FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TianJin HuaLai Technology Co.,Ltd./
  3. 2ANJHSS100EX

2ANJHSS100EXRoku Entry Sensor

TianJin HuaLai Technology Co.,Ltd.
Roku Entry Sensor - FCC ID 2ANJHSS100EX - TianJin HuaLai Technology Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Mar 27, 2023
Application Purpose
Original Equipment
Date of Application
Mar 27, 2023
Equipment Note
Roku Entry Sensor
Frequency Range
906.80000000 - 913.20000000
Company
TianJin HuaLai Technology Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WELCOME TO WYZE IN THE BOX Wyze Home Monitoring is an automated monitoring service designed to keep your home safe and report threats even when you can’t review Events by yourself. During an emergency, an agent from the monitoring center will reach out to you and dispatch authorities if necessary. Wyze Sense Hub × 1 Wyze Keypad × 1 Contact Sensor × 2 Wyze Entry Motion Sensor × 1 Quick Start Guide × 1 Window Decals × 2 Hub The brains of your new security system. The Sense Hub connects sensors to the Wyze app and has a built-in siren to ward to your home internet via WiFi or Ethernet o would-be intruders. Connect the Hub and make sure it’s placed in a central location for best coverage. Keypad Placed near your door, the Wyze Sense Keypad makes it easy to quickly arm and disarm your system. Motion Sensor Designed to detect people and not pets. Place it high on the wall for best coverage. Entry Sensor Always know when your doors are open or left open. Mount on primary entry/exits and windows. ACTIVATION To activate Wyze Home Monitoring, enter your activation code through the following link: services.wyze.com Note: If you ordered a Wyze Core Starter Kit online, you may activate your Home Monitoring through your email. Total installation time should take less than 40 minutes. Before you get started, make sure you have a step ladder or stool handy and a screwdriver if you plan to mount your motion sensor in a corner. Make sure to follow the in-app guide to ensure your devices are added to your Wyze account and installed properly. INSTALLATION & SETUP SETUP Control and monitor your entire home via the Wyze app. To get started, simply download the Wyze app to your mobile phone and log in or create an account. 1 HARDWARE OVERVIEW To start your Home Monitoring setup, navigate to the Wyze app, and go into the Home Monitoring Tab. When your Home Monitoring license is activated, you can tap on the ‘Start Setup' button. This will guide you through the installation process. Not seeing this screen? Go to services.wyze.com to activate. WYZE SENSE HUB WYZE SENSE KEYPAD Ensure your phone’s Bluetooth is turned on Click on the Monitoring tab in the bottom navigation bar of the Wyze app Use the included cables to plug the device into a nearby outlet and router. If your router is not located in a central location, you can also connect the Hub to WiFi Raise the two antennas Press the Reset button on the back of the device Follow the in-app instructions to complete setup After the Hub is set up, you will be prompted to add additional devices. Click on each device to begin setup. batteries Replace the battery cover Slide the mounting plate and battery cover o to insert 3 AA Press the Reset button Name your keypad Clean the desired mounting location and wait for it to dry completely Use the adhesive back or screws to secure the mounting plate to the wall Attach your keypad to the mounting plate NOTE: the adhesive is semi-permanent and may peel paint when removed The Keypad is designed to be mounted on the wall near your door and connects to the Hub. MOTION SENSOR Remove the plastic battery tab. If you previously removed it, press and hold the reset button until the status light flashes 3 times Name your sensor Clean the desired mounting location and wait for it to dry completely Use the adhesive backing to secure the mounting plate to the desired location Use screws for optional added security Attach sensor to mounting plate Mount on wall or corner ~7 feet high Avoid placing it near heat sources (vents, lamps, etc.) Ensure Wyze logo is on the LEFT side 123 PIN ENTRY & EXIT DELAYS Control how much time you allow to disarm your system before an alarm. You may choose between 0 to 180 seconds. If you do not disarm your system, an alarm will begin. Entry Delay Control the amount of time for people to leave your home before the system is armed. You may choose between 0 to 180 seconds. Exit Delay Change your Entry & Exit Delay Go into the Home Monitoring Tab Scroll to the bottom to find the Home Monitoring Settings button Navigate to Entry & Exit Delay Choose your delay time for Home or Away 1 2 3 4 1 Enter your PIN and then press the checkmark and your desired mode Your PIN will be used to disarm your system or cancel an Emergency Response request. This PIN will be entered through the Wyze Sense Keypad or through the Wyze app. Go into the Home Monitoring Tab Scroll to the bottom and tap into Home Monitoring Settings Tap Home & Away Choose the sensors that you would like for each mode HOW TO ARM & DISARM YOUR SYSTEM HOW TO CHOOSE SENSORS FOR HOME & AWAY MODE Arm/Disarm through Keypad What is a PIN? Press the Disarmed, Home, or Away button in the Home Monitoring tab Arm/Disarm through Wyze app NEED HELP? Contact our support team: https://support.wyze.com Join our Community: https://wyze.com/community Scan the QR code to learn more USER MANUAL Wyze Home Monitoring 2 1 2 3 4 5 6 1 2 3 4 5 6 7 1 2 3 4 5 6 1 1 1 2 3 4 Activate through your Keypad Press & hold the Emergency Button on the right side of your Keypad Activate through Wyze app Go into the Home Monitoring Tab Tap the Emergency Button icon on the top right side Confirm on the dialog to activate the Emergency Button EMERGENCY BUTTON The Emergency Button will be used to manually activate Alarm Response. Alarm Response will trigger an alarm and notify our monitoring service provider, Noonlight. SAFE WORDS A Safe Word is a secret word chosen by you and used by your monitoring agent to verify your safety. It is important to choose a word that can be pronounced clearly in high-stress situations. During an active alarm, our monitoring agent will contact you to confirm your safety. If you are unable to repeat your safe word, our monitoring agent may dispatch emergency services to your location. What is a Safe Word? Change your Safe Word Go into the Home Monitoring Tab Scroll to the bottom to find the Home Monitoring Settings button Navigate to PIN & Safe Word Tap Safe Word …

Text truncated - open the document above for the full version.

Attestation Statements

Rev 1/26/2023 TianJin HuaLai Technology Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2023/3/23 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2ANJHSS100EX TianJin HuaLai Technology Co.,Ltd. (“Guoqing Wang”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, ------------------------------- Guoqing Wang Rev 1/26/2023 TianJin HuaLai Technology Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2023/3/23 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2ANJHSS100EX TianJin HuaLai Technology Co.,Ltd. (“Guoqing Wang”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, ------------------------------- Guoqing Wang

Attestation Statements

TianJin H No.10 Jin Date: 03/ Federal C Authoriza 7435 Oa Columbia Grantee US TianJin H Agent, LL 2ANJHS TianJin HuaLai Technology Co.,Ltd. United S t marketing Commiss later. FCC US the desi g Technolo 2ANJHS Designa t Company FRN: 003 Address: Contact P Phone: 7 Email: Su Sincerely Company Company Signatur e HuaLai Tech nPing Road, Y /23/2023 Communicat ation and Ev kland Mills R a, MD 21046 Code: 2ANJ S Agen HuaLai Techn LC to accept S100MX; FC tates for no l g and import sion-related a Agent, LLC, gnated agent ogy Co.,Ltd.fo S100KX; FC ted Agent In y Name: FCC 33402884 3722 Illinoi s Person: Tim 708-571-3148 upport@FCC y, y: TianJin HuaLai Technology Co.,Ltd. y Representa e: nology Co.,L Ya An Street tions Comm valuation Div Road 6 JH t – Atte nology Co.,L t service of p CC ID: 2ANJ ess than one tation of the a administrativ accepts as o t for the purp or (FCC ID: 2 CC ID: 2ANJ nformation: C US Agent, s Avenue, Sa Payne 8 CUSAgent.co ative: Guoqin Ltd. ,Nankai Distr ission vision station Ltd.certifies, t process on ou JHSS100KX , accepts to maintain an agent of service of process in the e year after e applicable eq ve or judicial of the date o pose of accep 2ANJHSS10 HSS100EX) LLC aint Charles, om ng Wang rict Tianjin, C Statem that as of [DA ur behalf for ; FCC ID: 2 A either the gra quipment wit proceeding i of the filing of pting service 00BX; FCC I ). IL, 60174, U Designat Designat Signature China ent / Pa ATE], we hav (FCC ID: 2A ANJHSS100 antee has pe thin the U.S. involving the f this applica e of process o D: 2ANJHSS USA ted Agent: FC ted Agent Re e: art 2.91 ve designate ANJHSS100B EX). ermanently te , or the conc e equipment, ation, the obli on behalf of S100MX; FC CC US Agen epresentative 1(d)(7) ed FCC US BX; FCC ID: erminated all clusion of any whichever is igation of bei TianJin Hua CC ID: nt, LLC e: Tim Payne : l y s ing Lai e

Cover Letter(s)

TianJin HuaLai Technology Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2023/3/23 SUBJECT: FCC Application for (FCC ID: 2ANJHSS100EX) To Whom It May Concern: I, the undersigned, hereby states this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules, and will apply the Supplier's Declaration of Conformity procedure to the class B computer peripheral portion of this composite device. I understand the following FCC requirements: 1. Devices subject to the SDoC procedure are required to be tested to show compliance with the FCC technical regulations by a recognized accredited testing laboratory. The testing laboratory must be accredited by a Commission approved accreditation body or designated under the terms of a government-to-government Mutual Recognition Agreement (MRA). A listing of those accredited testing laboratories that have been recognized by the Commission is published on the FCC Webpage: https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm (Select the "accredited" option to search for FCC recognized accredited test firms.) 2. Pt 2.1077 contains the list of information that must be included in the Supplier's Declaration of Conformity, which must be supplied with each product sold. The SDoC compliance info shall be included in the User’s Manual or as a separate sheet. The info must contain the name, address, and phone number of the responsible party, which must be located within the United States. According to 2.909(b), the responsible party is either the Manufacturer or if the product is imported the Importer. Regards, TianJin HuaLai Technology Co.,Ltd. ------------------------------- Guoqing Wang

Cover Letter(s)

\\192.168.0.6\rf无线2\3.2023年案件\3月\邓飘\2.15-C230131001-LCSA021423041E-陈婉君-Entry Sensor-FCCID\form\POA_Letter.docx TianJin HuaLai Technology Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2023/3/23 SUBJECT: FCC Application for (FCC ID: 2ANJHSS100EX) To Whom It May Concern: We, the undersigned, hereby authorize Gavin Liang at Shenzhen LCS Compliance Testing Laboratory Ltd. on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Shenzhen LCS Compliance Testing Laboratory Ltd.on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, ------------------------------- Guoqing Wang

Cover Letter(s)

Rev 11/20/07 TianJin HuaLai Technology Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2ANJHSS100EX Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram “Block Diagram.pdf” Schematics “Schematic.pdf” Operational Description “Operation Description.pdf” The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below: confidentiality period is 180 days. Exhibit Type File Name User Manual “User Manual.pdf” External Photos “External Photos.pdf” Internal Photos “Internal Photos.pdf” Test Setup Photos “Test Setup Photos.pdf” Sincerely, ------------------------------- Guoqing Wang

External Photos

Page 1 of 4 FCC ID: 2ANJHSS100EX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2ANJHSS100EX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2ANJHSS100EX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2ANJHSS100EX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7

ID Label/Location Info

Page 1 of 1 FCC ID: 2ANJHSS100EX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Label and Location Size: L: 2.9cm*W: 0.95cm Label Location

Internal Photos

Page 1 of 4 FCC ID: 2ANJHSS100EX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2ANJHSS100EX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Antenna Page 3 of 4 FCC ID: 2ANJHSS100EX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2ANJHSS100EX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8

RF Exposure Info

Page 1 of 4 FCC ID: 2ANJHSS100EX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information Product name Roku Entry Sensor Test Model SS100EX Power Supply DC 1.5V By AAA Battery Hardware Version DWS3U-V2 V1.5 Software Version 6.2.0.50 Frequency Range 906.8MHz, 910MHZ, 913.2MHz Channel Number 3 Modulation Type GFSK Antenna Description FPC Antenna, 0.9dBi (max.) Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Devices Page 2 of 4 FCC ID: 2ANJHSS100EX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 2.Evaluation method and Limit Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–2019: IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices. 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Uncontrolled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density Page 3 of 4 FCC ID: 2ANJHSS100EX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 5. Antenna Information EUT can only use antennas certificated as follows provided by manufacturer; Antenna type and antenna number Operate frequency band Maximum antenna gain Notes FPC Antenna 906.8-913.2MHz 0.9dBi SRD Antenna 6. Conducted Power Test Procedure TX frequency range: 906.8MHz, 910MHZ, 913.2MHz Mode Channel Frequency (MHz) Field Strength (dBuV/m @3m) Maximum Conducted Output Power (dBm) GFSK 1 906.8 77.71 -17.45 2 910 77.32 -17.84 3 913.2 78.39 -16.77 Field Strength: dBuV/m @3m Maximum Conducted Output Power: EIRP=E-104.7+20logD=E-104.7+20log3 Turn-up Channel Channel 1 Channel 2 Channel 3 Target (dBm) -17.0 -17.0 -16.0 Tolerance ± (dB) 1.0 1.0 1.0 Page 4 of 4 FCC ID: 2ANJHSS100EX Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 7. Evaluation Results As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =20cm, as well as the gain of the used antenna refer to antenna information, the RF power density can be obtained. [SRD] Modulation Type Outp…

Text truncated - open the document above for the full version.

Test Report

SPECIFICATION SPECIFICATION SHEETFORAPPROVAL ( Revision : R : A1 ) CUSTOMER(客户名称)TianjinHualTechnologyCo.,LTD CSP/N(客户机种)DWS3U-V2doormagnetic(A304-032F) PARTNAME( 品名 ) WIFIAntenna FREQUENCY( 频率 ) 906.8-913.2MHz ZTXNO.(物料编号)1.03.02523 DATE( 日期 ) 2021-01-22 CUSTOMER QA CHECKED ME CHECKED RF CHECKED MANAGER CHECKED ZHONGTIANXUNTECHNOLOGYCO.,LTD MANAGER CHECKED MANAGER CHECKED ME CHECKED RF CHECKED LISTER LiulipingZouyi Address:No.34,ShilongAvenue,ShiyanTown,BaoanDistrict,Shenzhen,(TengdaIndustrialPark)518000 Tel.:0755-27588320Fax:0755-27588045http://www.chinaztx.com Remark(备注): Sign(客户确认签字盖章): ANTENNASPECIFICATION CUSP/N: DWS3U-V2doormagnetic(A304-032F) ApplicationDate:Jan,22,2021Rev:R:A1 ZTXP/N: DWS3U-V2doormagnetic(A304-032F) Editor:Page 1 of9 Revisionhistory NODateState A12022-01-22Thefirstedition ANTENNASPECIFICATION CUSP/N: DWS3U-V2doormagnetic(A304-032F) ApplicationDate:Jan,22,2021Rev:R:A1 ZTXP/N: DWS3U-V2doormagnetic(A304-032F) Editor:Page 2 of9 Index Revisionhistory 1 lndex 2 1MechanicalSpecification 3 1-1 MechanicalSpecification(WIFIAntenna) 3 2Antennatestdata 4 2-1VSWR&Returnlossplot&SmithChart 4 2-2No-sourcetestdata 4 2-3Matchingcircuit 5 2-4Environmenttreatment 5 2-52D/3DRadiationPatternResults 6 3 TestReport 7 4Salt-Spraytest 8 5EnvironmentCharacteristic 9 ANTENNASPECIFICATION CUSP/N: DWS3U-V2doormagnetic(A304-032F) ApplicationDate:Jan,22,2021Rev:R:A1 ZTXP/N: DWS3U-V2doormagnetic(A304-032F) Editor:Page 3 of9 1.MechanicalSpecification 1-1MechanicalConfiguration(WIFIAntenna) ANTENNASPECIFICATION CUSP/N: DWS3U-V2doormagnetic(A304-032F) ApplicationDate:Jan,22,2021Rev:R:A1 ZTXP/N: DWS3U-V2doormagnetic(A304-032F) Editor:Page 4 of9 2.Antennatestdata 2-1VSWR&Returnlossplot&SmithChart 2-2No-sourcetestdata ANTENNASPECIFICATION CUSP/N: DWS3U-V2doormagnetic(A304-032F) ApplicationDate:Jan,22,2021Rev:R:A1 ZTXP/N: DWS3U-V2doormagnetic(A304-032F) Editor:Page 5 of9 2-3Matchingcircuit 2-4Environmenttreatment N/A ANTENNASPECIFICATION CUSP/N: DWS3U-V2doormagnetic(A304-032F) ApplicationDate:Jan,22,2021Rev:R:A1 ZTXP/N: DWS3U-V2doormagnetic(A304-032F) Editor:Page 6 of9 2-52D/3DRadiationPatternResults ANTENNASPECIFICATION CUSP/N: DWS3U-V2doormagnetic(A304-032F) ApplicationDate:Jan,22,2021Rev:R:A1 ZTXP/N: DWS3U-V2doormagnetic(A304-032F) Editor:Page 7 of9 3.TestReport ANTENNASPECIFICATION CUSP/N: DWS3U-V2doormagnetic(A304-032F) ApplicationDate:Jan,22,2021Rev:R:A1 ZTXP/N: DWS3U-V2doormagnetic(A304-032F) Editor:Page 8 of9 4.Salt-Spraytest customer name TianjinHualai product name DWS3U-V2door magnetic(A304-032F) WIFIAntenna date2020/11/11 Product material FPC proving time 48Hquantity5PCS time quantum testconditiontestcriteria bear fruit Remarks 0-6Hours Saltspraytester: saltliquid:NaCl(no water);concentration 5%±1%;pHvalue: 6.5~7.2;laboratory temperature:32-38°C; compressedair pressure:1.0±0.01 (KG/M2)Spray amount: 1.0~2.0ML/80CM2/H. Relativehumidity: 85%±2%;placement angleoftestproduct: 30degrees+/-10 degrees;saltspray duration:48h, Productsurfacewithoutrust point,oxidation,corrosion, coating(coating)layeroffand otheradversephenomena OK 2020.11.09 16:00AM beginning 6-12Hours 12-18 Hours 18-24 Hours 24-30 Hours 2020.11.11 16:00AM stop 30-36 Hours 36-42 Hours 42-48 Hours Morethan 48hours Theproductsurfacewithoutrust point,oxidation,corrosion, coating(coating)layeroff1%of theproductarea conclusionSaltSprayTestOK testclerkLiQingliexamineandverifyYiAilingRatifyHuChunmei ANTENNASPECIFICATION CUSP/N: DWS3U-V2doormagnetic(A304-032F) ApplicationDate:Jan,22,2021Rev:R:A1 ZTXP/N: DWS3U-V2doormagnetic(A304-032F) Editor:Page 9 of9 5.EnvironmentCharacteristic NO.ITEMTESTCONDITIONSPECIFICATION 5-1 HighTemperature/Humidity StorageTest(nonoperating) 1.Temperature:+70±2°C 2.Humidity:90~95%RH 3.Time:48hrs Nomaterialdeformationis allowed. TheVSWR,Gain,Radiation Patternmustbemet specificationsafterthesetest. 5-2 LowTemperature/Humidity StorageTest(nonoperating) 1.Temperature:-30±2°C 2.Humidity:0%RH 3.Time:48hrs

Test Report

Page 1 of 33 FCC ID: 2ANJHSS100EX Report No.: LCSA021423041EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FOR TianJin HuaLai Technology Co.,Ltd. Roku Entry Sensor Test Model: SS100EX Prepared for : TianJin HuaLai Technology Co.,Ltd. Address : No.10 JinPing Road, Ya An Street,Nankai District Tianjin, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : February 15, 2023 Number of tested samples : 2 Sample No. : A021423041-1, A021423041-2 Sample number : Prototype Date of Test : February 15, 2023 ~ March 16, 2023 Date of Report : March 16, 2023 Page 2 of 33 FCC ID: 2ANJHSS100EX Report No.: LCSA021423041EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C (15.249) Report Reference No. ................. : LCSA021423041EA Date of Issue................................... : March 16, 2023 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : TianJin HuaLai Technology Co.,Ltd. Address ........................................... : No.10 JinPing Road, Ya An Street,Nankai District Tianjin, China Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.249) / ANSI C63.10: 2013 Test Report Form No. ..................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : Roku Entry Sensor Trade Mark ..................................... : Roku Test Model ...................................... : SS100EX Ratings ............................................ : DC 1.5V By 1*AAA Battery Result ........................................... : Positive Compiled by: Supervised by: Approved by: Vera Deng/Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 33 FCC ID: 2ANJHSS100EX Report No.: LCSA021423041EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan Distric…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Guoqing Wang(manager)
[email protected]18202589622Fax: 87614860

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C906.8 MHz - 913.2 MHz-
Confidentiality
Long Term

Other Applications from TianJin HuaLai Technology Co.,Ltd.

Roku Monitoring Hub - FCC ID 2ANJHSS100BX - TianJin HuaLai Technology Co.,Ltd.
2ANJHSS100BX

Roku Monitoring Hub

Mar 27, 2023

Equipment Class

DTS - Digital Transmission System
Roku Keypad - FCC ID 2ANJHSS100KX - TianJin HuaLai Technology Co.,Ltd.
2ANJHSS100KX

Roku Keypad

Mar 27, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Roku Motion Sensor - FCC ID 2ANJHSS100MX - TianJin HuaLai Technology Co.,Ltd.
2ANJHSS100MX

Roku Motion Sensor

Mar 27, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wyze Chime - FCC ID 2ANJHWDBC1 - TianJin HuaLai Technology Co.,Ltd.
2ANJHWDBC1

Wyze Chime

Aug 06, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
WYZE CAM V2 - FCC ID 2ANJHWYZEC02 - TianJin HuaLai Technology Co.,Ltd.
2ANJHWYZEC02

WYZE CAM V2

Jul 06, 2020

Equipment Class

DTS - Digital Transmission System