Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
www.myyezz.com www.myyezz.com [email protected] [email protected] FCC RF EXPOSURE INFORMATION: WARNING!! Read this information before using your phone In August 1986 the Federal Communications Commission (FCC) of the United States with its action in Report and Outer FCC 96-326 adopted an updated safety standard for human exposure to radio frequency (RF) electromagnetic energy emitted by FCC regulated transmitters. Those guidelines are consistent with the safety standard previously set by both U.S. and international standards bodies. The design of this phone complies with the FCC guidelines and these international standards. Use only the supplied or an approved antenna. Unauthorized antennas modifications, or attachments could impair call quality, damage the phone, or result in violation of FCC regulations. Do not use the phone with a damaged antenna. If a damaged antenna comes into contact with the skin, a minor burn may result. Please contact your local dealer for replacement antenna. BODY-WORN OPERATION: This device was tested for typical body-worn operations with the back/front of the phone kept 5mm from the body. To comply with FCC RF exposure requirements, a minimum separation distance of 5mm must be maintained between the user's body and the back/front of the phone, including the antenna. Third-party belt-clips, holsters and similar accessories containing metallic components shall not be used. Body-worn accessories that cannot maintain 5mm separation distance between the userβs body and the back/front of the phone, and have not been tested for typical body-worn operations may not comply with FCC RF exposure limits and should be avoided. For more information about RF exposure, please visit the FCC website at www.fcc.gov Your wireless handheld portable telephone is a low power radio transmitter and receiver. When it is ON, it receives and also sends out radio frequency (RF) signals. In August, 1996, the Federal Communications Commissions (FCC) adopted RF exposure guidelines with safety levels for hand- held wireless phones. Those guidelines are consistent with the safety standards previously set by both U.S. and international standards bodies: <ANSIC95.1> (1992) / <NCRP Report 86> (1986) / <ICNIRP> (1999) Those standards were based on comprehensive and periodic evaluations of the relevant scientific literature. For example, over 120 scientists, engineers, and physicians from universities, government health agencies, and industry reviewed the available body of research to develop the ANSI Standard (C95.1). Nevertheless, we recommend that you use a hands-free kit with your phone (such as an earpiece or headset) to avoid potential exposure to RF energy. The design of your phone complies with the FCC guidelines (and those standards). Use only the supplied or an approved replacement antenna. Unauthorized antennas, modifications, or attachments could damage the phone and may violate FCC regulations. NORMAL POSITION: Hold the phone as you would any other telephone with the antenna pointed up and over your shoulder. RF Exposure Information: This product is compliance to FCC RF Exposure requirements and refers to FCC website https://apps.fcc.gov/oetcf/eas/reports/GenericSearch.cfm search for 2APW4C32 to gain further information include SAR Values. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the userβs authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the userβs authority to operate the equipment.
Bolt Modus Corp Agent Authorization Company: Bolt Modus Corp Address: Oficina N.33 Edificio Ofidepositos Central, Calidonia - Distrito Federal, Panama Product Name: Mobile phone Model Number(s): C32 Product Description: Mobile phone We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2022-11-08 Name: Giovanna Briceno Company: Bolt Modus Corp
Report No.: AGC01043220901AP02 Page 1 of 4 EXTERNAL PHOTOS All VIEW OF EUT TOP VIEW OF EUT Report No.: AGC01043220901AP02 Page 2 of 4 BOTTOM VIEW OF EUT FRONT VIEW OF EUT Report No.: AGC01043220901AP02 Page 3 of 4 BACK VIEW OF EUT LEFT VIEW OF EUT Report No.: AGC01043220901AP02 Page 4 of 4 RIGHT VIEW OF EUT ****************************************End of Report****************************************
FCC ID Label Location 20mm&15mm ο· FCC ID: 2APW4C32
Report No.: AGC01043220901AP02 Page 1 of 6 INTERNAL PHOTOS OPEN VIEW OF EUT(FIGURE 1) OPEN VIEW OF EUT(FIGURE 2) GSM&WC DMA<E Antenna Report No.: AGC01043220901AP02 Page 2 of 6 GSM ANTENNA OPEN VIEW OF EUT(FIGURE 3) Report No.: AGC01043220901AP02 Page 3 of 6 INTERNAL VIEW OF EUT(FIGURE 1) INTERNAL VIEW OF EUT(FIGURE 2) BT Antenna Report No.: AGC01043220901AP02 Page 4 of 6 INTERNAL VIEW OF EUT(FIGURE 3) INTERNAL VIEW OF EUT(FIGURE 4) Report No.: AGC01043220901AP02 Page 5 of 6 INTERNAL VIEW OF EUT(FIGURE 5) BATTERY OF EUT Report No.: AGC01043220901AP02 Page 6 of 6 ADAPTER OF EUT ****************************************End of Report****************************************
Page 1 of 97 SAR Test Report Report No.: AGC01043220901FH01 FCC ID : 2APW4C32 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Mobile phone BRAND NAME : YEZZ MODEL NAME : C32 APPLICANT : Bolt Modus Corp DATE OF ISSUE : Oct. 21,2022 STANDARD(S) : IEEE Std. 1528:2013 FCC 47 CFR Part 2Β§2.1093 IEEE Std C95.1 β’-2005 IEC 62209-1: 2016 REPORT VERSION : V1.0 Attestation of Global Compliance(Shenzhen) Co., Ltd. Report No.: AGC01043220901FH01 Page 2 of 97 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Oct. 21,2022 Valid Initial Release Report No.: AGC01043220901FH01 Page 3 of 97 Test Report Applicant Name Bolt Modus Corp Applicant Address Oficina N.33 Edificio Ofidepositos Central, Calidonia - Distrito Federal, Panama Manufacturer Name Bolt Modus Corp Manufacturer Address Oficina N.33 Edificio Ofidepositos Central, Calidonia - Distrito Federal, Panama Factory Name Bolt Modus Corp Factory Address Oficina N.33 Edificio Ofidepositos Central, Calidonia - Distrito Federal, Panama Product Designation Mobile phone Brand Name YEZZ Model Name C32 EUT Voltage DC3.7V by battery Applicable Standard IEEE Std. 1528:2013 FCC 47 CFR Part 2Β§2.1093 IEEE Std C95.1 β’-2005 IEC 62209-1: 2016 Test Date Oct. 08,2022 to Oct. 12,2022 Report Template AGCRT-US-4G/SAR (2021-04-20) Note: The results of testing in this report apply to the product/system which was tested only. Prepared By Jack Gui (Project Engineer) Oct. 12,2022 Reviewed By Calvin Liu (Reviewer) Oct. 21,2022 Approved By Max Zhang (Authorized Officer) Oct. 21,2022 Report No.: AGC01043220901FH01 Page 4 of 97 TABLE OF CONTENTS 1. SUMMARY OF MAXIMUM SAR VALUE ......................................................................................................... 5 2. GENERAL INFORMATION ............................................................................................................................... 6 2.1. EUT DESCRIPTION......................................................................................................................................... 6 3. SAR MEASUREMENT SYSTEM ........................................................................................................................ 8 3.1. THE DASY5 SYSTEM USED FOR PERFORMING COMPLIANCE TESTS CONSISTS OF FOLLOWING ITEMS .................... 8 3.2. DASY5 E-FIELD PROBE ................................................................................................................................. 9 3.3. DATA ACQUISITION ELECTRONICS DESCRIPTION ............................................................................................... 9 3.4. ROBOT ........................................................................................................................................................ 10 3.5. LIGHT BEAM UNIT ........................................................................................................................................ 10 3.6. DEVICE HOLDER .......................................................................................................................................... 11 3.7. MEASUREMENT SERVER ............................................................................................................................... 11 3.8. PHANTOM ................................................................................................................................................. 12 4. SAR MEASUREMENT PROCEDURE .............................................................................................................. 13 4.1. SPECIFIC ABSORPTION RATE (SAR) .............................................................................................................. 13 4.2. SAR MEASUREMENT PROCEDURE ................................................................................................................ 14 4.3. RF EXPOSURE CONDITIONS ......................................................................................................................... 16 5. TISSUE SIMULATING LIQUID ......................................................................................................................... 17 5.1. THE COMPOSITION OF THE TISSUE SIMULATING LIQUID..................................................................................... 17 5.2. TISSUE DIELECTRIC PARAMETERS FOR HEAD AND BODY PHANTOMS ............................................................... 18 5.3. TISSUE CALIBRATION RESULT ....................................................................................................................... 19 6. SAR SYSTEM CHECK PROCEDURE ........................................................................................................... 20 6.1. SAR SYSTEM CHECK PROCEDURES ............................................................................................................. 20 6.2. SAR SYSTEM CHECK ................................................................................................................................... 21 7. EUT TEST POSITION ...................................................................................................................................... 23 7.2. CHEEK POSITION ......................................................................................................................................... 24 7.3. TILT POSITION .............................................................................................................................................. 24 7.4. BODY WORN POSITION ................................................................................................................................ 25 8. SAR EXPOSURE LIMITS ............................................................................................................................... 26 9. TEST FACILITY ..............................................................................................................................β¦
Text truncated - open the document above for the full version.
CALIBRATION DATA PROBE CALIBRATION DATA DAE CALIBRATION DATA DIPOLE CALIBRATION DATA
Page1of 42 FCC Test Report Report No.: AGC01043220901FE07 FCC ID : 2APW4C32 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Mobile phone BRAND NAME : YEZZ MODEL NAME : C32 APPLICANT : Bolt Modus Corp DATE OF ISSUE : Oct. 24, 2022 STANDARD(S) : FCC Part 24 Rules FCC Part 27 Rules REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd. Report No.: AGC01043220901FE07 Page 2 of 42 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Oct. 24, 2022 Valid Initial Release Report No.: AGC01043220901FE07 Page 3 of 42 TABLE OF CONTENTS 1. GENERAL INFORMATION .............................................................................................................................. 5 2. PRODUCT INFORMATION .............................................................................................................................. 6 2.1 PRODUCT TECHNICAL DESCRIPTION .................................................................................................. 6 2.2 RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................... 8 2.3 TEST METHODOLOGY ............................................................................................................................ 8 2.4 DEVICE CAPABILITIES ............................................................................................................................ 8 2.5 SPECIAL ACCESSORIES ......................................................................................................................... 9 2.6 EQUIPMENT MODIFICATIONS ................................................................................................................ 9 2.7 EMISSION DESIGNATOR ......................................................................................................................... 9 3. TEST ENVIRONMENT ................................................................................................................................... 10 3.1 ADDRESS OF THE TEST LABORATORY .............................................................................................. 10 3.2 TEST FACILITY ....................................................................................................................................... 10 3.3 ENVIRONMENTAL CONDITIONS .......................................................................................................... 11 3.4 MEASUREMENT UNCERTAINTY .......................................................................................................... 11 3.5 LIST OF TEST EQUIPMENT ................................................................................................................... 12 4. SYSTEM TEST CONFIGURATION ................................................................................................................ 13 4.1 EUT CONFIGURATION ........................................................................................................................... 13 4.2 EUT EXERCISE ....................................................................................................................................... 13 4.3 CONFIGURATION OF EUT SYSTEM ..................................................................................................... 13 4.4 EQUIPMENT USED IN TESTED SYSTEM ............................................................................................ 13 5. SUMMARY OF TEST RESULTS .................................................................................................................... 14 5.1 TEST CONDITION : CONDUCTED TEST .............................................................................................. 14 5.2 TEST CONDITION : RADIATED TEST ................................................................................................... 14 6. DESCRIPTION OF TEST MODES ................................................................................................................. 15 7. CONDUCTED OUTPUT POWER ................................................................................................................... 18 7.1 PROVISIONS APPLICABLE ................................................................................................................... 18 7.2 MEASUREMENT METHOD .................................................................................................................... 18 7.3 MEASUREMENT SETUP ........................................................................................................................ 18 7.4 MEASUREMENT RESULT ...................................................................................................................... 18 8. RADIATED OUTPUT POWER ....................................................................................................................... 19 8.1 PROVISIONS APPLICABLE ................................................................................................................... 19 8.2 MEASUREMENT METHOD .................................................................................................................... 19 8.3 MEASUREMENT SETUP ........................................................................................................................ 20 Report No.: AGC01043220901FE07 Page 4 of 42 8.4 MEASUREMENT RESULT ...................................................................................................................... 22 9. PEAK-TO-AVERAGE RATIO ......................................................................................................................... 27 9.1 PROVISIONS APPLICABLE ................................................................................................................... 27 9.2 MEASUREMENT METHOD .................................................................................................................... 27β¦
Text truncated - open the document above for the full version.
Page1of 70 FCC Test Report Report No.: AGC01043220901FE08 FCC ID : 2APW4C32 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Mobile phone BRAND NAME : YEZZ MODEL NAME : C32 APPLICANT : Bolt Modus Corp DATE OF ISSUE : Oct. 24, 2022 STANDARD(S) : FCC Part 22H & 24E REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd. Report No.: AGC01043220901FE08 Page 2 of 70 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Oct. 24, 2022 Valid Initial Release Report No.: AGC01043220901FE08 Page 3 of 70 TABLE OF CONTENTS 1. GENERAL INFORMATION .............................................................................................................................. 5 2. PRODUCT INFORMATION .............................................................................................................................. 6 2.1 PRODUCT TECHNICAL DESCRIPTION .................................................................................................... 6 2.2 RELATED SUBMITTAL(S) / GRANT (S) ...................................................................................................... 8 2.3 TEST METHODOLOGY .............................................................................................................................. 8 2.4 DEVICE CAPABILITIES ............................................................................................................................... 8 2.5 SPECIAL ACCESSORIES ........................................................................................................................... 8 2.6 EQUIPMENT MODIFICATIONS .................................................................................................................. 8 2.7 EMISSION DESIGNATOR ........................................................................................................................... 9 3. TEST ENVIRONMENT ................................................................................................................................... 10 3.1 ADDRESS OF THE TEST LABORATORY ................................................................................................ 10 3.2 TEST FACILITY ......................................................................................................................................... 10 3.3 ENVIRONMENTAL CONDITIONS............................................................................................................. 11 3.4 MEASUREMENT UNCERTAINTY............................................................................................................. 11 3.5 LIST OF TEST EQUIPMENT ..................................................................................................................... 12 4. SYSTEM TEST CONFIGURATION ................................................................................................................ 14 4.1 EUT CONFIGURATION ............................................................................................................................. 14 4.2 EUT EXERCISE ......................................................................................................................................... 14 4.3 CONFIGURATION OF EUT SYSTEM ....................................................................................................... 14 4.4 EQUIPMENT USED IN TESTED SYSTEM ............................................................................................... 14 5. SUMMARY OF TEST RESULTS ................................................................................................................... 15 5.1 TEST CONDITION : CONDUCTED TEST ................................................................................................. 15 5.2 TEST CONDITION : RADIATED TEST ...................................................................................................... 15 6. DESCRIPTION OF TEST MODES ................................................................................................................. 16 7. CONDUCTED OUTPUT POWER ................................................................................................................... 18 7.1 PROVISIONS APPLICABLE ...................................................................................................................... 18 7.2 MEASUREMENT METHOD ...................................................................................................................... 18 7.3 MEASUREMENT SETUP .......................................................................................................................... 18 7.4 MEASUREMENT RESULT ........................................................................................................................ 19 8. RADIATED OUTPUT POWER ....................................................................................................................... 21 8.1 PROVISIONS APPLICABLE ...................................................................................................................... 21 8.2 MEASUREMENT METHOD ...................................................................................................................... 21 8.3 MEASUREMENT SETUP .......................................................................................................................... 22 8.4 MEASUREMENT RESULT ........................................................................................................................ 24 9. PEAK-TO-AVERAGE RATIO ......................................................................................................................... 26 Report No.: AGC01043220901FE08 Page 4 of 70 9.1 PROVISIONS APPLICABLE ...................................................................................................................... 26 9.2 MEASUREMENT METHOD ...........................................................................β¦
Text truncated - open the document above for the full version.
Report No.: AGC01043220901FE08 Page 44 of 70 PCS 1900_LCH_EDGE PCS 1900_LCH_EDGE PCS 1900_LCH_EDGE PCS 1900_LCH_EDGE PCS 1900_MCH_EDGE PCS 1900_MCH_EDGE Report No.: AGC01043220901FE08 Page 45 of 70 PCS 1900_MCH_EDGE PCS 1900_MCH_EDGE PCS 1900_HCH_EDGE PCS 1900_HCH_EDGE PCS 1900_HCH_EDGE PCS 1900_HCH_EDGE Report No.: AGC01043220901FE08 Page 46 of 70 WCDMA 850_RMC 12.2kps_LCH WCDMA 850_RMC 12.2kps_LCH WCDMA 850_RMC 12.2kps_MCH WCDMA 850_RMC 12.2kps_MCH WCDMA 850_RMC 12.2kps_HCH WCDMA 850_RMC 12.2kps_HCH Report No.: AGC01043220901FE08 Page 47 of 70 WCDMA 1900_RMC 12.2kps_LCH WCDMA 1900_RMC 12.2kps_LCH WCDMA 1900_RMC 12.2kps_LCH WCDMA 1900_RMC 12.2kps_LCH WCDMA 1900_RMC 12.2kps_MCH WCDMA 1900_RMC 12.2kps_MCH Report No.: AGC01043220901FE08 Page 48 of 70 WCDMA 1900_RMC 12.2kps_MCH WCDMA 1900_RMC 12.2kps_MCH WCDMA 1900_RMC 12.2kps_HCH WCDMA 1900_RMC 12.2kps_HCH WCDMA 1900_RMC 12.2kps_HCH WCDMA 1900_RMC 12.2kps_HCH Note:1. Below 30MHZ no Spurious found and Above is the worst mode data. 2. As no emission found in standby or receive mode, no recording in this report. Report No.: AGC01043220901FE08 Page 49 of 70 13. RADIATED SPURIOUS EMISSION 13.1. PROVISIONS APPLICABLE (A) On any frequency outside a licenseeβs frequency block (e.g. A, D, B, etc.) within the USPCS spectrum, the power of any emission shall be attenuated below the transmitter power (P, in Watts) by at least 43+10Log(P) dB. The specification that emissions shall be attenuated below the transmitter power (P) by at least 43 + 10 log (P) dB, translates in the relevant power range (1 to 0.001 W) to -13 dBm. At 1 W the specified minimum attenuation becomes 43 dB and relative to a 30 dBm (1 W) carrier becomes a limit of -13 dBm. At 0.001 W (0 dBm) the minimum attenuation is 13 dB, which again yields a limit of -13 dBm. In this way a translation of the specification from relative to absolute terms is carried out. (B) For specific criteria, please refer to the description in section 9.2 of the report for corresponding evaluation. 13.2. MEASUREMENT PROCEDURE 1. The EUT was placed on the top of the turntable 0.8 or 1.5 meter above ground. The phase center of the receiving antenna mounted on the top of a height-variable antenna tower was placed 3 meters far away from the turntable. 2. Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to determine the position of the highest radiation. 3. The height of the broadband receiving antenna was varied between one meter and four meters above ground to find the maximum emissions field strength of both horizontal and vertical polarization. 4. For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the turntable was rotated (from 0 degree to 360 degrees) to find the maximum reading. 5. Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified bandwidth under Maximum Hold Mode. 6. For emissions above 1GHz, use 1MHz VBW and RBW for peak reading. Then 1MHz RBW and 10Hz VBW for average reading in spectrum analyzer. Place the measurement antenna away from each area of the EUT determined to be a source of emissions at the specified measurement distance, while keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. The measurement antenna may have to be higher or lower than the EUT, depending on the radiation pattern of the emission and staying aimed at the emission source for receiving the maximum signal. The final measurement antenna elevation shall be that which maximizes the emissions. The measurement antenna elevation for maximum emissions shall be restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane. 7. When the radiated emissions limits are expressed in terms of the average value of the emissions, and pulsed operation is employed, the measurement field strength shall be determined by averaging over one complete pulse train, including blanking intervals, as long as the pulse train does not exceed 0.1 seconds. As an alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases where the pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the average absolute voltage during a 0.1 second interval during which the field strength is at its maximum values. 8.If the emissions level of the EUT in peak mode was 3 dB lower than the average limit specified, then testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not have 3 dB margin will be repeated one by one using the quasi-peak method for below 1GHz. Report No.: AGC01043220901FE08 Page 50 of 70 9. For testing above 1GHz, the emissions level of the EUT in peak mode was lower than average limit (that means the emissions level in peak mode also complies with the limit in average mode), then testinβ¦
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 13 | 27 | 1.72 GHz - 1.75 GHz | 156.70 mW | 18M0W7D | 2.5 ppm |

Smartphone
Equipment Class
DTS - Digital Transmission System
smart phone
Equipment Class
DTS - Digital Transmission System
smart phone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
4G Smart Phone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Tablet PC
Equipment Class
DTS - Digital Transmission System