FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. NIE-TECH CO., LTD/
  3. 2AQURRF924

2AQURRF924RF remote

NIE-TECH CO., LTD
RF remote - FCC ID 2AQURRF924 - NIE-TECH CO., LTD
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Dec 14, 2022
Application Purpose
Original Equipment
Date of Application
Dec 14, 2022
Equipment Note
RF remote
Frequency Range
433.92000000 - 433.92000000
Company
NIE-TECH CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

SIZE: 180 x 120 mm 90 x 57 mm This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, undesired operation. changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. (2) This device must accept any interference received, including interference that may cause FCC warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interfer- ence to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following meas- ures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. NOTE: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environ- ment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with minimum distance 20cm between the radiator& your body. If you are unsure or uncomfortable about performing this installation consult a qualified electrician. FCC Radiation Exposure Statement: Risk of Fire / Risk of Electrical Shock / Risk of Burns Please DO NOT use this plug to control Medical or Life Support equipment. This device should never be used to control the On/Off status of Medical and/or Life Support equipment. OTHER WARNINGS MEDICAL EQUIPMENT IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. Read and follow all instructions that are on the product or provided with the product. 3. do not use an extension cord. 4. Reference the National Electrical Code, NFPA 70, specifically for the installation of wiring 5. Installation work and electrical wiring must be done by qualified person(s) in accordance 6. do not install or use within 10 feet of a pool 7. do not use in a bathroom 8. WARNING: 9. WARNING: 10.WARNING: SAVE THESE INSTRUCTIONS – This manual contains important safety and operating instructions. Risk of Electric Shock. Mount the unit at a height greater than 1 foot from the ground surface Risk of Electric fire. install only to a receptacle protected by 20A branch circuit over current protection. Risk of Electric Shock. When used outdoors, install only to a covered Class A GFCI protected receptacle that is weatherproof with the power unit connected to the receptacle. If one is not provided, contact a qualified electrician for proper installation. Ensure that the power unit andcord do not interfere with completely closing the receptacle cover. andclearances from power and lighting conductors. with allapplicable codes and standards, including fire-rated construction. This device is intended for installation in accordance with the National Electric Code and local regulations in the United States, or the Canadian Electrical Code and local regulations in Canada. CAUTION - PLEASE READ! 1. Follow the instructions for your Z-Wave certified controller to add device from the Z-Wave network. network. mes, LED is flashing in purple during exclusion and the LED stays on green for 2 seconds after e- xclusion successfully. LED will stay red for 2 seconds after exclusion failed. hen device goes back to sleep mode. is flashing in blue during inclusion and LED stays on green for 2 seconds after inclusion successf- 1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave Press the THIRD BUTTON 5 times quickly, LED will stay solid on blue when awake and will turn off w- Manual: Reset: Press the FOUR BUTTON 5x, then press it 5x again when the red light is flashing. 2. Once the controller is preparing to remove your device, press the SECOND BUTTON (ONLY) 5 ti- 2. Once the controller is preparing to add your device, press the FIRST BUTTON(ONLY) 5 times, LED ully. If LED flashing purple for 3 seconds, please reset the device. LED will stay on red for 2 secon- ds after inclusion failed. Battery position Open and access the battery Inclusion/Exclusion Function To add the device To remove the device Wake up the Device Factory reset Remote Control Switch Model – RF924-TX Battery: CR2032*2 Frequency: 433.92MHz Temperature Range: 32°F~104°F Indoor use in dry location Specifications: 2. Do not use it in location with direct water contact. 3. Contains small parts keep away from children. Control ON Control OFF Adjust BrightnessColour temperature adjusting 1. Please read this the online guidels at support Minosto.com/Z-wave remote carefully. 2. Remove battery tabs. 3. Your Z-wave remove Immediately should flash LED to indicate it is powered. Power the device 1. Use by hand open the remote cap,and push it to separate the 2 halves.

Cover Letter(s)

Sincerely, Name/Title: Jianghai Nie/Manager Company: NIE-TECH CO., LTD Address: Jilian commercial center 9001, Jinxiu road No.2, Changan Town Dongguan City, Guangdong Province China Phone: 13751285558 Fax: 86 (769) 82286661 E-Mail: [email protected]

External Photos

FCC ID: 2AQURRF924 FCC ID: 2AQURRF924 FCC ID: 2AQURRF924

ID Label/Location Info

侧边缺口方向定位 RF remote Model: RF924-tx Battery: CR2032 Frequency: 433.92MHz FCC ID: 2AQURRF924 VER1.0 Made in China Date Code:

Internal Photos

FCC ID: 2AQURRF924 FCC ID: 2AQURRF924 ANT FCC ID: 2AQURRF924

Test Report

ReportNo.:RFI-LAB-RF-202211-KK44-1 QP030-E41 Page1of9 TestingReport CustomerName:NIE-TECHCo.,Ltd ProductName:RF924antenna SampleModel:RF924-ANT ReferenceStandard:GB/T9410-2008;ANSI/IEEEStd149-1979 IssueDate:2022.12.1 Engineer:Date: Auditor:Date: Approver:Date: ReportNo.:RFI-LAB-RF-202211-KK44-1 QP030-E41 Page2of9 Version VersionNo.DateDescriptionFormulateApproval A02022.12.1Forthefirsttime,formulateJacksonEason Contents 1.GeneralInformation.........................................................................................................................3 1.1Generalinformationoftestinginstitutions...........................................................................3 1.2Testingprinciple...................................................................................................................3 1.3Testequipment......................................................................................................................4 1.4Testenvironment...................................................................................................................4 1.5Statement..............................................................................................................................4 2.SampleInformation.........................................................................................................................5 2.1Clientinformation.................................................................................................................5 2.2DescriptionofEUT(S)..........................................................................................................5 2.3EUTappearance....................................................................................................................6 2.4EUTsetupphotooffreespaceOTAtesting.........................................................................6 3.TestResults......................................................................................................................................7 3.1Teststandard.........................................................................................................................7 3.2Testuncertainty.....................................................................................................................7 3.3Testdata................................................................................................................................8 3.3.1Typicalfreespaceefficiencyandgain......................................................................8 3.3.2Typicalfreespaceradiationpattern...........................................................................8 (Thefollowingisblank)................................................................................................................9 ReportNo.:RFI-LAB-RF-202211-KK44-1 QP030-E41 Page3of9 1.GeneralInformation 1.1Generalinformationoftestinginstitutions Name ShenzhenRFI-LABCommunicationTechnologyCo.,Ltd. Address 10/FA,LingyunBld,LiufangRoad,BaoanDistrict,Shenzhen Tel 13682621346 E-mail [email protected] Equipment AlltheequipmentusedinthereportisfixedinZoneB,WestSideof1/F,Building1, TingweiIndustrialPark,No.6LiufangRoad,Bao'anDistrict,Shenzhen 1.2Testingprinciple ReportNo.:RFI-LAB-RF-202211-KK44-1 QP030-E41 Page4of9 1.3Testequipment EquipmentModelNo.SerialNo.Manufacturer Calibration date Next calibration date OTATest System RayZone-5000 RFI-LAB-RF -D00 GTS2021.3.152023.3.14 Network Analyzer E5071C RFI-LAB-RF -D01 KEYSIGHT2022.5.132023.5.12 1.4Testenvironment Temperature 23.5°C Humidity 59%RH Pressure 100.13kPa 1.5Statement (1)Thetestresultsinthereportareonlyapplicabletothetestedsamplesandthetestedsamples workundertheenvironmentdescribedinthereport. (2)OnlyShenzhenRFI-LABCommunicationTechnologyCo.,Ltd.havetherighttomodifythe report,andthemodificationinformationshallbeannotatedintherevisionform. (3)Anyobjectiontothisreportshallberaisedwithin30daysafterformalconfirmationofthe report. (4)Thisreportisinvalidifthereisanyevidencethatthesampleinformationprovidedisfalsified. (5)Thereportisinvalidwithoutthesignatureoftheauditorandapprover. ReportNo.:RFI-LAB-RF-202211-KK44-1 QP030-E41 Page5of9 2.SampleInformation 2.1Clientinformation Name NIE-TECHCo.,Ltd Address / Contacts / Tel / E-mail / 2.2DescriptionofEUT(S) ProductName RF924antenna SampleModel RF924-ANT Size / SerialNo. / TestItem Antennagain;Radiationpatternandefficiency FrequencyRange 428MHz-438MHz ReceivedDate 2022.11.30 TestDate 2022.12.1 Remark ThelengthoftheRFcableis80mm ReportNo.:RFI-LAB-RF-202211-KK44-1 QP030-E41 Page6of9 2.3EUTappearance 2.4EUTsetupphotooffreespaceOTAtesting Planform Frontview ReportNo.:RFI-LAB-RF-202211-KK44-1 QP030-E41 Page7of9 3.TestResults 3.1Teststandard NameParameterMethodStandardno. Mobile communication antenna Antennagain Genericspecification forantennasusedinthe mobilecommunications GB/T 9410-2008 Radiationpattern Antenna Radiationefficiency IEEEStandardTest ProceduresforAntennas ANSI/IEEEStd 149-1979 Gainanddirectivity 3.2Testuncertainty TheuncertaintywascalculatedonthebasisoftheGUMpublishedbyISO,usingthe inclusionfactorofK=2andthe95%confidenceleveltoexpresstheextended uncertainty. ItemUncertainty Antennagain±0.72dB Radiationefficiency±0.72dB ReportNo.:RFI-LAB-RF-202211-KK44-1 QP030-E41 Page8of9 3.3Testdata 3.3.1Typicalfreespaceefficiencyandgain 3.3.2Typicalfreespaceradiationpattern (1)X-ZPlane: (2)Y-ZPlane: Frequency/MHz 428429430431432433434435436437438 PeakGain/dBi -9.33-9.22-9.20-9.03-9.01-8.86-8.81-8.72-8.62-8.42-8.32 Efficiency/% 3.974.064.164.224.304.434.524.624.754.905.03 ReportNo.:RFI-LAB-RF-202211-KK44-1 QP030-E41 Page9of9 (3)X-YPlane: (4)TypicalFreeSpace3DRadiationPatternat433MHz: -------------------------------------------------End------------------------------------------------ (Thefollowingisblank)

Test Report

Report No.: PTC22111805301E-FC01 Page 1 of 31 FCC TEST REPORT FCC ID: 2AQURRF924 Product : RF remote Model Name : RF924-TX Brand : N/A Report No. : PTC22111805301E-FC01 Prepared for NIE-TECH Co., Ltd Jinlian commercial center 9001, Jinxiu road No.2, Changan Town,Dongguan City, GuangDongProv., CHINA Prepared by Precise Testing & Certification Co., Ltd Building 1, No. 6, Tongxin Road, Dongcheng Street, Dongguan, Guangdong, China Report No.: PTC22111805301E-FC01 Page 2 of 31 1. TEST RESULT CERTIFICATION Applicant’s name : NIE-TECH Co., Ltd Address : Jinlian commercial center 9001, Jinxiu road No.2, Changan Town,Dongguan City, GuangDongProv., CHINA Manufacture's name : NIE-TECH Co., Ltd Address : Jinlian commercial center 9001, Jinxiu road No.2, Changan Town,Dongguan City, GuangDongProv., CHINA Product : RF remote Model : RF924-TX Standards : FCC CFR47 Part 15 Section 15.231 Test procedure : ANSI C63.10:2013 Test Date : Nov. 23, 2022 to Nov. 29, 2022 Date of Issue : Dec. 13, 2022 Test Result : Pass This device described above has been tested by PTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTC, this document may be altered or revised by PTC, personal only, and shall be noted in the revision of the document. Testing Engineer: Simon Pu/ Engineer Technical Manager: Ronnie Liu/ Manager Report No.: PTC22111805301E-FC01 Page 3 of 31 Contents Page 2 TEST SUMMARY .............................................................................................................................................. 4 3 GENERAL INFORMATION ............................................................................................................................. 5 3.1 GENERAL DESCRIPTION OF E.U.T. ......................................................................................................... 5 3.2 TEST MODE ............................................................................................................................................. 5 3.3 TEST SITE ................................................................................................................................................ 5 4 EQUIPMENT DURING TEST .......................................................................................................................... 6 4.1 EQUIPMENTS LIST ................................................................................................................................... 6 4.2 MEASUREMENT UNCERTAINTY ................................................................................................................ 6 5 CONDUCTED EMISSION ................................................................................................................................ 7 5.1 E.U.T. OPERATION .................................................................................................................................. 7 5.2 EUT SETUP ............................................................................................................................................. 7 5.3 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION)......................................................................... 8 5.4 MEASUREMENT PROCEDURE .................................................................................................................. 8 5.5 CONDUCTED EMISSION LIMIT .................................................................................................................. 8 5.6 MEASUREMENT DESCRIPTION................................................................................................................. 8 5.7 CONDUCTED EMISSION TEST RESULT .................................................................................................... 8 6 PERIODIC OPERATION .................................................................................................................................. 9 7 RADIATED SPURIOUS EMISSIONS .......................................................................................................... 13 7.1 EUT OPERATION ................................................................................................................................... 14 7.2 TEST SETUP .......................................................................................................................................... 15 7.3 SPECTRUM ANALYZER SETUP............................................................................................................... 16 7.4 TEST PROCEDURE ................................................................................................................................. 17 7.5 SUMMARY OF TEST RESULTS ............................................................................................................... 18 8 20DB BANDWIDTH MEASUREMENT ........................................................................................................ 22 8.1 TEST PROCEDURE ................................................................................................................................. 22 8.2 TEST RESULT ........................................................................................................................................ 23 9 ANTENNA REQUIREMENT .......................................................................................................................... 24 10 TEST SETUP ................................................................................................................................................. 25 11 EUT PHOTOS ................................................................................................................................................ 26 Report No.: PTC22111805301E-FC01 Page 4 of 31 2 Test Summary Test Items Test Requirem…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2AQURRF924 Radiated Emissions From 30MHz-1000MHz Test frequency from Above 1GHz

Contact Information

Applicant

Jianghai Nie(Manager)
[email protected]13751285558Fax: 86 (769) 82286661

Test Firm

Precise Testing & Certification Co., LTD.Chris Du
[email protected]+86-769-38808222

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from NIE-TECH CO., LTD

2 Button Remote ON/ON - FCC ID 2AQUR-RF922 - NIE-TECH CO., LTD
2AQUR-RF922

2 Button Remote ON/ON

Jun 10, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
ON/OFF SWITCH 800 - FCC ID 2AQUR-ZW305Z - NIE-TECH CO., LTD
2AQUR-ZW305Z

ON/OFF SWITCH 800

Mar 03, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wi-Fi Countdown Timer Switch - FCC ID 2AQURNHT06W - NIE-TECH CO., LTD
2AQURNHT06W

Wi-Fi Countdown Timer Switch

Jun 26, 2024

Equipment Class

DTS - Digital Transmission System
Wi-Fi Countdown Timer Switch - FCC ID 2AQURNHTO6W - NIE-TECH CO., LTD
2AQURNHTO6W

Wi-Fi Countdown Timer Switch

Jun 26, 2024

Equipment Class

DTS - Digital Transmission System
Z-Wave Mini Smart Plug (800S) - FCC ID 2AQURZW37MU - NIE-TECH CO., LTD
2AQURZW37MU

Z-Wave Mini Smart Plug (800S)

Mar 08, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter