FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Hua Xin Information Technology Co., Ltd/
  3. 2AMYQ-202012GD580

2AMYQ-202012GD580Robotic Vacuum Cleaner

Shenzhen Hua Xin Information Technology Co., Ltd
Robotic Vacuum Cleaner - FCC ID 2AMYQ-202012GD580 - Shenzhen Hua Xin Information Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 28, 2021
Application Purpose
Original Equipment
Date of Application
Jan 28, 2021
Equipment Note
Robotic Vacuum Cleaner
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen Hua Xin Information Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ROBOTIC VACUUM CLEANER USER MANUAL (Before using this product,please read the safety instructions below and follow all the routine safety precautions) 1. Wi-Fi Setup Instru ctions 7. Pro duc t hazardous material labeling Content 3.1 Name of Parts 3.2 Products Specifications 3.3 Product feature 4.1 Attention 4.2 Remote Controller Instructions 4.3 Operating Instructions 5.1 Side B ru sh Cleaning and Repl acement 5.2 Cleaning of Dust Box and Filter 5.3 Maintenance of Water Tank Components 5.4 Maintenance of Rollin g Bru sh Components 5.5 Maintenance of Other Components 6.1 Common F aults 6.2 Repl aceable Modules 6. Com mon Faults 4. Instruc tions for Use 5. Pro duc t Maintenan ce 2.Safety Instructi ons 3.Produ ct C omponen ts 1 Wi-Fi Setup Instructions Wi-Fi Setup Instructions To perfefct the products, we keep the right of updating the APP and the software. The final interface is subject to the actual products, thank you. Scan the QR code on the device or the QR code on the right side,or manual input the QR code/Barcode to confirm the device model,turn on the “Power switch” by following APP instructions and go to the next step. Scan the QR code in Figure 1 to download and install “WeBack” APP, or download and install from other APP stores. Figure 1 Open App, directly log in if you have a “WeBack” account; if not, you can select “New User” to sign up, and click on " " after login. Figure 2 Figure 3 Figure 4 Forget Password 2 Wi-Fi Setup Instructions To perfefct the products, we keep the right of updating the APP and the software. The final interface is subject to the actual products, thank you. Wi-Fi Setup Instructions On the device management page, click the button" " (Figure 8),in the upper right corner of the device to enter the settings page(Figure 9). Figure 5 When you see the APP enter interface Figure 5,you can start using APP to control your ROBOT.Tap the device to enter the main interface of APP (Figure 5), from this interface you can choose different cleaning modes, also to check the cleaning process/status. Tap the “more” Key(Figure 6) to enter the multi-functional panel (Figure 7). Figure 6 Figure 7 Figure 8 Figure 9 Safety Instruction 3 Before using this product,please read the safety instructions below and follow all the routine safety precautions. Safety considerations of Main Body and Accessories Please read the instructions carefully and keep them for future reference. Any operation that does not conform to the instructions may cause damage to the product. Warning 01.Do not disassemble,repair or refit the product without authorization;otherwise it may damage the product or pose a hazard. 02.Do not use the product in an environment with risk of fire or explosion. 03.This product can only use the original power adapter;otherwise the product may be damaged or catch on fire. 04.Do not stand or sit on this product;doing so could damage the product or cause it to fall over. 05.When the metal part of the power plug is dusty,please wipe it with a dry cloth. 06.The power adapter is applied to a 100-240V AC voltage.Please plug into the socket properly and keep away from children. 07.Do not wash or soak the main body and electronic accessories in the water;otherwise the product may be damaged by a short circuit. 08.Do not damage,load weight on,heat,pull,or bend it. 09.During cleaning,please pay attention to the safety of toddlers and elders at home to avoid injury. (Please pay special attention to toddlers). 10.This product is for home use.Please do not use it outdoors. 11.Do not allow metal and conductive materials to come in contact with the battery;doing so may cause a short circuit. Attentions 01.Do not touch the product with wet hands;doing so may cause an electric shock. 02.Please do not place the product in places where it could easily fall,such as tables,chairs,high platforms in room,etc. 03.The product has a sophisticated design and should be protected from long-term exposure to sunlight. 04.Please do not use the product in humid environments,such as bath-rooms. 05.Please do not place the product near cigarette butts,lighters or other open fires. 06.Please clean the product after finishing charging. 07.Please turn off the power switch on the side of the robot when the product is out of service for a long time. 08. Please check carefully to see if the power adapter is connected to the socket prior to use,to avoid damage to the robot. 4 Safety Instruction 09.Before using the product,please remove all vulerable items on the floor,such as glass, lamps,and items such as wires and curtains that may entangle with the side brush and suction passages. 10.When the dust box is full,please empty it before using again. 11.Please do not use the robot to clean the construction waste. 12.The operating temperature of the product ranges from 0 degree Celsius to 40 degrees Celsius;please do not use it in a high temperature environment. 13.Before the product is scrapped,please remove the battery from the robot.When you remove the battery,please ensure that the product is not connected to a power supply. Please recycle the battery safety or environmental protection. Safety Considerationsfr Rechargeable Battery Danger 01.Always use a dedicated battery adapter to avoid leakage,heating or rupture. 02.Do not short-circuit the battery or remove the battery;doing so may cause leakage, heating or rupture. 03.Do not transport or preserve with necklaces,hairpins,and other metal objects;doing so may lead to short circuit,resulting in leakage,heating or rupture. 04.Do not burn or heat the battery;doing so may cause leakage,heating or rupture. Attention 01. If abnormal overheating is discovered during charging,stop using it immediately to avoid leakage,heating or rupture. 02. To prolong the service life of the battery,please remove the battery and place it in a cool, dry environment if it is out of service for a long time;this will avoid leakage,heating or rupture. 03. Do not soak in water or let it come into…

Text truncated - open the document above for the full version.

Attestation Statements

Page 1 of 1 Declaration on model difference We, Shenzhen Hua Xin Information Technology Co.,Ltd. the undersigned hereby confirm that these models are identical, and all models have the same RF module and Antenna, except color and model No. for trading purpose. Product name Trade name FCC ID INPUT Model No. Robotic Vacuum Cleaner N/A 2AMYQ-202012GD580 AC100-240V 50/60HZ 19V/0.6A X580、X580r、 simum6、simum7 simum8、 simum9、M1、 N1、S3、V6、 X580pro、X581、 X582、X586、 X580s Confirmed by: Client’s signature: Client’s name / title: Suping zhan /Engineer Date2021-01-20

Cover Letter(s)

Shenzhen Hua Xin Information Technology Co.,Ltd. C5266091_X8_Ed.1 1/1 Letter of Authorization Company: Shenzhen Hua Xin Information Technology Co.,Ltd. Address: Section A,10/F,Block 1,No.7 Industrial Park,Yulu Community,Yutang,Guangming New District,Shenzhen,China Product Name: Robotic Vacuum Cleaner Model Number: X580、X580r、simum6、simum7 simum8、simum9、 M1、N1、S3、V6、X580pro、X581、X582、X586、X580s FCC Identifier: 2AMYQ-202012GD580 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Suping zhan Date: 2021-01-20 Title: Engineer Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.1 1/1 Shenzhen Hua Xin Information Technology Co.,Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2021-01-20 Subject: Request for Confidentiality FCC ID: 2AMYQ-202012GD580 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality ID Label/Location No No Attestation Statement No No External Photos No Block Diagram Schematics Test Report No No Test Setup Photos No User’s Manual Internal Photos Parts List / Tune Up RF Exposure Info Operational Description Cover Letter(s) No No SDR Software / Security Info No Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Suping zhan Title: Engineer

External Photos

FCC ID: 2AMYQ-202012GD580

ID Label/Location Info

FCC ID: 2AMYQ-202012GD580

Internal Photos

FCC ID: 2AMYQ-202012GD580 Antenna

RF Exposure Info

Report No.: PTC20120302003E-FC02 Page 1 of 7 FCC TEST REPORT FCC ID: 2AMYQ-202012GD580 Product : Robotic Vacuum Cleaner Model Name : X580、X580r、simum6、simum7、simum8、simum9、M1、N1、 S3、V6、X580pro、X581、X582、X586、X580s Brand : N/A Report No. : PTC20120302003E-FC02 Prepared for Shenzhen Hua Xin Information Technology Co.,Ltd. Section A,10/F,Block 1,No.7 Industrial Park,Yulu Community,Yutang,Guangming New District,Shenzhen,China Prepared by Precise Testing & Certification Co., Ltd Building 1, No. 6, Tongxin Road, Dongcheng Street, Dongguan, Guangdong, China Report No.: PTC20120302003E-FC02 Page 2 of 7 TEST RESULT CERTIFICATION Applicant’s name : Shenzhen Hua Xin Information Technology Co.,Ltd. Address : Section A,10/F,Block 1,No.7 Industrial Park,Yulu Community,Yutang,Guangming New District,Shenzhen,China Manufacture's name : Shenzhen Hua Xin Information Technology Co.,Ltd. Address : Section A,10/F,Block 1,No.7 Industrial Park,Yulu Community,Yutang,Guangming New District,Shenzhen,China Product name : Robotic Vacuum Cleaner Model name : X580、X580r、simum6、simum7、simum8、simum9、M1、N1、 S3、V6、X580pro、X581、X582、X586、X580s Test procedure : KDB 447498 D01 General RF Exposure Guidance v06 Test Date : Dec 08, 2020 to Jan 20, 2021 Date of Issue : Jan 20, 2021 Test Result : Pass This device described above has been tested by PTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTC, this document may be altered or revised by PTC, personal only, and shall be noted in the revision of the document. Test Engineer: Leo Yang / Engineer Technical Manager: Chris Du / Manager Report No.: PTC20120302003E-FC02 Page 3 of 7 Contents Page 2 TEST SUMMARY .............................................................................................................................................. 4 3 GENERAL INFORMATION ............................................................................................................................. 5 3.1 GENERAL DESCRIPTION OF E.U.T. ......................................................................................................... 5 4 RF EXPOSURE ................................................................................................................................................. 6 4.1 REQUIREMENTS ....................................................................................................................................... 6 4.2 THE PROCEDURES / LIMIT ........................................................................................................................ 6 4.3 MPE CALCULATION METHOD ................................................................................................................. 7 4.4 TEST RESULT .......................................................................................................................................... 7 Report No.: PTC20120302003E-FC02 Page 4 of 7 2 Test Summary Test Items Test Requirement Result Maximum Permissible Exposure (Exposure of Humans to RF Fields) 1.1307(b)(1) PASS Remark: N/A: Not Applicable Report No.: PTC20120302003E-FC02 Page 5 of 7 3 General Information 3.1 General Description of E.U.T. Product Name : Robtic Vaccum Cleaner Model Name : X580 Additional model X580r、simum6、simum7 simum8、simum9、M1、N1、S3、V6、X580pro、 X581、X582、X586、X580s Note:The appearance and color of the product are different, and the electrical principle is the same. The main test model is Simum6 Specification : 802.11b/g/n HT20 Operation Frequency : 2412-2462MHz for 802.11b/g;/ n(HT20) Number of Channel : 11 channels for 802.11b/g; n(HT20) Type of Modulation : DSSS with DBPSK/DQPSK/CCK for 802.11b; OFDM with BPSK/QPSK/16QAM/64QAM for 802.11g/n; Antenna installation : PCB antenna Antenna Gain : 3 dBi Power supply : DC19V 0.6A Adaptor lnput AC 100-240V 50/60HZ 500mA 1、YJS015D-1900600U (Dongguan Yingju Power Co., Ltd.) 2、GSCU0600S019V12E(HU NAN GIANTSUN POWER ELECTRONICS CO., LTD ) 3、DBS012A-1900600U(Guangdong Debom Technology Dongguan Co.,LTD.) DC19V 1A Adaptor lnput AC 100-240V 50/60HZ 800mA 4、YJS024W-1901000U(Dongguan Yingju Power Co., Ltd.) 5、DBS024A-1901000U (Guangdong Debom Technology Co.,LTD.) Battery: : 1、SUN-INTE-181(Sunwoda Electronic Co.,Ltd) Input 14.4V 5200mAh 2、SUN-INTE-279 (Sunwoda Electronic Co.,Ltd) Input 14.4V 5200mAh 3、SUN-INTE-273 (Sunwoda Electronic Co.,Ltd) Input 14.4V 2500mAh 4、SUN-INTE-273 (Sunwoda Electronic Co.,Ltd) Input 14.4V 2600mAh 5、SUN-INTE-172 (Sunwoda Electronic Co.,Ltd) Input 14.4V 2600mAh 6、INR18650 M26-4S1P(Yiyang Corun Battery Co.,Ltd) Hardware Version : N/A Software Version : N/A Report No.: PTC20120302003E-FC02 Page 6 of 7 4 RF Exposure Test Requirement : FCC Part 1.1307(b)(1) Evaluation Method : FCC Part 2.1091 4.1 Requirements Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device whereby a distance of 0.2 m normally can be maintained between the user and the device. 4.2 The procedures / limit (A) Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 (B) Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm2) Averaging Time |E|2,|H|2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-3…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 63 FCC TEST REPORT FCC ID: 2AMYQ-202012GD580 Product : Robotic Vacuum Cleaner Model Name : X580、X580r、simum6、simum7、simum8、simum9、M1、N1、 S3、V6、X580pro、X581、X582、X586、X580s Brand : N/A Report No. : PTC20120302003E-FC01 Prepared for Shenzhen Hua Xin Information Technology Co.,Ltd. Section A,10/F,Block 1,No.7 Industrial Park,Yulu Community,Yutang,Guangming New District,Shenzhen,China Prepared by Precise Testing & Certification Co., Ltd Building 1, No. 6, Tongxin Road, Dongcheng Street, Dongguan, Guangdong, China Report No.: PTC20120302003E-FC01 Page 2 of 63 1 TEST RESULT CERTIFICATION Applicant’s name : Shenzhen Hua Xin Information Technology Co.,Ltd. Address : Section A,10/F,Block 1,No.7 Industrial Park,Yulu Community,Yutang,Guangming New District,Shenzhen,China Manufacture's name : Shenzhen Hua Xin Information Technology Co.,Ltd. Address : Section A,10/F,Block 1,No.7 Industrial Park,Yulu Community,Yutang,Guangming New District,Shenzhen,China Product name : Robotic Vacuum Cleaner Model name : X580、X580r、simum6、simum7、simum8、simum9、M1、N1、S3、 V6、X580pro、X581、X582、X586、X580s Standards : FCC CFR47 Part 15 Section 15.247 Test procedure : ANSI C63.10:2013 Test Date : Dec 08, 2020 to Jan 20, 2021 Date of Issue : Jan 20, 2021 Test Result : Pass This device described above has been tested by PTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTC, this document may be altered or revised by PTC, personal only, and shall be noted in the revision of the document. Test Engineer: Leo Yang / Engineer Technical Manager: Chris Du / Manager Report No.: PTC20120302003E-FC01 Page 3 of 63 Contents Page 1 TEST RESULT CERTIFICATION ........................................................................................................................ 2 2 TEST SUMMARY ................................................................................................................................................... 5 3 GENERAL INFORMATION .................................................................................................................................. 6 3.1 GENERAL DESCRIPTION OF E.U.T............................................................................ 6 3.2 CHANNEL LIST ........................................................................................................... 7 3.3 TEST SITE ................................................................................................................ 10 4 EQUIPMENT DURING TEST ............................................................................................................................. 11 4.1 EQUIPMENTS LIST ................................................................................................... 11 4.2 MEASUREMENT UNCERTAINTY................................................................................ 13 4.3 DESCRIPTION OF SUPPORT UNITS .......................................................................... 14 5 CONDUCTED EMISSION ................................................................................................................................... 15 5.1 E.U.T. OPERATION ................................................................................................. 15 5.2 EUT SETUP ............................................................................................................. 15 5.3 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ........................................ 16 5.4 MEASUREMENT PROCEDURE .................................................................................. 16 5.5 CONDUCTED EMISSION LIMIT .................................................................................. 16 5.6 MEASUREMENT DESCRIPTION ................................................................................ 16 5.7 CONDUCTED EMISSION TEST RESULT .................................................................... 16 6 RADIATED SPURIOUS EMISSIONS ............................................................................................................... 19 6.1 EUT OPERATION ..................................................................................................... 19 6.2 TEST SETUP ............................................................................................................ 20 6.3 SPECTRUM ANALYZER SETUP ................................................................................ 21 6.4 TEST PROCEDURE ................................................................................................... 22 6.5 SUMMARY OF TEST RESULTS ................................................................................. 23 7 CONDUCTED SPURIOUS EMISSION ............................................................................................................. 30 7.1 TEST PROCEDURE ................................................................................................... 30 7.2 TEST RESULT .......................................................................................................... 30 8 BAND EDGE MEASUREMENT ........................................................................................................................ 32 8.1 TEST PROCEDURE ................................................................................................... 32 Report No.: PTC20120302003E-FC01 Page 4 of 63 8.2 TEST RESULT .......................................................................................................... 33 9 6DB BANDWIDTH MEASUREMENT ............................................................................................................... 36 9.1 TEST PROCEDURE ................................................................................................... 36 9.2 TEST RESULT ..............................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2AMYQ-202012GD580 Conducted Emissions Radiated Spurious Emissions From 30MHz-1000MHz Test frequency from Above 1GHz

Contact Information

Applicant

Suping Zhan
[email protected]+86-13516823366Fax: 0086-755-26665266

Technical Contact

Shenzhen Hua Xin Information Technology Co., LtdSuping zhan
[email protected]13516823366

Shenzhen · China

Test Firm

Precise Testing & Certification Co., LTD.Chris Du
[email protected]+86-769-38808222

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz105.20 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Shenzhen Hua Xin Information Technology Co., Ltd

Robotic vacuum cleaner - FCC ID 2AMYQ-2026G300 - Shenzhen Hua Xin Information Technology Co., Ltd
2AMYQ-2026G300

Robotic vacuum cleaner

Apr 01, 2026

Equipment Class

DTS - Digital Transmission System
Robotic vacuum cleaner - FCC ID 2AMYQ-2025G580 - Shenzhen Hua Xin Information Technology Co., Ltd
2AMYQ-2025G580

Robotic vacuum cleaner

Dec 12, 2025

Equipment Class

DTS - Digital Transmission System
Robotic Vacuum Cleaner - FCC ID 2AMYQ-202012GD500 - Shenzhen Hua Xin Information Technology Co., Ltd
2AMYQ-202012GD500

Robotic Vacuum Cleaner

Jan 25, 2021

Equipment Class

DTS - Digital Transmission System
Robotic Vacuum Cleaner - FCC ID 2AMYQ-202012K100 - Shenzhen Hua Xin Information Technology Co., Ltd
2AMYQ-202012K100

Robotic Vacuum Cleaner

Jan 02, 2021

Equipment Class

DTS - Digital Transmission System
Robotic Vacuum Cleaner - FCC ID 2AMYQ-2020X700MG - Shenzhen Hua Xin Information Technology Co., Ltd
2AMYQ-2020X700MG

Robotic Vacuum Cleaner

Sep 16, 2020

Equipment Class

DTS - Digital Transmission System