
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
A ctivity Tracker M/N:24652 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CJ Global Inc. Agent Authorization Company: CJ Global Inc. Address: 20-21 Wagaraw Road Bldg 30 Fair Lawn, New Jersey, NJ 0740, United States Product Name: Activity Tracker Trade Mark: N/A Model Number(s): 24652 FCC ID: 2AND8-246ATK We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2020-5-22 Name: Coby Chen Title: DIRECTOR Company: CJ Global Inc.
CJ Global Inc. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2020-05-22 Subject; Request for Confidentiality FCC ID: 2AND8-246ATK To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Coby Chen Title: DIRECTOR
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC: 23749-246ATK 8.EXTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC: 23749-246ATK Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC: 23749-246ATK Fig.5 Fig.6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC: 23749-246ATK Fig.7 Fig.8 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC: 23749-246ATK Fig.9 Fig.10 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC: 23749-246ATK Fig.11 Fig.12 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC: 23749-246ATK Fig.13 Fig.14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC: 23749-246ATK Fig.15
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC: 23749-246ATK This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 Label and Location Size: L1.5cm*W1.0cm Label Location
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC: 23749-246ATK 9.INTERIOR PHOTOGRAPHS Fig.1 Fig.2 BT Antenna SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC: 23749-246ATK Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC: 23749-246ATK Fig.5 Fig.6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC: 23749-246ATK Fig.7
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK ________________________________________________________________________ ___ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 3 FCC RF Exposure Evaluation 1. Product Information FCC ID : 2AND8-246ATK Product name : Activity Tracker Test Model : 24652 Power supply : Input:5V500mA DC 3.7V by Battery (90mAh) Operation frequency : 2402MHz-2480MHz Channel Number : 79 Channels for Bluetooth V4.0 (DSS) Channel Spacing : 1MHz for Bluetooth V4.0 (DSS) Modulation Type : GFSK, π/4-DQPSK, 8-DPSK for Bluetooth V4.0 (DSS) Bluetooth Version : V4.0 Antenna Type : Internal Antenna Antenna Gain : 0dBi(Max.) Hardware version : V1.0 Software version : V1.0 Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK ________________________________________________________________________ ___ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 3 • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices 4. Conducted Power Results <BT> Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 2.177 39 2441 2.539 78 2480 1.425 π/4DQPSK 0 2402 2.631 39 2441 2.996 78 2480 1.843 8DPSK 0 2402 2.993 39 2441 3.393 78 2480 2.218 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK ________________________________________________________________________ ___ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 3 5. Manufacturing Tolerance <BT> GFSK (Peak) Channel Channel 0 Channel 39 Channel 78 Target (dBm) 2.0 2.0 1.0 Tolerance ±(dB) 1.0 1.0 1.0 π/4DQPSK (Peak) Channel Channel 0 Channel 39 Channel 78 Target (dBm) 2.0 2.0 1.0 Tolerance ±(dB) 1.0 1.0 1…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC: 23749-246ATK Page 1 of 52 Appendix A RF Test Data for BT V4.0(BDR/EDR) (Conducted Measurement) Product Name: Activity Tracker Trade Mark: N/A Test Model: 24652 Environmental Conditions Temperature: 25 C Relative Humidity: 50% ATM Pressure: 100.0 kPa Test Engineer: Li Huan Supervised by: Li Huan A.1 Maxmum Conducted Peak Output Power Mode Channel. Maximum Peak Output Power [dBm] Limit [dBm] Verdict GFSK LCH 2.177 21 PASS MCH 2.539 21 PASS HCH 1.425 21 PASS π/4DQPSK LCH 2.631 21 PASS MCH 2.996 21 PASS HCH 1.843 21 PASS 8DPSK LCH 2.993 21 PASS MCH 3.393 21 PASS HCH 2.218 21 PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 2 of 52 Test Graphs GFSK/LCH GFSK/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 3 of 52 GFSK/HCH π/4DQPSK/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 4 of 52 π/4DQPSK/MCH π/4DQPSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 5 of 52 8DPSK/LCH 8DPSK/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 6 of 52 8DPSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 7 of 52 A.2 20dB Bandwidth Mode Channel. 20dB Bandwidth [MHz] Limit [MHz] Verdict GFSK LCH 0.9253 Not Specified PASS MCH 0.9274 Not Specified PASS HCH 0.9254 Not Specified PASS π/4DQPSK LCH 1.281 Not Specified PASS MCH 1.279 Not Specified PASS HCH 1.279 Not Specified PASS 8DPSK LCH 1.287 Not Specified PASS MCH 1.289 Not Specified PASS HCH 1.288 Not Specified PASS Test Graphs GFSK/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 8 of 52 GFSK/MCH GFSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 9 of 52 π/4DQPSK/LCH π/4DQPSK/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 10 of 52 π/4DQPSK/HCH 8DPSK/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 11 of 52 8DPSK/MCH 8DPSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 12 of 52 A.3 Occupied Bandwidth Mode Channel. Occupied Bandwidth [MHz] Limit [MHz] Verdict GFSK LCH 0.81885 Not Specified PASS MCH 0.81944 Not Specified PASS HCH 0.81719 Not Specified PASS π/4DQPSK LCH 1.1873 Not Specified PASS MCH 1.1816 Not Specified PASS HCH 1.1837 Not Specified PASS 8DPSK LCH 1.1830 Not Specified PASS MCH 1.1874 Not Specified PASS HCH 1.1887 Not Specified PASS Test Graphs GFSK/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 13 of 52 GFSK/MCH GFSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 14 of 52 π/4DQPSK/LCH π/4DQPSK/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 15 of 52 π/4DQPSK/HCH 8DPSK/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 16 of 52 8DPSK/MCH 8DPSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 17 of 52 A.4 Carrier Frequency Separation Mode Channel. Carrier Frequency Separation [MHz] Limit [MHz] Verdict GFSK LCH 0.961 0.618 PASS MCH 0.856 0.618 PASS HCH 1.162 0.618 PASS π/4DQPSK LCH 1.286 0.854 PASS MCH 1.262 0.854 PASS HCH 1.264 0.854 PASS 8DPSK LCH 0.996 0.859 PASS MCH 1.316 0.859 PASS HCH 0.898 0.859 PASS Test Graphs GFSK/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 18 of 52 GFSK/MCH GFSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 19 of 52 π/4DQPSK/LCH π/4DQPSK/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 20 of 52 π/4DQPSK/HCH 8DPSK/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 21 of 52 8DPSK/MCH 8DPSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 22 of 52 A.5 Hopping Channel Number Mode Channel. Number of Hopping Channel [N] Limit [N] Verdict GFSK Hop 79 >=15 PASS π/4DQPSK Hop 79 >=15 PASS 8DPSK Hop 79 >=15 PASS Test Graphs GFSK/Hop π/4DQPSK/Hop SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 23 of 52 8DPSK/Hop SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 24 of 52 A.6 Dwell Time Mode Packet Channel Burst Width [ms/hop/ch] Total Hops[hop*ch] Dwell Time[s] Limit [s] Verdict GFSK DH5 LCH 2.89 106.7 0.308 0.4 PASS DH5 MCH 2.89 106.7 0.308 0.4 PASS DH5 HCH 2.89 106.7 0.308 0.4 PASS π/4DQPSK 2DH5 LCH 2.89 106.7 0.307 0.4 PASS 2DH5 MCH 2.89 106.7 0.307 0.4 PASS 2DH5 HCH 2.89 106.7 0.307 0.4 PASS 8DPSK 3DH5 LCH 2.89 106.7 0.307 0.4 PASS 3DH5 MCH 2.89 106.7 0.307 0.4 PASS 3DH5 HCH 2.89 106.7 0.307 0.4 PASS Test Graphs GFSK_DH5/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 25 of 52 GFSK_DH5/MCH GFSK_DH5/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 26 of 52 π/4DQPSK _2DH5/LCH π/4DQPSK _2DH5/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 27 of 52 π/4DQPSK _2DH5/HCH 8DPSK _3DH5/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 28 of 52 8DPSK _3DH5/MCH 8DPSK _3DH5/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK IC ID: 23749-246ATK Page 29 of 52 A.7 RF Conducted Spurious Emissions Mode Channel Pref [dBm] Max. Level [dBm] Limit [dBm] Verdict GFSK LCH 1.824 -37.471 -18.176 PASS MCH 2.069 -38.164 -17.931 PASS HCH 0.973 -37.645 -19.02…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK Report No.: LCS200509037AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 34 FCC TEST REPORT FOR CJ Global Inc. Activity Tracker Test Model: 24652 Prepared for : CJ Global Inc. Address : 20-21 Wagaraw Road Bldg 30 Fair Lawn, New Jersey, NJ 0740, United States Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : May 11, 2020 Number of tested samples : 1 Serial number : Prototype Date of Test : May 11, 2020 ~ May 14, 2020 Date of Report : May 18, 2020 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK Report No.: LCS200509037AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 34 FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCS200509037AEA Date of Issue ................................... : May 18, 2020 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Testing Location/ Procedure ........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : CJ Global Inc. Address ........................................... : 20-21 Wagaraw Road Bldg 30 Fair Lawn, New Jersey, NJ 0740, United States Test Specification Standard .......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No. ..................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : Activity Tracker Trade Mark ...................................... : N/A Test Model ...................................... : 24652 Ratings ............................................ : Input:5V500mA DC 3.7V by Battery (90mAh) Result ........................................... : Positive Compiled by: Supervised by: Approved by: Jayden Zhuo/ File administrators Jin Wang/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK Report No.: LCS200509037AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 34 FCC -- TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS200509037AEA May 18, 2020 Date of issue Test Model........................... : 24652 EUT......................................... : Activity Tracker Applicant............................... : CJ Global Inc. Address.................................. : 20-21 Wagaraw Road Bldg 30 Fair Lawn, New Jersey, NJ 0740, United States Telephone............................... : / Fax.......................................... : / Manufacturer........................ : CJ Global Inc. Address................................... : 20-21 Wagaraw Road Bldg 30 Fair Lawn, New Jersey, NJ 0740, United States Telephone............................... : / Fax.......................................... : / Factory................................... : CJ Global Inc. Address................................... : 20-21 Wagaraw Road Bldg 30 Fair Lawn, New Jersey, NJ 0740, United States Telephone............................... : / Fax.......................................... : / SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK Report No.: LCS200509037AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 34 Revision History Revision Issue Date Revisions Revised By 000 May 18, 2020 Initial Issue Gavin Liang SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AND8-246ATK Report No.: LCS200509037AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 34 TABLE OF CONTENTS Description Page 1.GENERAL INFORMATION ......................................................................................................... 6 1.1 Description of Device (EUT) .............................................................................................................. 6 1.2 Support equipment List ....................................................................................................................... 6 1.3 External I/O Cable ............................................................................................................................... 6 1.4 Description of Test Facility ................................................................................................................. 6 1.5 Statement of the Measurement Uncertainty ............................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.20 mW |
Bobcat Neckband Headphones
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
3-In-1 Fast Wireless Charging Station
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
TWS EARBUDS
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter4-in-1 Fast Wireless Charging Station With Lamp
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Karaoke Wireless Microphone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter