Fanvil Technology Co., Ltd Covered Equipment Certification Attestation Letter 9/4/2024 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2APPZ-I60 Fanvil Technology Co., Ltd (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Fanvil Technology Co., Ltd (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Mengjiao Hu Title: Certified Engineer Company Name: Fanvil Technology Co., Ltd Date: 9/4/2024
Fanvil Technology Co., Ltd * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 9/4/2024 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2APPZ-I60 Per section 2.911(d)(7) of the FCC rules, Fanvil Technology Co., Ltd (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Federal Registration Number (FRN): 0033401829 Company Name: EMCTEK Physical U.S. Company Address: 11788 Big Canyon Ln, San Diego, CA 92131 USA Agent name: Fang Liu Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicants Federal Registration Number (FRN): 0027493469 Company Name: Fanvil Technology Co., Ltd Company Address: 10/F Block A, Dualshine Global Science Innovation Center, Honglang North 2nd Road, Bao'an District, Shenzhen, China Agent name: William Zhang Agent Email Address: [email protected] Applicant Signed: Agent Signed (if different to Applicant): Signed: Signed: Printed name: Mengjiao Hu Printed name: Fang Liu Title: Certified Engineer Title: Manager Company Name: Fanvil Technology Co., Ltd Company Name: EMCTEK Date: 9/4/2024 Date: 9/4/2024
Fanvil Technology Co., Ltd Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: Sep. 4, 2024 SUBJECT: FCC Application for FCC ID: 2APPZ-I60 To Whom It May Concern: We, the undersigned, hereby authorize _Totti Zhao at CTC Laboratories, Inc. and Stan Li at Shenzhen Sonoff Technologies Co.,Ltd. on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by _Totti Zhao, Stan Li_ on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Signature: Name: Mengjiao Hu Company: Fanvil Technology Co., Ltd Address: 10/F Block A, Dualshine Global Science Innovation Center, Honglang North 2nd Road, Bao'an District, Shenzhen, China Phone: +8675526402199 Fax: / Email: [email protected]
Fanvil Technology Co., Ltd Date: Sep. 4, 2024 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID:__ 2APPZ-I60 ____ Product Name:__ Video Door Phone ____ Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...) • Schematics • Block Diagram • Operation Description • Bom These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. In addition we hereby request the following exhibits contained in this application to be temporarily (short-term confidentiality) withheld from the public disclosure ☒ for an initial period of 180 days ☐ until: ☐ not applicable ☒ External Photos ☒ Test Setup Photos ☒ Internal Photos ☒ User’s Manual Signature: Name: Mengjiao Hu Company: Fanvil Technology Co., Ltd Address: 10/F Block A, Dualshine Global Science Innovation Center, Honglang North 2nd Road, Bao'an District, Shenzhen, China Phone: +8675526402199 Fax: / Email: [email protected]
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel: +86-755-27521059 Fax: +86-755-27521011 http://www.sz-ctc.org.cn Page 1 of 2 Label CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel: +86-755-27521059 Fax: +86-755-27521011 http://www.sz-ctc.org.cn Page 2 of 2 Label Location 1.
东莞市一佳电子通讯科技有限公司 Dongguan YiJia Electronics Communication Technology Co.,Ltd. 规格承认书 SPECIFICATION FOR APPROVAL 日期 Date 2024/05/22 编号 File No 24052202 版本 Revision 1.0 客户 CUSTOMER: 方位 客户料号 CUSTOMER NO: LEAEA100015A0 品名 NFC Antenna 品名 PART NAME: NFC Antenna 供方料号 SUPPLIER NO: YJL01.106.067.302A 送样日期 Date: 送样数量Q‘TY: 客户确认CUSTOMER APPROVED BY APPROVALCHIEFSUPERVISOR 供方确认SUPPLIER SIGNATURE APPROVALCHECKDESIGN add:东莞市长安镇沙头社区木鱼路59号元富工业区 Tel:0769-82586086 Fax:0769-82586086 add: Yuanfu Industrial Zone, No. 59, Muyu Road, Shatou Community, Chang'an Town, Dongguan APPROVALCHECKDESIGN ChenGuoqiangXieLiChenXingyi YJ-RD-F04-A 承认书项目表 NO . 内容 (Contents) 页数 (Number of Page) 页码 (Page Code) 1 承认书封面(Spec Cover) 11 承认书封面(p) 2 承认书项目表(Spec Item ) 12 3 工程成品图(Drawing) 13 4 天线装配图(Antenna Profile) 34 ~ 6 5 材质证明(Material Certificate ) 317 ~ 37 6 RoHS报告(RoHS Test Report ) **** 7N/AN/AN/A 8- -- 99--- 10--- 11--- add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 12--- 13--- DC 6 REV. E 4 5 3 2 1 CDE 7 8 DESCRIPTION DATE B B A 8 6 7 5 4 A 1 2 3 NO PART NAME DESCRIPTION 1 Q.TY 1 A 2024-04-01 Material Part Number SCALE: 1/1 UNITS: mmREVISION: B PART NAME: APPROVED BY Tolerance X.XX X.X X° ±3° ±0.50 ±0.15 PART NO.: CHECKED BY DESIGNED BY 廖光喜 DATE: 2024-06-21 CUSTOMER PART NO 6.3*5.7*1.8mm White Conncter CON100XXA.P01 NFC Antenna FPC 37.6*29.4mm FPC FPC11XXXA.P01 东莞市一佳电子通讯科技有限公司 Dongguan YiJia Electronics Communication Technology Co.,Ltd. Tel :0769-8 2586086 Fax:0769-8 2586086 2 1 周颖杰 何清军 YJL01.106.067.302A 首次发行 B 1 O.D.0.9mm Red Electronic Wire O.D.0.9mm COA100XXA.P01 1 O.D.0.9mm Black Electronic Wire O.D.0.9mm COA100XXA.P01 34 YJ-i60-NFC-V01 37.6 29.4 1 2 3 4 35.0±3.0 Ø0.9 黑色电子线 Ø0.9 红色电子线 6.3 5.7 2024-06-21 修改线长,改成双绞线 DeviceDevice add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 NFC Antenna add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 NFC Antenna add:东莞市长安镇沙头社区木鱼路59号元富工业区Tel:0769-82586086 Fax:0769-82586086 Antenna Gain:0dBi PSM-800FSDM-A/SMH-800 , 安 全 資 料 表 1 版權 2021-01-10 First, chemical products and materials for business Chemical name: PSM-800FSDM-A/SMH-800 liquid solid plate ink Other names: Use and restricted use of construction: flexible printed circuit board (PI/Cu), hand machine roof board Name, address and address of the creator, entrant or supplier: Creator: Yueli Reachability Co., Ltd. Address: No.22 Jingjian Fourth Road, Guanyin District, Taoyuan City: 886-3- 4836651 Urgent/true: 886-3-4836651, true: 886-3-4837487 Second, the hazard identification of resources and materials Hazard classification of chemical products: Health and environmental hazards: Acute toxicity (swallowing) 4, rot/skin irritation 2, heavy weight/eye irritation 2, skin Pass sensitive substance first, carcinogenic substance second, and hazardous substance second (acute toxicity). Indication of content: S y m b o l n u m b e r : Warning language: Warning hazard warning interest: Harmful to swallow Cause skin irritation Causing severe eye irritation may cause skin hypersensitivity and suspected carcinogenesis Toxic to aquatic organisms Hazard prevention measures: Put the container in a place with good ventilation far away from the high temperature Do not eat or drink when using Remove the blindfold/face mask immediately when your clothes are contaminated If you touch your eyes, wash them with plenty of water immediately, and then ask the mud to wear suitable gloves Do not inhale gas/gas/steam gas/gas before use Place it in the upper lock Do not place until you know all safety precautions Avoid releasing release in the environment Other hazards:- III. Composition identification of PSM-800FSDM-A/SMH-800 , 安 全 資 料 表 2 版權 2021-01-10 capital mixture: Liquid solid plate ink PSM-800FSDM-A/SMH-800 Chemical geology: Chinese and English names of hazardous components Register number of Chemical Digest Service (CAS No.) Degree or degree (percentage of components) Oxygen acrylate oligmer Epoxy acrylate oligmer 28064-14-4 50% Silicon dioxide Fused silica 7631-86-9 13% Aromatic solution 64742-94-5 4% PSM-800FSDM-A/SMH-800 , 安 全 資 料 表 3 版權 2021-01-10 Methyl dipropylene glycol 34590-94-8 4% Carbon black 1333-86-4 3.5% BaSO4 sulfate 13462-86-7 24% Photoinitiator and the others 5495-84-1 1.5% Fourth, first aid measures First aid methods for the same road: Inhalation: 1. Take self-protection measures before rescue. 2. Remove pollution sources or move patients to new places. 3. If a patient stops breathing, artificial respiration should be given immediately by the person who has been adalmed. If the heart stops, cardiopulmonary resuscitation should be given. When the patient inhales and swallows toxic substances, mouth-to-mouth artificial respiration should be used directly, and pocket masks and other medical equipment should be used for artificial respiration. 4. Maintain the patient's safety and normal temperature. 6. Treat the cure quickly. Pi Mo: Wash the contaminated area with harmonious water for at least 20 minutes, and remove contaminated clothes, shoes and leather products before water. Eye touching: Immediately open the eyelids and wash the contaminated eyes with water for at least 20 minutes, and immediately take care of them. Intake: 1. If the patient will be frustrated, or has been frustrated, he can feed anything. 2. It can induce vomiting and give 240-300ml of water. 3. If you vomit spontaneously, rinse your mouth and supply water repeatedly. The most important diseases and harmful effects:- Protection against first aid workers:- Tips for doctors:- V. Fire measures Suitable for fire: chemical dry powder, wine foam, carbon dioxide, water, fire: water, water, foam water. Special hazards that may be encountered during fire; 1. Its steam gas and decomposition products are burning and toxic. 2. Its steam gas is heavier than its empty gas, and it can spread to distant fire sources and give birth to tempering. 3. The combination of steam and big gas may lead to explosion. 4. When this object is indoors, outdoors or in s…
Text truncated - open the document above for the full version.
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel: +86-755-27521059 Fax: +86-755-27521011 http://www.sz-ctc.com.cn CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn RF Exposure Evaluation FCC ID: 2APPZ-I60 According to KDB447498 D01 General RF Exposure Guidance v06, Clause 4.3.1(a) EUT Specification Product Name: Video Door Phone Trade Mark: Model/Type reference: i60 Listed Model(s): / Frequency band (Operating) BT: 2.402GHz ~ 2.480GHz BLE: 2.402GHz ~ 2.480GHz WLAN: 2.412GHz ~ 2.462GHz Others _13.56MHz__ Device category Portable (<5mm separation) Mobile (>20cm separation) Fixed (>20cm separation) Others ___ Antenna diversity Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Antenna gain (Max) BLE: 3.7dBi NFC:0dBi Page 2 of 3 Report No.: CTC2024200207 CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn Limit Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) (A) Limits for Occupational/Controlled Exposure 300-1500 -- -- F/300 <6 1500-100000 -- -- 5 <6 (B) Limits for General Population/Uncontrolled Exposure 300-1500 -- -- F/1500 <30 1500-100000 -- -- 1 <30 Calculation Method Friis transmission formula: Pd=(P out *G)/(4*Pi*R 2 ) Where: Pd= Power density in mW/cm 2 P out = output power to antenna in mW G= gain of antenna in linear scale Pi= 3.1416 R= distance between observation point and center of the radiator in cm Pd limit of MPE is 1mW/cm 2 . If we know the maximum gain of the antenna and total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached. Measurement Result Mode Frequency (MHz) Antenna Gain (dBi) Maximum Power (dBm) Tune Up Tolerance (dB) Max. Tune Up Power (dBm) Power Density at 20cm (mW/cm 2 ) Limit (mW/cm 2 ) BLE 1M 2402 3.7 5.17 ±1 6 0.00186 1 NFC: eirp = pt x gt = (E x d) 2 /30 where: pt = transmitter output power in watts, gt = numeric gain of the transmitting antenna (unitless), E = electric field strength in V/m, --- 10 ((dBuV/m)/20) /10 6 d = measurement distance in meters (m), --- 3m So pt = (E x d) 2 /(30 x gt) 13.56MHz Field strength = 52.53 dBuV/m @3m Ant gain 0dBi, Ant numeric gain = 1 So pt = {[10 (52.53/20) /10 6 ×3] 2 /(30×1)}×1000 mW = 0.0000537 mW Per § 1.1307(b)(3)(i)(A), a single RF source is exempt RF device if the available maximum time-averaged power is no more than 1 mW, regardless of separation distance. Page 3 of 3 Report No.: CTC2024200207 CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn Note: 1. BLE and NFC can be launched simultaneously. Simultaneous evaluation of compliant RF exposur: 0.00186/1+0.0000537/1=0.0019137<1 2. Calculate by Worst-case mode. 2. Max. Tune Up Power by Manufacturer's Declaration, and Max. Tune Up Power is used to calculate. 3. For a more detailed features description, please refer to the RF Test Report. **********************THE END**********************
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel: +86-755-27521059 Fax: +86-755-27521011 http://www.sz-ctc.org.cn TEST REPORT Report No. .................................... : CTC2024200206 FCC ID ........................................... : 2APPZ-I60 Applicant ...................................... : Fanvil Technology Co., Ltd Address...................................: 10/F Block A, Dualshine Global Science Innovation Center, Honglang North 2nd Road, Bao'an District, Shenzhen, China Manufacturer..................................: Fanvil Technology Co., Ltd Address..........................................: 10/F Block A, Dualshine Global Science Innovation Center, Honglang North 2nd Road, Bao'an District, Shenzhen, China Product Name .............................. : Video Door Phone Trade Mark .................................... : Model/Type reference .................... : i60 Listed Model(s) .............................. : / Standard ....................................... : FCC Rules Part 15.225 Date of receipt of test sample......: Aug. 27, 2024 Date of testing..........................: Aug. 27, 2024 ~ Aug. 31, 2024 Date of issue............................: Sep. 03, 2024 Result....................................: PASS Compiled by: (Printed name + signature) Lucy Lan Supervised by: (Printed name + signature) Eric Zhang Approved by: (Printed name + signature) Totti Zhao $英文检测章$ $Totti$ This test report may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by CTC. The test results in the report only apply to the tested sample. The test report shall be invalid without all the signatures of testing engineers, reviewer and approver. Any objections must be raised to CTC within 15 days since the date when the report is received. It will not be taken into consideration beyond this limit. The test report merely correspond to the test sample. Page 2 of 28 Report No.: CTC2024200206 CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn Table of Contents Page 1. TEST SUMMARY ......................................................................................................................................... 3 1.1. TEST STANDARDS ................................................................................................................................................. 3 1.2. REPORT VERSION ................................................................................................................................................. 3 1.3. TEST DESCRIPTION ............................................................................................................................................... 3 1.4. TEST FACILITY ...................................................................................................................................................... 4 1.5. MEASUREMENT UNCERTAINTY ............................................................................................................................... 4 1.6. ENVIRONMENTAL CONDITIONS ............................................................................................................................... 5 1.7. EUT OPERATION STATE ......................................................................................................................................... 5 2. GENERAL INFORMATION ............................................................................................................................ 6 2.1. CLIENT INFORMATION ........................................................................................................................................... 6 2.2. GENERAL DESCRIPTION OF EUT ............................................................................................................................. 6 2.3. ACCESSORY EQUIPMENT INFORMATION ................................................................................................................... 7 2.4. MEASUREMENT INSTRUMENTS LIST ........................................................................................................................ 8 3. TEST ITEM AND RESULTS ............................................................................................................................ 9 3.1. CONDUCTED EMISSION ......................................................................................................................................... 9 3.2. RADIATED EMISSION ........................................................................................................................................... 12 3.3. BANDWIDTH ..................................................................................................................................................... 21 3.4. FIELD STRENGTH OF THE FUNDAMENTAL ................................................................................................................ 23 3.5. FREQUENCY STABILITY......................................................................................................................................... 26 3.6. ANTENNA REQUIREMENT .................................................................................................................................... 28 Page 3 of 28 Report No.: CTC2024200206 CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |
Portable Wi-Fi Phone
Equipment Class
NII - Unlicensed National Information Infrastructure TXVideo Door Phone
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
IP Phone
Equipment Class
DTS - Digital Transmission System
Portable Wi-Fi Phone
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Portable Wi-Fi Phone
Equipment Class
DTS - Digital Transmission System