Ref 30 dBm Offset 10.5 dB LVL Center 1.88 GHzSpan 3 MHz300 kHz/ 1 PK MAXH * * 3DB RBW 30 kHz VBW 100 kHz SWT 15 ms -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -11.17 dBm 1.879358000 GHz 1 Delta 1 [T1 ] -1.66 dB 1.296000000 MHz OBW 1.104000000 MHz T1 Temp 1 [T1 OBW] 7.36 dBm 1.879454000 GHz T2 Temp 2 [T1 OBW] 7.38 dBm 1.880558000 GHz D1 14.5 dBm D2 -11.5 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 16:29:13 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 2 of 20 Band 2_3 MHz_Middle_QPSK_RB15#0 Band 2_3 MHz_Middle_16QAM_RB15#0 Att 25 dB * A Ref 30 dBm Offset 10.5 dB LVL Center 1.88 GHzSpan 6 MHz600 kHz/ 1 PK MAXH * * 3DB RBW 30 kHz VBW 100 kHz SWT 30 ms -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -13.17 dBm 1.878536000 GHz 1 Delta 1 [T1 ] -0.31 dB 2.940000000 MHz OBW 2.700000000 MHz T1 Temp 1 [T1 OBW] 7.34 dBm 1.878656000 GHz T2 Temp 2 [T1 OBW] 10.09 dBm 1.881356000 GHz D1 12.92 dBm D2 -13.08 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 16:31:48 Att 25 dB * A Ref 30 dBm Offset 10.5 dB LVL Center 1.88 GHzSpan 6 MHz600 kHz/ 1 PK MAXH * * 3DB RBW 30 kHz VBW 100 kHz SWT 30 ms -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -13.59 dBm 1.878536000 GHz 1 Delta 1 [T1 ] -0.73 dB 2.952000000 MHz OBW 2.700000000 MHz T1 Temp 1 [T1 OBW] 7.30 dBm 1.878656000 GHz T2 Temp 2 [T1 OBW] 6.55 dBm 1.881356000 GHz D1 11.78 dBm D2 -14.22 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 16:32:01 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 3 of 20 Band 2_5 MHz_Middle_QPSK_RB25#0 Band 2_5 MHz_Middle_16QAM_RB25#0 Att 25 dB * A Ref 30 dBm Offset 10.5 dB LVL Center 1.88 GHzSpan 10 MHz1 MHz/ 1 PK MAXH * * 3DB RBW 100 kHz VBW 300 kHz SWT 5 ms -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -11.28 dBm 1.877500000 GHz 1 Delta 1 [T1 ] -1.15 dB 5.020000000 MHz OBW 4.520000000 MHz T1 Temp 1 [T1 OBW] 9.48 dBm 1.877740000 GHz T2 Temp 2 [T1 OBW] 10.28 dBm 1.882260000 GHz D1 15.01 dBm D2 -10.99 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 16:35:02 Att 25 dB * A Ref 30 dBm Offset 10.5 dB LVL Center 1.88 GHzSpan 10 MHz1 MHz/ 1 PK MAXH * * 3DB RBW 100 kHz VBW 300 kHz SWT 5 ms -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -12.95 dBm 1.877500000 GHz 1 Delta 1 [T1 ] 0.85 dB 5.040000000 MHz OBW 4.520000000 MHz T1 Temp 1 [T1 OBW] 7.48 dBm 1.877740000 GHz T2 Temp 2 [T1 OBW] 9.99 dBm 1.882260000 GHz D1 13.83 dBm D2 -12.17 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 16:35:15 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 4 of 20 Band 2_10 MHz_Middle_QPSK_RB50#0 Band 2_10 MHz_Middle_16QAM_RB50#0 Att 25 dB * A Ref 30 dBm Offset 10.5 dB LVL Center 1.88 GHzSpan 20 MHz2 MHz/ 1 PK MAXH * * 3DB RBW 100 kHz VBW 300 kHz SWT 10 ms -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -12.99 dBm 1.875200000 GHz 1 Delta 1 [T1 ] 0.64 dB 9.680000000 MHz OBW 8.920000000 MHz T1 Temp 1 [T1 OBW] 8.83 dBm 1.875560000 GHz T2 Temp 2 [T1 OBW] 9.17 dBm 1.884480000 GHz D1 12.84 dBm D2 -13.16 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 16:37:44 Att 25 dB * A Ref 30 dBm Offset 10.5 dB LVL Center 1.88 GHzSpan 20 MHz2 MHz/ 1 PK MAXH * * 3DB RBW 100 kHz VBW 300 kHz SWT 10 ms -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -14.31 dBm 1.875200000 GHz 1 Delta 1 [T1 ] 1.21 dB 9.640000000 MHz OBW 8.920000000 MHz T1 Temp 1 [T1 OBW] 6.91 dBm 1.875560000 GHz T2 Temp 2 [T1 OBW] 8.36 dBm 1.884480000 GHz D1 11.38 dBm D2 -14.62 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 16:37:58 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 5 of 20 Band 2_15 MHz_Middle_QPSK_RB75#0 Band 2_15 MHz_Middle_16QAM_RB75#0 Att 25 dB * A Ref 30 dBm Offset 10.5 dB LVL Center 1.88 GHzSpan 30 MHz3 MHz/ 1 PK MAXH * * 3DB RBW 300 kHz VBW 1 MHz SWT 2.5 ms -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -9.52 dBm 1.872740000 GHz 1 Delta 1 [T1 ] -1.46 dB 14.700000000 MHz OBW 13.440000000 MHz T1 Temp 1 [T1 OBW] 10.37 dBm 1.873340000 GHz T2 Temp 2 [T1 OBW] 10.05 dBm 1.886780000 GHz D1 15.9 dBm D2 -10.1 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 16:40:11 Att 25 dB * A Ref 30 dBm Offset 10.5 dB LVL Center 1.88 GHzSpan 30 MHz3 MHz/ 1 PK MAXH * * 3DB RBW 300 kHz VBW 1 MHz SWT 2.5 ms -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -9.13 dBm 1.872680000 GHz 1 Delta 1 [T1 ] -0.36 dB 14.760000000 MHz OBW 13.440000000 MHz T1 Temp 1 [T1 OBW] 9.51 dBm 1.873340000 GHz T2 Temp 2 [T1 OBW] 10.15 dBm 1.886780000 GHz D1 15.27 dBm D2 -10.73 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 16:40:24 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 6 of 20 Band 2_20 MHz_Middle_QPSK_RB100#0 Band 2_20 MHz_Middle_16QAM_RB100#0 Att 25 dB * A Ref 30 dBm Offset 10.5 dB LVL Center 1.88 GHzSpan 40 MHz4 MHz/ 1 PK MAXH * * 3DB RBW 300 kHz VBW 1 MHz SWT 2.5 ms -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -8.91 dBm 1.870480000 GHz 1 Delta 1 [T1 ] -0.75 dB 19.280000000 MHz OBW 17.920000000 MHz T1 Temp 1 [T1 OBW] 9.88 dBm 1.871120000 GHz T2 Temp 2 [T1 OBW] 10.47 dBm 1.889040000 GHz D1 15.79 dBm D2 -10.21 dBm ProjectNo.:2401S34482E-RF Tester:Allen Ba…
Text truncated - open the document above for the full version.
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 1 of 60 Please refer to following plots: Band 2_1.4 MHz_Low_QPSK_RB1#0_1(30MHz-1GHz) Band 2_1.4 MHz_Low_QPSK_RB1#0_2(1GHz-20GHz) A * 3DB RBW 100 kHz SWT 100 ms * VBW 300 kHz Att 30 dB * Offset 10.5 dB LVL Ref 10 dBm Start 30 MHzStop 1 GHz97 MHz/ 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -50.91 dBm 763.320000000 MHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:17:02 A * 3DB RBW 1 MHz SWT 110 ms * VBW 3 MHz Att 25 dB * Offset 10.5 dB LVL Ref 30 dBm Start 1 GHzStop 20 GHz1.9 GHz/ 1 PK MAXH -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -39.49 dBm 3.470000000 GHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:17:12 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 2 of 60 Band 2_1.4 MHz_Middle_QPSK_RB1#0_1(30MHz-1GHz) Band 2_1.4 MHz_Middle_QPSK_RB1#0_2(1GHz-20GHz) A * 3DB RBW 100 kHz SWT 100 ms * VBW 300 kHz Att 30 dB * Offset 10.5 dB LVL Ref 10 dBm Start 30 MHzStop 1 GHz97 MHz/ 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -50.29 dBm 299.660000000 MHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:17:24 A * 3DB RBW 1 MHz SWT 110 ms * VBW 3 MHz Att 25 dB * Offset 10.5 dB LVL Ref 30 dBm Start 1 GHzStop 20 GHz1.9 GHz/ 1 PK MAXH -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -39.97 dBm 3.318000000 GHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:17:34 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 3 of 60 Band 2_1.4 MHz_High_QPSK_RB1#0_1(30MHz-1GHz) Band 2_1.4 MHz_High_QPSK_RB1#0_2(1GHz-20GHz) A * 3DB RBW 100 kHz SWT 100 ms * VBW 300 kHz Att 30 dB * Offset 10.5 dB LVL Ref 10 dBm Start 30 MHzStop 1 GHz97 MHz/ 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -51.05 dBm 800.180000000 MHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:17:50 A * 3DB RBW 1 MHz SWT 110 ms * VBW 3 MHz Att 25 dB * Offset 10.5 dB LVL Ref 30 dBm Start 1 GHzStop 20 GHz1.9 GHz/ 1 PK MAXH -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -39.99 dBm 3.394000000 GHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:18:00 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 4 of 60 Band 2_3 MHz_Low_QPSK_RB1#0_1(30MHz-1GHz) Band 2_3 MHz_Low_QPSK_RB1#0_2(1GHz-20GHz) A * 3DB RBW 100 kHz SWT 100 ms * VBW 300 kHz Att 30 dB * Offset 10.5 dB LVL Ref 10 dBm Start 30 MHzStop 1 GHz97 MHz/ 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -50.84 dBm 140.580000000 MHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:20:28 A * 3DB RBW 1 MHz SWT 110 ms * VBW 3 MHz Att 25 dB * Offset 10.5 dB LVL Ref 30 dBm Start 1 GHzStop 20 GHz1.9 GHz/ 1 PK MAXH -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -40.08 dBm 2.292000000 GHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:20:41 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 5 of 60 Band 2_3 MHz_Middle_QPSK_RB1#0_1(30MHz-1GHz) Band 2_3 MHz_Middle_QPSK_RB1#0_2(1GHz-20GHz) A * 3DB RBW 100 kHz SWT 100 ms * VBW 300 kHz Att 30 dB * Offset 10.5 dB LVL Ref 10 dBm Start 30 MHzStop 1 GHz97 MHz/ 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -50.40 dBm 472.320000000 MHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:20:54 A * 3DB RBW 1 MHz SWT 110 ms * VBW 3 MHz Att 25 dB * Offset 10.5 dB LVL Ref 30 dBm Start 1 GHzStop 20 GHz1.9 GHz/ 1 PK MAXH -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -39.02 dBm 3.470000000 GHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:21:04 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 6 of 60 Band 2_3 MHz_High_QPSK_RB1#0_1(30MHz-1GHz) Band 2_3 MHz_High_QPSK_RB1#0_2(1GHz-20GHz) A * 3DB RBW 100 kHz SWT 100 ms * VBW 300 kHz Att 30 dB * Offset 10.5 dB LVL Ref 10 dBm Start 30 MHzStop 1 GHz97 MHz/ 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -50.13 dBm 255.040000000 MHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:21:19 A * 3DB RBW 1 MHz SWT 110 ms * VBW 3 MHz Att 25 dB * Offset 10.5 dB LVL Ref 30 dBm Start 1 GHzStop 20 GHz1.9 GHz/ 1 PK MAXH -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -39.88 dBm 3.318000000 GHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:21:30 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 7 of 60 Band 2_5 MHz_Low_QPSK_RB1#0_1(30MHz-1GHz) Band 2_5 MHz_Low_QPSK_RB1#0_2(1GHz-20GHz) A * 3DB RBW 100 kHz SWT 100 ms * VBW 300 kHz Att 30 dB * Offset 10.5 dB LVL Ref 10 dBm Start 30 MHzStop 1 GHz97 MHz/ 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -50.06 dBm 937.920000000 MHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:23:08 A * 3DB RBW 1 MHz SWT 110 ms * VBW 3 MHz Att 25 dB * Offset 10.5 dB LVL Ref 30 dBm Start 1 GHzStop 20 GHz1.9 GHz/ 1 PK MAXH -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -40.28 dBm 19.050000000 GHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:23:19 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 8 of 60 Band 2_5 MHz_Middle_QPSK_RB1#0_1(30MHz-1GHz) Band 2_5 MHz_Middle_QPSK_RB1#0_2(1GHz-20GHz) A * 3DB RBW 100 kHz SWT 100 ms * VBW 300 kHz Att 30 dB * Offset 10.5 dB LVL Ref 10 dBm Start 30 MHzStop 1 GHz97 MHz/ 1 PK MAXH -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 1 Marker 1 [T1 ] -50.48 dBm 80.440000000 MHz D1 -13 dBm ProjectNo.:2401S34482E-RF Tester:Allen Bai Date: 19.MAY.2024 17:23:31 A * 3DB RBW 1 MHz SWT 110 ms * VBW 3 MHz Att 25 dB * Offset 10.5 dB LVL Ref 30 dBm Start 1 GHzStop 20 GHz1.9 GHz/ 1 PK MAXH -70 -60 -…
Text truncated - open the document above for the full version.
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2401S34482E-RF-00E Page 1 of 80 Please refer to following plots: For Band Edge 1RB: Band2_1.4 MHz_High_16QAM_RB1#Max Band2_1.4 MHz_High_QPSK_RB1#Max A Offset 10.5 dB LVL Att 30 dB ** Ref 30 dBm 3DB RBW 30 kHz * Center 1.91 GHzSpan 3 …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 17 | 27 | 2.58 GHz - 2.61 GHz | 193.00 mW | 17M9W7D | 2.5 ppm |

Cash Register
Equipment Class
NII - Unlicensed National Information Infrastructure TX
POS Terminal
Equipment Class
DTS - Digital Transmission System
POS Terminal
Equipment Class
DTS - Digital Transmission System
Self-Service Kiosk
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Pos terminal
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter