Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Festool GmbH ▪ Postfach 1163 ▪ 73236 Wendlingen Attestation Statements 2024-06-03 TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for FCC ID: 2AL2E-CTN2648 Festool GmbH the undersigned, hereby authorize Tooltechnic Systems to act as our designated U.S. agent for service of process, Festool GmbH accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Tooltechnic Systems accepts the responsibility to act as designated U.S. agent for service of process, provides an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Information: Company name: Festool GmbH Contact Name: Christian Bader Address: Wertstrasse 20, 73240 Wendlingen, Germany Telephone No: +49 7024 804-25479 Email: [email protected] FRN: 0026342238 U.S. Agent Information: Company Name: Tooltechnic Systems Address: 400 N Enterprise Blvd, Lebanon, IN 46052 Contact Name: Amanda Johnson Telephone No: 1-765-577-9329 Email: [email protected] FRN: 0026431700 Applicant Si gnature: Agent Signature: 2024-06-03 Applicant printed name: Agent printed name: Christian Bader Amanda Johnson
Festool GmbH ▪ Postfach 1163 ▪ 73236 Wendlingen 2024-05-23 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2AL2E-CTN2648 Festool GmbH (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Christian Bader Head of Functional Development 2024-05-23 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2AL2E-CTN2648 Festool GmbH (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Christian Bader Head of Functional Development
Festool GmbH ▪ Postfach 1163 ▪ 73236 Wendlingen 2024-05 -23 Eurofins MET Labs 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize SIQ Ljubljana, Mašera-Spasićeva ulica 10, 1000 Ljubljana, Slovenia to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Christian Bader Head of Functional Development
2024-05-23 Eurofins MET Labs 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR CT 26-48 AND FCC ID: 2AL2E- CTN2648 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the block diagrams, schematics, operation descriptions, parts list required to be submitted with this application be permanently withheld from public review. The above documents are company proprietary information that can never get into the possession of competition. Please contact me if there is any information you may need.
2024-05-23 Eurofins MET Labs 914 West Patapsco Avenue Baltimore, MD 21230 RE: Short Term Confidentiality Request For CT 26-48 AND FCC ID: 2AL2E- CTN2648 To Whom It May Concern: In accordance with sections 0.457 and 0.459 of CFR 47, Festool GmbH requests short- term Confidentiality of following sections of this application for a period of 45 days after grant is issued. Test setup photos External photos Internal photos User’s manual These documents contain detailed system and equipment descriptions and related information about the product, which Festool GmbH considers to be proprietary, confidential, and a custom design and otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, Festool GmbH feels that this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely,
The report shall not be reproduced except in full. SIQ Ljubljana, Mašera-Spasićeva ulica 10, SI-1000 Ljubljana, Slovenia T +386 1 4778 100, F +386 1 4778 444, [email protected], www.siq.si TN405E-03 Test report Number T251-0391/24 Project file: C20230681 Date: 2024-05-16 Pages: 5 Product: Vacuum cleaner Type reference: CT 26-48 Ratings: 120 V a.c.; 60 Hz, 1200 W Class: I Trademark: Applicant: Festool GmbH Wertstrasse 20, 73240 Wendlingen, Germany Manufacturer: Festool GmbH Wertstrasse 20, 73240 Wendlingen, Germany Place of manufacture: Festool GmbH Wertstrasse 20, 73240 Wendlingen, Germany Summary of testing Testing method: KDB 447498 D01 General RF Exposure Guidance v06 Testing location: SIQ Ljubljana Mašera-Spasićeva ulica 10, SI-1000 Ljubljana, Slovenia Remarks: Date of receipt of test items: 2024-02-20 Number of items tested: 1 Date of performance of tests: 2024-05-15 The test results presented in this report relate only to the items tested. The test items were tested in the condition as received. The product complies with the requirements of the testing methods. Tested by: Nik Vončina Approved by: Marjan Mak T251-0391/24 Page: 2 (5) CONTENTS page 1 GENERAL 3 1.1 EQUIPMENT UNDER TEST 3 2 ASSESSMENT PROCEDURE 4 3 MEASUREMENTS / CALCULATIONS 5 T251-0391/24 Page: 3 (5) 1 GENERAL History sheet Date Report No. Change Revision 2024-05-16 T251-0391/24 Initial Test Report issued. -- 1.1 Equipment under test Vacuum cleaner Type: CT 26-48 Environment: Uncontrolled / General Public Assessment distance: 10 mm FCC ID: 2AL2E-CTN2648 Reviewed test report T251-0214/24 from SIQ Ljubljana. T251-0391/24 Page: 4 (5) 2 ASSESSMENT PROCEDURE KDB 447498 D01 General RF Exposure Guidance v06 Clause 4.3.1. Standalone SAR test exclusion considerations SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions. For frequencies between 100 MHz and 6 GHz, the following may be considered for SAR test exclusion: a) For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, 30 where • f(GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation31 • The result is rounded to one decimal place for comparison • The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion. b) For 100 MHz to 6 GHz and test separation distances > 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following (also illustrated in Appendix B): 1) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50 mm)·(f(MHz)/150)]} mW, for 100 MHz to 1500 MHz 2) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance – 50 mm)·10]} mW, for > 1500 MHz and ≤ 6 GHz c) For frequencies below 100 MHz, the following may be considered for SAR test exclusion (also illustrated in Appendix C): 1) For test separation distances > 50 mm and < 200 mm, the power threshold at the corresponding test separation distance at 100 MHz in step b) is multiplied by [1 + log(100/f(MHz))] 2) For test separation distances ≤ 50 mm, the power threshold determined by the equation in c) 1) for 50 mm and 100 MHz is multiplied by ½ 3) SAR measurement procedures are not established below 100 MHz. T251-0391/24 Page: 5 (5) 3 MEASUREMENTS / CALCULATIONS Antenna type and gain: Integral antenna, 0 dBi KDB 447498 D01 General RF Exposure Guidance v06 Clause 4.3.1: Frequency (MHz) Maximum* power with tune-up (dBm) Maximum* power with tune-up (mW) SAR Test Exclusion Threshold (mW) 2402-2480 4.8 3.01995 19.05 * Gated power with Duty Cycle calculated in ** maximum tolerance provided from manufacturer is ±2dB. Conclusion: PASS; SAR Evaluation is not required due to SAR Test Exclusion Thresholds are met. There is no simultaneous transmission between any other transmitter.
The report shall not be reproduced except in full. SIQ Ljubljana, Mašera-Spasićeva ulica 10, SI-1000 Ljubljana, Slovenia T +386 1 4778 100, F +386 1 4778 444, [email protected], www.siq.si TN405E-04 Test report Number T251-0232/24 Project file: C20230329 Date: 2024-05-15 Pages: 9 Product: Vacuum cleaner Type reference: CT 26-48 Ratings: 120 V a.c.; 60 Hz, 1200 W Class: | Trademark: Applicant: Festool GmbH Wertstrasse 20, 73240 Wendlingen, Germany Manufacturer: Festool GmbH Wertstrasse 20, 73240 Wendlingen, Germany Place of manufacture: Festool GmbH Wertstrasse 20, 73240 Wendlingen, Germany Summary of testing Testing method: Antenna pattern measurements Testing location: SIQ Ljubljana Mašera-Spasićeva ulica 10, SI-1000 Ljubljana, Slovenia Remarks: Date of receipt of test items: 2024-02-20 Number of items tested: 1 Date of performance of tests: 2024-03-18 The test results presented in this report relate only to the items tested. The test items were tested in the condition as received. The product complies with the requirements of the testing methods. Tested by: Luka Cvajnar Approved by: Marjan Mak T251-0232/24 Page: 2 (9) CONTENTS page 1 GENERAL 3 1.1 EQUIPMENT UNDER TEST 3 1.2 ANTENNA PATTERN MEASUREMENT 4 1.3 TEST RESULTS BLE ANTENNA 5 1.4 MAXIMUM BLE ANTENNA GAIN 8 2 USED TEST EQUIPMENT 9 T251-0232/24 Page: 3 (9) 1 GENERAL History sheet Date Report No. Change Revision 2024-05-15 T251-0232/24 Initial Test Report issued. -- Environmental conditions: Ambient temperature: 15 C to 35 C Relative humidity: 30 % to 60 % Atmospheric pressure: 860 mbar to 1060 mbar 1.1 Equipment under test Vacuum cleaner Type: CT 26-48 Tested was antenna pattern of the sample below. Picture of test sample – BLE Antenna T251-0232/24 Page: 4 (9) Copy of marking plate The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks. 1.2 Antenna pattern measurement 1.2.1 Test procedure The radiation pattern for BLE antenna implemented to PCB reference design has been measured in an anechoic chamber with 3 meters test distance. Test results show radiation patterns for two planes, measured with vertical and horizontal polarization of measuring antenna. All measurements were performed at 2402, 2440 and 2480 MHz frequency. T251-0232/24 Page: 5 (9) 1.3 Test results BLE Antenna T251-0232/24 Page: 6 (9) T251-0232/24 Page: 7 (9) T251-0232/24 Page: 8 (9) 1.4 Maximum BLE antenna gain DUT Frequency (MHz) Maximum antenna gain (dBi) 2402.000000 -2.61 2440.000000 -1.34 2480.000000 -1.56 T251-0232/24 Page: 9 (9) 2 USED TEST EQUIPMENT Antenna pattern measurement Manufacturer Description Model No. Used Calibrated Calibrated until Comtest engineering, SAC2 (together with controlling equipment) SAC 3m X 2022-04-14 2025-04-14 Maturo, Turn table (2 m diameter) TT 2.0 SI X / / Maturo, Bore-sight antenna mast BAM-4.0-P X / / Maturo, positioning equipment NCD X / / Rohde & Schwarz, RFI receiver ESW 44 X 2023-03-09 2024-09-09 R&S, Ultra Broadband Antenna HL562E 2023-09-26 2026-09-26 R&S, Horn Antenna HF907 X 2023-08-22 2026-08-22
The report shall not be reproduced except in full. SIQ Ljubljana, Mašera-Spasićeva ulica 10, SI-1000 Ljubljana, Slovenia T +386 1 4778 100, F +386 1 4778 444, [email protected], www.siq.si TN405E-04 Test report Number T251-0214/24 Project file: C20230329 Date: 2024-07-22 Pages: 57 Product: Vacuum cleaner Type reference: CT 26-48 Ratings: 120 V a.c.; 60 Hz, 1200 W Class: I Trademark: Applicant: Festool GmbH Wertstrasse 20, 73240 Wendlingen, Germany Manufacturer: Festool GmbH Wertstrasse 20, 73240 Wendlingen, Germany Place of manufacture: Festool GmbH Wertstrasse 20, 73240 Wendlingen, Germany Summary of testing Testing method: 47 CFR Part 15, Subpart C (Clause 15.247) RSS-Gen (Issue 5), RSS-247 (Issue 3) in conjuction with ANSI C63.10-2013 Testing location: SIQ Ljubljana Mašera-Spasićeva ulica 10, SI-1000 Ljubljana, Slovenia Remarks: Date of receipt of test items: 2024-02-20 Number of items tested: 1 Date of performance of tests: 2024-02-26 – 2024-03-12 The test results presented in this report relate only to the items tested. The test items were tested in the condition as received. The product complies with the requirements of the testing methods. Tested by: Luka Cvajnar Approved by: Marjan Mak T251-0214/24 Page: 2 (57) CONTENTS Page 1 GENERAL 3 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST 3 1.2 DESCRIPTION OF THE TEST MODES 6 1.3 TEST EQUIPMENT USED FOR TESTING 7 1.4 TEST SETUP CONFIGURATIONS 8 2 TEST SUMMARY 10 2.1 APPLICATION OF DECISION RULE 10 3 TESTS RESULTS 11 3.1 47 CFR § 15.203 – ANTENNA REQUIREMENTS 11 3.2 47 CFR § 15.207 – AC LINE CONDUCTED EMISSION 12 3.3 47 CFR § 15.247(D) - SPURIOUS EMISSION - CONDUCTED 14 3.4 47 CFR § 15.205, § 15.209, § 15.247 (D) – SPURIOUS EMISSION - RADIATED 18 3.5 47 CFR § 15.247 (A) (2) – 6 DB EMISSION BANDWIDTH 35 3.6 47 CFR § 15.247 (B) (3) – MAXIMUM PEAK OUTPUT POWER 40 3.7 47 CFR § 15.247 (D) –100 KHZ BANDWIDTH OF FREQUENCY BAND EDGE 42 3.8 47 CFR § 15.247 (E) – POWER SPECTRAL DENSITY 49 4 ANNEX I – ADDITIONAL DATA 53 4.1 OCCUPIED BANDWIDTH (99% EMISSION BANDWIDTH) 54 T251-0214/24 Page: 3 (57) 1 GENERAL EUT passed the performed tests. History sheet Date Report No. Change Revision 2024-07-22 T251-0214/24 Initial Test Report issued. -- 1.1 Description of equipment under test Vacuum cleaner Type: CT 26-48 FCC ID: 2AL2E-CTN2648 IC: 22501-CTN2648 Adaptive / non-adaptive equipment non-adaptive equipment Modulation type Other than FHSS Operating mode Single antenna Operating temperature range -20 °C to +80 °C Maximum RF Output power 4 dBm Operating frequency 2402 MHz – 2480 MHz Number of channels 40 Antenna type and gain Integral antenna, -1.34 dBi Antenna Beamforming / Nominal channel bandwidth 1 MHz and 2 MHz Hardware version: 10680916 Firmware version: 10755580 T251-0214/24 Page: 4 (57) Examples of marking plates The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks. T251-0214/24 Page: 5 (57) T251-0214/24 Page: 6 (57) 1.2 Description of the test modes The equipment uses only one antenna at any moment. On all devices run test firmware Bluetooth Direct Test Mode and accompanied by a USB-UART converter interface. For testing purposes sample with integral antenna and modified sample with added SMA connector was provided. For testing nRFgo Studio software program from Nordic Semiconductor was used. 1.2.1 Tested Channels Channels Data rate Frequency [MHz] TX power Settings [dBm] Packet type Packet length (bytes) 0 (Lowest) 1 Mbps 2402 4 PRBS9 37 19 (Middle) 1 Mbps 2440 4 PRBS9 37 39 (Highest) 1 Mbps 2480 4 PRBS9 37 0 (Lowest) 2 Mbps 2402 4 PRBS9 37 19 (Middle) 2 Mbps 2440 4 PRBS9 37 39 (Highest) 2 Mbps 2480 4 PRBS9 37 Normal test condition: Ambient temperature: 15 C to 35 C Relative humidity: 30 % to 60 % Atmospheric pressure: 860 mbar to 1060 mbar T251-0214/24 Page: 7 (57) 1.3 Test Equipment used for testing Manufacturer Description Model No. Used Calibrated Calibrated until Comtest engineering, SAC2 (together with controlling equipment) SAC 3m X 2022-04-14 2025-04-14 Maturo, Turn table (2 m diameter) TT 2.0 SI X / / Maturo, Bore-sight antenna mast BAM-4.0-P X / / Maturo, positioning equipment NCD X / / Rohde & Schwarz, RFI receiver ESW 44 X 2023-03-09 2024-09-09 R&S, Ultra Broadband Antenna HL562E X 2023-09-26 2026-09-26 R&S, Horn Antenna HF907 X 2023-08-22 2026-08-22 R&S, Spectrum Analyzer FSV 40 X 2022-11-03 2024-05-03 R&S, Vector signal generator SMBV100B / / / R&S, Signal generator SMB100A / 2022-11-07 2024-05-07 R&S High resolution power meter OSP-B157W8 X 2022-11-04 2024-05-04 R&S Switch unit OSP-B157WX X 2022-11-04 2024-05-04 R&S, Line Wainwright Instruments, High pass filter High pass filter WHNX6-2555- 3500-26500 X 2023-06-01 2024-06-01 Wainwright Instruments, High pass filter WHNX6-5925- 7500-26500 / / / Wainwright Instruments, High pass filter WHW2-16340- 21500-40000 / / / Hp, Manual step attenuator 8494B 11 DB / / / Hp, Manual step attenuator 8496B 110 DB / / / PMI Low noise amplifier PEC-42-1G40G X 2023-09-18 2025-03-18 KEYSIGHT, attenuator 8491B 10 DB / / / Kambič, Temperature chamber I-190 CK / / / 1.3.1 Measurement uncertainty The following measurement uncertainty levels have been estimated for tests performed on the product, as specified in ETSI TR 100 028-2 and C63.23. This represents an expanded uncertainty expressed at 95% confidence level using a coverage factor k=2. Measurements ULAB U ETSI TR 100 028-2 U C63.23 AC Line Conducted Emission 3.2 dB / ±4,13 Spurious emission 30 – 300 MHz 4.2 dB ±6 / Spurious emission 300 – 1000 MHz 4.4 dB ±6 / Spurious emission 1 GHz – 18 GHz 5.1 dB ±6 / Spurious emission 18 GHz – 26GHz 5.6 dB ±6 / Tx spurious emission - conducted < 1.8 dB ±4 / 6 dB Emission Bandwidth < 2% ±5% / Maximum peak output power < 1 dB ±0,75 dB / 100 kHz Bandwidth of Frequency Band Edge < 0.8 dB / / Power Spectral Density < 1.3 dB ±3 dB / Occupied bandwidth (99% emission bandwidth) < 2% ±5% / Note: Measurement uncertainty calculated in accordance …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.91 mW |

Hybrid site light
Equipment Class
DTS - Digital Transmission System
Wireless earbuds
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Surface-restoration grinder
Equipment Class
DTS - Digital Transmission System
Long neck sander with BLE
Equipment Class
DTS - Digital Transmission System