FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. HERMOS AG/
  3. 2AP5OLFM-4X

2AP5OLFM-4XLFM Reader

HERMOS AG
LFM Reader - FCC ID 2AP5OLFM-4X - HERMOS AG
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jan 12, 2020
Application Purpose
Original Equipment
Date of Application
Jan 12, 2020
Equipment Note
LFM Reader
Frequency Range
0.13420000 - 0.13420000
Company
HERMOS AG
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Vorstand: Jörg Herrmannsdörfer, Uwe Herrmannsdörfer, Harald Köhler HERMOS AG Vorsitzender des Aufsichtsrates: Peter Heun, Rechtsanwalt Gartenstraße 19 AG Bayreuth, HRB 3996, USt-IdNr: DE 236437317 D-95490 Mistelgau Bankverbindungen: HypoVereinsbank AG Bayreuth, Konto 329 829 383, BLZ 773 200 72 IBAN: DE63 7732 0072 0329 8293 83, SWIFT: HypoVereinsbank AG HYVEDEMM412 Telefon: +49 (9279) 991-0 Commerzbank AG Bayreuth, Konto 1 311 166, BLZ 773 400 76 Telefax: +49 (9279) 991-100 IBAN: DE16 7734 0076 0131 1166 00, BIC: COBADEFF773 e-mail: [email protected] VR-Bank Bayreuth, Konto 9 603 743, BLZ 773 900 00 http://www.hermos.com Mistelgau, Seite 1 von 1 PHOENIX TESTLAB GmbH Date: 13 January 2020 Product Certification Königswinkel 10 D 32825 Blomberg FCC ID: 2AP5OLFM-4X Subject: Professional Installation To Whom It May Concern: We hereby declare, that the device with the above referenced FCC ID is subject to Professional Installation and complies with the applicable requirements as defined in KDB353028 D01 Antennas Part 15 Transmitters. The device will be certified with a ferrite-antenna HRF.A.LFX.SM.SS.15 and marketed exclusively for use in industrial environments as documented in the FCC filing. We have full control over the marketing as it can only be purchased directly from us, so that we know each individual customer. Especially the proper set-up with countless of different selection features requires skilled technical competence and understanding of the system. Either we offer dedicated installation training sessions, or the device will be alternatively installed by our own staff. If you have any questions, please feel free to contact me. Yours sincerely, Lothar Düngfelder, Development, T&T

Users Manual

HERMOS AG LFM 4x Reader Rev1.3 Gartenstraße 19 • 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: [email protected] back to the table of contents www.hermos.com 1 WE GENERATE SOLUTIONS Englisch Customer manual LFM 4x Reader Rev1.4 RFID Customer manual LFM 4x Reader RFID WE GENERATE SOLUTIONS HERMOS AG Gartenstraße 19 • 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: [email protected] LFM 4x Reader Rev1.4 2 www.hermos.com 0. Table of contents 0. Table of contents .................................................................................................................................. 2 1 . I n t r o d u c t i o n ............................................................................................................................... 6 1.1 Using the device 7 2. Version history ...................................................................................................................................... 8 3. Used abbreviations and designations ................................................................................................... 8 4. General instructions .............................................................................................................................. 9 4.1 Objective of the product manual 9 4.2 Warranty and liability 9 5. Safety instructions and warnings ........................................................................................................ 10 5.1 Scope and symbols 10 5.2 Safety symbols - according to DIN 4844-2 10 5.2.1 Mandatory signs 11 5.2.2 Warning signs 11 5.2.3 Prohibition signs 11 5.2.4 Other signs 12 5.3 Obligations 12 5.3.1 Operator’s obligations 12 5.3.2 Responsibilities of operating personnel 13 5.3.3 ESD Instructions 13 5.4 Residual risks 14 5.5 Supplemental instructions 15 5.5.1 Regulations and certifications 15 6. Functional description ......................................................................................................................... 16 6.1 General information 16 6.2 Basic functions - operating modes 16 6.2.1 Normal operation 16 6.2.2 Polling mode 16 6.2.4 Test module 16 6.3.1 Top view 17 6.3.2 Front view 18 6.3.3 Back view 19 6.4 Technical Specification 20 6.4.1 Power supply and current input 20 6.4.2 Device labels 21 6.4.3 Device Label FCC ID 2AP5OLFM-4x 21 Feh Customer manual LFM 4x Reader RFID WE GENERATE SOLUTIONS HERMOS AG Gartenstraße 19 • 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: [email protected] LFM 4x Reader Rev1.4 3 www.hermos.com ler! Textmarke nicht definiert. 6.4.4 Test mode sticker 22 7. Installation ........................................................................................................................................... 23 7.1 Safety instructions 23 7.2 Qualified installation personnel 24 7.3 Unpacking 24 7.4 Mounting the device 25 7.5 Installing the antenna 26 7.5.1 Positioning the antenna 26 7.5.2 Rod Antenna M dimensions 27 7.5.3 Connecting the antenna 27 7.6 Power Supply 27 7.7 DIP-switch 28 7.8 RS232 connection 29 8.Commissioning .................................................................................................................................... 30 8.1 Operating conditions 30 8.2 The serial interface parameters 30 8.3 Parameter of the ethernet interface 31 8.3.1 Change networksettings with DeviceDiscoverer 31 8.3.2 Firmware update with DeviceDiscoverer 33 8.3.3 Test Device with DeviceDiscoverer 34 9. Operating ............................................................................................................................................ 37 9.1 Operating personnel 37 9.2 Protocol change 37 9.2.1 General 37 9.2.2 Automatic protocol detection 37 9.3 Addressing the antenna port 38 9.4 Customer Factoryparametersets 39 10. ASCI-I1 Communication protocol ..................................................................................................... 40 10.1 Structure of the communication protocol 40 10.2 Packet content 40 Packet header 40 Message data 41 Packet end 41 10.3 Data elements 42 10.4 Protocol Commands 45 10.4.1 X - Read data 47 10.4.2 R – Automatic read 48 10.4.3 W - Write data 49 Customer manual LFM 4x Reader RFID WE GENERATE SOLUTIONS HERMOS AG Gartenstraße 19 • 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: [email protected] LFM 4x Reader Rev1.4 4 www.hermos.com 10.4.4 G – Query parameter 50 10.4.5 F – Query parameter 51 10.4.6 P – Set parameter 52 10.4.7 N – Reset 53 10.4.8 e – Error message 54 10.4.9 E – Error message 54 10.4.10 H – Heartbeat 55 10.4.11 V – Query software version 56 10.4.12 L - Lock data area 57 10.4.13 I – Adjust RF module 58 10.4.14 J – RF module Queries the vote 59 10.4.15 A – Sensor event object removed 60 10.4.16 B – Sensor event object detected 61 10.4.17 O – Set output 62 10.4.18 Q – Querying the status of the inputs and outputs 63 10.5 Parameter 64 10.6 Message examples 67 10.7 Error Codes 69 10.8 Wiring of the outputs 71 10.8.1 ASC-W1 Mode: Reader in operation mode and sensor triggered reading 71 10.8.2 ASC-W1-Mode: Reader in operation mode and external triggered reading 73 10.9 ASCII – table 75 11.SECS / HSMS Communications protocol .......................................................................................... 78 11.1 Structure of a message 78 11.2 Directory Data Elements 81 11.3 Protocol commands 87 11.3.1 Stream 1 (system state) 88 11.3.2 Stream 2 (system control) 89 11.3.3 Stream 3 (Material-state) 91 11.3.4 Stream 5 (Exception handling) 93 11.3.5 Stream 9 (system error) 93 11.3.6 Stream 18 (control and data transfer) 95 11.4 Parameter 101 11.5 Examples of a SECS / HSMS message 109 11.6 Error codes 110 12. Service and Troubleshooting ................................................................................................... 111 12.1 General information 111 12.2 Troubleshooting personnel 111 Customer manual LFM 4x Reader RFID WE GENERATE SOLUTIONS HERMOS AG Gartenstraße 19 • 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: [email protected] LFM 4x Reader…

Text truncated - open the document above for the full version.

Cover Letter(s)

Vorstand: Harald Köhler, Jörg Herrmannsdörfer, Uwe Herrmannsdörfer, HERMOS AG Vorsitzender des Aufsichtsrates: Peter Heun, Rechtsanwalt Gartenstraße 19 AG Bayreuth, HRB 3996, USt-IdNr: DE 236437317 D-95490 Mistelgau Bankverbindungen: HypoVereinsbank AG Bayreuth, Konto 329 829 383, BLZ 773 200 72 IBAN: DE63 7732 0072 0329 8293 83, SWIFT: HypoVereinsbank AG HYVEDEMM412 Telefon: +49 (9279) 991-0 Commerzbank AG Bayreuth, Konto 1 311 166, BLZ 773 400 76 Telefax: +49 (9279) 991-100 IBAN: DE16 7734 0076 0131 1166 00, BIC: COBADEFF773 e-mail: [email protected] VR-Bank Bayreuth, Konto 9 603 743, BLZ 773 900 00 http://www.hermos.com Ihr Zeichen: Ihre Nachricht: Unser Zeichen: LD Mistelgau, 25.11.2019 Seite 1 von 1 HERMOS AG, Gartenstraße 19, 95490 Mistelgau PHOENIX TESTLAB GmbH Product Certification Department Königswinkel 10 D 32825 Blomberg To Whom It May Concern: Please be advised that we (Hermos AG, Gartenstr. 19, 95490 Mistelgau) authorizes the following persons from EMV Testhaus GmbH:  Mr. Tobias Zollner  Mr. Christian Kiermeier  Mr. Konrad Graßl to handle the application of Type Approval Services for the following countries: USA Unless future correspondence from us, please extend your full cooperation to EMV Testhaus GmbH regarding matters to 6 months after the signatory date of this authorization. Contact person Düngfelder Lothar Position in the company Expert Hardware Development Date of signatory 2019-11-25 ___________________________ Signatory (Signature of the applicant)

Cover Letter(s)

Long/Short-term Confidentiality Request PHOENIX TESTLAB GmbH Date: 25 November 2019 Product Certification Königswinkel 10 D 32825 Blomberg FCC ID: 2AP5OLFM-4X To Whom It May Concerns, Pursuant to sections 0.457(d) and 0.459 of CFR 47 and to avoid premature release of sensitive information prior to marketing or release of the product to the public, we hereby request long-term confidential treatment of information accompanying this application as outlined below: ☒ Schematics ☒ Parts List ☒ Block Diagram ☐ Tune-Up Info ☒ Operational Description In addition we hereby request the following exhibits contained in this application to be temporarily (short-term confidentiality) withheld from the public disclosure ☐ for an initial period of days ☐ until: ☒ not applicable ☐ External Photos ☐ Test Setup Photos ☐ Internal Photos ☐ Users Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457(d), disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application. If you have any questions, please feel free to contact me. Yours sincerely, Tobias Zollner Head of Product Compliance Management

External Photos

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex B Page 1 of 5 1 Annex B – EUT pictures 1.1 List of Pictures Picture 1: RFID reader – top view ...................................................................................... 2 Picture 2: RFID reader – back view ................................................................................... 2 Picture 3: Name plate – front view ..................................................................................... 3 Picture 4: Ports – front view ............................................................................................... 3 Picture 5: Antenna connectors – front view ....................................................................... 4 Picture 6: Antenna cable with tag – top view ..................................................................... 4 Picture 7: Tag – top view ................................................................................................... 5 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex B Page 2 of 5 Picture 1: RFID reader – top view Picture 2: RFID reader – back view EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex B Page 3 of 5 Picture 3: Name plate – front view Picture 4: Ports – front view EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex B Page 4 of 5 Picture 5: Antenna connectors – front view Picture 6: Antenna cable with tag – top view EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex B Page 5 of 5 Picture 7: Tag – top view

Internal Photos

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex C Page 1 of 4 1 Annex C – documentation 1.1 List of Pictures Picture 1: Board with front plate, top view.......................................................................... 2 Picture 2: Board, top view .................................................................................................. 2 Picture 3: Board, back view ............................................................................................... 3 Picture 4: Front plate with RS232 connector, top view ...................................................... 3 Picture 5: Housing, front view ............................................................................................ 4 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex C Page 2 of 4 Picture 1: Board with front plate, top view Picture 2: Board, top view EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex C Page 3 of 4 Picture 3: Board, back view Picture 4: Front plate with RS232 connector, top view EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex C Page 4 of 4 Picture 5: Housing, front view

Test Report

All test results relate to the items tested only. For reproduction of extracts of this test report, the written approval of EMV TESTHAUS GmbH is required. Applicant: HERMOS AG Gartenstr. 19 95490 Mistelgau Tel.: +49 9279 991-0 Fax: +49 9279 991-100 Test report no.: 190752-AU01+W01 for: HERMOS AG RFID Reader LFM Reader 4x according to: 15.207 15.209 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID Reader LFM Reader 4x 190752-AU01+W01 Page 2 of 37 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Tel.: +49 9421 56868-0 Fax: +49 9421 56868-100 Email: [email protected] Accreditation: FCC test firm accreditation expiration date: 2021-05-30 MRA US-EU, FCC designation number: DE0010 FCC registration number: 97268 BnetzA-CAB-02/21-02/5 Valid until 2023-11-26 Test laboratory: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany The technical accuracy is guaranteed through the quality management of EMV TESTHAUS GmbH. EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID Reader LFM Reader 4x 190752-AU01+W01 Page 3 of 37 Table of contents 1 Summary of test results ............................................................................................................ 6 2 Referenced publications ........................................................................................................... 7 3 Equipment under test (EUT) ..................................................................................................... 8 3.1 General information ........................................................................................................... 8 3.2 Radio specifications ........................................................................................................... 9 3.3 Photo documentation ......................................................................................................... 9 4 Test configuration and mode of operation ............................................................................... 10 4.1 Test configuration ............................................................................................................ 10 4.2 Mode of operation ............................................................................................................ 10 5 Test procedures...................................................................................................................... 11 5.1 General specifications ..................................................................................................... 11 5.2 AC power line conducted emission .................................................................................. 11 5.3 Radiated emissions below 30 MHz .................................................................................. 13 5.4 Radiated emissions from 30 MHz to 1 GHz ..................................................................... 15 5.5 Radiated emissions above 1 GHz .................................................................................... 17 5.6 Bandwidth measurements ............................................................................................... 19 5.7 Restricted bands of operation .......................................................................................... 20 6 Test results ............................................................................................................................. 21 6.1 AC power line conducted emissions 150 kHz to 30 MHz ................................................. 22 6.2 20 dB bandwidth .............................................................................................................. 26 6.3 Emissions outside the operating frequency band(s) specified .......................................... 28 7 Equipment calibration status ................................................................................................... 35 8 Measurement uncertainties .................................................................................................... 36 9 Revision history ...................................................................................................................... 37 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID Reader LFM Reader 4x 190752-AU01+W01 Page 4 of 37 List of figures Figure 1: Setup for AC power-line conducted emissions test from 150 kHz to 30 MHz .................. 12 Figure 2: Setup for radiated emissions test below 30 MHz ............................................................ 15 Figure 3: Setup for radiated emissions test from 30 MHz to 1 GHz ............................................... 16 Figure 4: Setup for radiated emissions test above 1 GHz .............................................................. 19 Figure 5: Chart of AC power-line conducted emissions test – phase L1 ........................................ 23 Figure 6: Final results of AC power-line conducted emissions test – phase L1 .............................. 24 Figure 7: Chart of AC power-line conducted emissions test – phase N .......................................... 24 Figure 8: Final results of AC power-line conducted emissions test – phase N ............................... 25 Figure 9: Chart of 20 dB bandwidth ............................................................................................... 27 Figure 10: Chart of emissions test below 30 MHz with tag in position X and antenna in line .......... 30 Figure 11: Final results of emissions below 30 MHz ...................................................................... 31 Figure 12: Chart of emissions test from 30 MHz to 1 GHz with tag in position X and horizontal polarization .................................................................................................................................... 34 Figure 13: Final results of emissions from 30 MHz to 1 GHz .............................…

Text truncated - open the document above for the full version.

Test Setup Photos

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex A Page 1 of 6 1 Annex A – Test setup 1.1 List of Pictures Picture 1: CDC, test setup radiated emission test 9 kHz -30 MHz (front view) .................. 2 Picture 2: CDC, test setup radiated emission test 9 kHz -30 MHz (back view) .................. 2 Picture 3: SAC, radiated emission test 30 MHz -1 GHz and bandwidth test (front view) ... 3 Picture 4: SAC, radiated emission test 30 MHz -1 GHz and bandwidth test (rear view) .... 3 Picture 5: AC powerline measurement .............................................................................. 4 Picture 6: EUT-position X .................................................................................................. 4 Picture 7: EUT-position Y .................................................................................................. 5 Picture 8: EUT-position Z ................................................................................................... 5 Picture 9: Used power supply for EUT ............................................................................... 6 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex A Page 2 of 6 Picture 1: CDC, test setup radiated emission test 9 kHz -30 MHz (front view) Picture 2: CDC, test setup radiated emission test 9 kHz -30 MHz (back view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex A Page 3 of 6 Picture 3: SAC, radiated emission test 30 MHz -1 GHz and bandwidth test (front view) Picture 4: SAC, radiated emission test 30 MHz -1 GHz and bandwidth test (rear view) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex A Page 4 of 6 Picture 5: AC powerline measurement Picture 6: EUT-position X EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex A Page 5 of 6 Picture 7: EUT-position Y Picture 8: EUT-position Z EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany HERMOS AG RFID reader LFM Reader 4x 190752-AU01+W01 Annex A Page 6 of 6 Picture 9: Used power supply for EUT

Contact Information

Applicant

Lothar Duengfelder
[email protected]00499279991Fax: 00499279991 100

Test Firm

Element Materials Technology Straubing GmbHChristian Kiermeier
[email protected]49-9421-56868-0Fax: 49-9421-56868-100

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1342 MHz - 0.1342 MHz-
Confidentiality
Long Term
Grant Notes
This device must be professionally installed.

Other Applications from HERMOS AG

LF WIP-Regal 32x RFID kit - FCC ID 2AP5OLFM-32X - HERMOS AG
2AP5OLFM-32X

LF WIP-Regal 32x RFID kit

Feb 26, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz