Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
OTHER WARNINGS Risk of Fire Risk of Electrical Shock Risk of Burns MEDICAL EQUIPMENT Electrical Code and local regulations in Canada. If you are unsure or 2+ ,*#,/1)",21-"/#,/*&+$1%&0&+01))1&,+ ,+02)1.2)&Ɯ"! CAUTION - PLEASE READ! This device is intended for installation in accordance with the National Electric Code and local regulations in the United States, or the Canadian electrician. CONTROLLING APPLIANCES Please exercise EXTREME CAUTION when using Z-Wave devices to control appliances. Reason being is because the appliance you want to control may be in a separate room and if unintentional behavior occurs ț02 %0!"3& "12/+&+$,+,/,ƛȒ"&1%"/&+1"+1&,+))63&0 %"!2)"0Ǿ,/ unintentionally via network error) this event may lead to a hazardous condition. For these reasons, please note the following suggestions: 1) Do not include Z-Wave devices in Groups or Scenes if they control appliances. 2) Do not use Z-Wave devices to control electric heaters or any other appliances which may present a hazardous condition due to unattended, unintentional, or automatic power control. WARNING - SHOCK HAZARD TURN OFF THE POWER 1,1%" &/ 2&1#,/1%"04&1 %+!)&$%1&+$Ɯ512/"1 the service panel (circuit breaker) prior to installation. ALL WIRING CONNECTIONS MUST BE MADE WITH THE POWER OFF to avoid personal injury and/or damage to the switch. Model: ZKS31 Power: 125VAC, 60Hz Frequency: 908.42 MHz Maximum Load: 150W LED, 500W Please DO NOT use this switch to control Medical or Life Support ".2&-*"+1ǽȒ3"!"3& "00%,2)!+"3"/"20"!1, ,+1/,)1%"+ȡƛ status of Medical and/or Life Support equipment. incandescent țǘǕǕ4&1%,1%0&!"0,#%"10&+(10,ƛȜ Minimum Load: 5W for LED bulbs Range: Up to 100 feet line of sight Operating Temperature Range: 32-104° F (0-40° C) For indoor use. -" &Ɯ 1&,+002'" 11, %+$"4&1%,21+,1& " due to continuing product improvement --/,3)ǿȒ3")20"/1&Ɯ"! switch x1 V1.0 2020.12 Z-WAVE INTEROPERABILITY This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applica- tions. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network. This Device supports Lifeline (association group 1) supporting 1 node for lifeline communication. Group 1 must be assigned the Node ID of the primary controller where unsolicited notifications will be sent. The Z-Wave controller should set this 00, &1&,+21,*1& ))6ƞ"/&+ )20&,+ǽ Lifeline association only supports the “Device Reset Locally” function. Refer to the instructions of your controller for any available details on how this can be set. wiring x1screws x2 Part 1. Introduction Contents A quick note before we give out the wiring schematics. Please do not try installing this device if you are unsure of how electrical circuits operate within your home. As exciting as it is to have a smart switch installed, it can be dangerous and even life-threatening if you do not install this ,//" 1)6ǽ)"0" ,+02)1.2)&Ɯ"!")" 1/& &+&#+" "00/6ǽ&1%1%10&!Ǿ%"/"/"#"4,1%"/4/+&+$04"ȉ!)&("1,-,&+1,21#,/6,2/0#"16ǿ A Few Quick Reminders Note before installation 1) The Z-Wave In-wall Smart Switch must not exceed 150W LED, 500W incandescent. 2) Work with /"$2)/ǘȒ46,+ȡ,ƛ #,/Ǘ), 1&,+0 ,+1/,)ǽ 1 +,+)6" ,++" 1"!4&1%/"$2)/ǘȒ46,+ȡ,ƛ04&1 %Ǿdon't use a smart switch or a dimmer switch! Couldn't work with an add-on switch! 3) The colors of your wires may not match the ones in our diagrams so please make sure you've identified all wires correctly based on their source, not color only. 4) Please check your original 3-way wiring circuit in your home before installation, and then follow the wiring diagram option 1 or 2 in the manual. 5) Install the smart switch in the switch box which directly connects to the power Line and Neutral. 6) This switch requires a Neutral for installation, or the installation will not succeed. 7) Not recommended for fan. ConventionDescriptionConventionDescription • Locally button function • LED Indicator ș21,2/+Ȓƛ&*"/ ș21,2/+Ȓ+&*"/ ș"01,/"0011"ƞ"/-,4"/#&)2/" ș&**"/0-""!țȡ ,+1/,)Ȝ ș&**"/0-""!ț,+)6#,/), )-/"00ǔ%,)!Ȝ ș2)1&)"3")*&+&*2*3)2" +"0"1 ș2)1&)"3")*5&*2*3)2" +"0"1 ș00, &1&,+ /,2- ș, ))6211,+/"00#2+ 1&,+ ș,**+! )00"0 Function description •&+!& 1,/ȡ211,+#2+ 1&,+ •!!&+$ȡ/"0"11%"!"3& "ț 1,/60"11&+$Ȝ •&/&+$&+01/2 1&,+0 •&+$)"-,)"+!ǘȒ464&/&+$!&$/* • !!&+$"3& ",Ȓ3""14,/( • ,"*,3"%""3& " • ,"12/+%""3& ", 1,/6"#2)10 • 00, &1&,+ /,2- • Product introduction • +01))1&,+01"-0 Part 1. Introduction Part 2. &/&+$&$/* Part 2. &/&+$&$/* Part 4. +2),+1/,) /1ǘǽ "14,/(,+#&$2/1&,+ •,)21&,+01,0,*" ,**,+-/,)"*0 Part 6. /,2)"0%,,1&+$ HOW TO INSTALL THE WIRES ǘǽ ǘȡǝȒǖȡǗȋ 1. Unscrew: carefully turn the screw counterclockwise to leave enough space for the wire to be inserted. Do not unscrew the screws completely. 2. Press down: Once loosened, use your finger so it catches the thread. 3. Insert the wire: make sure the wire is completely straight, then insert it into the terminal while holding down the screw. Do not wrap the wire around the screw! 4. Tighten: Turn the screw clockwise to tighten the wire. Make sure the wires are locked! Note: There are 2 holes for each terminal can be used in the connection.You can use a jump wire or the second hole at the terminal to connect. 2. Line (hot) — black (connected to power) Neutral — white Load — black (connected to lighting) Traveler — red/other (only in 3-way installations) Line Load Ground Traveler Neutral 1. 4. Basic Operation The connected light can be turned ON/OFF in two ways: 1. Manually from of the In-wall Switch 2. Remotely with a Z-Wave Controller Manual Cont…
Text truncated - open the document above for the full version.
Sincerely, Name/Title: Jianghai Nie/Manager Company: NIE-TECH CO., LTD Address: Jilian commercial center 9001, Jinxiu road No.2, Changan Town Dongguan City, Guangdong Province China Phone: 13751285558 Fax: 86 (769) 82286661 E-Mail: [email protected]
FCCID:2AQURZKS31 FCCID:2AQURZKS31 FCCID:2AQURZKS31
FCC ID:2AQURZKS31 FCC ID:2AQURZKS31 ANT FCC ID:2AQURZKS31
ReportNo.:RFI-LAB-RF-202211-KK44-2 QP030-E11 Page1of10 TestingReport CustomerName:NIE-TECHCo.,Ltd ProductName:ZKS31antenna SampleModel:ZKS31-ANT ReferenceStandard:GB/T9410-2008;ANSI/IEEEStd149-1979 IssueDate:2022.12.1 Engineer:Date: Auditor:Date: Approver:Date: ReportNo.:RFI-LAB-RF-202211-KK44-2 QP030-E11 Page2of10 Version VersionNo.DateDescriptionFormulateApproval A02022.12.1Forthefirsttime,formulateJacksonEason Contents 1.GeneralInformation.........................................................................................................................3 1.1Generalinformationoftestinginstitutions...........................................................................3 1.2Testingprinciple...................................................................................................................3 1.3Testequipment......................................................................................................................4 1.4Testenvironment...................................................................................................................4 1.5Statement..............................................................................................................................4 2.SampleInformation.........................................................................................................................5 2.1Clientinformation.................................................................................................................5 2.2DescriptionofEUT(S)..........................................................................................................5 2.3EUTappearance....................................................................................................................6 2.4EUTsetupphotooffreespaceOTAtesting.........................................................................7 3.TestResults......................................................................................................................................8 3.1Teststandard.........................................................................................................................8 3.2Testuncertainty.....................................................................................................................8 3.3Testdata................................................................................................................................9 3.3.1Typicalfreespaceefficiencyandgain......................................................................9 3.3.2Typicalfreespaceradiationpattern...........................................................................9 (Thefollowingisblank)..............................................................................................................10 ReportNo.:RFI-LAB-RF-202211-KK44-2 QP030-E11 Page3of10 1.GeneralInformation 1.1Generalinformationoftestinginstitutions Name ShenzhenRFI-LABCommunicationTechnologyCo.,Ltd. Address 10/FA,LingyunBld,LiufangRd,BaoanDistrict,SZ Tel 13682621346 E-mail [email protected] Equipment Alltheequipmentusedinthereportisfixedin 10/FA,LingyunBld,LiufangRd,BaoanDistrict,SZ 1.2Testingprinciple ReportNo.:RFI-LAB-RF-202211-KK44-2 QP030-E11 Page4of10 1.3Testequipment EquipmentModelNo.SerialNo.Manufacturer Calibration date Next calibration date 16probe microwave chamber 3*3*2.5 RFI-LAB-RF -A00 SUNYIELD2021.3.152023.3.14 Network Analyzer E5071C RFI-LAB-RF -A02 Agilent 2022.5.132023.5.12 1.4Testenvironment Temperature 24.2°C Humidity 59%RH Pressure 100.18kPa 1.5Statement (1)Thetestresultsinthereportareonlyapplicabletothetestedsamplesandthetestedsamples workundertheenvironmentdescribedinthereport. (2)OnlyShenzhenRFI-LABCommunicationTechnologyCo.,Ltd.havetherighttomodifythe report,andthemodificationinformationshallbeannotatedintherevisionform. (3)Anyobjectiontothisreportshallberaisedwithin30daysafterformalconfirmationofthe report. (4)Thisreportisinvalidifthereisanyevidencethatthesampleinformationprovidedisfalsified. (5)Thereportisinvalidwithoutthesignatureoftheauditorandapprover. ReportNo.:RFI-LAB-RF-202211-KK44-2 QP030-E11 Page5of10 2.SampleInformation 2.1Clientinformation Name NIE-TECHCo.,Ltd Address / Contacts / Tel / E-mail / 2.2DescriptionofEUT(S) ProductName ZKS31antenna SampleModel ZKS31-ANT Size / SerialNo. / TestItem Antennagain;Radiationpatternandefficiency FrequencyRange 903MHz-913MHz ReceivedDate 2022.11.30 TestDate 2022.11.30 Remark ThelengthoftheRFcableis80mm ReportNo.:RFI-LAB-RF-202211-KK44-2 QP030-E11 Page6of10 2.3EUTappearance ReportNo.:RFI-LAB-RF-202211-KK44-2 QP030-E11 Page7of10 2.4EUTsetupphotooffreespaceOTAtesting Planform Frontview ReportNo.:RFI-LAB-RF-202211-KK44-2 QP030-E11 Page8of10 3.TestResults 3.1Teststandard NameParameterMethodStandardno. Mobile communication antenna Antennagain Genericspecification forantennasusedinthe mobilecommunications GB/T 9410-2008 Radiationpattern Antenna Radiationefficiency IEEEStandardTest ProceduresforAntennas ANSI/IEEEStd 149-1979 Gainanddirectivity 3.2Testuncertainty TheuncertaintywascalculatedonthebasisoftheGUMpublishedbyISO,usingthe inclusionfactorofK=2andthe95%confidenceleveltoexpresstheextended uncertainty. ItemUncertainty Antennagain±1dB Radiationefficiency±10% ReportNo.:RFI-LAB-RF-202211-KK44-2 QP030-E11 Page9of10 3.3Testdata 3.3.1Typicalfreespaceefficiencyandgain 3.3.2Typicalfreespaceradiationpattern (1)X-ZPlane: (2)Y-ZPlane: Frequency/MHz 903904905906907908909910911912913 PeakGain/dBi -5.97-5.97-5.99-5.94-5.91-5.93-5.92-5.91-5.93-5.96-5.94 Efficiency/% 11.4811.4011.2711.3111.2811.1611.1211.0811.0210.9310.98 ReportNo.:RFI-LAB-RF-202211-KK44-2 QP030-E11 Page10of10 (3)X-YPlane: (4)TypicalFreeSpace3DRadiationPatternat908MHz: -------------------------------------------------End------------------------------------------------ (Thefollowingisblank)
Report No.: PTC22111805302E-FC01 Page 1 of 33 FCC TEST REPORT FCC ID:2AQURZKS31 Product Name : 3-Way Z-Wave Smart Dimmer Switch Model Name : ZKS31 Brand Name : N/A Report No. : PTC22111805302E-FC01 Prepared for NIE-TECH Co., Ltd Jinlian commercial center 9001, Jinxiu road No.2, Changan Town,Dongguan City, GuangDongProv., CHINA Prepared by Precise Testing & Certification Co., Ltd. Building 1, No. 6, Tongxin Road, Dongcheng Street, Dongguan, Guangdong, China Report No.: PTC22111805302E-FC01 Page 2 of 33 1 TEST RESULT CERTIFICATION Applicant’s name : NIE-TECH Co., Ltd Address : Jinlian commercial center 9001, Jinxiu road No.2, Changan Town,Dongguan City, GuangDongProv., CHINA Manufacture's name : NIE-TECH Co., Ltd Address : Jinlian commercial center 9001, Jinxiu road No.2, Changan Town,Dongguan City, GuangDongProv., CHINA Product name : 3-Way Z-Wave Smart Dimmer Switch Model name : ZKS31 Standards : FCC Part15 Subpart C, Paragraph 15.249 Test procedure : ANSI C63.10: 2013 Test Date : Nov. 23, 2022 to Dec. 13, 2022 Date of Issue : Dec. 22, 2022 Test Result : Pass This device described above has been tested by PTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTC, this document may be altered or revised by PTC, personal only, and shall be noted in the revision of the document. Test Engineer: Simon Pu/Engineer Technical Manager: Ronnie Liu/Manager Report No.: PTC22111805302E-FC01 Page 3 of 33 Contents Page 1 TEST RESULT CERTIFICATION .............................................................................................................................. 2 2 TEST SUMMARY ......................................................................................................................................................... 4 3 TEST FACILITY ............................................................................................................................................................ 5 4 GENERAL INFORMATION ........................................................................................................................................ 6 4.1 GENERAL DESCRIPTION OF E.U.T. .................................................................................................................... 6 4.2 TEST MODE ........................................................................................................................................................ 7 4.3 LIST OF CHANNELS ............................................................................................................................................. 8 5 EQUIPMENT DURING TEST ..................................................................................................................................... 9 5.1 EQUIPMENTS LIST .............................................................................................................................................. 9 5.2 MEASUREMENT UNCERTAINTY ......................................................................................................................... 11 5.3 DESCRIPTION OF SUPPORT UNITS ................................................................................................................... 12 6 TEST STANDARD AND LIMIT ............................................................................................................................... 13 6.1. TEST SETUP .................................................................................................................................................... 13 6.2. TEST PROCEDURE ........................................................................................................................................... 13 6.3. TEST DATA ...................................................................................................................................................... 14 7 . RADIATED EMISSION AND BAND EDGE ......................................................................................................... 16 7.1. TEST STANDARD AND LIMIT ............................................................................................................................ 16 7.2. TEST SETUP .................................................................................................................................................... 17 7.3. TEST PROCEDURE ........................................................................................................................................... 18 7.4. TEST DATA ...................................................................................................................................................... 19 8. 20DB BANDWIDTH TEST ....................................................................................................................................... 23 8.1. TEST STANDARD AND LIMIT ............................................................................................................................ 23 8.2. TEST SETUP .................................................................................................................................................... 23 8.3. TEST PROCEDURE ........................................................................................................................................... 23 8.4. TEST DATA ...................................................................................................................................................... 23 9. ANTENNA REQUIREMENT .................................................................................................................................... 25 9.1. TEST STANDARD AND REQUIREMENT .........................................................................................................…
Text truncated - open the document above for the full version.
CONDUCTEDEMISSIONTEST RadiatedEmissions From30MHz-1000MHz TestfrequencyfromAbove1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 908.42 MHz - 908.42 MHz | - |

2 Button Remote ON/ON
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
ON/OFF SWITCH 800
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wi-Fi Countdown Timer Switch
Equipment Class
DTS - Digital Transmission System
Wi-Fi Countdown Timer Switch
Equipment Class
DTS - Digital Transmission System
Z-Wave Mini Smart Plug (800S)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter