FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Esorun Technology Co.,LTD/
  3. 2AP2N-QOO

2AP2N-QOOMini Wireless Charger with Suction-cups

Shenzhen Esorun Technology Co.,LTD
Mini Wireless Charger with Suction-cups - FCC ID 2AP2N-QOO - Shenzhen Esorun Technology Co.,LTD
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jan 03, 2021
Application Purpose
Original Equipment
Date of Application
Dec 22, 2020
Equipment Note
Mini Wireless Charger with Suction-cups
Frequency Range
0.11500000 - 0.20500000
Company
Shenzhen Esorun Technology Co.,LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

63x13mm 1. Connect the USB-A cable to the QC adapter.The red LED light is on when the power is plugged in. QOO This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) this device must accept any interference received,including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. FCC RF exposure statement: The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected. 115-205kHz -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected -Consult the dealer or an experienced radio/TV technician for help.

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Company: Shenzhen Esorun Technology Co., Ltd. Address: 425(E02), No. 5 Golf Avenue, Guangpei Community, Guanlan Street, Longhua District, Shenzhen, China Product Name: Mini Wireless Charger with Suction-cups Model Number: Qoo FCC Identifier: 2AP2N-QOO We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Zhang Yi Date: 12/12/2020 Title: Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.1 1/1 Shenzhen Esorun Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 12/12/2020 Subject: Request for Confidentiality FCC ID: 2AP2N-QOO To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality ID Label/Location No No Attestation Statement No No External Photos No Block Diagram Schematics Test Report No No Test Setup Photos No User’s Manual Internal Photos Parts List / Tune Up RF Exposure Info Operational Description Cover Letter(s) No No SDR Software / Security Info No Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Zhang Yi Date: 12/12/2020 Title:

External Photos

1 - Page 1 of 5 - Report No.: MTi20101008-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. APPENDIX 1: EUT PHOTO Photo 1 (For model Qoo) Photo 2 1 - Page 2 of 5 - Report No.: MTi20101008-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 3 Photo 4 1 - Page 3 of 5 - Report No.: MTi20101008-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 5 Photo 6 1 - Page 4 of 5 - Report No.: MTi20101008-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 7 Photo 8 1 - Page 5 of 5 - Report No.: MTi20101008-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 9 ----END OF REPORT----

ID Label/Location Info

FCC ID: 2AP2N-QOO

Internal Photos

1 - Page 1 of 2 - Report No.: MTi20101008-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. APPENDIX 1: EUT PHOTO Photo 1 (For model Qoo) Photo 2 1 - Page 2 of 2 - Report No.: MTi20101008-7E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 3 Photo 4 ----END OF REPORT---- Coil Antenna

RF Exposure Info

This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. EXPOSURE REPORT FCC ID: 2AP2N-QOO Date of issue: Nov. 12, 2020 Report Number: MTi20101008-7E2 Sample Description: Mini Wireless Charger with Suction-cups Model(s): Qoo Applicant: Shenzhen Esorun Technology Co., Ltd. Address: 425(E02),No. 5 Golf Avenue, Guangpei Community, Guanlan Street, Longhua District, Shenzhen, China Date of Test: Nov. 02, 2020 –Nov. 12, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 9 - Report No.: MTi20101008-7E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Test Result Certification Applicant’s name: Shenzhen Esorun Technology Co., Ltd. Address: 425(E02),No. 5 Golf Avenue, Guangpei Community, Guanlan Street, Longhua District, Shenzhen, China Manufacture's name: Shenzhen Yostand Technology Co., Ltd. Address: East Factory, 10th Floor, Mingzhuo Building, Mingzhuo Xingye Science and Technology Park, Guangming Street, Guangming New District, Shenzhen, China Product name: Mini Wireless Charger with Suction-cups Trademark: ESORUN Model name: Qoo Standard: FCC CFR 47 PART 1 , 1.1310 RF Exposure Procedures: KDB 680106 D01 RF Exposure Wireless Charging App v03 This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that the equipment under test (EUT) compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by: Danny Xu Nov. 12, 2020 Reviewed by: Leo Su Nov. 12, 2020 Approved by: Tom Xue Nov. 12, 2020 - Page 3 of 9 - Report No.: MTi20101008-7E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. 1 General Information 1.1 Description of EUT Product name: Mini Wireless Charger with Suction-cups Brand name: N/A Model name: Qoo Series model: N/A Deference in serial model: N/A Operation frequency: 115–205 kHz Operational mode: Wireless charging Modulation type: ASK Antenna type: Coil Antenna Power source: DC 12V from adapter AC 120V/60Hz Battery: N/A Adapter information: N/A 1.2 Ancillary equipment list Equipment Model S/N Manufacturer Mobile phone S9+ / SAMSUNG Adapter HW-090200CH0 / Huizhou BYD Electronics Co., Ltd. 1.3 Measurement uncertainty Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y) Radiated emission(150kHz~30MHz) ± 2.5 dB Radiated emission(30MHz~1GHz) ± 4.2 dB Radiated emission (above 1GHz) ± 4.3 dB Temperature ±1 degree Humidity ± 5 % - Page 4 of 9 - Report No.: MTi20101008-7E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. 2 Testing site Test Site Shenzhen Microtest Co., Ltd Test Site Location 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. FCC Registration No.: 448573 - Page 5 of 9 - Report No.: MTi20101008-7E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. 3 List of test equipment Equipment No. Equipment Name Manufacturer Model Serial No. Calibration date Due date MTI-E060 Broadband Field Meter Narda Safety Test Solutions GmbH NBM- 520 D-1699 2020/06/22 2021/06/21 MTI-E061 Probe E-Field Narda Safety Test Solutions EF0691 H-0571 2020/06/22 2021/06/21 - Page 6 of 9 - Report No.: MTi20101008-7E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. 4 Test Results 4.4 Maximum permissible exposure 4.4.1 Limit Frequency range(MHz) Electric field strength(V/m) Magnetic field strength(A/m) Power density(mW/cm2) Averaging time(minutes) (A) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *100 6 3.0-30 1842/f 4.89/f *900/f 2 6 30-300 61.4 0.163 1.0 6 6 300-1500 f/300 6 1500-100000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *100 30 1.34-30 824/f 2.19/f *180/f 2 30 30-300 27.5 0.073 0.2 30 300-1500 f/1500 30 1500-100000 1 30 f = frequency in MHz * = Plane-wave equivalent power density 4.4.2 Te s t Procedures E and H-field measurements should be made with the center of the probe at a distance of 15 cm surrounding the device and 20 cm above the top surface of the primary/client pair. These measurements should be repeated for three different client battery levels, 1%, 50%, and 99%. Record the test results. KDB 680106 D01 RF Exposure Wireless Charging App v03: (1) Power transfer frequency is less than 1MHz. (2) Output power from each primary coil is less than or equal to 15 watts. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. (4) Client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). (…

Text truncated - open the document above for the full version.

Test Report

This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Test Report FCC ID: 2AP2N-Q OO Date of issue: N o v. 12, 2020 Report number: MTi20101008-7E1 Sample description: Mini Wireless Charger with Suction-cups Model(s): Qoo Applicant: Shenzhen Esorun Technology Co., Ltd. Address: 425(E02),No. 5 Golf Avenue, Guangpei Community, Guanlan Street, Longhua District, Shenzhen, China Date of test: No v. 02, 2020 –No v. 12, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 24 - Report No.: MTi20101008-7E1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Table of Contents 1 GENERAL INFORMATION ................................................................................................................................... 4 1.1 FEATURE OF EQUIPMENT UNDER TEST (EUT) ................................................................................................................... 4 1.2 TEST MODE .............................................................................................................................................................. 4 1.3 EUT TEST SETUP........................................................................................................................................................ 5 1.4 ANCILLARY EQUIPMENT .............................................................................................................................................. 5 2 SUMMARY OF TEST RESULT ............................................................................................................................... 6 2.1 OPERATION CHANNEL LIST ........................................................................................................................................... 6 2.2 TEST CHANNEL .......................................................................................................................................................... 6 3 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 7 3.1 TEST LABORATORY ..................................................................................................................................................... 7 3.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 7 3.3 MEASUREMENT UNCERTAINTY ...................................................................................................................................... 7 3.4 TEST SOFTWARE ........................................................................................................................................................ 7 4 LIST OF TEST EQUIPMENT .................................................................................................................................. 8 5 TEST RESULTS ..................................................................................................................................................... 8 5.1 ANTENNA REQUIREMENT ............................................................................................................................................ 9 5.1.1 Standard requirement ................................................................................................................................. 9 5.1.2 EUT Antenna ............................................................................................................................................... 9 5.2 CONDUCTED EMISSION ............................................................................................................................................. 10 5.2.1 Limits ......................................................................................................................................................... 10 5.2.2 Test Procedures ......................................................................................................................................... 10 5.2.3 Test Setup .................................................................................................................................................. 10 5.2.4 Test Result ................................................................................................................................................. 10 5.3 RADIATED EMISSION ................................................................................................................................................. 15 5.3.1 Limits ......................................................................................................................................................... 15 5.3.2 Test Procedures ......................................................................................................................................... 16 5.3.3 Test Setup .................................................................................................................................................. 17 5.3.4 Test Result ................................................................................................................................................. 17 5.4 OCCUPIED BANDWIDTH............................................................................................................................................. 21 5.4.1 Test method .......................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Model: Qoo Radiated emission Conducted emission

Contact Information

Applicant

Zhang Yi
[email protected]0086-0755-23696752Fax: /

Technical Contact

Shenzhen Microtest Co., LtdSmith Chen
[email protected]86-755 88850135

Shenzhen · China

Test Firm

Shenzhen Microtest Co., Ltd.Selby Liao
[email protected]0755-88850135-1193

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.115 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Shenzhen Esorun Technology Co.,LTD

Magnet Wireless Charger - FCC ID 2AP2N-IPR26 - Shenzhen Esorun Technology Co.,LTD
2AP2N-IPR26

Magnet Wireless Charger

Feb 05, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Magnetic Wireless Charging - FCC ID 2AP2N-PR1S - Shenzhen Esorun Technology Co.,LTD
2AP2N-PR1S

Magnetic Wireless Charging

Sep 29, 2025

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Power Bank - FCC ID 2AP2N-X1045 - Shenzhen Esorun Technology Co.,LTD
2AP2N-X1045

Wireless Power Bank

May 07, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
3in1 Wireless charging station - FCC ID 2AP2N-FARER - Shenzhen Esorun Technology Co.,LTD
2AP2N-FARER

3in1 Wireless charging station

Apr 17, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Charger - FCC ID 2AP2N-SUPER - Shenzhen Esorun Technology Co.,LTD
2AP2N-SUPER

Wireless Charger

Feb 13, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz