
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
**Thick protective case 5mm or a case includes magnet or metallic material, may not allow proper charging function. 99.10 mm 139.61 m m Wireless Charging Pad Input Wireless pad output USB A output WIABLK100007907 5V/2.4A 5W 5W Dimension160mm*86mm*102mm Compatibility 1.Qi-enabled devices charge up to 5W on the pad 2.Any Qi-compatible smartphones or devices 3.Apple watch series 1, series 2, series 3, series 4, series 5. Power Barrel Connecting Port USB Port *Apple Watch charger sold separately. ** Additional ring is not included. Put the Apple Watch charger through the ring of the charging stand. Power Barrel Connector Power Barrel Connecting Port How to charge your devices. November 25, 2019_V1 Connect Apple Watch charger to the charging stand. PRODUCT GUIDE Caution Avoid dropping Do not disassemble No metal objects between devices and wireless charging stand Thick protective case ≥ 5mm or a case includes magnet or metallic material, may not allow proper charging function. Keep wireless charging stand away from any liquids or moisture The maximum ambient temperature during use of this product must not exceed 45°C. Do not place device in fire or other excessively hot environments. Only use dry cloth or brush to clean this product. Do not use if visible defects are observed on the wireless charging stand. Warning Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. FCC Statements This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions (1) This device may not cause harmful interference, and (2) This device must accept any interference received including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected Consult the dealer or an experienced radio/TV technician for help This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. November 25, 2019_V1 Place your smartphone or any Qi-enabled device on the center of the charging pad, make sure to cover . . 5W Qi Wireless Charging Pad with Apple Watch Charging Stand . A 12W AC adapter with 5-ft Cable . Additional ring for Apple Watch Charger User Manual What is in the box? Get to know your 5W Qi Wireless Charging Pad with Apple Watch Charging Stand LED status indicator LED Indicator Blue light on for 3 seconds O Blue light on continuously Blue light (flashing) Status Connected to power Stand by for charging Charging device Foreign object detected (Remove it before charging) Begin to charge 12W AC adapterPower outlet on wall LED indicator will be on continuously during charging. 5W Qi Wireless Charging Pad with Apple Watch Charging Stand Model: WIABLK100007907 Need help? We’re here for you every day from 7 a.m. – 9 p.m. CST. Give us a call at 1-888-516-2630 If there is any foreign object detected, LED indicator will be flashing. Remove any foreign object (if any) Example: Magnet or holder *Allow charging any Qi-enabled device and Apple Watch at the same time ** Apple Watch charger is not included We ‘d love to hear from you. Scan with your Walmart app and let us know what you think. Connect 12W AC Adapter with Charging Pad Insert power barrel connector to the connecting port of the charging pad Connect to Power Supply Plug in 12W AC adapter into power outlet for power supply Do not place any credit card on the charging device. 68 11 31 3 57 722 Ring on the charging stand cab be removed and replaced with another ring for dierent size of Apple Watch. Option A Option B Insert USB connector of Apple Watch charger to the built-in USB A port.
ASAP Technology(Jiangxi) Co., Ltd. Date: 2019-12-13 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2APXNLACA125 To whom it may concern: We, the undersigned, hereby authorize SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Shenzhen Branch and Joyce Shi in SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Shenzhen Branch to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with ASAP Technology(Jiangxi) Co., Ltd. This authorization is valid until further written notice from the applicant. Print Name: Xiaolan Deng Title: Manager Signature: On behalf of Company: ASAP Technology(Jiangxi) Co., Ltd. Telephone: +86 796 7118988-38881 E-mail: [email protected]
ASAP Technology(Jiangxi) Co., Ltd. Date: 2019-12-13 To: SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: ASAP Technology(Jiangxi) Co., Ltd. Ji'an Industrial Park Ji'an, Jiangxi 343100 China Regarding: Confidentiality Request regarding application for FCC ID: 2APXNLACA125 LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic Block Diagram Operational Description The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Print Name: Xiaolan Deng Title: Manager Signature: On behalf of Company: ASAP Technology(Jiangxi) Co., Ltd. Telephone: +86 796 7118988-38881 E-mail: [email protected]
ASAP Technology(Jiangxi) Co., Ltd. Cover Letter-Wireless Charger Approval Date: 2019-12-13 Gentlemen: There’s a Wireless Charger that would like to have your authorization as an Inductive wireless power transfer applications approval. The specific product as below, Wireless Charger, with its designed features and specified description, meets special requirements for KDB 680106 D01 section 5.2 requirements. Company: ASAP Technology(Jiangxi) Co., Ltd. Product Name: Wireless Charger Model Number: LACA125, WIABLK100007907 FCC ID: 2APXNLACA125 KDB 680106 D01 Section 5.2 Requirements Product Technical Specification Result a) Power transfer frequency is less that 1 MHz 110.096-148.558kHz Complied b) Output power from each primary coil is less than or equal to 15 watts. 5 watts Max Complied c) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils Complied d) Client device is placed directly in contact with the transmitter. Complied e) Mobile exposure conditions only Complied f) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Please refer to RF exposure report Complied Sincerely, Print Name: Xiaolan Deng Title: Manager Signature: On behalf of Company: ASAP Technology(Jiangxi) Co., Ltd. Telephone: +86 796 7118988-38881 E-mail: [email protected]
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 6 External Photos for SZEM1912021143CR FCC ID: 2APXNLACA125 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 6 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 6
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 4 Internal Photos for SZEM1912021143CR FCC ID: 2APXNLACA125 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 4 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 4 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 4
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202114303 Page: 1 of 9 Keny Xu EMC Laboratory Manager 1 COVER PAGE Human Exposure Report Application No.: SZEM1912021143CR Applicant: ASAP Technology (Jiangxi) Co., Ltd Address of Applicant: Ji'an Industrial Park, Ji'an, Jiangxi 343100 China Manufacturer: ASAP Technology (Jiangxi) Co., Ltd Address of Manufacturer: Ji'an Industrial Park, Ji'an, Jiangxi 343100 China Factory: LUXSHARE-ICT (VIETNAM) LIMITED Address of Factory: E Lot, Quang Chau Industrial zone, Quang Chau Commune, Viet Yen district, Bac Giang Province, Vietnam Equipment Under Test (EUT): EUT Name: Wireless Charger Model No.: LACA125, WIABLK100007907 ♣ ♣ Please refer to section 3.2 of this report which indicates which model was actually tested and which were electrically identical. Trade mark: onn. FCC ID: 2APXNLACA125 Standards: 47 CFR PART 1, Subpart I, Section 1.1310 Date of Receipt: 2019-12-11 Date of Test: 2019-12-12 to 2019-12-20 Date of Issue: 2019-12-24 Test Result : Pass* * In the configuration tested, the EUT complied with the standards specified above SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202114303 Page: 2 of 9 Revision Record Version Chapter Date Modifier Remark 01 2019-12-24 Original Authorized for issue by: Bill Chen /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202114303 Page: 3 of 9 2 Contents 1 COVER PAGE ............................................................................................................................................ 1 2 CONTENTS ................................................................................................................................................ 3 3 GENERAL INFORMATION ........................................................................................................................ 4 3.1 DETAILS OF E.U.T. ................................................................................................................................... 4 3.2 DESCRIPTION OF SUPPORT UNITS ............................................................................................................. 4 3.3 TEST LOCATION ........................................................................................................................................ 5 3.4 TEST FACILITY .......................................................................................................................................... 5 3.5 DEVIATION FROM STANDARDS ................................................................................................................... 5 3.6 ABNORMALITIES FROM STANDARD CONDITIONS.......................................................................................... 5 4 EQUIPMENTS USED DURING TEST ........................................................................................................ 6 5 TEST RESULTS ......................................................................................................................................... 7 5.1 RF EXPOSURE TEST ................................................................................................................................. 7 5.1.1 E.U.T. Operation ............................................................................................................................ 7 6 PHOTOGRAPHS- RF EXPOSURE SETUP ............................................................................................... 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202114303 Page: 4 of 9 3 General Information 3.1 Details of E.U.T. Power Supply: Adapter: Model:LACW011 Input:AC 100-240V ~ 50/60Hz 0.35A Output: DC 5V 2.4A Wireless Charger: Input:DC 5V 2.4A Wireless Charger Output:5W Max USB-A output:DC 5V 1A Cable: DC cable:150cm unshielded Operation frequency: 110.096-148.558kHz Antenna Type: Loop Antenna Modulation Type: Load Modulation Antenna Gain: 0dBi 3.2 Description of Support Units Description Manufacturer Model No. Serial No. SAMSUNG Galaxy S8 SAMSUNG SM-G9500 R28J9140LPB Remark: Model No.: LACA125, WIABLK100007907 Only the model WIABLK100007907 was tested, since the electrical circuit design, layout, components used, internal wiring and functions were identical for all the above models, with only difference on model No. and the appearance. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202114303 Page: 5 of 9 3.3 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab, No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong,China 518057. Tel: +86 755 2601 2053 Fax: +86 755 2671 0594 No tests were sub-contracted. 3.4 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized by ISED as a…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202114302 Page: 1 of 28 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZEM1912021143CR Applicant: ASAP Technology (Jiangxi) Co., Ltd Address of Applicant: Ji'an Industrial Park, Ji'an, Jiangxi 343100 China Manufacturer: ASAP Technology (Jiangxi) Co., Ltd Address of Manufacturer: Ji'an Industrial Park, Ji'an, Jiangxi 343100 China Factory: LUXSHARE-ICT (VIETNAM) LIMITED Address of Factory: E Lot, Quang Chau Industrial zone, Quang Chau Commune, Viet Yen district, Bac Giang Province, Vietnam Equipment Under Test (EUT): EUT Name: Wireless Charger Model No.: LACA125, WIABLK100007907 ♣ ♣ Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. Trade mark: onn. FCC ID: 2APXNLACA125 Standard(s) : 47 CFR Part 15, Subpart C Date of Receipt: 2019-12-11 Date of Test: 2019-12-12 to 2019-12-20 Date of Issue: 2019-12-24 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202114302 Page: 2 of 28 Revision Record Version Chapter Date Modifier Remark 01 2019-12-24 Original Authorized for issue by: Bill Chen /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202114302 Page: 3 of 28 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C N/A 47 CFR Part 15, Subpart C 15.203 Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass 20dB Bandwidth 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.9.2 47 CFR Part 15, Subpart C 15.215 Pass Restricted Bands 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 Pass Radiated Emissions (9kHz-30MHz) 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.4 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Emissions (30MHz-1GHz) 47 CFR Part 15, Subpart C ANSI C63.10 (2013) Section 6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Remark: Model No.: LACA125, WIABLK100007907 Only the model WIABLK100007907 was tested, since the electrical circuit design, layout, components used, internal wiring and functions were identical for all the above models, with only difference on model No. and the appearance. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM191202114302 Page: 4 of 28 3 Contents Page 1 COVER PAGE ..................................................................................................................................... 1 2 TEST SUMMARY ................................................................................................................................. 3 3 CONTENTS ......................................................................................................................................... 4 4 GENERAL INFORMATION .................................................................................................................. 5 4.1 DETAILS OF E.U.T. ......................................................................................................................... 5 4.2 DESCRIPTION OF SUPPORT UNITS .................................................................................................... 5 4.3 MEASUREMENT UNCERTAINTY ......................................................................................................... 5 4.4 TEST LOCATION ............................................................................................................................. 6 4.5 TEST FACILITY ............................................................................................................................... 6 4.6 DEVIATION FROM STANDARDS ......................................................................................................... 6 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................. 6 5 EQUIPMENT LIST ............................................................................................................................... 7 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................10 6.1 ANTENNA REQUIREMENT ................................................................................................................10 6.1.1 Test Requirement: ..................................................................................................................10 7 RADIO SPECTRUM MATTER TEST RESULTS .................................................................................11 7.1 CONDUCTED EMISSIONS AT AC POW ER LINE (150KHZ-30MHZ) ........................................................11 7.1.1 E.U.T. Operation .....................................................................................................................11 7.1.2 Test Setup Diagram ................................................................................................................11 7.1.3 Measurement Procedure and Data .........................................................................................12 7.2 20DB BANDW IDTH .........................................................................................................................15 7.2.1 E.U.T. Operation .....................................................................................................................15 7.2.2 Test Setup Diagram ................................................................................................................15 7.2.3 Measurement Procedure and Data ..........................................…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 3 Setup Photos for SZEM1912021143CR FCC ID: 2APXNLACA125 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 3 1 Photographs 1.1 Conducted Emissions at AC Power Line (150kHz-30MHz) Test Setup SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 3 1.2 Radiated Emissions (9kHz-30MHz) Test Setup 1.3 Radiated Emissions (30MHz-1GHz) Test Setup
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 4 RF Exposure Setup Photos for SZEM1912021143CR FCC ID: 2APXNLACA125 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 4 1 Photographs SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 4 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 4
No.1 Workshop, M-10, Middle Section, · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.110096 MHz - 0.148558 MHz | - |
Wireless Charger Module
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzWireless charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzWireless charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Aircharge Mag
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
10W Qi Wireless Car Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz