FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. NIE-TECH CO., LTD/
  3. 2AQURMP22RTX90

2AQURMP22RTX90RF remote

NIE-TECH CO., LTD
RF remote - FCC ID 2AQURMP22RTX90 - NIE-TECH CO., LTD
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jul 10, 2022
Application Purpose
Original Equipment
Date of Application
Jul 10, 2022
Equipment Note
RF remote
Frequency Range
433.92000000 - 433.92000000
Company
NIE-TECH CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

โ†—

Cover Letter(s)

โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

Test Report

โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

RemoteControlManual ModelNo.:MP22R-TX90 Howitworks: 1.PressandholdtheON/OFFbuttononthe receiveroutletfor3secondsandtheLEDindicatorwill startflashingslowly. 2.ReleasetheON/OFFbuttononthereceiver andpressONorOFFbuttononthetransmitter topairthetransmittertothereceiver. FCCCaution. Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)Thisdevicemaynotcauseharmful interference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation. AnyChangesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser'sauthoritytooperatethe equipment. Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttopart15oftheFCCRules.These limitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgeneratesusesandcan radiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradio communications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmful interferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrect theinterferencebyoneormoreofthefollowingmeasures: -Reorientorrelocatethereceivingantenna. -Increasetheseparationbetweentheequipmentandreceiver. -Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected. -Consultthedealeroranexperiencedradio/TVtechnicianforhelp. *RFwarningforPortabledevice: ThedevicehasbeenevaluatedtomeetgeneralRFexposurerequirement.Thedevicecanbeusedinportableexposureconditionwithoutrestriction.

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letterof Authorization NIE-TECH Co., Ltd Company: NIE-TECH Co., Ltd Address: Jinlian commercial center 9001, Jinxiu road No.273, Changan Town,Dongguan City, GuangDong Prov., CHINA Product Name: RF remote Model Number: MP22R-TX90 FCC ID: 2AQURMP22RTX90 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name:JianghaiNieDate: 2022-07-04 Title:Manager Signatureof applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 NIE-TECHCo.,Ltd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2022-07-04 Subject:RequestforConfidentiality FCCID:2AQURMP22RTX90 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo โ˜ BlockDiagram โ˜’โ˜ Schematics โ˜’โ˜ TestReportNoNo TestSetupPhotosNo โ˜ Userโ€™sManual โ˜ NOTE 1 โ˜ InternalPhotos โ˜ NOTE 1 โ˜ PartsList/TuneUp โ˜โ˜ RFExposureInfoNoNo OperationalDescription โ˜’โ˜ CoverLetter(s)NoNo SDRSoftware/SecurityInfo โ˜ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodofdaysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, C5266091_X10_Ed.2 1/1 Signature: Name:JianghaiNie Title:Manager

Internal Photos

ANT

Test Report

ReportNo.:PTC22041806801E-FC01 Page 1 of 28 FCCTESTREPORT FCCID:2AQURMP22RTX90 Product:RFremote ModelName: MP22R-TX90 Brand: Ministon ReportNo.:PTC22041806801E-FC01 Preparedfor NIE-TECHCo.,Ltd Jinliancommercialcenter9001,JinxiuroadNo.2,ChanganTown,DongguanCity,GuangDongProv., CHINA Preparedby PreciseTesting&Certification(Guangdong)Co.,Ltd. Building1,No.6,TongxinRoad,DongchengStreet,Dongguan,Guangdong,China ReportNo.:PTC22041806801E-FC01 Page 2 of 28 TESTRESULTCERTIFICATION Applicantโ€™sname:NIE-TECHCo.,Ltd Address: Jinliancommercialcenter9001,JinxiuroadNo.2,Changan Town,DongguanCity,GuangDongProv.,CHINA Manufacture'sname:NIE-TECHCo.,Ltd Address:Jinliancommercialcenter9001,JinxiuroadNo.2,Changan Town,DongguanCity,GuangDongProv.,CHINA Product:RFremote Model:MP22R-TX90 Standards :FCCCFR47Part15Section15.231 Testprocedure :ANSIC63.10:2013 TestDate: May.31,2022toJul.08,2022 DateofIssue: Jul.08,2022 TestResult :Pass ThisdevicedescribedabovehasbeentestedbyPTC,andthetestresultsshowthatthe equipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditisapplicable onlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofPTC,this documentmaybealteredorrevisedbyPTC,personalonly,andshallbenotedintherevision ofthedocument. TestingEngineer: SimonPu/Engineer TechnicalManager: RonnieLiu/Manager ReportNo.:PTC22041806801E-FC01 Page 3 of 28 Contents Page 2TESTSUMMARY.........................................................................................................................................4 3GENERALINFORMATION........................................................................................................................5 3.1GENERALDESCRIPTIONOFE.U.T.....................................................................................................5 3.2TESTMODE.........................................................................................................................................5 3.3TESTSITE............................................................................................................................................5 4EQUIPMENTDURINGTEST.....................................................................................................................6 4.1EQUIPMENTSLIST...............................................................................................................................6 4.2MEASUREMENTUNCERTAINTY...........................................................................................................6 5CONDUCTEDEMISSION..........................................................................................................................7 5.1E.U.T.OPERATION.............................................................................................................................7 5.2EUTSETUP.........................................................................................................................................7 5.3TESTSET-UP(BLOCKDIAGRAMOFCONFIGURATION)...................................................................8 5.4MEASUREMENTPROCEDURE..............................................................................................................8 5.5CONDUCTEDEMISSIONLIMIT.............................................................................................................8 5.6MEASUREMENTDESCRIPTION............................................................................................................8 5.7CONDUCTEDEMISSIONTESTRESULT...............................................................................................8 6PERIODICOPERATION............................................................................................................................9 7RADIATEDSPURIOUSEMISSIONS.....................................................................................................13 7.1EUTOPERATION...............................................................................................................................13 7.2TESTSETUP......................................................................................................................................15 7.3SPECTRUMANALYZERSETUP..........................................................................................................16 7.4TESTPROCEDURE............................................................................................................................17 7.5SUMMARYOFTESTRESULTS...........................................................................................................18 820DBBANDWIDTHMEASUREMENT..................................................................................................21 8.1TESTPROCEDURE............................................................................................................................21 8.2TESTRESULT....................................................................................................................................21 9ANTENNAREQUIREMENT....................................................................................................................22 10TESTSETUP..............................................................................................................................................23 11EUTPHOTOS.............................................................................................................................................24 ReportNo.:PTC22041806801E-FC01 Page 4 of 28 2TestSummary TestItemsTestRequirementResult ConductedEmissions15.207N/A RadiatedEmission 15.231(a) 15.209 15.205(a) PASS PeriodicOperation 15.35(c) 15.231(a) PASS OutsideofBandEmission 15.231(a) 15.205 15.209 PASS 20dBBandwidth 15:215(c) PASS AntennaRequirement15.203PASS Remark: N/A:NotApplicable ReportNo.:PTC22041806801E-FC01 Page 5 of 28 3GeneralInformation 3.1GeneralDescriptionofE.U.T. ProductName : RFremote ModelName : MP22R-TX90 OperationFrequency: : 433.92MHz Anโ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

RadiatedEmissions From30MHz-1000MHz TestfrequencyfromAbove1GHz

Contact Information

Applicant

Jianghai Nie(Manager)
[email protected]13751285558Fax: 86 (769) 82286661

Technical Contact

NIE-TECH CO., LTDJianghai Nie
[email protected]13751285558

Dongguan ยท China

Test Firm

Precise Testing & Certification Co., LTD.Chris Du
[email protected]+86-769-38808222

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from NIE-TECH CO., LTD

2 Button Remote ON/ON - FCC ID 2AQUR-RF922 - NIE-TECH CO., LTD
2AQUR-RF922

2 Button Remote ON/ON

Jun 10, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
ON/OFF SWITCH 800 - FCC ID 2AQUR-ZW305Z - NIE-TECH CO., LTD
2AQUR-ZW305Z

ON/OFF SWITCH 800

Mar 03, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wi-Fi Countdown Timer Switch - FCC ID 2AQURNHT06W - NIE-TECH CO., LTD
2AQURNHT06W

Wi-Fi Countdown Timer Switch

Jun 26, 2024

Equipment Class

DTS - Digital Transmission System
Wi-Fi Countdown Timer Switch - FCC ID 2AQURNHTO6W - NIE-TECH CO., LTD
2AQURNHTO6W

Wi-Fi Countdown Timer Switch

Jun 26, 2024

Equipment Class

DTS - Digital Transmission System
Z-Wave Mini Smart Plug (800S) - FCC ID 2AQURZW37MU - NIE-TECH CO., LTD
2AQURZW37MU

Z-Wave Mini Smart Plug (800S)

Mar 08, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter