UV sterilizer box Instruction No. Product Model Input Outp ut battery Wireless charging Outer Sizes(mm) Inner size: (mm) Weight(g) PS-426 USB-C PD 18W 5V 2.4A 5200m Ah 10W L225*W120*H34mm L170*W90*H22mm 405g Description: UVC sterilizer box with wireless charging 10W+Power bank. Model: PS-426 1.Wireless indication LED light: 1.1: Press and hold the button for 2S to start wireless charging, Green LED flashing 3times to enter into standby mode, then LED off. 1.2: Working status: Green LED solid on. 1.3: FOD: Red LED flash. 1.4: Over temperature: Red LED flash. 1.5: Press and hold the button for 2S to shut off. 2.UV disinfection LED light: 2.1: Quick click the button once to turn on the white LED and start disinfecting for 5 minutes. 2.2: Disinfecting time last for 5minutes, count-down 30S disinfection to stop. 3.Battery indication LED light: 3.1: Working status: The blue LED flash when charging and the blue LED solid on when fully charged. LED solid on from battery indication 1 to battery indication 3 in turn. 3.2: Discharging: LED turns off from indicator 3 to indicator 1 in turn. 4.Feature: 4.1: Kill escherichia coli, candida albicans, golden aureus and other bacterias effect up to 99%. 4.2: Extra USB-A port support charging for both Android and iOS Smart phones. 4.3: UV sterilizing box for Cellphones, Watches, Jewelry, Airpods, Glasses, Masks,etc. 4.4: USB-C input can allow wireless charging, USB-A Charging and UV box running simultaneously, total output max 18W. 4.5: Certificates: CE, RoHS, FCC. FCC Caution This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. *RF warning for Mobile device: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
C5266091_X8_Ed.1 1/1 LetterofAuthorization PowerSystemElectronicTechnologyCo.,Ltd. Company:PowerSystemElectronicTechnologyCo.,Ltd. Address:No.1ShangbianRoad,PuxinIndustrialDistrict,ShipaiTown, DongguanCity,Guangdong,China ProductName:Multi-FunctionPortableUVLightSterilizer ModelNumber:PS-426 FCCIdentifier:2AQTM-STERILIZERBOX WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:ShirleyLamDate:2020-07-21 Title:Merchandiser Signatureofapplicant:
C5266091_X10_Ed.2 1/1 PowerSystemElectronicTechnologyCo.,Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2020-07-21 Subject: Request for Confidentiality FCC ID: 2AQTM-STERILIZERBOX To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/LocationNoNo Attestation StatementNoNo External PhotosNo ☐ Block Diagram ☒☐ Schematics ☒☐ Test ReportNoNo Test Setup PhotosNo ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ Parts List / Tune Up ☐ RF Exposure InfoNoNo Operational Description ☒☐ Cover Letter(s)NoNo SDR Software / Security InfoNo NOTE 1: Long-Term Confidentiality may be permitted under special conditions (SeeII. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. ☐ NOTE 1 ☐ ☐ C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name:ShirleyLam Title:Merchandiser
FCC ID: 2AQTM-STERILIZERBOX
V01 2020.07.15 利伟聪 技术要求: 1. 移印颜色877C; 2. 钢板尺寸为L100*W70*H10mm; 3. 移印要清晰,不可有掉字,毛边等不良; 4. 需用烤箱烤30min; 5. 酒精测试:用浓度为95%的酒精,500克力来回擦拭30次,没有褪色; 6. 粘贴测试:用600 3M胶平整贴于产品移印位置,与产品成45度角方向撕扯3M胶,不能有掉油现象; 7. 耐磨测试:用橡皮擦来回磨擦产品移印200次,不能掉油 8. 公差值为±0.5mm 丝印 PS021-050B/W YY0P00000609 YY0P00000606 Model No.: PS-426USB-C Input/Output: PD 18W(5V 3A, 9V 2A, 12V 1.5A)USB-A Output: QC 3.0(5V 3A, 9V 2A, 12V 1.5A)Wireless: 5W/7.5W/10WTotal Output: 18W MaxCapacity: 5200 mAhWave length: 254nmUV Power: 2W FCC ID: 2AQTM-STERILIZERBOX This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 340 mm 240 mm 26 mm 26 mm 68 mm 52 mm
FCC ID: 2AQTM-STERILIZERBOX Antenna
ReportNo.:PTC20062402901E-FC02 Page 1 of 11 FCCTESTREPORT FCCID:2AQTM-STERILIZERBOX Product:Multi-FunctionPortableUVLightSterilizer ModelName:PS-426 Brand:PowerSystem ReportNo.:PTC20062402901E-FC02 Preparedfor PowerSystemElectronicTechnologyCo.,Ltd. No.1ShangbianRoad,PuxinIndustrialDistrict,ShipaiTown,DongguanCity,Guangdong,China Preparedby PreciseTesting&CertificationCo.,Ltd. Building1,No.6,TongxinRoad,DongchengStreet,Dongguan,Guangdong,China ReportNo.:PTC20062402901E-FC02 Page 2 of 11 TESTRESULTCERTIFICATION Applicant’sname: PowerSystemElectronicTechnologyCo.,Ltd. Address: No.1ShangbianRoad,PuxinIndustrialDistrict,ShipaiTown,Dongguan City,Guangdong,China Manufacture'sname: PowerSystemElectronicTechnologyCo.,Ltd. Address: No.1ShangbianRoad,PuxinIndustrialDistrict,ShipaiTown,Dongguan City,Guangdong,China Productname:Multi-FunctionPortableUVLightSterilizer Modelname:PS-426 TestprocedureKDB680106D01RFExposureWirelessChargingAppsv03 TestDate:Jun30,2020toJul20,2020 DateofIssue:Jul20,2020 TestResult:Pass ThisdevicedescribedabovehasbeentestedbyPTC,andthetestresultsshowthatthe equipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlyto thetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofPTC,thisdocument maybealteredorrevisedbyPTC,personalonly,andshallbenotedintherevisionofthedocument. TestEngineer: LeoYang/Engineer TechnicalManager: ChrisDu/Manager ReportNo.:PTC20062402901E-FC02 Page 3 of 11 Contents Page 2TESTSUMMARY................................................................................................................................................4 2.1TESTEQUIPMENTLIST..............................................................................................................................4 3GENERALINFORMATION...............................................................................................................................5 3.1GENERALDESCRIPTIONOFE.U.T..........................................................................................................5 4RFEXPOSURE...................................................................................................................................................6 4.1REQUIREMENTS........................................................................................................................................6 4.2TESTSETUP..............................................................................................................................................7 4.3TESTPROCEDURE....................................................................................................................................8 4.4TESTRESULT............................................................................................................................................8 APPENDIXI--TESTSETUPPHOTOGRAPH...............................................................................................11 ReportNo.:PTC20062402901E-FC02 Page 4 of 11 2TestSummary TestItemsTestRequirementResult MaximumPermissibleExposure (ExposureofHumanstoRFFields) 1.1307(b)(1)PASS Remark: N/A:NotApplicable 2.1TestEquipmentList ItemEquipmentManufacturerModelNo.SerialNo.LastCal. Cal. Interval 1 Magneticfield meter NARDAELT-400423623 Aug.21,2020 1Year 2E-FieldProbeNardaEF0391Q15221 Aug.21,2020 3Year 3H-FieldProbeNardaHF3061Q15835 Aug.21,2020 3Year ReportNo.:PTC20062402901E-FC02 Page 5 of 11 3GeneralInformation 3.1GeneralDescriptionofE.U.T. ProductName : Multi-FunctionPortableUVLightSterilizer ModelName : PS-426 OperationFrequency : 110.1-205KHz TypeofModulation : ASK Antennainstallation : InductiveloopcoilAntenna AntennaGain : 0dBi Powersupply : Input:100-240V~50/60Hz,0.8A Output:DC5V,3A/DC9V,2.66A/DC12V,2A HardwareVersion : N/A SoftwareVersion : N/A ReportNo.:PTC20062402901E-FC02 Page 6 of 11 4RFExposure TestRequirement :FCCPart1.1307(b)(1) EvaluationMethod :FCCPart2.1091 4.1Requirements Accordingtotheitem5.b)ofKDB680106D01v03: Inductivewirelesspowertransferapplicationsthatmeetallofthefollowingrequirementsare excludedfromsubmittinganRFexposureevaluation. 1)Powertransferfrequencyislessthat1MHz 2)Outputpowerfromeachprimarycoilislessthanorequalto15watts. 3)Thetransfersystemincludesonlysingleprimaryandsecondarycoils.Thisincludescharging systemsthatmayhavemultipleprimarycoilsandclientsthatareabletodetectandallow couplingonlybetweenindividualpairsofcoils 4)Clientdeviceisinsertedinorplaceddirectlyincontactwiththetransmitter 5)Mobileexposureconditionsonly(portableexposureconditionsarenotcoveredbythis exclusion) 6)TheaggregateH-fieldstrengthsat15cmsurroundingthedeviceand20cmabovethetop surfacefromallsimultaneoustransmittingcoilsaredemonstratedtobelessthan50%oftheMPE limit. LimitsForMaximumPermissibleExposure(MPE) ReportNo.:PTC20062402901E-FC02 Page 7 of 11 4.2TestSetup 20cm 15cm ReportNo.:PTC20062402901E-FC02 Page 8 of 11 Note:Measurementsshouldbemadeat15cmsurroundingtheEUTand20cmabovethe topsurfaceoftheEUT. 4.3TestProcedure 1)TheRFexposuretestwasperformedinanechoicchamber. 2)Themeasurementprobewasplacedatrequiredtestdistancewhichisbetweentheedgeofthe chargerandthegeometriccenterofprobe. 3)Thehighestemissionlevelwasrecordedandcomparedwithlimitassoonasmeasurementof eachpoints (A,B,C,D,E)werecompleted.(Aistheright,Bistheback,Cistheleft,Disthefront,andEis thetop.) 4)TheEUTwasmeasuredaccordingtothedictatesofKDB680106D01v03. Remark; TheEUT’stestpositionA,B,C,DandEisvalidfortheEandHfieldmeasurements. 4.4TestResult EquipmentApprovalConsiderationsitem5.bofKDB680106D01v03. 1)Powertransferfrequencyislessthat1MHz -Thedeviceoperateinthefrequencyrange110.1~205KHz 2)Outputpowerfromeachprimarycoilislessthan15watts -Themaximumoutputpoweroftheprimarycoilis10W. 3)Thetransfersystemincludesonlysingleprimaryandsecondarycoils.Thisincludescharging systemsthatmayhavemultipleprimarycoilsandclientsthatareabletodetectandallow couplingonlybetweenindividualpairsofcoils -Thetransfersystemincludingachargingsyste…
Text truncated - open the document above for the full version.
Page1of29 FCCTESTREPORT FCCID:2AQTM-STERILIZERBOX Product:Multi-FunctionPortableUVLightSterilizer ModelName:PS-426 Brand:PowerSystem ReportNo.:PTC20062402901E-FC01 Preparedfor PowerSystemElectronicTechnologyCo.,Ltd. No.1ShangbianRoad,PuxinIndustrialDistrict,ShipaiTown,DongguanCity,Guangdong,China Preparedby PreciseTesting&CertificationCo.,Ltd. Building1,No.6,TongxinRoad,DongchengStreet,Dongguan,Guangdong,China ReportNo.:PTC20062402901E-FC01 Page2of29 1TESTRESULTCERTIFICATION Applicant’sname: PowerSystemElectronicTechnologyCo.,Ltd. Address: No.1ShangbianRoad,PuxinIndustrialDistrict,ShipaiTown,DongguanCity, Guangdong,China Manufacture'sname: PowerSystemElectronicTechnologyCo.,Ltd. Address: No.1ShangbianRoad,PuxinIndustrialDistrict,ShipaiTown,DongguanCity, Guangdong,China Productname:Multi-FunctionPortableUVLightSterilizer Modelname:PS-426 Standards:FCCPart15SubpartC Testprocedure:ANSIC63.10:2013 TestDate:Jun30,2020toJul20,2020 DateofIssue:Jul20,2020 TestResult:Pass ThisdevicedescribedabovehasbeentestedbyPTC,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofPTC,thisdocumentmaybe alteredorrevisedbyPTC,personalonly,andshallbenotedintherevisionofthedocument. TestEngineer: LeoYang/Engineer TechnicalManager: ChrisDu/Manager ReportNo.:PTC20062402901E-FC01 Page3of29 Contents Page 1TESTRESULTCERTIFICATION................................................................................................................................2 2TESTSUMMARY...........................................................................................................................................................4 3GENERALINFORMATION..........................................................................................................................................5 3.1GENERALDESCRIPTIONOFE.U.T.....................................................................................................................5 3.2DESCRIPTIONOFTESTMODES...........................................................................................................................6 3.3TESTSITE.............................................................................................................................................................7 4EQUIPMENTDURINGTEST.......................................................................................................................................8 4.1EQUIPMENTSLIST................................................................................................................................................8 4.2MEASUREMENTUNCERTAINTY............................................................................................................................9 5TESTSTANDARDANDLIMIT.................................................................................................................................10 5.1TESTSETUP......................................................................................................................................................10 5.2TESTPROCEDURE.............................................................................................................................................10 5.3.TESTDATA........................................................................................................................................................11 6RADIATIONSPURIOUSEMISSIONANDBANDEDGE....................................................................................13 6.1TESTSTANDARDANDLIMIT..............................................................................................................................13 6.2TESTSETUP......................................................................................................................................................14 6.3TESTPROCEDURE.............................................................................................................................................15 6.4TESTDATA........................................................................................................................................................15 7ANTENNAREQUIREMENT......................................................................................................................................19 7.1TESTSTANDARDANDREQUIREMENT..............................................................................................................19 7.2ANTENNACONNECTEDCONSTRUCTION..........................................................................................................19 APPENDIXI--TESTSETUPPHOTOGRAPH..........................................................................................................20 APPENDIXII--EXTERNALPHOTOGRAPH............................................................................................................22 ReportNo.:PTC20062402901E-FC01 Page4of29 2TestSummary StandardSectionTestItemResult FCCPart15,Paragraph15.207ConductedEmissionTest PASS FCCPart15,Paragraph 15.209(a)(f) SpuriousEmission PASS Part15.203AntennaRequirementPASS ReportNo.:PTC20062402901E-FC01 Page5of29 3GeneralInformation 3.1GeneralDescriptionofE.U.T. ProductName : Multi-FunctionPortableUVLightSterilizer ModelName : PS-426 OperationFrequency : 110.1-205KHz TypeofModulation :ASK Antennainstallation : InductiveloopcoilAntenna AntennaGain : 0dBi Powersupply : Input:100-240V~50/60Hz,0.8A Output:DC5V,3A/DC9V,2.66A/DC12V,2A HardwareVersion : N/A SoftwareVersion : N/A ReportNo.:PTC20062402901E-FC01 Page6of29 3.2DescriptionofTestModes ToinvestigatethemaximumEMIemissioncharacteristicsgeneratesfromEUT,thetestsystem waspre-scanningtestedbaseontheconsiderationoffollowingEUToperationmodeortest configurationmodewhichpossiblehaveeffectonEMIemissionlevel.EachoftheseEUT operationmode(s)ortestconfigurationmode(s)mentionedabovewas…
Text truncated - open the document above for the full version.
Conducted Emissions Radiated Spurious Emissions From 30MHz-1000MHz FCC ID: 2AQTM-STERILIZERBOX
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1101 MHz - 0.205 MHz | - |

BASECAMP 4
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
3 in 1 Magnetic Wireless Charger & Portable Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz