FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Outform Science & Technology (Shenzhen) Co., Ltd./
  3. 2AO9X-UITH108-B02

2AO9X-UITH108-B028 inch iDisplay

Outform Science & Technology (Shenzhen) Co., Ltd.
8 inch iDisplay - FCC ID 2AO9X-UITH108-B02 - Outform Science & Technology (Shenzhen) Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 29, 2020
Application Purpose
Original Equipment
Date of Application
Jul 29, 2020
Equipment Note
8 inch iDisplay
Frequency Range
2412.00000000 - 2462.00000000
Company
Outform Science & Technology (Shenzhen) Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

UITH108-B02 8 inch iDisplay 2 3 4 1 2 CE NB Herby, Outform Science & Technology (Shenzhen) Co., Ltd. declares that this 8'' iDisplay measurement terminal, UITH108-B02 is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. In accordance with Article 10(2) and Article 10(10), this product allowed to be used in all EU member states. Use the 8'' iDisplay in the environment with the temperature between -20°C and 35°C, Adapter shall be installed near the equipment and shall be easily accessible. The plug considered as disconnect device of adapter Adapter Model: TDX-1202000 Input: AC 100-240V, 50/60Hz, 0.6A Output: DC 12V, 2.0A Operation Frequency: For WIFI: 2412MHz~2472MHz (802.11b/802.11g/802.11n(HT20)) Max output power: For WIFI: 0.0555W For BT: 0.003W Manufacturer:Shenzhen Sunchip Technology Co., Ltd. Address:2nd-3rd Floor, Building 4, Fuan Industry Area Phase 2, Dayang Development Zone, Fuyong, Baoan, Shenzhen, China Tel: 0755-23085934 Fax: 0755-23086272 E-mail: [email protected] FCC Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. For BT: 2402MHz~2480MHz

Cover Letter(s)

Outform Science & Technology (Shenzhen) Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date:2020-07-27 Subject; Request for Long Term Confidentiality FCC ID: 2AO9X-UITH108-B02 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Ronen Simhi Title: GM

Cover Letter(s)

Outform Science & Technology (Shenzhen) Co., Ltd. Unit 3, 1 st Floor, Huada Building, Gongye 3rd Road, Yanshan Community, Zhaoshang Subdistrict, Nanshan District, Shenzhen, China 518067 Statement Product: 8 inch iDisplay Model: UITH108-B02 Additional Model: UITH108-B03, UITH108-B04, UITH108-B05, UITH108-B06, UITH108-B07, UITH108-B08, UITH108-C02, UITH108-C03, UITH108-C04, UITH108-C05, UITH108-C06, UITH108-C07, UITH108-C08, UITH108-D02, UITH108-D03, UITH108-D04, UITH108-D05, UITH108-D06, UITH108-D07, UITH108-D08, UITH108-E02, UITH108-E03, UITH108-E04, UITH108-E05, UITH108-E06, UITH108-E07, UITH108-E08, RS-TS8B0 Trademark: We hereby state that All models above are identical in interior structure, electrical circuits and components, and just model names are different for the marketing requirement. Your assistance on this matter is highly appreciated. Yours sincerely, S ignature: Date: 2020/07/27 Name: Ronen Simhi Company Name : Outform Science & Technology (Shenzhen) Co., Ltd. Address: Unit 3, 1st Floor, Huada Building, Gongye 3rd Road, Yanshan Community, Zhaoshang Subdistrict, Nanshan District, Shenzhen, China 518067 Tel / Fax: 0086-755-83236715/0086-755-83236725 E- Mail: [email protected]

Cover Letter(s)

Outform Science & Technology (Shenzhen) Co., Ltd. Agent Authorization C ompany: Outform Science & Technology (Shenzhen) Co., Ltd. A ddress: Unit 3, 1st Floor, Huada Building, Gongye 3rd Road, Yanshan Community, Zhaoshang Subdistrict, Nanshan District, Shenzhen, 518067, China P roduct Name: 8 inch iDisplay M odel Number(s): UITH108-B02, UITH108-B03, UITH108-B04, UITH108-B05, UITH108-B06, UITH108-B07, UITH108-B08, UITH108-C02, UITH108-C03, UITH108- C04, UITH108-C05, UITH108-C06, UITH108-C07, UITH108-C08, UITH108-D02, UITH108-D03, UITH108-D04, UITH108-D05, UITH108-D06, UITH108-D07, UITH108- D08, UITH108-E02, UITH108-E03, UITH108-E04, UITH108-E05, UITH108-E06, UITH108-E07, UITH108-E08, RS-TS8B0 P roduct Description: 8 inch iDisplay W e authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. W e declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2020-07-27 Name: Ronen Simhi Title: GM Company: Outform Science & Technology (Shenzhen) Co., Ltd.

External Photos

Page 1 of 4 Appendix B: Photographs of EUT Product: 8 inch iDisplay Model: UITH108-B02 External Photos Page 2 of 4 Page 3 of 4 Page 4 of 4

ID Label/Location Info

Label Artwork and Location Model: UITH108-B02 Label: Size: L*W=60*30mm Location

Internal Photos

Page 1 of 14 Appendix B: Photographs of EUT Product: 8 inch iDisplay Model: UITH108-B02 Internal Photos Page 2 of 14 Page 3 of 14 Antenna Page 4 of 14 Page 5 of 14 Page 6 of 14 Page 7 of 14 Page 8 of 14 Page 9 of 14 Page 10 of 14 Page 11 of 14 Page 12 of 14 Page 13 of 14 Page 14 of 14

RF Exposure Info

Maximum Permissible Exposure FCC ID : 2AO9X-UITH108-B02 Applicable Standard According to §1.1307(b), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. For BT: Remark: 1) The maximum output power for antenna is 4.09dBm (2.56mW) at 2402MHz, 1dBi antenna gain(with 1.26 numeric antenna gain.) 2) For mobile or fixed location transmitters, no SAR consideration applied. The minimum separation generally be used is at least 20cm, even if the calculation indicate that the MPE distance would be lesser. Maximum Permissible Exposure output power= 2.56mW Numeric Antenna gain= 1.26 Substituting the MPE safe distance using d=20cm into above equation. Yields: S=0.000199*P*G Where P=Power in mW G=Numeric antenna gain S=Power density in mW/cm 2 Power density= 0.000642mW/cm 2 (For mobile or fixed location transmitters, the maximum power density is 1.0 mW/cm 2 even if the calculation indicates that the power density would be larger.) For WIFI: Remark: 1) The maximum output power for antenna is 16.97dBm (49.77mW) at 2437MHz, 1dBi antenna gain(with 1.26 numeric antenna gain.) 2) For mobile or fixed location transmitters, no SAR consideration applied. The minimum separation generally be used is at least 20cm, even if the calculation indicate that the MPE distance would be lesser. Maximum Permissible Exposure output power=49.77mW Numeric Antenna gain= 1.26 Substituting the MPE safe distance using d=20cm into above equation. Yields: S=0.000199*P*G Where P=Power in mW G=Numeric antenna gain S=Power density in mW/cm 2 Power density= 0.012479mW/cm 2 (For mobile or fixed location transmitters, the maximum power density is 1.0 mW/cm 2 even if the calculation indicates that the power density would be larger.)

Test Report

Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com TEST REPORT FCC ID: 2AO9X-UITH108-B02 Product: 8 inch iDisplay Model No.: UITH108-B02 Additional Model No.: UITH108-B03, UITH108-B04, UITH108-B05, UITH108-B06, UITH108-B07, UITH108-B08, UITH108-C02, UITH108-C03, UITH108-C04, UITH108-C05, UITH108-C06, UITH108-C07, UITH108-C08, UITH108-D02, UITH108-D03, UITH108-D04, UITH108-D05, UITH108-D06, UITH108-D07, UITH108-D08, UITH108-E02, UITH108-E03, UITH108-E04, UITH108-E05, UITH108-E06, UITH108-E07, UITH108-E08, RS-TS8B0 Trade Mark: Report No.: TCT200703E909 Issued Date: Jul. 24, 2020 Issued for: Outform Science & Technology (Shenzhen) Co., Ltd. Unit 3, 1st Floor, Huada Building, Gongye 3rd Road, Yanshan Community, Zhaoshang Subdistrict, Nanshan District, Shenzhen, 518067, China Issued By: Shenzhen Tongce Testing Lab. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China TEL: +86-755-27673339 FAX: +86-755-27673332 This report refers to TCT200615E029; Change product name, model, trade mark, applicant, manufacturer and their address Note: This report shall not be reproduced except in full, without the written approval of Shenzhen Tongce Testing Lab. This document may be altered or revised by Shenzhen Tongce Testing Lab. personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample. Report No.: TCT200703E909 Page 2 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com TABLE OF CONTENTS 1. Test Certification ..................................................................................... 3 2. Test Result Summary .............................................................................. 4 3. EUT Description ....................................................................................... 5 4. General Information ................................................................................. 7 4.1. Test environment and mode ................................................................................. 7 4.2. Description of Support Units ................................................................................ 8 5. Facilities and Accreditations .................................................................. 9 5.1. Facilities ................................................................................................................. 9 5.2. Location ................................................................................................................. 9 5.3. Measurement Uncertainty ..................................................................................... 9 6. Test Results and Measurement Data ................................................... 10 6.1. Antenna requirement .......................................................................................... 10 6.2. Conducted Emission ........................................................................................... 11 6.3. Maximum Conducted (Average) Output Power ................................................ 15 6.4. Emission Bandwidth ........................................................................................... 16 6.5. Power Spectral Density ....................................................................................... 17 6.6. Conducted Band Edge and Spurious Emission Measurement ....................... 18 6.7. Radiated Spurious Emission Measurement ...................................................... 20 Appendix A: Test Result of Conducted Test Appendix B: Photographs of Test Setup Appendix C: Photographs of EUT Report No.: TCT200703E909 Page 3 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 1. Test Certification Product: 8 inch iDisplay Model No.: UITH108-B02 Additional Model: UITH108-B03, UITH108-B04, UITH108-B05, UITH108-B06, UITH108-B07, UITH108-B08, UITH108-C02, UITH108-C03, UITH108-C04, UITH108-C05, UITH108-C06, UITH108-C07, UITH108-C08, UITH108-D02, UITH108-D03, UITH108-D04, UITH108-D05, UITH108-D06, UITH108-D07, UITH108-D08, UITH108-E02, UITH108-E03, UITH108-E04, UITH108-E05, UITH108-E06, UITH108-E07, UITH108-E08, RS-TS8B0 Trade Mark: Applicant: Outform Science & Technology (Shenzhen) Co., Ltd. Address: Unit 3, 1st Floor, Huada Building, Gongye 3rd Road, Yanshan Community, Zhaoshang Subdistrict, Nanshan District, Shenzhen, 518067, China Manufacturer: Outform Science & Technology (Shenzhen) Co., Ltd. Address: Unit 3, 1st Floor, Huada Building, Gongye 3rd Road, Yanshan Community, Zhaoshang Subdistrict, Nanshan District, Shenzhen, 518067, China Date of Test: Jun. 16, 2020 – Jul. 03, 2020 Applicable Standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 FCC KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.10:2013 The above equipment has been tested by Shenzhen Tongce Testing Lab. and found compliance with the requirements set forth in the technical standards mentioned above. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Tested By: Date: Jul. 03, 2020 Brave Zeng Reviewed By: Date: Jul. 24, 2020 Beryl Zhao Approved By: Date: Jul. 24, 2020 Tomsin Report No.: TCT200703E909 Page 4 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 2. Test Result Summary Requirement CFR 47 Section Result Antenna requirement §15.203/§15.247 (c) PASS AC Power Line Conducted Emission §15.207 PASS Conducted Peak Output Power §15.247 (b)(3) PASS 6dB Emission Bandwidth §15.247 (a)(2) PASS Power Spectral Density §15.247 (e) PASS Band Edge §15.247(d) PASS Spurious Emission §15.205/§15.209 PASS Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply…

Text truncated - open the document above for the full version.

Test Report

Report No.: TCT200703E909 Page 51 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Test Graphs 11B_Ant1_Low_2412 11B_Ant1_High_2462 11G_Ant1_Low_2412 Report No.: TCT200703E909 Page 52 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11G_Ant1_High_2462 11N20SISO_Ant1_Low_2412 11N20SISO_Ant1_High_2462 Report No.: TCT200703E909 Page 53 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Conducted Spurious Emission Test Result TestMode Antenna Channel FreqRange [Mhz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 11B Ant1 2412 Reference 8.57 8.57 --- PASS 30~1000 30~1000 -68.554 <=-21.431 PASS 1000~26500 1000~26500 -43.141 <=-21.431 PASS 2437 Reference 8.30 8.30 --- PASS 30~1000 30~1000 -67.916 <=-21.699 PASS 1000~26500 1000~26500 -42.433 <=-21.699 PASS 2462 Reference 8.07 8.07 --- PASS 30~1000 30~1000 -67.389 <=-21.925 PASS 1000~26500 1000~26500 -42.891 <=-21.925 PASS 11G Ant1 2412 Reference 4.78 4.78 --- PASS 30~1000 30~1000 -68.218 <=-25.216 PASS 1000~26500 1000~26500 -42.551 <=-25.216 PASS 2437 Reference 5.00 5.00 --- PASS 30~1000 30~1000 -68.499 <=-24.998 PASS 1000~26500 1000~26500 -42.189 <=-24.998 PASS 2462 Reference 3.92 3.92 --- PASS 30~1000 30~1000 -68.559 <=-26.079 PASS 1000~26500 1000~26500 -42.823 <=-26.079 PASS 11N20SISO Ant1 2412 Reference 3.08 3.08 --- PASS 30~1000 30~1000 -68.382 <=-26.925 PASS 1000~26500 1000~26500 -42.567 <=-26.925 PASS 2437 Reference 4.38 4.38 --- PASS 30~1000 30~1000 -68.999 <=-25.625 PASS 1000~26500 1000~26500 -42.414 <=-25.625 PASS 2462 Reference 3.16 3.16 --- PASS 30~1000 30~1000 -68.465 <=-26.837 PASS 1000~26500 1000~26500 -42.355 <=-26.837 PASS Report No.: TCT200703E909 Page 54 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Test Graphs 11B_Ant1_2412_0~Reference 11B_Ant1_2412_30~1000 11B_Ant1_2412_1000~26500 Report No.: TCT200703E909 Page 55 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11B_Ant1_2437_0~Reference 11B_Ant1_2437_30~1000 11B_Ant1_2437_1000~26500 11B_Ant1_2462_0~Reference Report No.: TCT200703E909 Page 56 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11B_Ant1_2462_30~1000 11B_Ant1_2462_1000~26500 11G_Ant1_2412_0~Reference Report No.: TCT200703E909 Page 57 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11G_Ant1_2412_30~1000 11G_Ant1_2412_1000~26500 11G_Ant1_2437_0~Reference Report No.: TCT200703E909 Page 58 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11G_Ant1_2437_30~1000 11G_Ant1_2437_1000~26500 11G_Ant1_2462_0~Reference Report No.: TCT200703E909 Page 59 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11G_Ant1_2462_30~1000 11G_Ant1_2462_1000~26500 11N20SISO_Ant1_2412_0~Reference Report No.: TCT200703E909 Page 60 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N20SISO_Ant1_2412_30~1000 11N20SISO_Ant1_2412_1000~26500 11N20SISO_Ant1_2437_0~Reference Report No.: TCT200703E909 Page 61 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N20SISO_Ant1_2437_30~1000 11N20SISO_Ant1_2437_1000~26500 11N20SISO_Ant1_2462_0~Reference Report No.: TCT200703E909 Page 62 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N20SISO_Ant1_2462_30~1000 11N20SISO_Ant1_2462_1000~26500 Report No.: TCT200703E909 Page 63 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Duty Cycle Test Result TestMode Antenna Channel Transmission Duration [ms] Transmission Period [ms] Duty Cycle [%] Limit Verdict 11B Ant1 2412 50.00 50.00 100.00 --- PASS 2437 50.00 50.00 100.00 --- PASS 2462 50.00 50.00 100.00 --- PASS 11G Ant1 2412 50.00 50.00 100.00 --- PASS 2437 50.00 50.00 100.00 --- PASS 2462 50.00 50.00 100.00 --- PASS 11N20SISO Ant1 2412 50.00 50.00 100.00 --- PASS 2437 50.00 50.00 100.00 --- PASS 2462 50.00 50.00 100.00 --- PASS Report No.: TCT200703E909 Page 64 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Report No.: TCT200703E909 Page 65 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11G_Ant1_2412 11G_Ant1_2437 11G_Ant1_2462 11N20SISO_Ant1_2412 Report No.: TCT200703E909 Page 66 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 11N20SISO_Ant1_2437 11N20SISO_Ant1_2462 Report No.: TCT200703E909 Page 67 of 67 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Appendix A: Photographs of Test Setup Refer to the test report No. TCT200703E901 Appendix B: Photographs of EUT Refer to the test report No. TCT200703E901 *****END OF REPORT*****

Test Setup Photos

Page 1 of 2 Appendix A: Photographs of Test Setup Product: 8 inch iDisplay Model: UITH108-B02 Radiated Emission Page 2 of 2 Conducted Emission

Contact Information

Applicant

Ronen Simhi(GM)
[email protected]0086-755-83236716Fax: 0086-755-83236725

Technical Contact

Outform Science & Technology (Shenzhen) Co., Ltd.
[email protected]

China

Test Firm

SHENZHEN TONGCE TESTING LABBeryl Zhao
[email protected]+8675527208735

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz49.80 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Outform Science & Technology (Shenzhen) Co., Ltd.

13.3 TABLET - FCC ID 2AO9X-T513 - Outform Science & Technology (Shenzhen) Co., Ltd.
2AO9X-T513

13.3 TABLET

Sep 18, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Micro Zappa Unit + Zappa Expansion Unit - FCC ID 2AO9X-UA200941-Z - Outform Science & Technology (Shenzhen) Co., Ltd.
2AO9X-UA200941-Z

Micro Zappa Unit + Zappa Expansion Unit

Jul 18, 2022

Equipment Class

NII - Unlicensed National Information Infrastructure TX
21.5 Touch Display - FCC ID 2AO9X-T421S11 - Outform Science & Technology (Shenzhen) Co., Ltd.
2AO9X-T421S11

21.5 Touch Display

Jun 07, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Touch Disp - FCC ID 2AO9X-T432S11 - Outform Science & Technology (Shenzhen) Co., Ltd.
2AO9X-T432S11

Touch Disp

Nov 18, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
OSM RFID 4P - FCC ID 2AO9X-RFID4P - Outform Science & Technology (Shenzhen) Co., Ltd.
2AO9X-RFID4P

OSM RFID 4P

Jul 29, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter