WIMU SMART STATION USER MANUAL INTRODUCTION WIMU Smart Station The WIMU Smart Station is an intelligent docking station designed to operate and control several WIMU trackers at the same time. The WIMU SmartStation is able to charge, extract data and modify the configuration of the connected wearable devices. WIMU Smart Station Architecture Characteristics: - Charging Station for WIMU trackers. - Integrated Smart Screen. - Capacity: up to 28 devices. Connectivity - Ethernet: Gigabit Ethernet (Max 300 Mb/s) - 3 x USB: USB 2.0 ports - Bluetooth - Frequency Range: 2402-2480 [MHz] - Maximum Tx Power: 11.6dBm - WiFi - IEEE 802.11 b/g/n/ac (Max 433.3 Mb/s) - Frequency Range: 2400 - 2483.5 [MHz] - Maximum Tx Power: 14.7dBm Dimensions: - Width: 430 mm, High: 155 mm, 375 mm. - Weight: 6, 5 Kg. GETTING STARTED GUIDE Introduction The screen is split in two sections, the connections panel and the operations panel. In the upper side of the screen, the connections panel provides a real-time representation of the Smart Station connected devices. Each slot provides basic information for each connected WIMU, such as its identifier, battery level or the use of the device memory. In the lower side of the screen, the operations panel allows you to execute a set of actions over the selected WIMU/WIMUs, whose selection can be toggled by touching the desired slot in the connections panel. Also, two buttons are provided to facilitate selecting or deselecting all connected devices (“Select All” and “Deselect All”). All WIMUs are selected by default. When you press for a few seconds any of the connected WIMUs in the connections panel, a new configuration window appears. In it you can visualize and edit WIMU tracker key parameters as the player name and number of the device, WIMU ID and the ID of the Heart Rate band associated with that specific WIMU (editing this information will imply a device reboot) and its frequency number necessary for linking the device to the SVIVO software. In addition, information on the sampling frequency and the data collection profile appears. Actions The main actions list is detailed below: 1. Shutdown Allows to shutdown or reboot the selected WIMU/WIMUs. 2. PC Mode When the Smart Station is connected to a PC using the provided USB cable, the PC mode option enables a direct connection between the WIMUs and the PC. This option shall be used to download the data from the WIMUs to the PC. Note that while this option is enabled, no other action can be performed with the Smart Station. 3. Start Log The selected WIMU/WIMUs will start recording data. 4. Stop Log Disables the data recording of all the WIMU that are currently logging. Note that all the affected WIMU will be rebooted in order to ensure the data integrity. 5. Copy All and Copy Last Create a copy of all stored data or the last session of the selected WIMU/WIMUs. This option is only available when the Smart Station detects an external mass storage device in one of its USB slots. This option is used to download the trackers data into a portable USB memory device. Do not disconnect the device until the operation is complete. 6. Set All Profile Changes the profile of the selected WIMU/WIMUs. This operation requires a reboot of the affected WIMU/WIMUs once the modification is applied. Currently, the available profiles are GPS, UWB, GPS/UWB and None. - UWB: Only UWB is enabled (indoor) - GPS: Only GPS is enabled. - GPS/UWB: Both GPS and UWB are enabled. - None: Both GPS and UWB are disabled. 7. Set All Autolog Configure the selected WIMU/WIMUs so that the device will start recording data automatically as soon as it detects the location signal of the profile in which the device is configured, either GPS, UWB or UWB/GPS. 8. Set All Freq Changes the sampling rate of the selected WIMU or WIMUs. This operation requires a reboot of the affected WIMU/WIMUs. The available sampling rates are 10, 100, 500 and 1000 Hertzs. 100 Hz is selected by default. TECHNICAL SPECIFICATIONS (WIMU SMART STATION) ELECTRICAL SPECIFICATIONS INPUT OUTPUT VOLTS 100-240 V AC 5 V DC AMPERES 2.5 A 40 A FREQUENCY 50/60 Hz 50 /60 Hz MAINTENANCE Maintenance Warning ● Use the WIMU Smart Station only as directed in this user manual. ● Do not disassemble the device. ● Protect the device from possible damage. Do not drop or expose to excessive heat or excessive sun exposure. ● Store the device in a clean and dry place, at room temperature. ● Avoid scratching the device. ● Do not expose the device to water or other liquids or humidity. Cleaning ● Clean the device with a dry cloth. ● Do not use gasoline, solvents, acetone, alcohol, repellents, paints or any other chemical products on the device. IMPORTANT SAFETY INFORMATION WARNING: Failure to follow these safety instructions could result in fire, electric shock, or other injuries, or damage to your WIMU Smart Station or other property. Real all safety information below before using your WIMU Smart Station. ● Handle the WIMU Smart Station device with care. The WIMU Smart Station and its electrical components can be damaged, have impaired functionality, or cause injury if the WIMU Smart Station is dropped, punctured, crushed, disassembled, or exposed to excessive heat or to humidity or liquids. Don’t use a damaged WIMU Smart Station. Refer all servicing to the manufacturer. ● Clean this device only with a dry cloth. ● Only use attachments/accessories specified by the manufacturer with this device. ● Connect this device to a power source only with the included power cord. Other power cords might not meet applicable regulations and safety standards. ● Don’t expose this device to rain, liquids, or moisture. ● Don’t use this device near water or in wet conditions. ● Don’t use this device near any heat sources such as radiators, heat registers, stoves, or other devices that produce heat or near fire. ● Don’t make unauthorized alterations to this device. ● Don’t use this device with a damaged power cord or plug. REGULATORY NOTICES Pr…
Text truncated - open the document above for the full version.
C5266091_X24_Ed.1 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: REALTRACK SYSTEMS SLU Grantee code: 2AQOV FCC ID: 2AQOV-WS200 Contact Name: ISABEL PEREZ SEGURA Address: CALLE GUINEA, 2 04009 ALMERIA SPAIN Telephone No: +34 950 265960 +34 950 272379 Fax No: Email: [email protected] i. REALTRACK SYSTEMS SLU (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. REALTRACK SYSTEMS SLU (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. Date: 2023/06/22 Applicant’s Name: ISABEL PEREZ SEGURA, REALTRACK SYSTEMS SLU Title: WEARABLES MARKET DIRECTOR Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist
C5266091_X8_Ed.1 1/1 Letter of Authorization Company: REALTRACK SYSTEMS SLU Address: CALLE GUINEA, 2 04009 ALMERIA SPAIN Product Name: SmartStation Model Number: WS200 FCC Identifier: 2AQOV-WS200 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: ISABEL PEREZ SEGURA Date: Title: WEARABLES MARKET DIRECTOR Signature of applicant:
C566091_X23_Ed2 1/1 TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Applicant: Company name: REALTRACK SYSTEMS SLU Product Description: Embedded system wearable device for sport analytics. Grantee code: 2AQOV FCC ID: 2AQOV-WS200 Contact Name: ISABEL PEREZ SEGURA Address: CALLE GUINEA, 2 04009 ALMERIA SPAIN Telephone No: +34 950 265969, +34 950 272379 Email: [email protected] The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 2023/06/22 Applicant’s Name: ISABEL PEREZ SEGURA Title: WEARABLES MARKET DIRECTOR Signature Signature US Agent for Service of Process: Company Name: QPS America, Inc. FRN: 0033412354 Contact Name: John Gulino Address: 5005 Rockside Road, Suite 600, Independence, Ohio 44131-6827 Telephone: 216-377-3191 Email: [email protected] This letter is to confirm that the US Agent for Service of Process accepts responsibility to act as a local representative on behalf ofREALTRACK SYSTEMS SLU. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. US Agent’s Name: John Gulino Title: President US Agent for Service of Process LETTER OF ATTESTATION
EXTERNAL PICTURES
Page 1 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC SDoC TEST REPORT REALTRACK SYSTEMS SL SMART STATION EVO Test Model: WS200 Prepared for : REALTRACK SYSTEMS SL Address : Calle Guinea, 2; Almería, 04009 Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : May 06, 2023 Number of tested samples : 2 Serial number : Prototype Date of Test : May 06, 2023 ~ June 28, 2023 Date of Report : July 27, 2023 Page 2 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC SDoC TEST REPORT FCC 47 CFR Part 15 Subpart B, Class A(SDoC), ANSI C63.4 -2014 Report Reference No. ......... : LCSA050523114E001 Date Of Issue .......................... : July 27, 2023 Testing Laboratory Name .... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .................................. : Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Testing Location/ Procedure ... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name.................. : REALTRACK SYSTEMS SL Address .................................. : Calle Guinea, 2; Almería, 04009 Test Specification Standard ................................. : FCC 47 CFR Part 15 Subpart B, Class A(SDoC), ANSI C63.4 -2014 Test Report Form No. ............. : LCSEMC-1.0 TRF Originator ........................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ............................. : Dated 2011-03 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. is acknowledged as copyright owner and source of the material. SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .......... : SMART STATION EVO Trade Mark ............................. : SmartStation WS200 Test Model ............................ : WS200 Ratings ................................... : Input: AC 100-240 V Output:DC 5V Result ................................... : Positive Compiled by: Supervised by: Approved by: Jack Liu/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC SDOC-- TEST REPORT Test Result according to the standards on page 6: Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA050523114E001 July 27, 2023 Date of issue Test Model ........................ : WS200 EUT.................................... : SMART STATION EVO Applicant........................... : REALTRACK SYSTEMS SL Address.............................. : Calle Guinea, 2; Almería, 04009 Telephone.......................... : / Fax..................................... : / Manufacturer..................... : REALTRACK SYSTEMS SL Address.............................. : Calle Guinea, 2; Almería, 04009 Telephone.......................... : / Fax..................................... : / Factory.............................. : REALTRACK SYSTEMS SL Address.............................. : Calle Guinea, 2; Almería, 04009 Telephone.......................... : / Fax..................................... : / Page 4 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 June 28, 2023 Initial Issue --- 001 July 27, 2023 Added Radiated disturbance test --- Page 5 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABLE OF CONTENTS Test Report Description Page 1. SUMMARY OF STANDARDS AND RESULTS .............................................................................. 6 1.1. Description of Standards and Results ................................................................................................ 6 2. GENERAL INFORMATION …
Text truncated - open the document above for the full version.
Page 36 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 27 Fig. 28 Page 37 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 29 Fig. 30 Page 38 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 31 Fig. 32 Page 39 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 33 Fig. 34 Page 40 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 35 Fig. 36 Page 41 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 37 Fig. 38 Page 42 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 39 Fig. 40 Page 43 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 41 Fig. 42 Page 44 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 43 Fig. 44 Page 45 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 45 Fig. 46 Page 46 of 46 Report No.: LCSA050523114E001 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -----------------THE END OF TEST REPORT-----------------
Calle Guinea 2 · Almeria · Spain
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

Embedded system wearable device for sport analytics
Equipment Class
DTS - Digital Transmission System
WIMU PRO
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter