FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Rolf C. Hagen Inc/
  3. 2ANPT-PT4251

2ANPT-PT4251Microtope LED Strip

Rolf C. Hagen Inc
Microtope LED Strip - FCC ID 2ANPT-PT4251 - Rolf C. Hagen Inc
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 15, 2021
Application Purpose
Original Equipment
Date of Application
Mar 15, 2021
Equipment Note
Microtope LED Strip
Frequency Range
2412.00000000 - 2462.00000000
Company
Rolf C. Hagen Inc
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Microtope LED Strip- English Tropical LED Light Tropical High output LED Light 24W call-out1: Wifi-controlled call-out2: My Exo Terra APP call-out3: With UVA emitting LED’s call-out4: Programmable 24-hour Light Cycle with Sunrise and Sunset call-out5: Monitor and control your lights from anywhere in the World! call-out6: IP54 rated waterproof housing Ideal light source for bio-active planted terrariums HTE LEDs for extreme high light output and enhanced penetration Stimulates live plant and moss growth Improves the animal’s perception of its environment Programmable 24-hour Light Cycle with Sunrise and Sunset Seven LED color types, including UVA and 12000K bright white LED’s Fully customisable light spectrum through individually adjustable LEDs Can be operated manually or Wifi-controlled via the easy-to-use My Exo Terra App Monitor and control your lights from anywhere in the World Touch switch with dimming function Waterproof housing rated IP54 for use in humid environments The Wifi-controlled Exo Terra Tropical LED Light is an ideal light source for bio-active planted terrariums. The Tropical LED Light consists of 7 different band wave High Thermal Efficiency LEDs, including UVA and 12000K bright white LEDs, for extreme high light output and enhanced penetration. Its high visible light levels, in the correct spectrum, contribute to the physiological wellbeing of your reptiles, amphibians and invertebrates and lets them experience and perceive the colors in their environment more naturally. The UVA LEDs also contribute to the animal’s overall wellbeing and stimulate appetite, activity and reproductive behavior. The high light intensity and enhanced penetration ensures that the light reaches all layers of vegetation, even the bottom layer, resulting in sustained lush plant growth. Orchids, Bromeliads, Tillandsias (air plants), carnivorous plants, mosses and lichen all thrive under the Exo Terra Tropical LED Light’s strong Photosynthetic Active Radiation. The Wifi-controlled Tropical LED Light can be operated both manually or via the My Exo Terra app on your mobile device. The easy-to-use My Exo Terra App allows you to fully customise the light spectrum, sunrise & sunset and monitor and adjust these, according to the needs of the animals and plants housed in your terrarium, from anywhere in the world via your smartphone. Replicate light spectrums of specific seasons and unique climates to stimulate appetite and breeding behavior of your animals, enhance bud development and flowering in your plants, etc... . User Manual The Exo TerraTropicalLED Lightconnectsto your2.4g wirelessnetworkwithoutthe need for an additionalhub. The My Exo TerraApp lets you monitor,controland programyourExo Terrasmartterrarium devicesvia yourAndroidor iOS device.It allowsyou to adjustyourlights,temperatures, humidifiers,water-levels,camera’s (andmore... ) for multipleterrariumsor habitats,creating naturalenvironmentsand set the rightconditionswitha tap on yoursmartphone.You can evenuse it to monitor& controlyourhabitatsremotelyfromanywherein the worldas long as the deviceis connectedto a 2.4g wirelessnetwork.Downloadthe FREEMy Exo TerraApp on yourmobiledeviceand connectyourExo Terrasmartdevicesto programand controlthe environmentin yourterrariums. For instance;at dawnyou can set the My Exo TerraApp to simulatesunrise,turn on yourUV lightsat a certaintimeand higheryourtemperatureoverthe courseof the day. At dusk,you can reversethe conditionsby reducingthe temperature,turn off the UV lightsand simulate sunset.If you havea wifi controlledMonsoonPRO hookedup, you can set a sprayprogram at varioustimeswith variousdurations.You can evenimplementa seasonalMonsoon settingthat will replicatethe variousrainyseasonsduringthe year.By usingthe wifi controlledHumidifier(PRO?)you can regulatea dailyhumidityfluctuationas well as a seasonalfluctuation,similarto the humidityyouranimalsand plantsexperiencein their environment. The TropicalLED Lightfeatures7 uniquebandwavesfor optimalspectrumresults: 390nm 400nm 460nm 630nm 730nm 4000K 12000K The TropicalLED Light24Wgenerates1480lmwitha max of 29730Lux and a PAR of 530! The TropicalLED Light33Wgenerates2150lmwitha max of 31700Lux and a PAR of 585! The TropicalLED Light49Wgenerates2960lmwitha max of 32100Lux and a PAR of 625! A specificallyengineeredaluminumshelloffersincreasedheattransferresultingin a longer LED lifetimeof 50.000hours The TropicalLED Light24W(PT4251)convenientlyfits on all NaturalTerrariumSmall versions. The TropicalLED Light33W(PT4252)convenientlyfits on all NaturalTerrariumMedium versions.By usingthe (included)spacers,the TropicalLED Light32W(PT4252)also fits on 2 adjacentNaturalTerrariumMiniversions. The TropicalLED Light49W(PT4253)convenientlyfits on all NaturalTerrariumLarge versions.By usingthe (included)spacers,the TropicalLED Light48Walso fits on 2 adjacent NaturalTerrariumSmallversions,1 TerrariumMediumand 1 adjacentNaturalTerrarium Smallor 3 adjacentNaturalTerrariumMiniversions. QR-code:TropicalLED Light QR-codeMy Exo TerraApp Pet care fixturefor use withReptiles,Amphibiansand Invertebratesonly! PT4251– TropicalHighoutputLED Light24W/ 45cm– 18" / 126 LEDs PT4252– TropicalHighoutputLED Light33W/ 60cm– 24" / 159 LEDs PT4253– TropicalHighoutputLED Light49W/ 90cm– 36" / 222 LEDs Touchswitchoperation:ON/DIM(touch-and-hold)/BLUE/OFF IMPORTANTSAFETYINSTRUCTIONS WARNING:To guardagainstinjury,basicprecautionsshouldbe observed,includingthe following: READANDFOLLOWALL SAFETYINSTRUCTIONSand all the importantnoticeson the productbeforeusing.Failureto do so may resultin personalinjuryor damageto the product. DANGER– To avoidpossibleelectricalshock,specialcare shouldbe takensincewateris/may be employedin the use of this product.For eachof the followingsituations,do not attempt repairsyourself,returnthe productto an authorizedservicefacilityfor serviceif it is still underwarrantyor discardthe product: 1. Carefullyexaminethe applianceafterinstallation. 2. The app…

Text truncated - open the document above for the full version.

Cover Letter(s)

RolfC.HagenInc AgentAuthorization Company:RolfC.HagenInc Address:20500TransCanadaHwyBaie-d'Urfe,Quebec,H9X0A2,Canada ProductName:MicrotopeLEDStrip TradeMark:ExoTerra ModelNumber(s):PT4251 FCCID:2ANPT-PT4251 WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2021-03-10 Name:RobertReid Title:AquaticBrandsManager Company:RolfC.HagenInc

Cover Letter(s)

RolfC.HagenInc OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2021-03-10 Subject;RequestforConfidentiality FCCID:2ANPT-PT4251 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:RobertReid Title:AquaticBrandsManager

External Photos

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251 EXTERIORPHOTOGRAPHS Fig.1 Fig.2 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251 Fig.3 Fig.4 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251 Fig.5 Fig.6 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251 Fig.7

ID Label/Location Info

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of1 LabelandLocation Size:L:1.4.0cm*W:2.5cm LabelLocation

Internal Photos

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251 INTERIORPHOTOGRAPHS Fig.1 Fig.2 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251 Fig.3 Fig.4 2.4GWIFIAntenna SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251 Fig.5

RF Exposure Info

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of 4 FCCRFExposureEvaluation 1.ProductInformation FCCID2ANPT-PT4251 Productname MicrotopeLEDStrip Modelnumber PT4251 Powersupply ForACAdapterModel:S024AMU2400100 Input:100-240V~,50/60Hz,600mA Output:DC24V,1A ModulationType IEEE802.11b:DSSS(CCK,DQPSK,DBPSK) IEEE802.11g:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) AntennaType PCBAntenna AntennaGain 1.0dBi(Max.) Hardwareversion 1.0 Softwareversion 1.0 FCCOperationfrequency 2412–2462MHz Exposurecategory Generalpopulation/uncontrolledenvironment EUTType ProductionUnit DeviceType FixedDevices 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensuresthatthepublic isnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobiledevicewhereby adistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelowRFPermissibleExposure limitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesumofthe MPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthecalculated/estimated, numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPEratioofeachantennais determinedattheminimumtestseparationdistancerequiredbytheoperatingconfigurationsandexposureconditionsof thehostdevice,accordingtotheratiooffieldstrengthsorpowerdensitytoMPElimit,atthetestfrequency.Eitherthe maximumpeakorspatiallyaveragedresultsfrommeasurementsornumericalsimulationsmaybeusedtodeterminethe MPEratios.SpatialaveragingdoesnotapplywhenMPEisestimatedusingsimplecalculationsbasedonfar-field plane-waveequivalentconditions.Theantennainstallationandoperatingrequirementsforthehostdevicemustmeetthe minimumtestseparationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneoustransmissionoperations, tosatisfycompliance. SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 2 of 4 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–2019:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoElectric,Magnetic,and ElectromagneticFields,0Hzto300GHz. FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRFExposure ProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4πR² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation ArtemisAntennacanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal Identification Antennatypeand antennanumber Operatefrequencyband Maximum antennagain Note AntennaPCBAntenna2412MHz-2462MHz1.0dBi2.4GWIFIAntenna SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 3 of 4 6.ConductedPower ModeChannelFrequency(MHz) PeakConducted OutputPower(dBm) 11B 1241217.90 6243715.94 11246217.86 11G 1241222.68 6243720.65 11246222.28 11N20SISO 1241222.72 6243720.70 11246222.24 7.ManufacturingTolerance 11B(Peak) ChannelChannel1Channel6Channel11 Target(dBm) 17.015.017.0 Tolerance±(dB) 1.01.01.0 11G(Peak) ChannelChannel1Channel6Channel11 Target(dBm) 22.020.022.0 Tolerance±(dB)1.01.01.0 11N20SISO(Peak) ChannelChannel1Channel6Channel11 Target(dBm) 22.020.022.0 Tolerance±(dB)1.01.01.0 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 4 of 4 8.MeasurementResults 8.1StandaloneMPE AsdeclaredbytheApplicant,theEUTisawirelessdeviceusedinafixapplication,atleast20cmfromanybodypartof theuserornearbypersons;fromthemaximumEUTRFoutputpower,theminimumseparationdistance,r=20cm,as wellasthegainoftheusedantennarefertoantennainformation,theRFpowerdensitycanbeobtained. [Antenna] Band/Mode RFoutputpower AntennaGain (dBi) MPE (mW/cm2) MPE Limits (mW/cm2) dBmmW IEEE802.11b18.0 63.0957 1.0 0.0158 1.0000 IEEE802.11g23.0 199.5262 1.0 0.0500 1.0000 IEEE802.11nHT2023.0 199.5262 1.0 0.0500 1.0000 Remark: 1.Outputpowerincludingtune-uptolerance; 2.MPEevaluatedistanceis20cmfromusermanualprovidebymanufacturer; 8.2SimultaneousTransmissionMPE 9.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1091fortheuncontrolledRFExposureofmobile device. .......................THEENDOFREPORT.........................

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251 Report No.: LCS210111039AEA Page 1 of 35 Appendix A RF Test Data for 2.4G WIFI (Conducted Measurement) Product Name: Microtope LED Strip Trade Mark: Exo Terra Test Model: PT4251 Environmental Conditions Temperature: 24.6  C Relative Humidity:54.1% ATM Pressure:100.0 kPa Test Engineer:Carl Fu Supervised by:Li Huan A.1 Duty Cycle Test ModeTest ChannelAntDuty Cycle[%]Verdict 11B2437Ant188.82PASS 11G2437Ant186.58PASS 11N20SISO2437Ant185.67PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 2 of 35 Duty Cycle_11B_2437_Ant1 Duty Cycle_11G_2437_Ant1 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 3 of 35 Duty Cycle_11N20SISO_2437_Ant1 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 4 of 35 A.2 Maximum Conducted Output Power ModeChannelMeas.Level [dBm]Limit [dBm]Verdict 11B LCH17.9030PASS MCH15.9430PASS HCH17.8630PASS 11G LCH22.6830PASS MCH20.6530PASS HCH22.2830PASS 11N20SISO LCH22.7230PASS MCH20.7030PASS HCH22.2430PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 5 of 35 A.3 Maximum Power Spectral Density ModeChannelMeas.Level [dBm/3KHz]Limit [dBm/3KHz]Verdict 11B LCH-7.4708PASS MCH-10.2548PASS HCH-8.5278PASS 11G LCH-9.7508PASS MCH-13.5548PASS HCH-12.1578PASS 11N20SISO LCH-10.9728PASS MCH-14.0458PASS HCH-12.3678PASS Test Graphs 11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 6 of 35 11B/MCH 11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 7 of 35 11G/LCH 11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 8 of 35 11G/HCH 11N20SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 9 of 35 11N20SISO/MCH 11N20SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 10 of 35 A.4 6dB Bandwidth ModeChannel6dB Bandwidth [MHz]Limit [MHz]Verdict 11B LCH8.113 ≥0.5 PASS MCH8.560 ≥0.5 PASS HCH8.561 ≥0.5 PASS 11G LCH16.35 ≥0.5 PASS MCH16.36 ≥0.5 PASS HCH16.34 ≥0.5 PASS 11N20SISO LCH17.31 ≥0.5 PASS MCH17.56 ≥0.5 PASS HCH17.32 ≥0.5 PASS Test Graphs 11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 11 of 35 11B/MCH 11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 12 of 35 11G/LCH 11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 13 of 35 11G/HCH 11N20SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 14 of 35 11N20SISO/MCH 11N20SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 15 of 35 A.5 RF Conducted Spurious Emissions ModeChannelPref [dBm]Max. Level [dBm]Limit [dBm] Verdic t 11B LCH7.026-37.498-12.974PASS MCH5.138-38.028-14.862PASS HCH6.889-37.247-13.111PASS 11G LCH3.955-37.716-16.045PASS MCH1.874-37.919-18.126PASS HCH3.504-37.940-16.496PASS 11N20 SISO LCH4.027-38.216-15.973PASS MCH1.978-38.532-18.022PASS HCH3.692-37.445-16.308PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 16 of 35 11B_LCH_Graphs Pref/11B/LCH Puw/11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 17 of 35 11B_MCH_Graphs Pref/11B/MCH Puw/11B/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 18 of 35 11B_HCH_Graphs Pref/11B/HCH Puw/11B/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 19 of 35 11G_LCH_Graphs Pref/11G/LCH Puw/11G/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 20 of 35 11G_MCH_Graphs Pref/11G/MCH Puw/11G/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 21 of 35 11G_HCH_Graphs Pref/11G/HCH Puw/11G/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 22 of 35 11N20SISO_LCH_Graphs Pref/11N20SIS O/LCH Puw/11N20 SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 23 of 35 11N20SISO_MCH_Graphs Pref/11N20 SISO/MCH Puw/11N20 SISO/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 24 of 35 11N20SISO_HCH_Graphs Pref/11N20 SISO/HCH Puw/11N20 SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 25 of 35 A.6 Band-edge for RF Conducted Emissions ModeChannelCarrier Power[dBm] Max.Spurious Level [dBm] Limit [dBm]Verdict 11B LCH6.888-49.520-13.11PASS HCH6.874-48.489-13.13PASS 11G LCH4.033-43.120-15.97PASS HCH3.513-40.301-16.49PASS 11N20SISO LCH4.097-42.233-15.90PASS HCH3.624-38.763-16.38PASS Test Graphs 11B/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 26 of 35 11B/HCH 11G/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 27 of 35 11G/HCH 11N20SISO/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 28 of 35 11N20SISO/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.FCC ID: 2ANPT-PT4251Report No.: LCS210111039AEA Page 29 of 35 A.7 Restrict-band band-edge measurements Test Mode Test Channel AntFreq. Power [dBm] Gain Ground Factor E [dBuV/m] Detector Limit [dBu V/m] Verdict 11B 2412Ant12310.0-42.582.0054.65PEAK74PASS 2412Ant12310.0-53.362.0043.87AV54PASS 2412Ant12390.0-40.922.0056.31PEAK74PASS 2412Ant1239…

Text truncated - open the document above for the full version.

Test Report

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251ReportNo.:LCS210111039AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of 37 FCCTESTREPORT For RolfC.HagenInc MicrotopeLEDStrip TestModel:PT4251 Preparedfor:RolfC.HagenInc Address:20500TransCanadaHwyBaie-d'Urfe,Quebec,H9X0A2,Canada Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:January13,2021 Numberoftestedsamples:2 Samplenumber:210111039A-1,210111039A-2 Serialnumber:Prototype DateofTest:January13,2021~January19,2021 DateofReport:January22,2021 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251ReportNo.:LCS210111039AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 2 of 37 FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo..........................:LCS210111039AEA DateofIssue.........................................:January22,2021 TestingLaboratoryName..................:ShenzhenLCSComplianceTestingLaboratoryLtd. Address.................................................:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure.................:FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–ˇ Otherstandardtestingmethodâ–ˇ Applicant’sName................................:RolfC.HagenInc Address.................................................:20500TransCanadaHwyBaie-d'Urfe,Quebec,H9X0A2,Canada TestSpecification Standard................................................:FCCCFR47PART15C(15.247) TestReportFormNo..........................:LCSEMC-1.0 TRFOriginator.....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF...........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongastheShenzhenLCS ComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthematerial.ShenzhenLCS ComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnotassumeliabilityfordamagesresulting fromthereader'sinterpretationofthereproducedmaterialduetoitsplacementandcontext. EUTDescription.................................:MicrotopeLEDStrip TradeMark...........................................:ExoTerra TestModel............................................:PT4251 Ratings..................................................: ForACAdapterModel:S024AMU2400100 Input:100-240V~,50/60Hz,600mA Output:DC24V,1A Result....................................................:Positive Compiledby:Supervisedby:Approvedby: JackLiu/FileadministratorsJinWang/TechniqueprincipalGavinLiang/Manager SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251ReportNo.:LCS210111039AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of37 FCC--TESTREPORT EUT.........................................:MicrotopeLEDStrip TestModel...............................:PT4251 Applicant...............................:RolfC.HagenInc Address..................................:20500TransCanadaHwyBaie-d'Urfe,Quebec,H9X0A2,Canada Telephone...............................:/ Fax..........................................:/ Manufacturer........................:ZhengzhouLeDinProLightingCo.,Ltd. Address...................................:No.27,FengLinRoad,HighTechnologyDevelopmentZone,Zhengzhou, Henan,China. Telephone...............................:/ Fax..........................................:/ Factory...................................:/ Address...................................:/ Telephone...............................:/ Fax..........................................:/ TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCS210111039AEA January22,2021 Dateofissue SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251ReportNo.:LCS210111039AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page4of37 RevisionHistory RevisionIssueDateRevisionsRevisedBy 000 January22,2021 InitialIssueGavinLiang SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251ReportNo.:LCS210111039AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page5of37 TABLEOFCONTENTS 1.GENERALINFORMATION....................................................................................................................................6 1.1.DESCRIPTIONOFDEVICE(EUT)............................................................................................................................6 1.2.HOSTSYSTEMCONFIGURATIONLISTANDDETAILS.............................................................................................7 1.3.EXTERNALI/OCABLE...........................................................................................................................................7 1.4.DESCRIPTIONOFTESTFACILITY...........................................................................................................................7 1.5.STATEMENTOFTHEMEASUREMENTUNCERTAINTY.............................................................................................7 1.6.MEASUREMENTUNCERTAINTY..............................................................................................................................8 1.7.DESCRIPTIONOFTESTMODES...............................................................................................................................8 …

Text truncated - open the document above for the full version.

Test Setup Photos

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251 _______________________________________________________________________________________________ 7.TESTSETUPPHOTOGRAPHS PhotoofRadiatedEmissionsMeasurement Below1GHz Above1GHz SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2ANPT-PT4251 _______________________________________________________________________________________________ PowerLineConductedEmission

Contact Information

Applicant

Robert Reid(Aquatic Brands Manager)
[email protected]+1 514 4570914Fax: +1 514 4578246

Technical Contact

Rolf C. Hagen Inc
[email protected]

Canada

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz187.10 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Rolf C. Hagen Inc

Zeus Oasis Plus Fountain - FCC ID 2ANPT-96422 - Rolf C. Hagen Inc
2ANPT-96422

Zeus Oasis Plus Fountain

Jul 07, 2024

Equipment Class

DTS - Digital Transmission System
Zeus Oasis Plus Fountain - FCC ID 2ANPT-96423 - Rolf C. Hagen Inc
2ANPT-96423

Zeus Oasis Plus Fountain

Jul 07, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Microtope LED Strip - FCC ID 2ANPT-PT4252 - Rolf C. Hagen Inc
2ANPT-PT4252

Microtope LED Strip

Mar 15, 2021

Equipment Class

DTS - Digital Transmission System
Microtope LED Strip - FCC ID 2ANPT-PT4253 - Rolf C. Hagen Inc
2ANPT-PT4253

Microtope LED Strip

Mar 15, 2021

Equipment Class

DTS - Digital Transmission System
Aquarium Luminaire - FCC ID 2ANPT-A13294 - Rolf C. Hagen Inc
2ANPT-A13294

Aquarium Luminaire

Sep 14, 2020

Equipment Class

DTS - Digital Transmission System