FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Brilliant Home Technology Inc/
  3. 2APQV-BCPUSMG

2APQV-BCPUSMGBrilliant Control 4-Switch Panel

Brilliant Home Technology Inc

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 17, 2024
Application Purpose
Original Equipment
Date of Application
Apr 17, 2024
Equipment Note
Brilliant Control 4-Switch Panel
Frequency Range
2412.00000000 - 2462.00000000
Company
Brilliant Home Technology Inc
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

CFR 47 §2.911(d)(5)(i) Attestation Letter Attestation Letter Date: 02/12/2024 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID: 2APQV-BCPUSMG Brilliant Home Technology Inc (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Contact Person: Brian Cardanha Title: VP, Hardware Engineering Company Name & Address: Brilliant Home Technology Inc 155 Bovet Road, Suite 500 San Mateo, CA 94402, USA

Attestation Statements

CFR 47 §2.911 (d)(5)(ii) Attestation Letter Attestation Letter Date: 02/12/2024 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID: 2APQV-BCPUSMG Brilliant Home Technology Inc (“the applicant”) certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Contact Person: Brian Cardanha Title: VP, Hardware Engineering Company Name & Address: Brilliant Home Technology Inc 155 Bovet Road, Suite 500 San Mateo, CA 94402, USA

Attestation Statements

Attestation Letter for Agent 2024/02/12 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements Part 2.911 (d)(7) Filing FCC ID: 2APQV-BCPUSMG Brilliant Home Technology Inc certifies that, as of the date of the filing of the application, Brilliant Home Technology Inc is our designated U.S. agent for service of process for the above referenced FCC ID: 2APQV-BCPUSMG. Brilliant Home Technology Inc agrees to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Brilliant Home Technology Inc accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company name: Brilliant Home Technology Inc (FRN: 0027502764) Address: 155 Bovet Rd., Suite 500, San Mateo CA 94402, United States Contact person: Brian Cardanha Tel: (650)-539-5320 Email: [email protected] Sincerely, Applicant Name Brilliant Home Technology Inc Applicant Printed Name Brian Cardanha Applicant Signature

Cover Letter(s)

QA-FR-170-B 7/29/2014 FCC Authorization 01/10/2024 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We Brilliant Home Technology Inc, the undersigned, hereby authorizes Bay Area Compliance Laboratories Corp. to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Brian Cardanha VP, Hardware Engineering [email protected] 650-539-5320

Cover Letter(s)

QA-FR-172-A FCC Confidential Authorization 2024/02/12 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2APQV -BCPUSMG In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Brilliant Home Technology Inc hereby requests long-term confidential treatment of information accompanying this application as outlined below: •Block Diagram •Schematics •Operation Description As well as short-term (180 days) confidential treatment of information accompanying this application as outlined below: •Internal Photos •User’s Manual •External Photos •Test Set-up Photos The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Brian Cardanha VP, Hardware Engineering Brilliant Home Technology Inc [email protected] 650-539-5320 • U-NII Device Security Declaration

Cover Letter(s)

DECLARATION OF SIMILARITY February 8, 2024 To: FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Innovation, Science and Economic Development Canada Certification and Engineering Bureau P.O. Box 11490, Station ‘H’ 3701 Carling Ave., Building 94 Ottawa, Ontario K2H 8S2 Canada Dear Sir or Madam: We Brilliant Home Technology Inc hereby declare that product: Brilliant Control Panels, the 2- Switch Panel and 3-Switch Panel, models: BCP120US-WH2 and BCP120US-WH3 (FCC ID: 2APQV-BCPUSMG, IC: 23875-BCPCAMG) are electrically identical with the same electromagnetic emissions and electromagnetic compatibility characteristics as the 4-Switch Panel, model: BCP120US-WH4 tested by BACL, the results of which are featured in BACL project: R2310194. A description of the differences between the tested model and those that are declared similar are as follows: - Plastic housing size - Number of touch elements for controlling lights (Two for 2-Switch panel, three for 3- Switch panel, and four for the 4-Switch panel) Please contact me should there be need for any additional clarification or information. Best Regards, Brian Cardanha VP, Hardware Engineering Brilliant Home Technology Inc 155 Bovet Road, Suite 500 San Mateo, CA 94402, USA

ID Label/Location Info

Model: BCP120US-WH2 Model: BCP120US-WH3 Model: BCP120US-WH4 EUT

RF Exposure Info

Brilliant Home Technology Inc. FCC ID: 2APQV-BCPUSMG IC: 23875-BCPCAMG Report Number: R2310194-247 DTS Page 17 of 76 FCC Part 15C/ISEDC RSS-247 Report 5 FCC §15.247(i) §2.1091 & ISED RSS-102 - RF Exposure 5.1 Applicable Standards As per FCC §1.1310(d) (3), At operating frequencies above 6 GHz, the MPE limits listed in Table 1 in paragraph (e)(1) of this section shall be used in all cases to evaluate the environmental impact of human exposure to RF radiation as specified in §1.1307(b) of this part. TABLE 1 TO §1.1310(E)(1)—LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (i) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *(100) ≤6 3.0-30 1842/f 4.89/f *(900/f 2 ) <6 30-300 61.4 0.163 1.0 <6 300-1,500 f/300 <6 1,500-100,000 5 <6 (ii) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *(100) <30 1.34-30 824/f 2.19/f *(180/f 2 ) <30 30-300 27.5 0.073 0.2 <30 300-1,500 f/1500 <30 1,500-100,000 1.0 <30 f = frequency in MHz. * = Plane-wave equivalent power density. Brilliant Home Technology Inc. FCC ID: 2APQV-BCPUSMG IC: 23875-BCPCAMG Report Number: R2310194-247 DTS Page 18 of 76 FCC Part 15C/ISEDC RSS-247 Report 5.2 MPE Prediction Predication of MPE limit at a given distance, Equation from OET Bulletin 65, Edition 97-01 S = EIRP/4R² Where: S = power density EIRP = Effective Isotropic Radiated Power R = distance to the center of radiation of the antenna Brilliant Home Technology Inc. FCC ID: 2APQV-BCPUSMG IC: 23875-BCPCAMG Report Number: R2310194-247 DTS Page 19 of 76 FCC Part 15C/ISEDC RSS-247 Report 5.3 MPE Results for FCC Band Frequency (MHz) Antenna Gain (dBi) Maximum Power (dBm) Maximum EIRP (dBm) Maximum EIRP (mW) Power Density at 20cm (mW/cm^2) Limit (mW/cm^2) 2.4 GHz Wi-Fi 2462 1.1 20.73 21.83 152.41 0.03 1.0 5 GHz Wi-Fi 5825 4.77 17.78 22.55 179.89 0.04 1.0 BLE 2402 1.8 12.56 14.36 27.29 0.01 1.0 5.4 RF exposure evaluation exemption for IC 2.4 GHz Wi-Fi The EIRP of this device is 21.83 dBm (152.41 mW) which is less than the exemption threshold, i.e., 1.31*10^(- 2) * f^(0.6834)=2.72W. Therefore, the RF exposure evaluation is exempt. 5 GHz Wi-Fi The EIRP of this device is 22.55 dBm (179.89 mW) which is less than the exemption threshold, i.e., 1.31*10^(- 2) * f^(0.6834)=4.9W. Therefore, the RF exposure evaluation is exempt. BLE The EIRP of this device is 14.36 dBm (27.29mW) which is less than the exemption threshold, i.e., 1.31*10^(-2) * f^(0.6834)=2.68W. Therefore, the RF exposure evaluation is exempt.

Test Report

Annex A ‐ Occupied Bandwidth Naming Convention: Radio Type (BLE, WiFi)_Frequency (MHz)_Wi-Fi Bandwidth (MHz)_Configuration (b/g/n-mode, 1/2 MBit)_ Measurement (-6dB, 99 percent)_Antenna (Ant A, Ant B, Ant BLE) BLE_2480MHz_1MBit_-6dB_Ant BLEBLE_2480MHz_1MBit_99 percent_Ant BLE BLE_2480MHz_2MBit_-6dB_Ant BLEBLE_2480MHz_2MBit_99 percent_Ant BLE BLE_2402MHz_1MBit_-6dB_Ant BLEBLE_2402MHz_1MBit_99 percent_Ant BLE BLE_2402MHz_2MBit_-6dB_Ant BLEBLE_2402MHz_2MBit_99 percent_AntBLE BLE_2440MHz_1MBit_-6dB_Ant BLEBLE_2440MHz_1MBit_99 percent_Ant BLE BLE_2440MHz_2MBit_-6dB_Ant BLEBLE_2440MHz_2MBit_99 percent_Ant BLE WIFI_2452MHz_40MHz_n-mode_-6dB_Ant AWIFI_2452MHz_40MHz_n-mode_-6dB_Ant B WIFI_2452MHz_40MHz_n-mode_99 percent_Ant A WIFI_2452MHz_40MHz_n-mode_99 percent_Ant B WIFI_2462MHz_20MHz_b-mode_-6dB_Ant AWIFI_2462MHz_20MHz_b-mode_-6dB_Ant B WIFI_2462MHz_20MHz_b-mode_99 percent_Ant A WIFI_2462MHz_20MHz_b-mode_99 percent_Ant B WIFI_2462MHz_20MHz_g-mode_-6dB_Ant AWIFI_2462MHz_20MHz_g-mode_-6dB_Ant B WIFI_2462MHz_20MHz_g-mode_99 percent_Ant A WIFI_2462MHz_20MHz_g-mode_99 percent_Ant B WIFI_2462MHz_20MHz_n-mode_-6dB_Ant AWIFI_2462MHz_20MHz_n-mode_-6dB_Ant B WIFI_2462MHz_20MHz_n-mode_99 percent_Ant A WIFI_2462MHz_20MHz_n-mode_99 percent_Ant B WIFI_2412MHz_20MHz_b-mode_-6dB_Ant AWIFI_2412MHz_20MHz_b-mode_-6dB_Ant B WIFI_2412MHz_20MHz_b-mode_99 percent_Ant A WIFI_2412MHz_20MHz_b-mode_99 percent_Ant B WIFI_2412MHz_20MHz_g-mode_-6dB_Ant AWIFI_2412MHz_20MHz_g-mode_-6dB_Ant B WIFI_2412MHz_20MHz_g-mode_99 percent_Ant A WIFI_2412MHz_20MHz_g-mode_99 percent_Ant B WIFI_2412MHz_20MHz_n-mode_-6dB_Ant AWIFI_2412MHz_20MHz_n-mode_-6dB_Ant B WIFI_2412MHz_20MHz_n-mode_99 percent_Ant A WIFI_2412MHz_20MHz_n-mode_99 percent_Ant B WIFI_2422MHz_40MHz_n-mode_-6dB_Ant AWIFI_2422MHz_40MHz_n-mode_-6dB_Ant B WIFI_2422MHz_40MHz_n-mode_99 percent_Ant A WIFI_2422MHz_40MHz_n-mode_99 percent_Ant B WIFI_2437MHz_20MHz_b-mode_-6dB_Ant AWIFI_2437MHz_20MHz_b-mode_-6dB_Ant B WIFI_2437MHz_20MHz_b-mode_99 percent_Ant A WIFI_2437MHz_20MHz_b-mode_99 percent_Ant B WIFI_2437MHz_20MHz_g-mode_-6dB_Ant AWIFI_2437MHz_20MHz_g-mode_-6dB_Ant B WIFI_2437MHz_20MHz_g-mode_99 percent_Ant A WIFI_2437MHz_20MHz_g-mode_99 percent_Ant B WIFI_2437MHz_20MHz_n-mode_-6dB_Ant AWIFI_2437MHz_20MHz_n-mode_-6dB_Ant B WIFI_2437MHz_20MHz_n-mode_99 percent_Ant A WIFI_2437MHz_20MHz_n-mode_99 percent_Ant B WIFI_2437MHz_40MHz_n-mode_-6dB_Ant AWIFI_2437MHz_40MHz_n-mode_-6dB_Ant B WIFI_2437MHz_40MHz_n-mode_99 percent_Ant A WIFI_2437MHz_40MHz_n-mode_99 percent_Ant B

Test Report

Annex B ‐ Output Power Naming Convention: Radio Type (BLE, Wi-Fi)_Frequency (MHz)_Wi-Fi Bandwidth (MHz)_Configuration (b/g/n-mode, 1/2 MBit)_Antenna (Ant A, Ant B, Ant BLE) BLE_2480MHz_1Mbit_Ant BLEBLE_2480MHz_2MBit_Ant BLE BLE_2402MHz_1MBit_Ant BLEBLE_2402MHz_2MBit_Ant BLE BLE_2440MHz_1MBit_Ant BLEBLE_2440MHz_2MBit_Ant BLE WIFI_2452MHz_40MHz_n-mode_Ant AWIFI_2452MHz_40MHz_n-mode_Ant B WIFI_2462MHz_20MHz_b-mode_Ant AWIFI_2462MHz_20MHz_b-mode_Ant B WIFI_2462MHz_20MHz_g-mode_Ant AWIFI_2462MHz_20MHz_g-mode_Ant B WIFI_2462MHz_20MHz_n-mode_Ant AWIFI_2462MHz_20MHz_n-mode_Ant B WIFI_2412MHz_20MHz_b-mode_Ant AWIFI_2412MHz_20MHz_b-mode_Ant B WIFI_2412MHz_20MHz_g-mode_Ant AWIFI_2412MHz_20MHz_g-mode_Ant B WIFI_2412MHz_20MHz_n-mode_Ant AWIFI_2412MHz_20MHz_n-mode_Ant B WIFI_2422MHz_40MHz_n-mode_Ant AWIFI_2422MHz_40MHz_n-mode_Ant B WIFI_2437MHz_20MHz_b-mode_Ant AWIFI_2437MHz_20MHz_b-mode_Ant B WIFI_2437MHz_20MHz_g-mode_Ant AWIFI_2437MHz_20MHz_g-mode_Ant B WIFI_2437MHz_20MHz_n-mode_Ant AWIFI_2437MHz_20MHz_n-mode_Ant B WIFI_2437MHz_40MHz_n-mode_Ant AWIFI_2437MHz_40MHz_n-mode_Ant B

Test Report

Annex C ‐ Spectral Density Naming Convention: Radio Type (BLE, Wi-Fi)_Frequency (MHz)_Wi-Fi Bandwidth (MHz)_Configuration (b/g/n-mode, 1/2 MBit)_ Antenna (Ant A, Ant B, Ant BLE) BLE_2480MHz_1MBit_Ant BLEBLE_2480MHz_2MBit_Ant BLE BLE_2402MHz_1MBit_Ant BLEBLE_2402MHz_2MBit_Ant BLE BLE_2440MHz_1MBit_Ant BLEBLE_2440MHz_2MBit_Ant BLE WIFI_2452MHz_40MHz_n-mode_Ant AWIFI_2452MHz_40MHz_n-mode_Ant B WIFI_2462MHz_20MHz_b-mode_Ant AWIFI_2462MHz_20MHz_b-mode_Ant B WIFI_2462MHz_20MHz_g-mode_Ant AWIFI_2462MHz_20MHz_g-mode_Ant B WIFI_2462MHz_20MHz_n-mode_Ant AWIFI_2462MHz_20MHz_n-mode_Ant B WIFI_2412MHz_20MHz_b-mode_Ant AWIFI_2412MHz_20MHz_b-mode_Ant B WIFI_2412MHz_20MHz_g-mode_Ant AWIFI_2412MHz_20MHz_g-mode_Ant B WIFI_2412MHz_20MHz_n-mode_Ant AWIFI_2412MHz_20MHz_n-mode_Ant B WIFI_2422MHz_40MHz_n-mode_Ant AWIFI_2422MHz_40MHz_n-mode_Ant B WIFI_2437MHz_20MHz_b-mode_Ant AWIFI_2437MHz_20MHz_b-mode_Ant B WIFI_2437MHz_20MHz_g-mode_Ant AWIFI_2437MHz_20MHz_g-mode_Ant B WIFI_2437MHz_20MHz_n-mode_Ant AWIFI_2437MHz_20MHz_n-mode_Ant B WIFI_2437MHz_40MHz_n-mode_Ant AWIFI_2437MHz_40MHz_n-mode_Ant B

Test Report

Annex D - dBc Naming Convention: Radio Type (BLE, Wi-Fi)_Frequency (MHz)_Wi-Fi Bandwidth (MHz)_Configuration (b/g/n-mode, 1/2 MBit)_ Measurement (30MHz-10GHz, 10-26GHz, Band Edge)_Antenna (Ant A, Ant B, Ant BLE) BLE_2480MHz_1MBit_10-26GHz_Ant BLE BLE_2480MHz_1MBit_30MHz-10GHz_Ant BLE BLE_2480MHz_1MBit_Upper Band Edge_Ant BLE BLE_2480MHz_2MBit_10-26GHz_Ant BLE BLE_2480MHz_2MBit_30MHz-10GHz_Ant BLE BLE_2480MHz_2MBit_Upper Band Edge_Ant BLE BLE_2402MHz_1MBit_10-26GHz_Ant BLE BLE_2402MHz_1MBit_30MHz-10GHz_Ant BLE BLE_2402MHz_1MBit_Lower Band Edge_Ant BLE BLE_2402MHz_2MBit_10-26GHz_Ant BLE BLE_2402MHz_2MBit_30MHz-10GHz_Ant BLE BLE_2402MHz_2MBit_Lower Band Edge_Ant BLE BLE_2440MHz_1MBit_10-26GHz_Ant BLE BLE_2440MHz_1MBit_30MHz-10GHz_Ant BLE BLE_2440MHz_2MBit_10-26GHz_Ant BLE BLE_2440MHz_2MBit_30MHz-10GHz_Ant BLE WIFI_2452MHz_40MHz_n-mode_10-26GHz_Ant A WIFI_2452MHz_40MHz_n-mode_10-26GHz_Ant B WIFI_2452MHz_40MHz_n-mode_30MHz- 10GHz_Ant A WIFI_2452MHz_40MHz_n-mode_30MHz- 10GHz_Ant B WIFI_2452MHz_40MHz_n-mode_Upper Band Edge_Ant A WIFI_2452MHz_40MHz_n-mode_Upper Band Edge_Ant B WIFI_2462MHz_20MHz_b-mode_10-26GHz_Ant A WIFI_2462MHz_20MHz_b-mode_10-26GHz_Ant B WIFI_2462MHz_20MHz_b-mode_30MHz- 10GHz_Ant A WIFI_2462MHz_20MHz_b-mode_30MHz- 10GHz_Ant B WIFI_2462MHz_20MHz_b-mode_Upper Band Edge_Ant A WIFI_2462MHz_20MHz_b-mode_Upper Band Edge_Ant B WIFI_2462MHz_20MHz_g-mode_10-26GHz_Ant A WIFI_2462MHz_20MHz_g-mode_10-26GHz_Ant B WIFI_2462MHz_20MHz_g-mode_30MHz- 10GHz_Ant A WIFI_2462MHz_20MHz_g-mode_30MHz- 10GHz_Ant B WIFI_2462MHz_20MHz_g-mode_Upper Band Edge_Ant A WIFI_2462MHz_20MHz_g-mode_Upper Band Edge_Ant B WIFI_2462MHz_20MHz_n-mode_10-26GHz_Ant A WIFI_2462MHz_20MHz_n-mode_10-26GHz_Ant B WIFI_2462MHz_20MHz_n-mode_30MHz- 10GHz_Ant A WIFI_2462MHz_20MHz_n-mode_30MHz- 10GHz_Ant B WIFI_2462MHz_20MHz_n-mode_Upper Band Edge_Ant A WIFI_2462MHz_20MHz_n-mode_Upper Band Edge_Ant B WIFI_2412MHz_20MHz_b-mode_10-26GHz_Ant A WIFI_2412MHz_20MHz_b-mode_10-26GHz_Ant B WIFI_2412MHz_20MHz_b-mode_30MHz- 10GHz_Ant A WIFI_2412MHz_20MHz_b-mode_30MHz- 10GHz_Ant B WIFI_2412MHz_20MHz_b-mode_Lower Band Edge_Ant A WIFI_2412MHz_20MHz_b-mode_Lower Band Edge_Ant B WIFI_2412MHz_20MHz_g-mode_10-26GHz_Ant A WIFI_2412MHz_20MHz_g-mode_10-26GHz_Ant B WIFI_2412MHz_20MHz_g-mode_30MHz- 10GHz_Ant A WIFI_2412MHz_20MHz_g-mode_30MHz- 10GHz_Ant B WIFI_2412MHz_20MHz_g-mode_Lower Band Edge_Ant A WIFI_2412MHz_20MHz_g-mode_Lower Band Edge_Ant B WIFI_2412MHz_20MHz_n-mode_10-26GHz_Ant A WIFI_2412MHz_20MHz_n-mode_10-26GHz_Ant B WIFI_2412MHz_20MHz_n-mode_30MHz- 10GHz_Ant A WIFI_2412MHz_20MHz_n-mode_30MHz- 10GHz_Ant B WIFI_2412MHz_20MHz_n-mode_Lower Band Edge_Ant A WIFI_2412MHz_20MHz_n-mode_Lower Band Edge_Ant B WIFI_2422MHz_40MHz_n-mode_10-26GHz_Ant A WIFI_2422MHz_40MHz_n-mode_10-26GHz_Ant B WIFI_2422MHz_40MHz_n-mode_30MHz- 10GHz_Ant A WIFI_2422MHz_40MHz_n-mode_30MHz- 10GHz_Ant B WIFI_2422MHz_40MHz_n-mode_Lower Band Edge_Ant A WIFI_2422MHz_40MHz_n-mode_Lower Band Edge_Ant B WIFI_2437MHz_20MHz_b-mode_10-26GHz_Ant A WIFI_2437MHz_20MHz_b-mode_10-26GHz_Ant B WIFI_2437MHz_20MHz_b-mode_30MHz- 10GHz_Ant A WIFI_2437MHz_20MHz_b-mode_30MHz- 10GHz_Ant B WIFI_2437MHz_20MHz_g-mode_10-26GHz_Ant A WIFI_2437MHz_20MHz_g-mode_10-26GHz_Ant B WIFI_2437MHz_20MHz_g-mode_30MHz- 10GHz_Ant A WIFI_2437MHz_20MHz_g-mode_30MHz- 10GHz_Ant B WIFI_2437MHz_20MHz_n-mode_10-26GHz_Ant A WIFI_2437MHz_20MHz_n-mode_10-26GHz_Ant B WIFI_2437MHz_20MHz_n-mode_30MHz- 10GHz_Ant A WIFI_2437MHz_20MHz_n-mode_30MHz- 10GHz_Ant B WIFI_2437MHz_40MHz_n-mode_10-26GHz_Ant A WIFI_2437MHz_40MHz_n-mode_10-26GHz_Ant B WIFI_2437MHz_40MHz_n-mode_30MHz- 10GHz_Ant A WIFI_2437MHz_40MHz_n-mode_30MHz- 10GHz_Ant B

Test Report

Annex E ‐ 15.209 Band Edges Naming Convention: Radio Type (BLE, Wi-Fi)_Frequency (MHz)_Wi-Fi Bandwidth (MHz)_Configuration (b/g/n-mode, 1/2 MBit)_ Measurement (Avg, Peak)_Antenna(Ant A, Ant B, Ant BLE) Note: below measurements are in units of dBuV/m at 3meters. These measurements are performed conducted in lieu of radiated as permitted by ANSI C63.10-2013. The following formula was used in making such conversions: Above 1GHz: E[dBμV/m] = EIRP[dBm] - 20 log (d[m]) + 104.77, where E is field strength and d is distance at which the field strength limit is specified in the applicable requirements. E[dBμV/m] = EIRP[dBm] + 95.2, for d = 3 m. Straight conversion between E[dBuV/m] and EIRP[dBm} = 107. Thus offset for dBuV/m at 3meters is 95.2-107+antenna gain. Below 1GHz: above is true in addition to adding ground plane contribution of 4.7dB. thus offset for dBuV/m at 3meters is 95.2-107+4.7+antenna gain. BLE_2480MHz_1MBit_ Avg_Ant BLEBLE_2480MHz_1MBit_ Peak_Ant BLE BLE_2480MHz_2MBit_ Avg_Ant BLEBLE_2480MHz_2MBit_ Peak_Ant BLE BLE_2402MHz_1MBit_ Avg_Ant BLEBLE_2402MHz_1MBit_ Peak_Ant BLE BLE_2402MHz_2MBit_ Avg_Ant BLEBLE_2402MHz_2MBit_ Peak_Ant BLE WIFI_2452MHz_40MHz_n-mode_ Avg_Ant AWIFI_2452MHz_40MHz_n-mode_ Avg_Ant B WIFI_2452MHz_40MHz_n-mode_ Peak_Ant A WIFI_2452MHz_40MHz_n-mode_ Peak_Ant B WIFI_2462MHz_20MHz_b-mode_ Avg_Ant AWIFI_2462MHz_20MHz_b-mode_ Avg_Ant B WIFI_2462MHz_20MHz_b-mode_ Peak_Ant A WIFI_2462MHz_20MHz_b-mode_ Peak_Ant B WIFI_2462MHz_20MHz_g-mode_ Avg_Ant AWIFI_2462MHz_20MHz_g-mode_ Avg_Ant B WIFI_2462MHz_20MHz_g-mode_ Peak_Ant A WIFI_2462MHz_20MHz_g-mode_ Peak_Ant B WIFI_2462MHz_20MHz_n-mode_ Avg_Ant AWIFI_2462MHz_20MHz_n-mode_ Avg_Ant B WIFI_2462MHz_20MHz_n-mode_ Peak_Ant A WIFI_2462MHz_20MHz_n-mode_ Peak_Ant B WIFI_2412MHz_20MHz_b-mode_ Avg_Ant AWIFI_2412MHz_20MHz_b-mode_ Avg_Ant B WIFI_2412MHz_20MHz_b-mode_ Peak_Ant A WIFI_2412MHz_20MHz_b-mode_ Peak_Ant B WIFI_2412MHz_20MHz_g-mode_ Avg_Ant AWIFI_2412MHz_20MHz_g-mode_ Avg_Ant B WIFI_2412MHz_20MHz_g-mode_ Peak_Ant A WIFI_2412MHz_20MHz_g-mode_ Peak_Ant B WIFI_2412MHz_20MHz_n-mode_ Avg_Ant AWIFI_2412MHz_20MHz_n-mode_ Avg_Ant B WIFI_2412MHz_20MHz_n-mode_ Peak_Ant A WIFI_2412MHz_20MHz_n-mode_ Peak_Ant B WIFI_2422MHz_40MHz_n-mode_ Avg_Ant AWIFI_2422MHz_40MHz_n-mode_ Avg_Ant B WIFI_2422MHz_40MHz_n-mode_ Peak_Ant A WIFI_2422MHz_40MHz_n-mode_ Peak_Ant B

Test Report

Annex F - 15.209 Conducted Naming Convention: Radio Type (BLE, Wi-Fi)_Frequency (MHz)_Wi-Fi Bandwidth (MHz)_Configuration (b/g/n-mode, 1/2 MBit)_ Measurement (Avg, Peak)_Antenna (Ant A, Ant B, Ant BLE) Note: below measurements are in units of dBuV/m at 3meters. These measurements are performed conducted in lieu of radiated as permitted by ANSI C63.10-2013. The following formula was used in making such conversions: Above 1GHz: E[dBμV/m] = EIRP[dBm] - 20 log (d[m]) + 104.77, where E is field strength and d is distance at which the field strength limit is specified in the applicable requirements. E[dBμV/m] = EIRP[dBm] + 95.2, for d = 3 m. Straight conversion between E[dBuV/m] and EIRP[dBm} = 107. Thus offset for dBuV/m at 3meters is 95.2-107+antenna gain. Below 1GHz: above is true in addition to adding ground plane contribution of 4.7dB. thus offset for dBuV/m at 3meters is 95.2-107+4.7+antenna gain. BLE_2480MHz_1MBit_30-1000MHz_Peak_Ant BLE BLE_2480MHz_2MBit_30-1000MHz_Peak_Ant BLE BLE__2402MHz_1MBit_30-1000MHz_Peak_Ant BLE BLE__2402MHz_2MBit_30-1000MHz_Peak_Ant BLE BLE__2440MHz_1MBit_30-1000MHz_Peak_Ant BLE BLE__2440MHz_2MBit_30-1000MHz_Peak_Ant BLE WIFI_2452MHz_40MHz_n-mode_15.209_30- 1000MHz_Peak_Ant A WIFI_2452MHz_40MHz_n-mode_15.209_30- 1000MHz_Peak_Ant B WIFI_2462MHz_20MHz_b-mode_15.209_30- 1000MHz_Peak_Ant A WIFI_2462MHz_20MHz_b-mode_15.209_30- 1000MHz_Peak_Ant B WIFI_2462MHz_20MHz_g-mode_15.209_30- 1000MHz_Peak_Ant A WIFI_2462MHz_20MHz_g-mode_15.209_30- 1000MHz_Peak_Ant B WIFI_2462MHz_20MHz_n-mode_15.209_30- 1000MHz_Peak_Ant A WIFI_2462MHz_20MHz_n-mode_15.209_30- 1000MHz_Peak_Ant B WIFI_2412MHz_20MHz_b-mode_15.209_30- 1000MHz_Peak_Ant A WIFI_2412MHz_20MHz_b-mode_15.209_30- 1000MHz_Peak_Ant B WIFI_2412MHz_20MHz_g-mode_15.209_30- 1000MHz_Peak_Ant A WIFI_2412MHz_20MHz_g-mode_15.209_30- 1000MHz_Peak_Ant B WIFI_2412MHz_20MHz_n-mode_15.209_30- 1000MHz_Peak_Ant A WIFI_2412MHz_20MHz_n-mode_15.209_30- 1000MHz_Peak_Ant B WIFI_2422MHz_40MHz_n-mode_15.209_30- 1000MHz_Peak_Ant A WIFI_2422MHz_40MHz_n-mode_15.209_30- 1000MHz_Peak_Ant B WIFI_2437MHz_20MHz_b-mode_15.209_30- 1000MHz_Peak_Ant A WIFI_2437MHz_20MHz_b-mode_15.209_30- 1000MHz_Peak_Ant B WIFI_2437MHz_20MHz_g-mode_15.209_30- 1000MHz_Peak_Ant A WIFI_2437MHz_20MHz_g-mode_15.209_30- 1000MHz_Peak_Ant B WIFI_2437MHz_20MHz_n-mode_15.209_30- 1000MHz_Peak_Ant A WIFI_2437MHz_20MHz_n-mode_15.209_30- 1000MHz_Peak_Ant B WIFI_2437MHz_40MHz_n-mode_15.209_30- 1000MHz_Peak_Ant A WIFI_2437MHz_40MHz_n-mode_15.209_30- 1000MHz_Peak_Ant B BLE_2480MHz_1MBit_1-26GHz_Peak_Ant BLE BLE_2480MHz_1MBit_1-26GHz_Avg_Ant BLE BLE_2480MHz_2MBit_1-26GHz_Peak_Ant BLE BLE_2480MHz_2MBit_1-26GHz_Avg_Ant BLE BLE_2402MHz_1MBit_1-26GHz_Peak_Ant BLE BLE_2402MHz_1MBit_1-26GHz_Avg_Ant BLE BLE_2402MHz_2MBit_1-26GHz_Peak_Ant BLE BLE_2402MHz_2MBit_1-26GHz_Avg_Ant BLE BLE_2440MHz_1MBit_1-26GHz_Peak_Ant BLE BLE_2440MHz_1MBit_1-26GHz_Avg_Ant BLE BLE_2440MHz_2MBit_1-26GHz_Peak_Ant BLE BLE_2440MHz_2MBit_1-26GHz_Avg_Ant BLE WIFI_2452MHz_40MHz_n-mode_Peak_Ant A WIFI_2452MHz_40MHz_n-mode_Peak_Ant B WIFI_2452MHz_40MHz_n-mode_Avg_Ant A WIFI_2452MHz_40MHz_n-mode_Avg_Ant B WIFI_2462MHz_20MHz_b-mode_Peak_Ant A WIFI_2462MHz_20MHz_b-mode_Peak_Ant B WIFI_2462MHz_20MHz_b-mode_Avg_Ant A WIFI_2462MHz_20MHz_b-mode_Avg_Ant B WIFI_2462MHz_20MHz_g-mode_Peak_Ant A WIFI_2462MHz_20MHz_g-mode_Peak_Ant B WIFI_2462MHz_20MHz_g-mode_Avg_Ant A WIFI_2462MHz_20MHz_g-mode_Avg_Ant B WIFI_2462MHz_20MHz_n-mode_Peak_Ant A WIFI_2462MHz_20MHz_n-mode_Peak_Ant B WIFI_2462MHz_20MHz_n-mode_Avg_Ant A WIFI_2462MHz_20MHz_n-mode_Avg_Ant B WIFI_2412MHz_20MHz_b-mode_Peak_Ant A WIFI_2412MHz_20MHz_b-mode_Peak_Ant B WIFI_2412MHz_20MHz_b-mode_Avg_Ant A WIFI_2412MHz_20MHz_b-mode_Avg_Ant B WIFI_2412MHz_20MHz_g-mode_Peak_Ant A WIFI_2412MHz_20MHz_g-mode_Peak_Ant B WIFI_2412MHz_20MHz_g-mode_Avg_Ant A WIFI_2412MHz_20MHz_g-mode_Avg_Ant B WIFI_2412MHz_20MHz_n-mode_Peak_Ant A WIFI_2412MHz_20MHz_n-mode_Peak_Ant B WIFI_2412MHz_20MHz_n-mode_Avg_Ant A WIFI_2412MHz_20MHz_n-mode_Avg_Ant B WIFI_2422MHz_40MHz_n-mode_Peak_Ant A WIFI_2422MHz_40MHz_n-mode_Peak_Ant B WIFI_2422MHz_40MHz_n-mode_Avg_Ant A WIFI_2422MHz_40MHz_n-mode_Avg_Ant B WIFI_2437MHz_20MHz_b-mode_Peak_Ant A WIFI_2437MHz_20MHz_b-mode_Peak_Ant B WIFI_2437MHz_20MHz_b-mode_Avg_Ant A WIFI_2437MHz_20MHz_b-mode_Avg_Ant B WIFI_2437MHz_20MHz_g-mode_Peak_Ant A WIFI_2437MHz_20MHz_g-mode_Peak_Ant B WIFI_2437MHz_20MHz_g-mode_Avg_Ant A WIFI_2437MHz_20MHz_g-mode_Avg_Ant B WIFI_2437MHz_20MHz_n-mode_Peak_Ant A WIFI_2437MHz_20MHz_n-mode_Peak_Ant B WIFI_2437MHz_20MHz_n-mode_Avg_Ant A WIFI_2437MHz_20MHz_n-mode_Avg_Ant B WIFI_2437MHz_40MHz_n-mode_Peak_Ant A WIFI_2437MHz_40MHz_n-mode_Peak_Ant B WIFI_2437MHz_40MHz_n-mode_Avg_Ant A WIFI_2437MHz_40MHz_n-mode_Avg_Ant B

Test Report

Note: This test report was prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This test report shall not be used by the customer to claim product certification, approval, or endorsement by A2LA or any agency of the United States Government or any foreign government. * This test report may contain data and test methods that are not covered by BACL’s scope of accreditation as of the test report date shown above. These items are marked within the test report text with an asterisk “*” \ FCC PART 15, SUBPART C ISEDC RSS-247, ISSUE 3, AUGUST 2023 TEST REPORT For Brilliant Home Technology Inc. 155 Bovet Road Suite 500 San Mateo, CA 94402, USA FCC ID: 2APQV-BCPUSMG IC: 23875-BCPCAMG R e p o r t T y p e : O r i gi n a l R e p o r t P r o d u c t T y p e : C o n t r o l P a n e l Prepared By: Michael Papa RF Test Engineer Report Number: R2310194-247 DTS Report Date: 2024-03-20 Reviewed By: Christian McCaig RF Lead Engineer Bay Area Compliance Laboratories Corp. 1274 Anvilwood Avenue, Sunnyvale, CA 94089, USA Tel: (408) 732-9162 Fax: (408) 732-9164 Brilliant Home Technology Inc. FCC ID: 2APQV-BCPUSMG IC: 23875-BCPCAMG Report Number: R2310194-247 DTS Page 2 of 76 FCC Part 15C/ISEDC RSS-247 Report TABLE OF CONTENTS 1 General Description ..................................................................................................................................................... 5 1.1 Product Description for Equipment Under Test (EUT) ...................................................................................... 5 1.2 Objective ............................................................................................................................................................. 5 1.3 Mechanical Description of EUT ......................................................................................................................... 5 1.4 Related Submittal(s)/Grant(s) ............................................................................................................................. 5 1.5 Test Methodology ............................................................................................................................................... 6 1.6 Measurement Uncertainty ................................................................................................................................... 6 1.7 Test Facility Registrations .................................................................................................................................. 6 1.8 Test Facility Accreditations ................................................................................................................................ 6 2 System Test Configuration.......................................................................................................................................... 9 2.1 Justification ......................................................................................................................................................... 9 2.2 EUT Exercise Software....................................................................................................................................... 9 2.3 Duty Cycle Correction Factor ........................................................................................................................... 10 2.4 Equipment Modification ................................................................................................................................... 14 2.5 Local Support Equipment ................................................................................................................................. 14 2.6 Remote Support Equipment .............................................................................................................................. 14 2.7 Interface Ports and Cabling ............................................................................................................................... 14 3 Summary of Test Results ............................................................................................................................................ 15 4 FCC §15.203 & ISEDC RSS-Gen §6.8 - Antenna Requirements ............................................................................ 16 4.1 Applicable Standards ........................................................................................................................................ 16 4.2 Antenna Description ......................................................................................................................................... 16 5 FCC §15.247(i) §2.1091 & ISED RSS-102 - RF Exposure ....................................................................................... 17 5.1 Applicable Standards ........................................................................................................................................ 17 5.2 MPE Prediction ................................................................................................................................................. 18 5.3 RF exposure evaluation exemption for FCC ..................................................................................................... 19 5.4 MPE Results for IC ........................................................................................................................................... 19 6 FCC §15.207 & ISEDC RSS-Gen §8.8 - AC Line Conducted Emissions ................................................................ 20 6.1 Applicable Standards ........................................................................................................................................ 20 6.2 Test Setup .......................................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Brian Cardanha(VP, Hardware Engineering)
[email protected]650-539-5320Fax: N/A

Test Firm

Bay Area Compliance Laboratories Corp.Lisa Tang
[email protected]408-732-9162Fax: 408 732 9164

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz118.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.

Other Applications from Brilliant Home Technology Inc

BLE transceiver - FCC ID 2APQV-BHS120US - Brilliant Home Technology Inc
2APQV-BHS120US

BLE transceiver

Jun 18, 2020

Equipment Class

DTS - Digital Transmission System
Smart Plug - FCC ID 2APQV-BHP120 - Brilliant Home Technology Inc
2APQV-BHP120

Smart Plug

Apr 08, 2020

Equipment Class

DTS - Digital Transmission System