FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Smart Care Technology Limited/
  3. 2AKUO-IML

2AKUO-IMLSmart watch

Shenzhen Smart Care Technology Limited
Smart watch - FCC ID 2AKUO-IML - Shenzhen Smart Care Technology Limited
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 25, 2021
Application Purpose
Original Equipment
Date of Application
May 25, 2021
Equipment Note
Smart watch
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Smart Care Technology Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

IML 3. Blood pressure Wear the watch in a right way, and open the menu--blood pressure, measure it manual. 4. Alarm clock Setting the alarms in APP and sync to watch, maximum 8 alarms. 5. Music control Control the music player of mobile phone to play the music,as well as song switching and volume adjustment. 6. Stopwatch Electronic timer that can record one time or record multiple times. 7. Countdown The same way to calculate the remaining time. 8. Remote capture This feature can remote control the mobile camera to take pictures,please click - smart camera and turn on the camera. 3. After install the App, register and log in account according to a series of instructions. 4. Continue following the onscreen instructions to connect or pair your smart watch to your mobile device. Pairing make sure that the watch and mobile device can communicate with each other(sync their data). Open APP>Device> Add device>Choose IML. 5. Select the Bluetooth name IML with the strongest signal from the list. Then the watch will show paring notifi cation, click to confi rm pairing. Then you will see the Bluetooth icon on the right top on the watch or in quick setting page (slide down page) turns to Blue, then Bluetooth is connected. (You need to use Android 5.0+ or iOS 11.0+ and above and the watch can only be paired with one mobile phone. To pair other mobile phones, please unbind the current one before pairing.) Quick Fit Strap IML contains two parts (watch body and wristband), you can purchase seperately strap and switch as your preference. Charging instructions Charging Turn the watch over, align and attach the charging pins to the magnets gold prongs. You will see the charging icon on the watch screen after 5s. Charging fully may take 2 hours. you will see the battery icon is full if the watch have been fully charged. Please clean the charge interface before charging for fear that the remaining sweat erode gold metal contact or other risks. Functions 1.Sports The IML watch supports up to 11 sports modes including: Running, Walking, Cycling, Climbing, Treadmills, Spinning, Yoga, Swimming, Basketball, Football, Badminton. 2. Heart rate Wearing IML correctly, not too tight or loose, make sure no green light leak, there is two measuring ways: Turn on the heart rate icon on the watch and measuring heart rate by manual. Set automatic monitoring time interval in app (monitoring once every 15/ 30/ 60/ 120 minutes). 9. Find phone Under Bluetooth connection, cilck "Find phone" on the watch, the phone ringing, click pause to stop. 10. Settings Set the watch's general functions, brightness, language, power off , return to factory, about. 11. Sports records Sports mode records was done, maximum 10 records, update automatically. 12. Other functions 1) Change watch face (Long press the screen or power button, swipe to choose, click to confi rm) 2) Pedometer (Steps, Distance, Calories, Heart rate) 4) Weather (Weather forecast) 5) Health care (Female physiological function) 6) Slide down quick setting menu Troubleshooting Heart-rate signal missing The IML smart watch keeps paying attention to your heart rate data during your exercise and your daily life. Sometime the watch may not get a suitable heart rate signal. At this time, the missing heart rate data will appear at the dotted line. If you can't get the heart rate signal, fi rst you should confi rm that you wear the watch correctly, adjust it to avoid being too high or too low, neither too tight or too loose on your wrist. After adjustment, turn on real-time heart rate monitoring to get the data. If there is still no heart rate data, check if the heart rate monitoring function is turned on at SMART-TIME PRO App. Other problems If your mobile cannot pair the watch, click Settings - Bluetooth in your mobile and check if there is signal of IML. If yes, it means there is no problem with the Bluetooth signal. Please check if the watch is paired with other phones, please unbind it. IOS device users should click Setting - Bluetooth - ignore this device and then pair it. Exemption Clause 1. The Heart rate, Blood pressuredata output by IML are not intended to be a medical or diagnostic basis. 2. Self-diagnosis and self-treatment are dangerous. Only qualifi ed physicians are allowed to diagnose and treat high blood pressure or any other heart diseases. Please contact your physician for more professional diagnostic opinions. 3. The data and information of heart rate and blood pressure provided by IML may not be completely accurate and may exceed the tolerance as per the specifi cation stated in the document due to diuerent factors, such as interference with signal from external sources, incorrect wearing position and changes in weather conditions or user's body condition. 4. DO NOT adjust any of your medication or therapeutic schedule based on the results output by IML. Please follow the doctor's instructions before taking any treatment or medication. We disclaim all liability arising from such inaccuracy and assu mes no responsibility for the consequences of use of such data and information. Warranty Clause Our company always pursues the service concept of "creating value for customers" We offer 1year warranty period for IML smart watch. If there is any damage or malfunction during normal use, the warranty service will be provided to the customer for free after confi rmation by our technician. The following conditions are not covered by the warranty: A. Accident or human damage B. Testing, repairing or disassembling without authorization C. Contamination due to human reasons D. Damage caused by connection with equipment which is not compatible E. Natural aging F. Damage caused by force majeure Getting Started Welcome to use our IML, this is a smart watch which can help you reach your sport goals. The package includes: · IML smart watch · User Manual · Charging cable Setting up your IML First download & install the app SMART-TIME PRO, and create an account to make sure the watch…

Text truncated - open the document above for the full version.

Cover Letter(s)

Co m Ad d She Pr o Mo d R5, Pr o We act We an d issu our Sig Na m Title Com mpany: Sh dress: 3/F, enzhen, Ch oduct Name del Numbe R6, R7, R8 oduct Desc authorize M on our beha declare tha d certificatio ues concern behalf shal nature: me: e: mpany: S enzhen Sm Block 3, Y hina e: Smart wa er(s): IML, F 8, R9, R10, ription: S m MiCOM Lab alf on all ma at MiCOM L n of equipm ning the app ll have the s Helen Hu a Sales Man Shenzhen Shenzhen S Agen mart Care T onghe Roa atch F1, F2, F2C R11, R12, mart watch bs Inc., 575 atters conce Labs Inc. is ment to the r proval applic same effect ang nager n Smart Ca Smart Care nt Auth Technology ad, Heping C, F3, F3R, G2, G3, G 4 Boulder Co erning the c allowed to f regulatory a cation. Any t as acts of are Techno Technolog horizat y Limited communi t F3C, F3D, 4, G5, ITIME ourt, Pleasa certification forward all i agencies as and all acts our own. logy Limite gy Limited tion ty, Fuhai st F5, F6, F7, E, BT-982 anton, Califo of above na information s required a s carried ou Date: ed treet, Baoa F8, F9, F1 ornia 94566 amed equip related to t nd to discu ut by MiCOM May. 25, 2 an District, 0, R3, R4, 6, USA, to pment. the approva ss any M Labs on 2021 al

Cover Letter(s)

Office o Federa 7435 O Columb USA Subjec t FCC ID To Wh o Pursua are req u docume These d propriet might b It is ou r corresp docume authoriz Sincer e Signat u Name: Title: S a of Engineeri l Communic Oakland Mills bia, MD 210 t; Request f D: 2AKUO-IM om It May C nt to the pro uesting the ents from pu documents tary informa be harmful to Schema Block D Parts Lis Operatio r understand pondence du ents and thi zation is iss ely, ure: Helen Hua n ales Manag She ing Techno cations Com s Road 046 for Confiden ML Concern, ovisions of t Commissio ublic disclos contain det ation in ope o our comp atic Diagram iagram st onal Descri ding that all uring the ce s informatio sued. ng ger enzhen Sma logy mmission ntiality the Commis on to withho sure indefin tailed syste ration of th e any and wo m ption l measurem ertification re on will be av art Care Te ssion’s rule old the follow nitely. m and equi e equipmen ould give co ment test rep eview proce vailable for echnology s Title 47 S wing attach pment desc nt. The publ ompetitors a ports, FCC ess cannot public revi e Limited Sections §0. hment(s) as criptions an ic disclosu r an unfair ad ID label for be granted ew once the Date: May. 457 and §0 confidentia d are consi re of these d vantage in mat and as confide n e grant of eq 25, 2021 0.459, we al dered as documents the market . ntial quipment .

Cover Letter(s)

Model Difference Declaration To Whom It May Concern, We, Shenzhen Smart Care Technology Limited(Smart watch) Trademark:SMA; Model Number:IML, F1, F2, F2C, F3, F3R, F3C, F3D, F5, F6, F7, F8, F9, F10, R3, R4, R5, R6, R7, R8, R9, R10, R11, R12, G2, G3, G4, G5, ITIME, BT-982;All model’s the function, s oftware and electric circuit are the same, only with a product color, appearance and model named different. Test sample model: IML. Please contact me if you have any question. Name: Helen Huang Date: May. 25, 2021 Title: Sales Manager Signature of applicant:

External Photos

Annex A External Photos Report No.: HK2105111452‐E Page 1 of 4 Report No.: HK2105111452‐E Page 2 of 4 Report No.: HK2105111452‐E Page 3 of 4 Report No.: HK2105111452‐E Page 4 of 4

ID Label/Location Info

FCC ID LABEL: Ca. 5mm x 10mm Include in manual: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Label Location FCC ID: 2AKUO-IML

Internal Photos

Annex B Internal Photos Report No.: HK2105111452‐E Page 1 of 3 Report No.: HK2105111452‐E Page 2 of 3 Antenna Report No.: HK2105111452‐E Page 3 of 3

RF Exposure Info

FCC RF Exposure EUT Description: Smart watch Model No.: IML, F1, F2, F2C, F3, F3R, F3C, F3D, F5, F6, F7, F8, F9, F10, R3, R4, R5, R6, R7, R8, R9, R10, R11, R12, G2, G3, G4, G5, ITIME, BT‐982 FCC ID: 2AKUO‐IML 1. Limits According to KDB 447498 D01 General RF Exposure Guidance v06 The 1‐g and 10‐g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤50 mm are determined by: [(max power of channel, including tune‐up tolerance, mW)/(min. test separation distance, mm)]·[√ f(GHz)]≤3.0 for 1‐g SAR and ≤ 7.5 for 10‐g extremity SAR, Where: Result=P/D*√F F= the RF channel transmit frequency in GHz P=Maximum turn‐up power in mw D=Min. test separation distance in mm 2. Test Result of RF Exposure Evaluation Frequency (MHz) Output power (dBm) Tune Up Power (dBm) Max Tune Up power dBm/mW Min test separati on distance mm Result Limit (mW/cm 2 ) SAR Test Exclusion 2402 4.425 4±1 5/3.162 5 0.98 3.0 Pass Note: PK Output power= conducted power. Conducted power see the test report HK2105111452‐E, antenna gain=0dBi Per KDB 447498 D01, when the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine RF Exposure test exclusion. The test exclusion threshold is 0.98 which is<= 3, RF Exposure testing is not required. Note: Exclusion Thresholds Results=[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f (GHz)] f(GHz) is the RF channel transmit frequency in GHz Distance=5mm

Test Report

Page 1 of 45 Report No.: HK2105111452-E TEST REPORT FCC PART 15 SUBPART C 15.247 Test report On Behalf of Shenzhen Smart Care Technology Limited For Smart watch Model No.: IML, F1, F2, F2C, F3, F3R, F3C, F3D, F5, F6, F7, F8, F9, F10, R3, R4, R5, R6, R7, R8, R9, R10, R11, R12, G2, G3, G4, G5, ITIME, BT-982 FCC ID: 2AKUO-IML Prepared for : Shenzhen Smart Care Technology Limited 3/F, Block 3, Yonghe Road, Heping community, Fuhai street, Baoan District, Shenzhen, China Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: May. 07, 2021 ~ May. 14, 2021 Date of Report: May. 14, 2021 Report Number: HK2105111452-E Page 2 of 45 Report No.: HK2105111452-E TEST RESULT CERTIFICATION Applicant’s name .............. Shenzhen Smart Care Technology Limited Address .............................. 3/F, Block 3, Yonghe Road, Heping community, Fuhai street, Baoan District, Shenzhen, China Manufacture's Name ........ Shenzhen Smart Care Technology Limited Address .............................. 3/F, Block 3, Yonghe Road, Heping community, Fuhai street, Baoan District, Shenzhen, China Product description Trade Mark: SMA Product name ......................Smart watch Model and/or type reference .......................... IML, F1, F2, F2C, F3, F3R, F3C, F3D, F5, F6, F7, F8, F9, F10, R3, R4, R5, R6, R7, R8, R9, R10, R11, R12, G2, G3, G4, G5, ITIME, BT-982 Standards .......................... 47 CFR FCC Part 15 Subpart C 15.247 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test............................................... : Date (s) of performance of tests ............... : May. 07, 2021 ~ May. 14, 2021 Date of Issue ............................................. : May. 14, 2021 Test Result ................................................. : Pass Prepared by: Project Engineer Reviewed by: Project Supervisor Approved by: Technical Director Page 3 of 45 Report No.: HK2105111452-E Contents Page CONTENTS .............................................................................................................................................................. 3 1 TEST SUMMARY ............................................................................................................................................ 6 1.1 TEST DESCRIPTION ...................................................................................................................................... 6 1.2 MEASUREMENT UNCERTAINTY ...................................................................................................................... 7 2 TEST FACILITY ............................................................................................................................................... 7 3 GENERAL INFORMATION ............................................................................................................................. 8 3.1 GENERAL DESCRIPTION OF EUT .................................................................................................................. 8 3.2 DESCRIPTION OF TEST CONDITIONS ............................................................................................................ 10 3.3 DESCRIPTION OF TEST SETUP ........................................................................................................... 10 4 EQUIPMENTS LIST FOR ALL TEST ITEMS ............................................................................................... 11 5 TEST RESULT .............................................................................................................................................. 13 5.1 ANTENNA REQUIREMENT ............................................................................................................................ 13 5.1.1 Standard requirement ...................................................................................................................... 13 5.1.2 EUT Antenna ................................................................................................................................... 13 5.2 CONDUCTION EMISSIONS MEASUREMENT ................................................................................................... 14 5.2.1 Applied procedures / Limit ............................................................................................................... 14 5.2.2 Test procedure ................................................................................................................................. 14 5.2.3 Test setup ........................................................................................................................................ 15 5.2.4 Test results ...................................................................................................................................... 16 5.3 RADIATED EMISSIONS MEASUREMENT ........................................................................................................ 18 5.3.1 Applied procedures / Limit ............................................................................................................... 18 5.3.2 Test setup ........................................................................................................................................ 18 5.3.3 Test Result ....................................................................................................................................... 20 5.4 MAXIMUM OUTPUT POWER MEASUREMENT .........................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Model:IML Radiated Emission

Contact Information

Applicant

Helen Huang
[email protected]+86-755-23707058Fax: +86-755-25737350

Technical Contact

ShenZhen Smart Care Technology Limited
[email protected]

China

Test Firm

Shenzhen HUAK Testing Technology Co., Ltd.Jason Zhou
[email protected]+86-755-23029901

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.77 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.

Other Applications from Shenzhen Smart Care Technology Limited

2AKUO-FW5

Earbud

Aug 18, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AKUO-RN02

smart ring

Jun 08, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AKUO-GJ03A

Smart glasses

Jan 09, 2026

Equipment Class

DTS - Digital Transmission System