ASAP Technology(Jiangxi) Co., Ltd. Date: 2019-12-13 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2APXNLACA118 To whom it may concern: We, the undersigned, hereby authorize SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Shenzhen Branch and Joyce Shi in SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Shenzhen Branch to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with ASAP Technology(Jiangxi) Co., Ltd. This authorization is valid until further written notice from the applicant. Print Name: Xiaolan Deng Title: Manager Signature: On behalf of Company: ASAP Technology(Jiangxi) Co., Ltd. Telephone: +86 796 7118988-38881 E-mail: [email protected]
ASAP Technology(Jiangxi) Co., Ltd. Date: 2019-12-13 To: SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: ASAP Technology(Jiangxi) Co., Ltd. Ji'an Industrial Park Ji'an, Jiangxi 343100 China Regarding: Confidentiality Request regarding application for FCC ID: 2APXNLACA118 LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic Block Diagram Operational Description The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Print Name: Xiaolan Deng Title: Manager Signature: On behalf of Company: ASAP Technology(Jiangxi) Co., Ltd. Telephone: +86 796 7118988-38881 E-mail: [email protected]
ASAP Technology(Jiangxi) Co., Ltd. Cover Letter-Wireless Charger Approval Date: 2019-12-13 Gentlemen: There’s a Foldable Desk Lamp with Wireless Charging Pad that would like to have your authorization as an Inductive wireless power transfer applications approval. The specific product as below, Foldable Desk Lamp with Wireless Charging Pad, with its designed features and specified description, meets special requirements for KDB 680106 D01 section 5.2 requirements. Company: ASAP Technology(Jiangxi) Co., Ltd. Product Name: Foldable Desk Lamp with Wireless Charging Pad Model Number: LACA118, WIAWHT100010820 FCC ID: 2APXNLACA118 KDB 680106 D01 Section 5.2 Requirements Product Technical Specification Result a) Power transfer frequency is less that 1 MHz 111.859-193.590kHz Complied b) Output power from each primary coil is less than or equal to 15 watts. 5 Watts Max Complied c) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils Complied d) Client device is placed directly in contact with the transmitter. Complied e) Mobile exposure conditions only Complied f) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Please refer to RF exposure report Complied Sincerely, Print Name: Xiaolan Deng Title: Manager Signature: On behalf of Company: ASAP Technology(Jiangxi) Co., Ltd. Telephone: +86 796 7118988-38881 E-mail: [email protected]
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 6 External Photos for SZEM1912021491CR FCC ID: 2APXNLACA118 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 6 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 6
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 6 Internal Photos for SZEM1912021491CR FCC ID: 2APXNLACA118 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 6 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 6
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 4 Setup Photos for SZEM1912021491CR FCC ID: 2APXNLACA118 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 4 1 Photographs Side 1 Side 2 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 4 Side 3 Side 4 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 4 Top 5
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202149103 Page: 1 of 8 Keny Xu EMC Laboratory Manager 1 COVER PAGE Human Exposure Report Application No.: SZEM1912021491CR Applicant: ASAP Technology (Jiangxi) Co., Ltd. Address of Applicant: Ji'an Industrial Park, Ji'an, Jiangxi, 343100 China Manufacturer: ASAP Technology (Jiangxi) Co., Ltd Address of Manufacturer: Ji’an Industrial Park, Ji’an, Jiangxi, 343100 China Factory: LUXSHARE-ICT (VIETNAM) LIMITED Address of Factory: E Lot, Quang Chau Industrial zone, Quang Chau Commune, Viet Yen district, Bac Giang Province, Vietnam Equipment Under Test (EUT): EUT Name: Foldable Desk Lamp with Wireless Charging Pad Model No.: LACA118, WIAWHT100010820 ♣ ♣ Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. Trade mark: onn. FCC ID: 2APXNLACA118 Standards: 47 CFR PART 1, Subpart I, Section 1.1310 47 CFR PART 2, Subpart J, Section 2.1091 Date of Receipt: 2019-12-23 Date of Test: 2019-12-23 to 2020-01-15 Date of Issue: 2020-01-16 Test Result : Pass* * In the configuration tested, the EUT complied with the standards specified above SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202149103 Page: 2 of 8 Revision Record Version Chapter Date Modifier Remark 01 2020-01-16 Original Authorized for issue by: Bill Chen /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202149103 Page: 3 of 8 2 Contents 1 COVER PAGE ............................................................................................................................................ 1 2 CONTENTS ................................................................................................................................................ 3 3 GENERAL INFORMATION ........................................................................................................................ 4 3.1 DETAILS OF E.U.T. ................................................................................................................................... 4 3.2 DESCRIPTION OF SUPPORT UNITS ............................................................................................................. 4 3.3 TEST LOCATION ........................................................................................................................................ 5 3.4 TEST FACILITY .......................................................................................................................................... 5 3.5 DEVIATION FROM STANDARDS ................................................................................................................... 5 3.6 ABNORMALITIES FROM STANDARD CONDITIONS.......................................................................................... 5 4 EQUIPMENTS USED DURING TEST ........................................................................................................ 6 5 TEST RESULTS ......................................................................................................................................... 7 5.1 RF EXPOSURE TEST ................................................................................................................................. 7 5.1.1 E.U.T. Operation ........................................................................................................................ 7-8 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202149103 Page: 4 of 8 3 General Information 3.1 Details of E.U.T. Power supply: AC adapter: Model:WIAWHT100010820 Input:AC 100-240V 50/60Hz 0.35A Output:DC 5V 2.4A Output 1:Wireles Charger DC 5V 1A Output 2:LED 5W Max1 Operation frequency: 111.859-193.590kHz Antenna Type: Loop Antenna Modulation Type: Load Modulation Antenna Gain: 0dBi Remark: Model No.: LACA118, WIAWHT100010820 Only the model WIAWHT100010820 was tested, since the electrical circuit design, layout, components used, internal wiring and functions were identical for all the above models, with only difference on model No.. 3.2 Description of Support Units Description Manufacturer Model No. Serial No. SAMSUNG Galaxy S8 SAMSUNG SM-G9500 R28J9140LPB SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202149103 Page: 5 of 8 3.3 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab, No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong,China 518057. Tel: +86 755 2601 2053 Fax: +86 755 2671 0594 No tests were sub-contracted. 3.4 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized by ISED as an accredited testing laboratory. CAB identifier: CN0006. IC#: 4620C. 3.5 Deviation from Standards None. 3.6 Abnormalities from Standard Con…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202149102 Page: 1 of 28 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZEM1912021491CR Applicant: ASAP Technology (Jiangxi) Co., Ltd. Address of Applicant: Ji'an Industrial Park, Ji'an, Jiangxi, 343100 China Manufacturer: ASAP Technology (Jiangxi) Co., Ltd Address of Manufacturer: Ji’an Industrial Park, Ji’an, Jiangxi, 343100 China Factory: LUXSHARE-ICT (VIETNAM) LIMITED Address of Factory: E Lot, Quang Chau Industrial zone, Quang Chau Commune, Viet Yen district, Bac Giang Province, Vietnam Equipment Under Test (EUT): EUT Name: Foldable Desk Lamp with Wireless Charging Pad Model No.: LACA118, WIAWHT100010820 Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. Trade mark: onn. FCC ID: 2APXNLACA118 Standard(s) : 47 CFR Part 15, Subpart C Date of Receipt: 2019-12-23 Date of Test: 2019-12-23 to 2020-01-15 Date of Issue: 2020-01-16 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202149102 Page: 2 of 28 Revision Record Version Chapter Date Modifier Remark 01 2020-01-16 Original Authorized for issue by: Bill Chen /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202149102 Page: 3 of 28 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C N/A 47 CFR Part 15, Subpart C 15.203 Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass 20dB Bandwidth 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.9.2 47 CFR Part 15, Subpart C 15.215 Pass Restricted Bands 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 Pass Radiated Emissions (9kHz-30MHz) 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.4 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Emissions (30MHz-1GHz) 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Remark: Model No.: LACA118, WIAWHT100010820 Only the model WIAWHT100010820 was tested, since the electrical circuit design, layout, components used, internal wiring and functions were identical for all the above models, with only difference on model No.. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202149102 Page: 4 of 28 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 TEST SUMMARY ....................................................................................................................................... 3 3 CONTENTS ................................................................................................................................................ 4 4 GENERAL INFORMATION ........................................................................................................................ 5 4.1 DETAILS OF E.U.T. ............................................................................................................................... 5 4.2 DESCRIPTION OF SUPPORT UNITS ......................................................................................................... 5 4.3 MEASUREMENT UNCERTAINTY .............................................................................................................. 5 4.4 TEST LOCATION .................................................................................................................................... 6 4.5 TEST FACILITY ...................................................................................................................................... 6 4.6 DEVIATION FROM STANDARDS ............................................................................................................... 6 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ..................................................................................... 6 5 EQUIPMENT LIST ...................................................................................................................................... 7 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................... 10 6.1 ANTENNA REQUIREMENT .................................................................................................................... 10 6.1.1 Test Requirement: ....................................................................................................................... 10 6.1.2 Conclusion ................................................................................................................................... 10 7 RADIO SPECTRUM MATTER TEST RESULTS ..................................................................................... 11 7.1 CONDUCTED EMISSIONS AT AC POWER LINE (150KHZ-30MHZ) ........................................................... 11 7.1.1 E.U.T. Operation .......................................................................................................................... 11 7.1.2 Test Setup Diagram ..................................................................................................................... 11 7.1.3 Measurement Procedure and Data............................................................................................. 12 7.2 20DB BANDWIDTH .............................................................................................................................. 15 7.2.1 E.U.T. Operation .........................................................…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 3 Setup Photos for SZEM1912021491CR FCC ID: 2APXNLACA118 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 3 1 Photographs 1.1 Conducted Emissions at AC Power Line (150kHz-30MHz) Test Setup 1.2 Radiated Emissions (9kHz-30MHz) Test Setup SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 3 1.3 Radiated Emissions (30MHz-1GHz) Test Setup
No.1 Workshop, M-10, Middle Section, Science & Tec · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.111859 MHz - 0.19359 MHz | - |
Wireless Charger Module
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzWireless charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzWireless charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Aircharge Mag
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
10W Qi Wireless Car Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz