2AO8RNI-1921Vigil 3

Netvue Technologies Co., Ltd.
Vigil 3 - FCC ID 2AO8RNI-1921 - Netvue Technologies Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 23, 2023
Application Purpose
Original Equipment
Date of Application
Mar 23, 2023
Equipment Note
Vigil 3
Frequency Range
2412.00000000 - 2462.00000000
Company
Netvue Technologies Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Vigil 3 Quick Guide Your property guardian at day and night Model: NI-1921 EN DE FR ES IT Warning NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC ID 2AO8RNI-1921 CE RED This product can be used across EU member states. CE RED Das Produkt kann in allen EU-Mitgliedstaaten verwendet werden. CE RED Cet appareil peut être utilisé dans les pays de l’Union Européenne. Toujours disponible pour vous fournir des aides supplémentaires. CE RED Este producto puede ser usado en todos los estados miembros de la UE. No dude en contactarnos para ayudas adicionales. CE RED Questo prodotto può essere utilizzato in tutti gli stati membri dell’UE. Non esitare a contattarci per ulteriore aiuto. Catalogue 1. What’s In The Box 2. Camera Structure 3. Insert Micro SD Card 4. Read Before Installing 5. Set Up With Netvue App 6. Vigil 3 Camera Installation 7. Netvue Protect Plan P. 1-2 P. 3 P. 4-6 P. 7 P. 12 P. 13-22 P. 23-24 P. 1-2 P. 3 P. 4-6 P. 8 P. 12 P. 13-22 P. 23-24 1. Was ist in der Box 2. Kamerastruktur 3. Legen Sie die Micro SD-Karte ein 4. Lesen Sie vor der Installation 5. Mit Netvue App einrichten 6. Installation der Vigil-Kamera 7. Netvue Protect Plan P. 1-2 P. 3 P. 4-6 P. 9 P. 12 P. 13-22 P. 23-24 P. 1-2 P. 3 P. 4-6 P. 10 P. 12 P. 13-22 P. 23-24 1. Contenu de la boîte 2. Structure de la caméra 3. Insérez la carte Micro SD 4. À lire avant l'installation 5. Configurer avec l'application Netvue 6. Installation de Vigil Camera 7. Plan de protection Netvue 1. Qué hay en la caja 2. Estructura de la cámara 3. Inserte la tarjeta Micro SD 4. Leer antes de instalar 5. Configurar con la aplicación Netvue 6. Instalación de la cámara Vigil 7. Plan de protección de Netvue P. 1-2 P. 3 P. 4-6 P. 11 P. 12 P. 13-22 P. 23-24 1. Cosa c'è nella scatola 2. Struttura della telecamera 3. Inserire la scheda Micro SD 4. Leggere prima di installare 5. Configurare con l'app Netvue 6. Installazione della telecamera di Vigil 7. Piano Netvue Protect What’s In The Box X 3X 3 Mounting Screws Befestigungsschrauben Vis de montage Tornillos de montaje Viti di montaggio Anchors Anker Ancres Anclas Ancore Drilling Template Platzkennzeichnung Etiquette de localisation Pegamento de ubicación Etichetta di posizione Power Adapter Netzteil Adaptateur d'alimentation Adaptador de corriente Adattatore di Alimentazione 1 Quick Guide Kurzanleitung Guide rapide Guía rápida Guida veloce Vigil 3 Camera 2 Vigil 3 Quick Guide Your property guardian at day and night EN DE FR ES IT Camera Structure Lens Linse Lentille Lente Lente Reset Zurücksetzen Réinitialiser Ripristina Reiniciar RESET Micro SD Card Slot Micro SD-Kartensteckplatz Emplacement pour carte micro SD Ranura para tarjeta micro SD Slot per scheda micro SD Speaker Lautsprecher Orateur Orador Altoparlante Light Sensor Lichtsensor Capteur de lumière Sensor de luz Sensore di Luce Antenna Antenne Antenne Antena Antenna Power Port Stromanschluss Port d'alimentation Puerto de alimentación Porta di alimentazione 3 Insert Micro SD Card The Vigil 3 has a built-in card slot that supports Micro SD cards up to 128GB. After inserting the memory card, the camera will automatically start recording video and store it on the memory card. You can view these videos in the Replay page by clicking the Replay button in the Home page. Step 1: Open the bottom silicone plug. Step 2: Insert the Micro SD card. Make sure to plug it in the right direction. Step 3: Finally, close the silicone plug. Das Vigil 3 verfügt über einen integrierten Kartensteckplatz, der Micro-SD-Karten mit bis zu 128 GB unterstützt. Nach dem Einlegen der Speicherkarte beginnt die Kamera automatisch mit der Videoaufzeichnung und speichert sie auf der Speicherkarte. Sie können diese Videos auf der Replay-Seite ansehen, indem Sie auf der Startseite auf die Replay-Schalt- fläche klicken. Schritt 1: Öffnen Sie den unteren Silikonstopfen. Schritt 2: Legen Sie die Micro-SD-Karte ein. Achten Sie darauf, es in die richtige Richtung zu stecken. Schritt 3: Schließen Sie abschließend den Silikonstopfen. 4 Le Vigil 3 dispose d'un emplacement pour carte intégré qui prend en charge les cartes Micro SD jusqu'à 128 Go. Après avoir inséré la carte mémoire, l'appareil photo démarre automatiquement l'enregistrement vidéo et le stocke sur la carte mémoire. Vous pouvez visionner ces vidéos sur la page Replay en cliquant sur le bouton Replay de la page d'accueil. Étape 1 : Ouvrez le bouchon inférieur en silicone. Étape 2 : Insérez la carte Micro SD. Assurez-vous de le brancher dans le bon sens. Étape 3 : Enfin, fermez le bouchon en silicone. El Vigil 3 tiene una ranura para tarjetas incorporada que admite tarjetas Micro SD de hasta 128 GB. Después de insertar la tarjeta de memoria, la cámara comenzará a grabar video automáticamente y lo almacenará en la tarjeta de memoria. Puede ver estos videos en la página Reproduc…

Text truncated - open the document above for the full version.

Attestation Statements

NetvueTechnologiesCo.,Ltd. 2.911(d)(5)(i)EquipmentTypeAttestationv1.2 Section2.911(d)(5)(i)Certification–EquipmentType Companyname:NetvueTechnologiesCo.,Ltd. Address:RoomA501-502,AcademyofAerospaceTechnology,10KejinanRoad,NanshanDistrict, Shenzhen,China,518057 ProductName:Vigil3 FCCID:2AO8RNI-1921 Model(s):NI-1921,NI-1920,NI-1922,NI-1923,NI-1924,NI-1925,NI-1926,NI-1927,NI-1928,NI-1929 2.911(d)(5)(i)EquipmentType We,[NetvueTechnologiesCo.,Ltd.](“theapplicant”)certifythattheequipmentforwhich authorizationissoughtthroughcertificationisnot: Prohibitedfromreceivinganequipmentauthorizationpursuantto§2.903;oftheFCCrules. Identifiedasanequipmenttypeinthe“CoveredList” NOTE1 Yourssincerely, Name:StoneFengDate:2023.03.14 TitleandCompanyname:Manager/NetvueTechnologiesCo.,Ltd. NOTE1 “CoveredList ” ;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

NetvueTechnologiesCo.,Ltd. 2.911(d)(5)(ii)ApplicantAttestationv1.3 Section2.911(d)(5)(ii)Certification–Applicant(CoveredList) Companyname:NetvueTechnologiesCo.,Ltd. Address:RoomA501-502,AcademyofAerospaceTechnology,10KejinanRoad, NanshanDistrict,Shenzhen,China,518057 ProductName:Vigil3 FCCID:2AO8RNI-1921 Model(s):NI-1921,NI-1920,NI-1922,NI-1923,NI-1924,NI-1925,NI-1926,NI-1927,NI-1928,NI-1929 2.911(d)(5)(ii)Applicantfiling We,[NetvueTechnologiesCo.,Ltd.](“theapplicant”)certifythat,asofthedateofthefilingofthe application,theapplicantisisnotidentified NOTE1 onthe“CoveredList” NOTE2 ,establishedpursuant to§1.50002ofthischapter,asanentityproducingcoveredcommunicationsequipment. Yourssincerely, Name:StoneFengDate:2023.03.14 TitleandCompanyname:Manager/NetvueTechnologiesCo.,Ltd. NOTE1 Deleteoptionnotapplicabletothisapplication. NOTE2 “CoveredList ” ;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

NetvueTechnologiesCo.,Ltd. 2.911(d)(7)USAAgentv1.3 Section2.911(d)(7)USAAgentforServiceofProcess Companyname:NetvueTechnologiesCo.,Ltd. Address:RoomA501-502,AcademyofAerospaceTechnology,10KejinanRoad, NanshanDistrict,Shenzhen,China,518057 ProductName:Vigil3 FCCID:2AO8RNI-1921 Model(s):NI-1921,NI-1920,NI-1922,NI-1923,NI-1924,NI-1925,NI-1926,NI-1927, NI-1928,NI-1929 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[NetvueTechnologiesCo.,Ltd.](“theapplicant”)designate[NETVUE,INC] NOTE1 forthepurposeofacceptingserviceofprocessonbehalfoftheapplicant. Applicantconsent:WeAcknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminated allmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolving theequipment,whicheverislater. Agentobligation:WeAcknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,ortheconclusionofanyCommission-relatedadministrativeorjudicial proceedinginvolvingtheequipment,whicheverislater. USAAgent Companyname:NETVUE,INC Address:240WWHITTIERBLVDSTEALA HABRA,CA90631 FRN:0033559915 ContactName:QiangFeng TelephoneNo: +1-626-5380386 Applicant Companyname:NetvueTechnologies Co.,Ltd. Address:RoomA501-502,Academyof AerospaceTechnology,10KejinanRoad, NanshanDistrict,Shenzhen,China, 518057 FCCGranteeCode:2AO8R ContactName:StoneFeng TelephoneNo:+86-0755-86227808 NetvueTechnologiesCo.,Ltd. 2.911(d)(7)USAAgentv1.3 Email:[email protected]:[email protected] Signature: Title:Manager Signature: Title:Manager Date:2023.03.14Date:2023.03.14 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the

Cover Letter(s)

NetvueTechnologiesCo.,Ltd. AgentAuthorization Company:NetvueTechnologiesCo.,Ltd. Address:RoomA501-502,AcademyofAerospaceTechnology,10KejinanRoad, NanshanDistrict,Shenzhen,China,518057 ProductName:Vigil3 ModelNumber(s):NI-1921,NI-1920,NI-1922,NI-1923,NI-1924,NI-1925,NI-1926, NI-1927,NI-1928,NI-1929 ProductDescription:Vigil3 WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2023.03.14 Name:StoneFeng Title:Manager Company:NetvueTechnologiesCo.,Ltd.

Cover Letter(s)

NetvueTechnologiesCo.,Ltd. ModelDifferent Modelname:Vigil3 FCCID:2AO8RNI-1921 Modelnumber:NI-1921,NI-1920,NI-1922,NI-1923,NI-1924,NI-1925,NI-1926,NI-1927, NI-1928,NI-1929 Allmodel’sthefunction,softwareandelectriccircuitarethesame,exceptthemodelnumber. Name:StoneFeng Date:2023-03-14 Title:Manager Signatureofapplicant:

Cover Letter(s)

NetvueTechnologiesCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2023.03.14 Subject;RequestforConfidentiality FCCID:2AO8RNI-1921 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:StoneFeng Title:Manager

External Photos

ExternalPhotos WifiAntenna FalseAntenna

Internal Photos

InternalPhotos

RF Exposure Info

FCC ID:2AO8RNI-1921 RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f = frequency in MHz Friis transmission formula:Pd = (Pout*G)/(4*pi*r 2 ) Where Pd= power density in mW/cm 2 ,Pout= output power to antenna in mW; G= gain of antenna in linear scale,Pi= 3.1416; R= distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. Test Result of RF Exposure Evaluation Modulation Output power to antenna (dBm) Output power to antenna (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 802.11b 18.1365.01300.0279081.0PASS 18.4169.34260.0297671.0PASS 17.8661.09420.0262261.0PASS 802.11g 15.3634.35580.0147481.0PASS 15.7837.84430.0162451.0PASS 15.0231.76870.0136371.0PASS 802.11n20 15.4234.83370.0149531.0PASS 15.8538.45920.0165091.0PASS 15.1132.43400.0139231.0PASS Remark: antenna gain=3.34 dBi

Test Report

DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 1 /9 承认书 APPROVALSHEET 客户名称 CUSTOMERNAME:九安 产品名称 PRODUCTNAME:2.4GW70白色天线L=140mm+端子 客户料号 CUSTOMERP/N: 优比电子料号 YoubiP/N:UB02C140W3D2393AREV:A MANUFACTURER SIGNATURE CUSTOMER SIGNATURE CHECKEDBY: Yongxin.Lu APPROVEDBY:Changxing.Liu DATE:2021/10/11 DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 2 /9 ModificationHistory VersionContentRevisionIssuedbyDate AOriginalversionYongxin.Lu2021-10-11 DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 3 /9 Content ltemDescription 1.--------------------------------------------------------------------ElectricalSpecification 2.---------------------------------------------------------------TestItemsandEquipment 3.---------------------------------------------------------------------------------SParameter 4.------------------------------------------------------------------------EfficiencyandGain 5.---------------------------------------------------------------------------RadiationPattern 6.-----------------------------------------------------------------MechanicalSpecification 7.------------------------------------------------------------------------------------Packaging DongguanYoubiElectronicsCo.,LTDHangzhouYoubige ElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106, BuildingA,XinzhengIndustrialPark, XinfaRoa d,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57 LiuxianRoad,Bao 'an District,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 4 / 9 1. ElectricalSpecification: 2.TestItemsandEquipment CharacteristicsSpecificationsUnit OutlineDimensions13 x105,L140mm Frequency 2400-2500 MHz Impedance50Ω VSWR≤ 1.92 PolarizationLinearPolarization Gain3.34 dBi Efficiency>50 % ConnectorTypeMHF-1-Plug Operatingtemperature-20°C~+50°C StorageTemp-20°C~+ 50°C TestitemsTestequipment S Parameter 1.ReturnLoss 2. VSWR Networkanalyzer (AgilentE5071B) The wholemachineof Passiveparameters 1.Frequency 2.Gain 3.RadiationPattern 1.3D microwavedarkroom (5m *5m *5 m) 2. Networkanalyzer (AgilentE5071B) The wholemachineof Activeparameters 1. TRP 2. TIS 1.3D microwavedarkroom (5m *5m *5 m) 2. Comprehensivetest instrument (CMW500) DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 5 /9 3.SParameter *VoltageStandingWaveRatio(VSWR) ReturnLoss(RL) RL=20*log10[(VSWR+1)/(VSWR-1) 4.EfficiencyandGain Frequency (MHz) 240024502500 Efficiency (%) 68.5569.8272.11 Gain (dBi) 3.143.333.34 Frequency (MHz) ReturnLoss (dB) VSWR 2400-13.041.57 2450-21.761.17 2500-21.141.19 DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 6 /9 5.RadiationPattern 5-1Antenna3DRadiationPattern 2400MHz 2450MHz 2500MHz DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 7 /9 5-2Antenna2DRadiationPattern Phi02D Phi902D Theta902D Vertical Plane Horizontal Plane DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 8 /9 6.MechanicalSpecification: DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 9 /9 7.Packaging

Test Report

ProjectNo.:ZKT-230213L0664E Page 1 of 46 FCCTESTREPORT FCCID:2AO8RNI-1921 ReportNumber...................................:ZKT-2230213L0664E DateofTest.......................................................: Feb.12,2023toFeb.22,2023 Dateofissue.........................................: Feb.22,2023 Totalnumberofpages .......................... 46 TestResult ............................................ : PASS TestingLaboratory............................: ShenzhenZKTTechnologyCo.,Ltd. Address...............................................: 1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrial Avenue,FuhaiStreet,Bao'anDistrict,Shenzhen,China Applicant'sname.............................:NetvueTechnologiesCo.,Ltd. Address...............................................: RoomA501-502,AcademyofAerospaceTechnology,10Kejinan Road,NanshanDistrict,Shenzhen,China,518057 Manufacturer'sname ...................... :NetvueTechnologiesCo.,Ltd. Address...............................................: RoomA501-502,AcademyofAerospaceTechnology,10Kejinan Road,NanshanDistrict,Shenzhen,China,518057 Testspecification: Standard ................................................ : FCCCFRTitle47Part15SubpartCSection15.247 ANSIC63.10:2013 Testprocedure.....................................: / Non-standardtestmethod................:N/A TestReportFormNo. ....................... : TRF-EL-110_V0 TestReportForm(s)Originator ..... : ZKTTesting MasterTRF ........................................ : Dated:2020-01-06 ThisdevicedescribedabovehasbeentestedbyZKT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZKT,thisdocumentmay bealteredorrevisedbyZKT,personalonly,andshallbenotedintherevisionofthedocument. Productname.....................................: Vigil3 Trademark ........................................... : Netvue Model/Typereference.........................: NI-1921 SerialmodelNo...................................:NI-1920,NI-1922,NI-1923,NI-1924,NI-1925,NI-1926,NI-1927, NI-1928,NI-1929 Ratings..................................................: Input:110-240V~50/60Hz Output:DC12V/1A ProjectNo.:ZKT-2302133L0664E Page 2 of 46 Testingprocedureandtestinglocation: TestingLaboratory.......................................:ShenzhenZKTTechnologyCo.,Ltd. Address............................................................:1/F,No.101,BuildingB,No.6,TangweiCommunity IndustrialAvenue,FuhaiStreet,Bao'anDistrict, Shenzhen,China AlenHe Testedby(name+signature).......................: JoeLiu Reviewer(name+signature).......................: LakeXie Approved(name+signature).......................: ProjectNo.:ZKT-2302133L0664E Page 3 of 46 TableofContents Page 1.VERSION5 2.SUMMARYOFTESTRESULTS6 2.1TESTFACILITY7 2.2MEASUREMENTUNCERTAINTY7 3.GENERALINFORMATION8 3.1GENERALDESCRIPTIONOFEUT8 3.2DESCRIPTIONOFTESTMODES9 3.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED9 3.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE)9 3.5EQUIPMENTSLISTFORALLTESTITEMS11 4.EMCEMISSIONTEST13 4.1CONDUCTEDEMISSIONMEASUREMENT13 4.1.1POWERLINECONDUCTEDEMISSIONLIMITS13 4.1.2TESTPROCEDURE13 4.1.3DEVIATIONFROMTESTSTANDARD13 4.1.4TESTSETUP14 4.1.5EUTOPERATINGCONDITIONS14 4.1.6TESTRESULT15 4.2RADIATEDEMISSIONMEASUREMENT17 4.2.1RADIATEDEMISSIONLIMITS17 4.2.2TESTPROCEDURE17 4.2.3DEVIATIONFROMTESTSTANDARD18 4.2.4TESTSETUP18 4.2.5EUTOPERATINGCONDITIONS19 4.2.6TESTRESULTS19 5.RADIATEDBANDEMISSIONMEASUREMENT24 5.1TESTREQUIREMENT:24 5.2TESTPROCEDURE24 5.3DEVIATIONFROMTESTSTANDARD24 5.4TESTSETUP25 5.5EUTOPERATINGCONDITIONS25 5.6TESTRESULT25 6.POWERSPECTRALDENSITYTEST27 6.1APPLIEDPROCEDURES/LIMIT27 6.2TESTPROCEDURE27 6.3DEVIATIONFROMSTANDARD27 6.4TESTSETUP27 6.5EUTOPERATIONCONDITIONS27 ProjectNo.:ZKT-2302133L0664E Page 4 of 46 6.6TESTRESULT28 7.CHANNELBANDWIDTH&99%OCCUPYBANDWIDTH34 7.1APPLIEDPROCEDURES/LIMIT34 7.2TESTPROCEDURE34 7.3DEVIATIONFROMSTANDARD34 7.4TESTSETUP34 7.5EUTOPERATIONCONDITIONS34 7.6TESTRESULT35 8.PEAKOUTPUTPOWERTEST38 8.1APPLIEDPROCEDURES/LIMIT38 8.2TESTPROCEDURE38 8.3DEVIATIONFROMSTANDARD38 8.4TESTSETUP38 8.5EUTOPERATIONCONDITIONS38 8.6TESTRESULT39 9.CONDUCTEDBANDEDGEANDSPURIOUSEMISSION40 9.1APPLICABLESTANDARD40 9.2TESTPROCEDURE40 9.3DEVIATIONFROMSTANDARD40 9.4TESTSETUP40 9.5EUTOPERATIONCONDITIONS40 9.6TESTRESULTS40 10.ANTENNAREQUIREMENT45 11.TESTSETUPPHOTO46 12.EUTCONSTRUCTIONALDETAILS46 ProjectNo.:ZKT-2302133L0664E Page 5 of 46 1.VERSION ReportNo.VersionDescriptionApproved ZKT-230213L0664ERev.01InitialissueofreportFeb.22,2023 ProjectNo.:ZKT-2302133L0664E Page 6 of 46 2.SUMMARYOFTESTRESULTS Testproceduresaccordingtothetechnicalstandards: FCCPart15(15.247),SubpartC Standard Section TestItemResultRemark FCCpart15.203/15.247 (c) AntennarequirementPASS FCCpart15.207ACPowerLineConductedEmissionPASS FCCpart15.247(b)(3)ConductedPeakOutputPowerPASS FCCpart15.247(a)(2)ChannelBandwidth&99%OCBPASS FCCpart15.247(e)PowerSpectralDensityPASS FCCpart15.247(d)BandEdgePASS FCCpart15.205/15.209SpuriousEmissionPASS NOTE: (1)”N/A”denotestestisnotapplicableinthisTestReport ProjectNo.:ZKT-2302133L0664E Page 7 of 46 2.1TESTFACILITY ShenzhenZKTTechnologyCo.,Ltd. Add.:1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrialAvenue,FuhaiStreet,Bao'an District,Shenzhen,China FCCTestFirmRegistrationNumber:692225 DesignationNumber:CN1299 ICRegisteredNo.:27033 CABidentifier:CN0110 2.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U , whereexpendeduncertaintyUisbasedonastandard uncertaintymultipliedbyacoveragefactorofk=2 , providingalevelofconfidenceofapproximately95 % 。 No.ItemUncertainty 1 3mcamberRadiatedspurious emission(9KHz-30MHz) U=4.5dB 2 3mcamberRadiatedspurious emission(30MHz-1GHz) U=4.8dB 3 3mchamberRadiatedspurious emission(1GHz-6GHz) U=4.9dB 4 3mchamberRadiatedspurious emission(6GHz-40GHz) U=5.0dB 5ConducteddisturbanceU=3.2dB 6RFBandEdgeU=1.68dB 7RFpowerconductedU=1.86dB 8RFconductedSpuriousEmissionU=2.2dB 9RFOc…

Text truncated - open the document above for the full version.

Test Report

ProjectNo.:ZKT-2302133L0664E Page 34 of 46 7.CHANNELBANDWIDTH&99%OCCUPYBANDWIDTH TestRequirement:FCCPart15CSection15.247(a)(2) TestMethod:KDB558074D0115.247MeasGuidancev05r02 7.1APPLIEDPROCEDURES/LIMIT FCCPart15(15.247),SubpartC SectionTestItemLimit FrequencyRange (MHz) Result 15.247(a)(2)Bandwidth >=500KHz (6dBbandwidth) 2400-2483.5PASS 7.2TESTPROCEDURE 1.SetRBW=100kHz. 2.Setthevideobandwidth(VBW)≥3xRBW. 3.Detector=Peak. 4.Tracemode=maxhold. 5.Sweep=autocouple. 6.Allowthetracetostabilize. 7.Measurethemaximumwidthoftheemissionthatisconstrainedbythefrequenciesassociatedwiththe twooutermostamplitudepoints(upperandlowerfrequencies)thatareattenuatedby6dBrelativetothe maximumlevelmeasuredinthefundamentalemission. 7.3DEVIATIONFROMSTANDARD Nodeviation. 7.4TESTSETUP 7.5EUTOPERATIONCONDITIONS TheEUTtestedsystemwasconfiguredasthestatementsof2.4Unlessotherwiseaspecialoperating conditionisspecifiedinthefollowsduringthetesting. ProjectNo.:ZKT-2302133L0664E Page 35 of 46 7.6TESTRESULT Temperature: 26°C RelativeHumidity: 54% Pressure: 101kPa TestVoltage: AC120V TestMode : TXbMode TestCH -6dBOccupyBandwidth(MHz) 802.11b802.11g802.11n(HT20)Limit(KHz)Result Lowest10.0916.4017.14 >500Pass Middle9.5916.4017.17 Highest9.7616.4117.20 ProjectNo.:ZKT-2302133L0664E Page 36 of 46 Testplotasfollows: 802.11b802.11g Lowestchannel Middlechannel Highestchannel ProjectNo.:ZKT-2302133L0664E Page 37 of 46 n20 Lowestchannel Middlechannel Highestchannel ProjectNo.:ZKT-2302133L0664E Page 38 of 46 8.PEAKOUTPUTPOWERTEST TestRequirement:FCCPart15CSection15.247(b)(3) TestMethod:KDB558074D0115.247MeasGuidancev05r02 8.1APPLIEDPROCEDURES/LIMIT FCCPart15(15.247),SubpartC SectionTestItemLimit FrequencyRange (MHz) Result 15.247(b)(3) PeakOutput Power 1wattor30dBm2400-2483.5PASS 8.2TESTPROCEDURE a. TheEUTwasdirectlyconnectedtothePowermeter 8.3DEVIATIONFROMSTANDARD Nodeviation. 8.4TESTSETUP 8.5EUTOPERATIONCONDITIONS TheEUTtestedsystemwasconfiguredasthestatementsof2.4Unlessotherwiseaspecialoperating conditionisspecifiedinthefollowsduringthetesting. ProjectNo.:ZKT-2302133L0664E Page 39 of 46 8.6TESTRESULT Temperature : 26°C RelativeHumidity : 54% Pressure: 101kPa TestVoltage: AC120V Note: 1.Forpowertestthedutycycleis100%incontinoustransmittingmode; 2.TXmeansTransmit,RXmeansReceive. Test Channel Frequency (MHz) MaximumConductedOutputPower Total power (dBm) Limit (dBm) (dBm) TX802.11bMode CH012412 18.13 -30.00 CH062437 18.41 -30.00 CH112462 17.86 -30.00 TX802.11gMode CH01241215.36-30.00 CH06243715.78-30.00 CH11246215.02-30.00 TX802.11n(HT20)Mode CH01241215.42-30.00 CH06243715.85-30.00 CH11246215.11-30.00 ProjectNo.:ZKT-2302133L0664E Page 40 of 46 9.CONDUCTEDBANDEDGEANDSPURIOUSEMISSION TestRequirement:FCCPart15CSection15.247(d) TestMethod:KDB558074D0115.247MeasGuidancev05r02 9.1APPLICABLESTANDARD inany100kHzbandwidthoutsidethefrequencybandsinwhichthespreadspectrumintentionalradiatorin operating,theradiofrequencypowerthatisproducedbytheintentionalradiatorshallbeatleast20dBbelow thatinthe100kHzbandwidthwithinthebandthatcontainsthehighestlevelofthedesiredpower,Inaddition, radiatedemissionswhichfallintherestrictedbands,asdefinedin§15.205(a),mustalsocomplywiththe radiatedemissionlimitsspecifiedin15.209(a). 9.2TESTPROCEDURE Usingthefollowingspectrumanalyzersetting: A)Setth…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Stone feng
[email protected]+86-0755-86227808Fax: +86-0755-86227808

Technical Contact

Netvue Technologies Co.,Ltd.
[email protected]

China

Test Firm

Shenzhen ZKT Technology Co., Ltd.Lake Xie
[email protected]0086-13620010775

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz69.34 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Netvue Technologies Co., Ltd.

Orb Cam 2 - FCC ID 2AO8RNI-3431 - Netvue Technologies Co., Ltd.
2AO8RNI-3431

Orb Cam 2

Feb 05, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Birdfy Feeder Bamboo - FCC ID 2AO8RNI-8401 - Netvue Technologies Co., Ltd.
2AO8RNI-8401

Birdfy Feeder Bamboo

Sep 04, 2023

Equipment Class

DTS - Digital Transmission System
Home Cam 2 - FCC ID 2AO8RNI-3341 - Netvue Technologies Co., Ltd.
2AO8RNI-3341

Home Cam 2

May 17, 2021

Equipment Class

DTS - Digital Transmission System
Vigil Pro - FCC ID 2AO8RNI-1930 - Netvue Technologies Co., Ltd.
2AO8RNI-1930

Vigil Pro

Oct 13, 2020

Equipment Class

DTS - Digital Transmission System
Vigil 2 - FCC ID 2AO8RNI-1910 - Netvue Technologies Co., Ltd.
2AO8RNI-1910

Vigil 2

Sep 07, 2020

Equipment Class

DTS - Digital Transmission System