10.1“Tablet Model:100011886 PRODUCT GUIDE We ‘d love to hear from you. Scan with your Walmart app and let us know what you think. May 12, 2020_V1 618 1 1 3 1 3 1 1 3 1 Introduction Thank you for purchasing the Android 10(Go edition) tablet with Google Play. Featuring a fast and responsive quad core processor, this tablet is perfect for accomplishing everyday tasks, streaming music and movies, taking photos, checking emails, and engaging with social media. The tablet oers 32GB of internal storage, Bluetooth connectivity, Micro SD slot for up to 128GB of additional storage, on-the-go productivity services. The following information will help you get the most out of your tablet. What You Should Know to Ensure Best Performance: Charge the battery completely before first use. While updates download in the background, tablet performance can be aected until completed. Close unused applications. Open apps that run in the background will aect overall performance. Battery Consumption: Play times on a fully charged battery will vary depending on your display settings, apps that remain open, and internet use (e.g.,streaming video content). It is recommended to use a tablet screen protector and tablet case to protect the tablets. 2 3 In The Box 10.1" tablet USB-C cable size:61*41*24mm Input: 100-240V~50/60Hz,0.3A Output:5.0V 2.0A Charger User Manual 10.1“Tablet Quick Start Guide Quick Start Guide 10.1“Tablet Model:100011886 PRODUCT GUIDE We ‘d love to hear from you. Scan with your Walmart app and let us know what you think. May 12, 2020_V1 618 1 1 3 1 3 1 1 3 1 4 1. Camera (Rear) 2. Reset 3. Power On/o 4. Volume Control 5. USB-C Port 6. Micro SD Slot 7. Earphone 8. Speakers 9. Camera (Front) 5 Starting Your Tablet 1. Press and hold the Power button for 3~4 seconds. (If your tablet does not turn on, or instructs you to "Connect your charger" , connect the AC adapter and charge the unit.) 2. At the Start-up screen, swipe up from the bottom of the screen to unlock. 3. Once you' ve arrived at the Home screen, you can begin using your tablet. Home Screen At-a-Glance 6 1. Status Bar 2. Search Box 3. Walmart App Suite 4. Go Back 5. Home 6. Recents 7 Using the Cameras Tap on the Camera lcon 1.Switch Cameras (Front/Rear) 2.Camera Settings 3.Recent Photo 4.Take Photo 8 Tablet Updates To ensure the tablet runs smoothly it is recommended to perform periodic system software updates, especially during initial set up of the tablet. You may receive notifications (on the Lock screen) from time to time that software updates are available. Tap the notification to be directed to the update. Other options to access updates: Tap on Settings > About Tablet >Wireless Update. NOTE: To perform an update, you must be connected to WiFi. 9 Google Play Updates The first time you sign on to Google Play Store, updates will automatically start downloading on to the tablet.The download icon will appear in the status bar at the top left of screen. Installing a new application while multiple apps are downloading will reduce tablet speed and performance. After all downloads and updates have been installed, the tablet will resume normal operating performance. To view the progress of downloads working in the background, swipe down from the top edge of the screen. 10 Touching and Typing To select an item on the screen, simply tap it once with your fingertip. Some items may require you to "double-tap”. To type in to a text field (i .e., when inputting your name , or a web address), tap the text field. The on-screen keyboard will appear, and allow you to type the information you wish to enter. Touch and Hold: Keep your finger on an on-screen item until it glows or activates an alternate menu. Drag: Move an App or object by touching and holding the image, then moving it to the destination. Slide: When there are extra "screens" to the side, slide one or more fingers from one side to another. 11 Connecting to the Internet Wireless Router In order to connect to the internet, you will need the following: A wireless router or an access point with a broadband internet connection. The name of your network (SSID), as well as the password or other credentials, if your network is secure. The wireless router must support WiFi 802.11 a/b/g/n/ac connections. Go to SETTINGS > Network & internet > WiFi Tap on WiFi to activate wireless connectivity. The Tablet will scan for available WiFi networks within range. Secured networks will require a password. Once you have successfully entered your information the tablet will remember your settings. 12 Connecting Bluetooth Your Tablet is compatible with Bluetooth capable devices. Once your tablet searches and finds the Bluetooth device, follow on-screen instructions to initiate the pairing of the device with the Tablet. Add or "pair" a Bluetooth compatible device with your Tablet as follows: 1) Turn on the compatible Bluetooth device and make it discoverable. 2) Open the Settings > Connected devices. 3) Tap on Pair new device to view available devices. 13 Charging Your Tablet It is recommended to fully charge the tablet before first use. To charge the tablet, 1) plug the USB cable into the AC adapter, 2) attach the other end to the USB-C input on the tablet, 3) plug the AC adapter into a wall outlet. When the tablet is ON and charging, the battery icon will pulsate. A complete battery charge may take up to 3 hours. It is normal for the tablet to get warm while charging, playing games, or streaming video. Battery life will vary depending on usage. Note: Leave tablet in a well ventilated area while charging. 14 Important Safety Instructions 1.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 2.WARNING:Only use attachments/accessories specified or provided by the manufacturer(such as the exclusive supply adapter, battery etc). 3.WARNING:The mains plug should be kept in a state that can be disconnected at anytime to avoid eme…
Text truncated - open the document above for the full version.
C5266091.)(10_Ed.1 Hunan Greatwall Computer System Co.,Ltd O仔ice of Engin四ring Technol og y Federal Commu nications Commissio『1 7435 Oakland Mills R。“ Columbia, MD 21046 Date: 5/15/2020 5u均ect: Reque筑币or臼nfidentiality FC C ID : 2APUQW1027 T o Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commiss ion's rules ( 47CFR0.457, 0.459), we are requ眠,ng the Commission to withhold the following a忧achment(s) as ronfid ential document from public disclosure. Exhi时也Lor咱·Term9、ort·Term Confldentlalltv c。nfi世ntlalitv ID Label/Location No No Attestation Statement No N。 External Photos No t」J B比比KDlaaram 因i [JI Schematics 因J口j Test Reo。rt No No T田tSetuoPhotos N。 口j U田r's Mam且l D J UJ Internal Photos DJ L」 l Parts List I Tune Uo 口」口 RF Ex。但ureInf,。 口l 口j Ooeratior旧lDescriotion 因j口j Cover L时terfslNo No SDR Softwa陪IS配川tv Inf,。 凶l No Above mention创docu町、entcontains detail创systemand equipment description are considered as proprietary information in operation of the伺uiprr随时.The public di sc i 。sureof above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all m臼sure町、enttest reports , 民主ID label format and correspondent during certification review process cannot be grant·创as confidential documents and those information will be available for public review once the grant of equipment authorizatio『1 is issued. 5incerely, Signature: � Name:Kelvin Wang Tit隐:Manager 1/1
FCCID:2APUQW1027 ESTTechnologyCo.,LtdReportNo.ESTE-R2004043Page1of4 ExternalPhotos M/N:100011886 FCCID:2APUQW1027 ESTTechnologyCo.,LtdReportNo.ESTE-R2004043Page2of4 ExternalPhotos M/N:100011886 FCCID:2APUQW1027 ESTTechnologyCo.,LtdReportNo.ESTE-R2004043Page3of4 ExternalPhotos M/N:100011886 FCCID:2APUQW1027 ESTTechnologyCo.,LtdReportNo.ESTE-R2004043Page4of4 PowerSupply
FCC ID: 2APUQW1027 EST Technology Co., LtdReport No. ESTE-R2004043Page 1 of 6 Internal Photos M/N: 100011886 FCC ID: 2APUQW1027 EST Technology Co., LtdReport No. ESTE-R2004043Page 2 of 6 Internal Photos M/N: 100011886 FCC ID: 2APUQW1027 EST Technology Co., LtdReport No. ESTE-R2004043Page 3 of 6 Internal Photos M/N: 100011886 FCC ID: 2APUQW1027 EST Technology Co., LtdReport No. ESTE-R2004043Page 4 of 6 Internal Photos M/N: 100011886 FCC ID: 2APUQW1027 EST Technology Co., LtdReport No. ESTE-R2004043Page 5 of 6 Internal Photos M/N: 100011886 Mainboard Model No.: RS512M32LM4D2BDS-53BT 2GB & EMMC32G-TA28 32GB FCC ID: 2APUQW1027 EST Technology Co., LtdReport No. ESTE-R2004043Page 6 of 6 Internal Photos M/N: 100011886 Mainboard Model No.: MDXC1016G-M2 2GB & LTMZ0007HF-DAB1-SM
Model: 100011886 Report No.: WTD20X04022499W Page 1 of 71 SAR Report Test Standards: FCC Part 2.1093, ANSI / IEEE C95.1 :2005+A1:2010 ANSI / IEEE C95.3 :2002(R2008) Product Description: 10.1"Android Tablet Tested Model: 100011886 Report No.: WTD20X04022499W Sample Received Date: 2020-04-29 Tested Date: 2020-04-29 to 2020-05-06 Issued Date: 2020-05-07 Tested By: Jack Sun / Engineer Reviewed By: Lion Cai / RF Manager Approved & Authorized By: Silin Chen / Manager Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Website: www.semtest.com.cn Note: This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Waltek Testing Group (Shenzhen) Co., Ltd. FCC SAR Measurement and Test Report For Hunan Greatwall Computer System CO., LTD Hunan GreatWall Industrial Park,Tianyi Science and Technology City,Xiangyun Middle Road,Tianyuan District,Zhuzhou,Hunan Model: 100011886 Report No.: WTD20X04022499W Page 2 of 71 SAR Report TABLE OF CONTENTS 1. General Information ................................................................................................................................................... 3 1.1 Product Description for Equipment Under Test (EUT) ......................................................................................... 3 1.2 Test Standards .................................................................................................................................................... 5 1.3 Test Methodology ................................................................................................................................................ 5 1.4 Test Facility ......................................................................................................................................................... 5 2. Summary of Test Results .......................................................................................................................................... 6 3. Specific Absorption Rate (SAR) ................................................................................................................................ 7 3.1 Introduction .......................................................................................................................................................... 7 3.2 SAR Definition ..................................................................................................................................................... 7 4. SAR Measurement System ........................................................................................................................................ 8 4.1 The Measurement System .................................................................................................................................. 8 4.2 Probe ................................................................................................................................................................... 8 4.3 Probe Calibration Process ................................................................................................................................. 10 4.4 Phantom ............................................................................................................................................................ 11 4.5 Device Holder .................................................................................................................................................... 11 4.6 Test Equipment List ........................................................................................................................................... 12 5. Tissue Simulating Liquids ....................................................................................................................................... 13 5.1 Composition of Tissue Simulating Liquid ........................................................................................................... 13 5.2 Tissue Dielectric Parameters for Head and Body Phantoms ............................................................................. 14 5.3 Tissue Calibration Result ................................................................................................................................... 15 6. SAR Measurement Evaluation ................................................................................................................................ 16 6.1 Purpose of System Performance Check ............................................................................................................ 16 6.2 System Setup .................................................................................................................................................... 16 6.3 Validation Results .............................................................................................................................................. 17 7. EUT Testing Position ............................................................................................................................................... 18 7.1 EUT Antenna Position ....................................................................................................................................... 18 8. SAR Measurement Procedures ............................................................................................................................... 20 8.1 Measurement Procedures ................................................................................................................................. 20 8.2 Spatial Peak SAR Evaluation ............................................................................................................................ 20 8.3 Area & Zoom Scan Procedur…
Text truncated - open the document above for the full version.
Ref : ACR.233.1.17.SATU.A SHENZHEN SEM TEST TECHNOLOGY CO., LTD. 1/F, BUILDING A, HONGWEI INDUSTRIAL PARK, LIUXIAN 2ND ROAD BAO'AN DISTRICT SHENZHEN (518101), CHINA MVG COMOSAR DOSIMETRIC E-FIELD PROBE SERIAL NO.: SN 45/15 EPGO280 Calibrated at MVG US 2105 Barrett Park Dr. - Kennesaw, GA 30144 Calibration Date: 07/08/2019 Summary: This document presents the method and results from an accredited COMOSAR Dosimetric E-Field Probe calibration performed in MVG USA using the CALISAR / CALIBAIR test bench, for use with a COMOSAR system only. All calibration results are traceable to national metrology institutions. COMOSAR E-Field Probe Calibration Report COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.233.1.17.SATU.A Page: 2/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Name Function Date Signature Prepared by : Jérôme LUC Product Manager 7/8/2019 Checked by : Jérôme LUC Product Manager 7/8/2019 Approved by : Kim RUTKOWSKI Quality Manager 7/8/2019 Customer Name Distribution : Shenzhen SEM.Test Technology Co., Ltd. Issue Date Modifications A 7/8/2019 Initial release COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.233.1.17.SATU.A Page: 3/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. TABLE OF CONTENTS 1 Device Under Test ..................................................................................................... 4 2 Product Description ................................................................................................... 4 2.1 General Information _______________________________________________________ 4 3 Measurement Method ................................................................................................ 4 3.1 Linearity ________________________________________________________________ 4 3.2 Sensitivity _______________________________________________________________ 5 3.3 Lower Detection Limit _____________________________________________________ 5 3.4 Isotropy _________________________________________________________________ 5 3.5 Boundary Effect __________________________________________________________ 5 4 Measurement Uncertainty .......................................................................................... 5 5 Calibration Measurement Results .............................................................................. 6 5.1 Sensitivity in air __________________________________________________________ 6 5.2 Linearity ________________________________________________________________ 7 5.3 Sensitivity in liquid ________________________________________________________ 7 5.4 Isotropy _________________________________________________________________ 8 6 List of Equipment .................................................................................................... 10 COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.233.1.17.SATU.A Page: 4/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 1 DEVICE UNDER TEST Device Under Test Device Type COMOSAR DOSIMETRIC E FIELD PROBE Manufacturer MVG Model SSE2 Serial Number SN 45/15 EPGO280 Product Condition (new / used) New Frequency Range of Probe 0.7 GHz-6GHz Resistance of Three Dipoles at Connector Dipole 1: R1=0.193 M Dipole 2: R2=0.188 M Dipole 3: R3=0.198 M A yearly calibration interval is recommended. 2 PRODUCT DESCRIPTION 2.1 GENERAL INFORMATION MVG’s COMOSAR E field Probes are built in accordance to the IEEE 1528, OET 65 Bulletin C and CEI/IEC 62209 standards. Figure 1 – MVG COMOSAR Dosimetric E field Dipole Probe Length 330 mm Length of Individual Dipoles 2 mm Maximum external diameter 8 mm Probe Tip External Diameter 2.5 mm Distance between dipoles / probe extremity 1 mm 3 MEASUREMENT METHOD The IEEE 1528, OET 65 Bulletin C, CENELEC EN50361 and CEI/IEC 62209 standards provide recommended practices for the probe calibrations, including the performance characteristics of interest and methods by which to assess their affect. All calibrations / measurements performed meet the fore mentioned standards. 3.1 LINEARITY The evaluation of the linearity was done in free space using the waveguide, performing a power sweep to cover the SAR range 0.01W/kg to 100W/kg. COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.233.1.17.SATU.A Page: 5/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 3.2 SENSITIVITY The sensitivity factors of the three dipoles were determined using a two step calibration method (air and tissue simulating liquid) using waveguides as outlined in the standards. 3.3 LOWER DETECTION LIMIT The lower detection limit was assessed using the same measurement set up as used for the linearity measurement. The required lower detection limit is 10 mW/kg. 3.4 ISOTROPY The axial isotropy was evaluated by exposing the probe to a reference wave from a standard dipole with the dipole mounted under the flat phantom in the test configuration suggested for system validations and checks. The probe was rotated along its main axis from 0 - 360 degrees in 15 degree steps. The hemispherical isotropy is determined by inserting the probe in a thin plastic box filled with tissue-equivalent liquid, with the plastic box …
Text truncated - open the document above for the full version.
FCC ID: 2APUQW1027 EST Technology Co., Ltd Report No.ESTE-R2004045 Page 1 of 143 FCC PART 15E TEST REPORT FOR CERTIFICATION On Behalf of Hunan Greatwall Computer System Co.,Ltd 10.1" Android Tablet Model Number: 100011886 FCC ID: 2APUQW1027 Prepared for: Hunan Greatwall Computer System Co.,Ltd Hu'nan Greatwall Industrial Park,Xiangyun Middle Rd., Tianyuan Dist.,Zhuzhou, Hu'nan Prepared By: EST Technology Co., Ltd. Chilingxiang, Qishantou, Santun, Houjie, Dongguan, Guangdong, China Tel: 86-769-83081888-808 Report Number: ESTE-R2004045 Date of Test: Apr. 15~May. 14, 2020 Date of Report: May. 15, 2020 FCC ID: 2APUQW1027 EST Technology Co., Ltd Report No.ESTE-R2004045 Page 2 of 143 TABLE OF CONTENTS Description Page TEST REPORT VERIFICATION ........................................................................................................................ 3 1. GENERAL INFORMATION ................................................................................................................. 5 1.1. Description of Device (EUT) ........................................................................................................... 5 1.1. Difference between Model Numbers ................................................................................................ 6 1.2. The antenna information for EUT .................................................................................................... 6 2. SUMMARY OF TEST ......................................................................................................................... 7 2.1. Summary of test result ...................................................................................................................... 7 2.2. Test Facilities .................................................................................................................................... 8 2.3. Measurement uncertainty for EST Technology Co., Ltd. ................................................................ 9 2.4. Assistant equipment used for test ..................................................................................................... 9 2.5. Block Diagram .................................................................................................................................. 9 2.6. Test Mode ....................................................................................................................................... 10 2.7. Channel List .................................................................................................................................... 12 2.8. Power Setting of Test Software ...................................................................................................... 13 2.9. Duty Cycle of Test Signal .............................................................................................................. 14 2.10. Test Equipment List ....................................................................................................................... 18 3. 6DB BANDWIDTH &26DB BANDWIDTH & 99% OCCUPIED BANDWIDTH ..................................... 20 3.1. Limit ............................................................................................................................................... 20 3.2. Test Setup ....................................................................................................................................... 20 3.3. Spectrum Analyzer Setting ............................................................................................................. 20 3.4. Test Procedure ................................................................................................................................ 21 3.5. Test Result ...................................................................................................................................... 21 3.6. Test Result ...................................................................................................................................... 22 3.7. Test Result ...................................................................................................................................... 24 4. MAXIMUM CONDUCTED OUTPUT POWER ..................................................................................... 45 4.1. Limit ............................................................................................................................................... 45 4.2. Test Setup ....................................................................................................................................... 45 4.3. Test Procedure ................................................................................................................................ 45 4.4. Test Result ...................................................................................................................................... 46 5. PEAK POWER SPECTRAL DENSITY ................................................................................................ 48 5.1. Limit ............................................................................................................................................... 48 5.2. Test Setup ....................................................................................................................................... 48 5.3. Spectrum Analyzer Setting ............................................................................................................. 48 5.4. Test Procedure ................................................................................................................................ 48 5.5. Test Result ...................................................................................................................................... 48 6. UNWANTED EMISSIONS AND BAND EDGE ..................................................................................... 63 6.1. Limit ............…
Text truncated - open the document above for the full version.
FCC ID: 2APUQW1027 EST Technology Co.,Ltd Report No. ESTE-R2004046 Page 1 of 25 DFS TEST REPORT FOR CERTIFICATION On Behalf of Hunan Greatwall Computer System Co.,Ltd 10.1" Android Tablet Model Number: 100011886 FCC ID: 2APUQW1027 Prepared for: Hunan Greatwall Computer System Co.,Ltd Hu'nan Greatwall Industrial Park,Xiangyun Middle Rd., Tianyuan Dist.,Zhuzhou, Hu'nan Prepared By: EST Technology Co., Ltd. Chilingxiang, Qishantou, Santun, Houjie, Dongguan, Guangdong, China Tel: 86-769-83081888-808 Report Number: ESTE-R2004046 Date of Test: Apr. 15~May. 14, 2020 Date of Report: May. 15, 2020 FCC ID: 2APUQW1027 EST Technology Co.,Ltd Report No. ESTE-R2004046 Page 2 of 25 TABLE OF CONTENTS Description Page 1. GENERAL INFORMATION ........................................................................................................................ 4 1.1. Description Of Device (EUT) .................................................................................................................. 4 1.1. Difference between Model Numbers ....................................................................................................... 5 1.2. The Antenna Information For EUT ......................................................................................................... 5 2. SUMMARY OF TEST ................................................................................................................................. 6 2.1. Summary Of Test Result .......................................................................................................................... 6 2.2. Test Facilities ........................................................................................................................................... 7 2.3. Measurement Uncertainty For EST Technology Co., Ltd. ...................................................................... 8 2.4. Test Equipment List ................................................................................................................................. 9 3. EIRP POWER ........................................................................................................................................ 10 4. DYNAMIC FREQUENCY SELECTION REQUIREMENTS ............................................................................. 11 5.1. DFS Overview ....................................................................................................................................... 11 5.2. DFS Detection Thresholds ..................................................................................................................... 12 5.3. Response Requirements ......................................................................................................................... 12 5.4. Radar Test Waveforms .......................................................................................................................... 13 5.4.1. Short Pulse Radar Test Waveforms .......................................................................................... 13 5.4.2. Long Pulse Radar Test Waveform ............................................................................................ 15 5.4.3. Frequency Hopping Radar Test Waveform .............................................................................. 16 5. TEST SETUP ......................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 4 | 15E | 5.75 GHz - 5.83 GHz | 15.14 mW |

Laptop
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Personal Computer
Equipment Class
DTS - Digital Transmission System
Tablet
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterSmart Projector
Equipment Class
NII - Unlicensed National Information Infrastructure TX
LAPTOP
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter