Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
The H5PD Dual Panic Button is an innovative wearable badge designed to deliver instant emergency response. Its compact design features dual buttons for customizable various clicks (double click, triple click, etc.), enabling users to trigger precise alerts. Using different forms, these two buttons are convenient for users to accurately distinguish in emergencies. With firmware-configurable functions for each button, the H5PD is ideal for personnel safety in various environments like hospitals, schools, hotels and more. Dual Panic Button H5PD Dual Button Precise Alert *Battery lifespan estimates are based on the default settings without accelerometer sensor – 1 active slot, 1000ms ADV interval and 0dBm Tx Power. Features Dual programmable buttons IP66 waterproof Replaceable battery Supports RFID Supports alarm feedback Supports silent alerting Applications ConstructionHotelSchool www.mokosmart.com General Specifications 50mm 68mm 6.6mm Connectivity Dimensions (mm) Weight Color Material IP rating Sensor LED Buzzer RFID/NFC Battery capacity Battery lifespan Operating temperature Transmission range Installation Certification BLE 5.0 68.0*50.0*6.6 Body - White | Button - Red&Blue PC IP65 Accelerometer Red | Green Ye s HF | LF/UHF (Customizable) 550mAh | Replaceable battery 3 years* -20°C/60°C Up to 150m (Without any obstacles) Lanyard FCC | CE | RohS | WEEE RFID 23g
Covered Equipment Certification Attestation MOKO TECHNOLOGY LIMITED Letter Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “cover ATTN.: Reviewing Engineer FCC ID: 2AO94-H5PD MOKO TECHNOLOGY LIMITED(“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules 4/15/2026 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada . ed” equipment. MOKO TECHNOLOGY LIMITED(“the applicant”) certifies that, as of the date of the filing of the application, the applicant is notidentified on the Covered List as an entity producing “ covered” equipment. MOKO TECHNOLOGY LIMITED(“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24- 886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Signed: Printed name: Title: Jinghui Chen SEO Company Name: MOKO TECHNOLOGY LIMITED Date: 4/15/2026
MOKOTECHNOLOGYLIMITED ReferenceNo.2025UD0131 U.S.AgentDesignationforServiceofProcess- CertificationAttestationLetter December15,2025 NemkoNorthAmerica,Inc. 303RiverRoad Ottawa K1V1H2 Canada ATTN.:ReviewingEngineer FCCID:2AO94-H5PDFRN:0027351667 Persection2.911(d)(7)oftheFCCrules, MOKOTECHNOLOGYLIMITEDcertifiesthat the equipmentforwhichauthorizationissoughtisdesignatedtothefollowingU.S.Designated agent*forserviceofprocess: CompanyName:TTSMARKETINC. PhysicalU.S.CompanyAddress:1178BroadwaySte324,NewYork,NY10001.USA Agentname:MaverickLim AgentEmailAddress:[email protected] FRN:0036806057 Theabovecontactpersonacceptstheobligationforserviceofprocess. Theapplicantacceptstomaintainanagentfornolessthanoneyearafterthegranteehas terminatedallmarketingandimportationortheconclusionofanyCommission-related proceedinginvolvingtheequipment. Validuntil:December09,2026 ApplicantSigned: DesignatedAgentSigned: (Required,ifdifferenttoApplicant): Signed:Signed: Printedname:JinghuiChenPrintedname:MaverickLim Title:SEOTitle:Manager CompanyName:MOKOTECHNOLOGYLIMITEDCompanyName:TTSMARKETINC. Date:2025-12-16Date:2025-12-16 * theapplicantmustdesignateacontactlocatedintheUnitedStatesforpurposesofactingasthe applicant’sagentforserviceofprocess,regardlessofwhethertheapplicantisadomesticorforeign entity.AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforserviceofprocess.
MOKO TECHNOLOGY LIMITED statementdifferenceModel EUT: Bluetooth Beacon Model Number: H5PD, H5PD-BNDA-ZNFCH5PD-BNDA-ZH5PD-BNDA H5PD-BNDN-ZNFC, H5PD-BNDN-Z,H5PD-BNDN,H5PD-BNDAX-ZNFC, H5PD-BNDAX-Z,H5PD-BNDAX FCC ID:2AO94- (The differences are only in model types, power supply methods and appearance; the product materials, circuits, antennas and RF modules remain identical.) H5PD Sincerely, Address : Factory 201, 107 Pinshun Rd Guixiang community, Guanlan Street, Longhua, Shenzhen, Printed name: Jinghui.Chen China 518110
MOKO TECHNOLOGY LIMITED Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada April15, 2026 K1V 1H2 REQUEST FOR CONFIDENTIALITY - FCC Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rulesand FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its FCC ID: 2AO94-H5PD competitors. Exhibit Type of Confidentiality Requested Block Diagrams ☐ Permanent ☐ Short Term External Photos ------------------ ☐ Short Term Internal Photos ☐ Permanent* ☐ Short Term Operation Description ☐Permanent ☐ Short Term Parts List & Placement/BOM ☐ ☐ Permanent Short Term Tune-Up Procedure ☐ Permanent ☐ Short Term Schematic Diagrams ☐ Permanent ☐ Short Term Test Setup Photos ------------------ ☐ Short Term User’s Manual ☐ Permanent* ☐ Short Term Sincerely, Signed: Printed name: Title: Jinghui Chen SEO Company Name: MOKO TECHNOLOGY LIMITED Date: 4/15/2025
Page 1 of 3 Report No.: psi2604045-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix II external photos FCC ID: 2AO94-H5PD Page 2 of 3 Report No.: psi2604045-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 3 of 3 Report No.: psi2604045-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China ------End------
LabelLocation
Page 1 of 1 Report No.: psi2604045-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix IV RF Exposure evaluation FCC ID: 2AO94-H5PD According to 447498 D01 General RF Exposure Guidance v06 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison. BLE: Worse case output power is as below: [2402MHz: 0.18dBm] Maximum output power is 0.18dBm (1.04 mW). (1.04mW /5mm)·[√2.402(GHz)]= 0.32<3.0 for 1-g SAR. Then SAR evaluation is not required.
深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. address701, Building A, No. 10, Jiangfu Road, Xinzhuang Community, Matian Street, Guangming District, Shenzhen Tester : Hu Lin Date HUACHUANG TECHNOLOGY LTD Antenna Test Report M/N: H5PD : 2025 /11/11 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. 1. Device Profile 2. 2.4G BT Test 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. 1. Device Profile BT Antenna X Y Z 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. Agilent E5071CS-Parameter Test 2. WIFI Antenna Test 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. Antenna Passive Test X Y Z X Y Z 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. Passive Test Frequency/M hz Efficiency/dBEfficiency/%MaxGain/dBi 2400-2.5255.984.35 2410-2.9151.173.73 2420-2.2459.74.89 2430-2.8352.124.02 2440-2.1760.674.93 2450-2.6754.084.38 2460-2.1660.814.6 2470-2.4856.494.59 2480-2.2959.024.08 2490-2.2459.74.82 2500-2.4357.153.66 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. 2D-Etotal (2400/2450/2500Mhz) Phi 0 2DPhi 90 2DTheta 90 2D 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. 3D-Etotal (2400Mhz) 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. 3D-Etotal (2450Mhz) 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. 3D-Etotal (2500Mhz) 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. THANK YOU!
Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Page 1 of 53 Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China FCC TEST REPORT FCC ID: 2AO94-H5PD On Behalf of MOKO TECHNOLOGY LIMITED Bluetooth Beacon Model No.: H5PD, H5PD-BNDA-ZNFC, H5PD-BNDA-Z, H5PD-BNDA, H5PD-BNDN-ZNFC, H5PD-BNDN-Z, H5PD-BNDN, H5PD-BNDAX-ZNFC, H5PD-BNDAX-Z, H5PD-BNDAX Prepared for : MOKO TECHNOLOGY LIMITED Address : Factory 201, 107 Pinshun Rd Guixiang community, Guanlan Street, Longhua, Shenzhen, China 518110 Prepared By : Shenzhen PSI Testing Co., Ltd. Address : 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Report Number : psi2604045-C01-R01 Date of Receipt : April 7, 2026 Date of Test : April 7, 2026–April 9, 2026 Date of Report : April 9, 2026 Version Number : V0 Page 2 of 53 Report No.: psi2604045-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China TABLE OF CONTENTS Description Pag e 1. Summary Of Standards And Results----------------------------------------------------------------------- 6 1.1. Description of Standards and Results ---------------------------------------------------------------- 6 2. General Information --------------------------------------------------------------------------------------------- 7 2.1. Description of Device (EUT) ---------------------------------------------------------------------------- 7 2.2. Accessories of Device (EUT) -------------------------------------------------------------------------- 8 2.3. Tested Supporting System Details -------------------------------------------------------------------- 8 2.4. Block Diagram of Connection Between EUT and Simulators ----------------------------------- 8 2.5. Test Mode Description ----------------------------------------------------------------------------------- 9 2.6. Software test version and power setting information --------------------------------------------- 9 2.7. Test Conditions ------------------------------------------------------------------------------------------ 10 2.8. Test Facility----------------------------------------------------------------------------------------------- 10 2.9. Measurement Uncertainty ---------------------------------------------------------------------------- 10 2.10. Test Equipment List ------------------------------------------------------------------------------------- 11 3. Spurious Emission -------------------------------------------------------------------------------------------- 12 3.1. Test Limits ------------------------------------------------------------------------------------------------ 12 3.2. Block Diagram of Test setup ------------------------------------------------------------------------- 13 3.3. Test Procedure ------------------------------------------------------------------------------------------ 14 3.4. Test Results ---------------------------------------------------------------------------------------------- 15 4. Power Line Conducted Emission ------------------------------------------------------------------------- 21 4.1. Test Limits ------------------------------------------------------------------------------------------------ 21 4.2. Test Procedure ------------------------------------------------------------------------------------------ 21 4.3. Test Setup ------------------------------------------------------------------------------------------------ 21 4.4. Test Results ---------------------------------------------------------------------------------------------- 22 5. Out-of-band Emissions -------------------------------------------------------------------------------------- 23 5.1. Test Limits ------------------------------------------------------------------------------------------------ 23 5.2. Test Procedure ------------------------------------------------------------------------------------------ 23 5.3. Test Setup ------------------------------------------------------------------------------------------------ 23 5.4. Test Results ---------------------------------------------------------------------------------------------- 23 6. Conducted Maximum Output Power --------------------------------------------------------------------- 34 6.1. Test limits ------------------------------------------------------------------------------------------------- 34 6.2. Test Procedure ------------------------------------------------------------------------------------------ 34 6.3. Test Setup ------------------------------------------------------------------------------------------------ 34 6.4. Test Results ---------------------------------------------------------------------------------------------- 34 7. Peak Power Spectral Density ------------------------------------------------------------------------------ 38 7.1. Test limits ------------------------------------------------------------------------------------------------- 38 7.2. Test Procedure ------------------------------------------------------------------------------------------ 38 7.3. Test Setup ------------------------------------------------------------------------------------------------ 38 7.4. Test Results ---------------------------------------------------------------------------------------------- 38 8. Occupied Bandwidth------------------------------------------------------------------------------------------ 42 8.1. Test limits ------------------------------------------------------------------------------------------------- 42 8.2. Test Procedure ------------------------------------------------------------------------------------------ 42 8.3. Test Setup ----------------------…
Text truncated - open the document above for the full version.
Page 1 of 1 Report No.: psi2604045-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix I Test Setup Photo FCC ID: 2AO94-H5PD Spurious Radiation Emissions Test (<1G) Spurious Radiation Emissions Test (>1G) ------End------
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.04 mW |

Smart Button
Equipment Class
DTS - Digital Transmission System
Bluetooth Beacon
Equipment Class
DTS - Digital Transmission System
Bluetooth Beacon
Equipment Class
DTS - Digital Transmission System
BLE to Cellular Gateway
Equipment Class
DTS - Digital Transmission System
Bluetooth-LoRaWAN Gateway
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter