Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
REGISTER ONLINE! ENREGISTREMENT EN LIGNE! DOG DRINKING FOUNTAIN SCAN QR CODE TO GET STARTED! SCANNER LE CODE QR POUR COMMENCER! QR-CODE SCANNEN UND LOSLEGEN! ¡ESCANEA PARA EMPEZAR! USER MANUAL • GUIDE DE L’UTILISATEUR • GEBRAUCHSANLEITUNG • MANUAL DEL USUARIO • MANUAL DO USUÁRIO GEBRUIKERSHANDLEIDING • INSTRUKCJA UŻYTKOWANIA • FELHASZNÁLÓI KÉZIKÖNYV • MANUALE UTENTE • BRUGSANVISNING ИНСТРУКЦИЯ ПО ПРИМЕНЕНИЮ • ANVÄNDARHANDBOK • UŽIVATELSKÁ PŘÍRUČKA • MANUAL DE UTILIZARE • KÄYTTÄJÄN OPAS #96422 - 96423 2 3 SAFETY TIPS INSTRUCTIONS PER- TAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS WARNING: To guard against injury, basic safety precautions should be observed, including the following: 1 READ AND FOLLOW ALL SAFETY INSTRUCTIONS and all the important notices on the appliance before using the pump. Failure to do so may result in damage to this appliance. 2 DANGER – To avoid possible electrical shock, special care should be taken since water is employed in the use of this product. For each of the following situations, do not attempt repairs yourself; return the pump to an authorized service facility for service if it is still under warranty or discard the appliance. A If the pump shows any sign of abnormal water leakage, disconnect the power supply cord and remove pump from water. B Carefully examine the appliance after installation. It should not be plugged in if there is water on parts not intended to be wet. C Do not operate the appliance if it has a damaged electrical cord or plug, or if it is malfunctioning or if it is dropped or damaged in any manner. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Never cut the cord. D The electrical outlet should always be above the level of the appliance. If the plug or outlet does get wet, DO NOT unplug the electrical cord. Disconnect the fuse or circuit breaker that supplies power to the appli- ance, then unplug and examine for presence of water in the outlet. 3 This appliance is not intended for use by persons (including children) with significantly impaired physical or mental capabilities, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should always be supervised to ensure that they do not play with the appliance. 4 To avoid injury, do not contact moving or hot parts. 5 CAUTION Always unplug or disconnect the appliance from the outlet before putting on or taking off parts and while the equipment is being installed, maintained or handled. When inserting or removing the pump from the water, pull out the main electrical plug. Never connect or disconnect the pump plug when there is water in the reservoir. Never yank the cord to pull the plug from the outlet. Grasp the plug and pull to disconnect. Always unplug an appliance from an outlet when not in use. Never lift the pump by the cord. 6 CAUTION: THIS DEVICE INCLUDES A PET DRINKING FOUNTAIN PUMP. The pump has been evaluated for use with freshwater only. Do not use this pump for other than its intended use (i.e. don’t use it in swimming pools, bath tubs, etc.). The use of attachments not recommended or sold by the appliance manufacturer may cause an unsafe condition. • Do not use the pump in swimming pools or other situations where people are immersed. • This pump is suitable for use in water temperatures up to 35ºC. • Do not use this pump with inflammable liquids. 7 Do not install or store the appliance where it will be exposed to tem- peratures below freezing. Shelter the pump from direct sunlight. 8 Ensure that the appliance is placed on a flat, even surface. Monitor the appliance regularly. Do not leave the appliance unattended for extended periods. Do not allow the pump to run dry. The pump must be immersed in water completely. This pump must never operate outside of water. 9 If an extension cord is necessary, ensure the connection is watertight and dust proof. A cord with a proper rating should be used. A cord rated for less amperes or watts than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled. 10 Do not use this unit outdoors. This unit is for indoor use only. 11 WARNING Do not operate the UV-C emitter when it is removed from the appliance enclosure. • This appliance contains a UV-C emitter. • Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation. UV-C radiation may, even in little doses, cause harm to the eyes and skin. • Appliances that are obviously damaged must not be operated. • Replacement of the UV-C emitter by the user is not allowed. The UV-C emitter is not available as a spare part. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Only the faithful observation of these installation, electrical and main- tenance guidelines will ensure the safe and efficient use of this drinking fountain. RECYCLING: This product bears the selective sorting symbol for waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European Directive 2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment. Check with your local Environmental Agency for possible disposal instructions or take to an official council registered refuse collection point. Electronic products not included in the selective sorting process are potentially dangerous for the environment and human health due to the presence of hazardous substances. EN 4 5 1 2 3 4 5 8 7 7a 6b 6 6e 6c 9 CONTENTS / CONTENU / INHALT / CONTENIDO / CONTEÚDO / INHOUD / ZAWARTOŚĆ / TARTALOM / CONTENUTO / INDHOLD / СОСТАВ КОМПЛЕКТА / INNEHÅLL / OBSAH / CUPRINS / SISÄLTÖ EN All pictures shown in the manual are for illustration purposes only. The actual product may vary due to product enhancement. DE Alle in dieser Gebrauchs…
Text truncated - open the document above for the full version.
Rolf C. Hagen Inc Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 7/4/2024 U.S. Agent Designation Rolf C. Hagen Inc acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2ANPT-96423): Name and company of U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of Rolf C. Hagen Inc. Rolf C. Hagen Inc with the FRN 0026829036 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sinc erely, Signature Robert Reid Aquatic Brands Manager Rolf C. Hagen Inc Signature Tim Payne Manager FCC US Agent, LLC 48_[model] US_Agent_2.911(d)(7)-U, V05
Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: Rolf C. Hagen Inc. Address: 20500 Trans Canada Hwy Baie-d'Urfe, Quebec H9X0A2, Canada Phone: +1-514 4570914 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-06-25 Printed Name of Signee / Title: Robert Reid / Aquatic Brands Manager Company: Rolf C. Hagen Inc. Address: 20500 Trans Canada Hwy Baie-d'Urfe, Quebec H9X0A2, Canada Phone: +1-514 4570914 Fax: +1-514 4578246 Email: [email protected]
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2ANPT-96423 96423 We, applicant Company Name: Rolf C. Hagen Inc. Address: 20500 Trans Canada Hwy Baie-d'Urfe, Quebec H9X0A2, Canada Phone: +1-514 4570914 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-06-25 Printed Name of Signee / Title: Robert Reid / Aquatic Brands Manager Company: Rolf C. Hagen Inc. Address: 20500 Trans Canada Hwy Baie-d'Urfe, Quebec H9X0A2, Canada Phone: +1-514 4570914 Fax: +1-514 4578246 Email: [email protected]
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2ANPT-96423 96423 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: the Operational Description the Block Diagram the Schematics the Part List the Tune up Tolerance The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2024-06-25 Printed Name of Signee / Title: Robert Reid / Aquatic Brands Manager Company: Rolf C. Hagen Inc. Address: 20500 Trans Canada Hwy Baie-d'Urfe, Quebec H9X0A2, Canada Phone: +1-514 4570914 Fax: +1-514 4578246 Email: [email protected]
Page 1 of 5 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 5 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 5 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 5 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 5 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9
Page 1 of 1 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L 31.5cm x W 30.0cm) Zeus Oasis Plus Fountain Model: 96423 FCC ID: 2ANPT-96423 Label Location
Page 1 of 5 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 5 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 5 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 5 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 5 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 BT/WIFI Antenna
Page 1 of 5 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Maximum Permissible Exposure Report 1. Product Information EUT : Zeus Oasis Plus Fountain Test Model : 96423 Power Supply : Input:100-240V~ ,50/60Hz, 0.4A Max Output: 5V2A, 10.0W Hardware Version : V0.1 Software Version : V1.5.6 Bluetooth Frequency Range : 2402MHz~2480MHz Channel Number : 79 channels for Bluetooth V4.1(DSS) Channel Spacing : 1MHz for Bluetooth V4.1 (DSS) Modulation Type : GFSK for Bluetooth V4.1(DSS) Bluetooth Version : V4.1 Antenna Description : PCB Antenna, 2.21dBi (Max.) WIFI(2.4G Band) Frequency Range : 2412MHz~2462MHz Channel Spacing : 5MHz Channel Number : 11 Channels for 20MHz bandwidth (2412~2462MHz) 7 Channels for 40MHz bandwidth (2422~2452MHz) Modulation Type : IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) Antenna Description : PCB Antenna, 2.21dBi (Max.) Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Mobile Devices 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum Page 2 of 5 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–2019: IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices. 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Uncontrolled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna Page 3 of 5 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 5. Antenna Information EUT can only use antennas certificated as follows provided by manufacturer; Internal/External Identification Antenna type and antenna number Operate frequency band Maximum antenna gain Notes Internal PCB Antenna 2400-2500MHz 2.21dBi BT/WIFI Antenna 6. Conducted Power <BT> Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 -0.83 39 2441 -0.22 78 2480 0.03 [2.4G WLAN] Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) IEEE 802.11b 1 2412 15.18 6 2437 15.52 11 2462 15.36 IEEE 802.11g 1 2412 14.75 6 2437 14.6 11 2462 14.05 IEEE 802.11n HT20 1 2412 13.74 6 2437 13.16 11 2462 13.23 Page 4 of 5 FCC ID: 2ANPT-96423 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, S…
Text truncated - open the document above for the full version.
AntennaSpecification Manufacture:TUYA ProductName:CBUAntenna AntennaType:PCB TestDate:2020.11.24 Testedby:YinhuaZhang Approvedby:Licco Content 1.GeneralDescription.................................................................................1 2.TestConfigurations...................................................................................2 2.1TestEnvironment............................................................................2 2.2TestEquipment...............................................................................2 2.3TestPrinciple...................................................................................2 3.TestResults..............................................................................................3 3.1GainandEfficiency..........................................................................3 3.2RadiationPattern............................................................................4 4.AntennaDimensions................................................................................5 5.EUTPhoto................................................................................................5 6.TestSetupPhoto......................................................................................6 1 1.GeneralDescription ManufacturerHangzhouTuyaInformationTechnologyCo.,Ltd Address Room701,Building3,MoreCenter,No.87GuDunRoad, Hangzhou,Zhejiang,China TestLocation Room106,Building3,LetongSciencePark,No.500, QiuyiRoad,BinjiangDistrict,Hangzhou ProductNameCBUAntenna Productmodel CBU AntennaType PCBAntenna TestItems Gain;Efficiency;RadiationPattern TestFrequency 2400-2500MHz TestStandard ANSI/IEEEStd149-1979 2 2.TestConfigurations 2.1TestEnvironment Temperature(°C)25 Humidity(%RH)60 AtmosphericPressure(kPa)100.5 2.2TestEquipment TestSystemTEM24Multi-probeMicrowaveChamber TestInstrumentAgilentE5071B 2.3TestPrinciple 3 3.TestResults 3.1GainandEfficiency Frequency(MHz)PeakGain(dBi)Efficiency(%) 2400 2.1132.36 2410 2.1832.3 2420 2.2132.1 2430 2.0632.4 2440 2.0732.9 2450 1.9130.9 2460 2.0430.8 2470 2.0930.7 2480 1.9831.6 2490 1.9130.6 2500 1.0330.5 4 3.2RadiationPattern Phi02D Phi902D Theta902D 5 2440MHz3D 4.AntennaDimensions 5.EUTPhoto 6 6.TestSetupPhoto
Page 1 of 29 FCC ID: 2ANPT-96423 Report No.: LCSA05294095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BT (Conducted Measurement) Product Name: Zeus Oasis Plus Fountain Test Model: 96423 Environmental Conditions Temperature: 23.8 C Relative Humidity: 52.1% ATM Pressure: 100.0 kPa Test Engineer: Paddi Chen Supervised by: Nick Peng Page 2 of 29 FCC ID: 2ANPT-96423 Report No.: LCSA05294095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -20dB Bandwidth Condition Mode Frequency (MHz) Antenna -20 dB Bandwidth (MHz) Limit -20 dB Bandwidth (MHz) Verdict NVNT 1-DH5 2402 Ant1 0.959 N/A Pass NVNT 1-DH5 2441 Ant1 0.958 N/A Pass NVNT 1-DH5 2480 Ant1 1.007 N/A Pass Page 3 of 29 FCC ID: 2ANPT-96423 Report No.: LCSA05294095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -20dB Bandwidth NVNT 1-DH5 2402MHz Ant1 -20dB Bandwidth NVNT 1-DH5 2441MHz Ant1 Page 4 of 29 FCC ID: 2ANPT-96423 Report No.: LCSA05294095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 1-DH5 2480MHz Ant1 Page 5 of 29 FCC ID: 2ANPT-96423 Report No.: LCSA05294095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Duty Factor (dB) Total Power (dBm) Limit (dBm) Verdict NVNT 1-DH5 2402 Ant1 -0.83 0 -0.83 21 Pass NVNT 1-DH5 2441 Ant1 -0.22 0 -0.22 21 Pass NVNT 1-DH5 2480 Ant1 0.03 0 0.03 21 Pass Page 6 of 29 FCC ID: 2ANPT-96423 Report No.: LCSA05294095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT 1-DH5 2402MHz Ant1 Power NVNT 1-DH5 2441MHz Ant1 Page 7 of 29 FCC ID: 2ANPT-96423 Report No.: LCSA05294095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT 1-DH5 2480MHz Ant1 Page 8 of 29 FCC ID: 2ANPT-96423 Report No.: LCSA05294095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Carrier Frequencies Separation Condition Mode Antenna Hopping Freq1 (MHz) Hopping Freq2 (MHz) HFS (MHz) Limit (MHz) Verdict NVNT 1-DH5 Ant1 2402.146 2403.002 0.856 0.639 Pass Page 9 of 29 FCC ID: 2ANPT-96423 Report No.: LCSA05294095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs CFS NVNT 1-DH5 2402MHz Ant1 Page 10 of 29 FCC ID: 2ANPT-96423 Report No.: LCSA05294095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.4 Dwell Time Condition Mode Frequency (MHz) Antenna Pulse Time (ms) Total Dwell Time (ms) Burst Count Period Time (ms) Limit (ms) Verdict NVNT 1-DH5 2402 Ant1 2.881 305.386 106 31600 400 Pass Page 11 of 29 FCC ID: 2ANPT-96423 Report No.: LCSA05294095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Dwell NVNT 1-DH5 2402MHz Ant1 One Burst Dwell NVNT 1-DH5 2402MHz Ant1 Accumulated Page 12 of 29 FCC ID: 2ANPT-96423 Report No.: LCSA05294095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.5 Number of Hopping Channel Condition Mode Antenna Hopping Number Limit Verdict NVNT 1-DH5 Ant1 79 15 Pass Page 13 of 29 FCC ID: 2ANPT-96423 Report No.: LCSA05294095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Sh…
Text truncated - open the document above for the full version.
Page 1 of 37 FCC ID: 2ANPT-96423 Report No.: LCSA05294095EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FOR Rolf C. Hagen Inc. Zeus Oasis Plus Fountain Test Model: 96423 Prepared for : Rolf C. Hagen Inc. Address : 20500 Trans Canada Hwy, Baie d'Urfe, QC H9X 0A2, Canada Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : May 29, 2024 Number of tested samples : 2 Sample No. : A240419070-1, A24041907…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.00 mW |

Zeus Oasis Plus Fountain
Equipment Class
DTS - Digital Transmission System
Microtope LED Strip
Equipment Class
DTS - Digital Transmission System
Microtope LED Strip
Equipment Class
DTS - Digital Transmission System
Microtope LED Strip
Equipment Class
DTS - Digital Transmission System
Aquarium Luminaire
Equipment Class
DTS - Digital Transmission System