Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FANTEMEngineeringSpecification Page1 ZW700Module UserManual FANTEMEngineeringSpecification Page2 1FEATURES&SPECIFICATIONS 1.1HardwareCharacteristics ParameterValue Z-WaveModuleZW700 Z-WaveAntennaDistance40m(Indoor)/150m(Outdoor) IndicatorLightColor1red,1green(atthekeypad) BatteryInfoAAalkalinebatteryx4 WorkingCurrentZ-WaveModule:10mA(WakeUp),40mA(Sendmessage) StandbyCurrentZ-WaveModule:24uA 1.2SoftwareCharacteristics ParameterValue WirelessTechnologyZ-Wave CertificationType Z-WavePlus™v2 Z-WaveSDKVersion7.18.1 Z-WaveLibraryTypeEnhanced232Slave Z-WaveRoleTypeZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_SLEEPING_LISTENING(0x07) GenericDeviceTypeGENERIC_TYPE_ENTRY_CONTROL(0x40) SpecificDeviceTypeSPECIFIC_TYPE_DOOR_LOCK(0x01) SecurityClassNon-Security,S0,S2-ACCESS SmartStart Support.Afterpoweringon,SmartStartisautoactiveifit ’ soutofthe Z-Wavenetwork. OverTheAir(OTA)Support.FirmwarecanbeupdatedviaRF. MultichannelDeviceNo AssociationSupport.RefertoSection4.7AssociationGroupInfo. FANTEMEngineeringSpecification Page3 FactoryResetSupport.RefertoSection3.6Howtofactoryreset. Power-downMemorySupport.Allcommandsettingswillstayunchangedevenpowerdown. TimedbatteryreportSupport.RefertoConfigurationParameter3. LowbatterywarningSupport. DoorStateReportSupport.Whendoorlockmodechanged,sendoutnotificationviaGroup1. UsercodeReportSupport.Whenusercodechanged,sendoutnotificationviaGroup1. FANTEMEngineeringSpecification Page4 PRODUCTQUICKSTART 1.3AboutisZ-Wave Z-WaveistheinternationalwirelessprotocolforcommunicationintheSmartHome. Z-Waveensuresareliablecommunicationbyreconfirmingeverymessage(two-waycommunication)andeverymains powerednodecanactasarepeaterforothernodes(meshednetwork)incasethereceiverisnotindirect wirelessrangeofthetransmitter. ThisdeviceandeveryothercertifiedZ-WavedevicecanbeusedtogetherwithanyothercertifiedZ-Wave deviceregardlessofbrandandoriginaslongasbotharesuitedforthesamefrequencyrange. 1.4AboutSmartStart SmartStartenabledproductscanbeaddedintoaZ-WavenetworkbyscanningtheZ-WaveQRCodepresentonthe productwithacontrollerprovidingSmartStartinclusion.NofurtheractionisrequiredandtheSmartStart productwillbeaddedautomaticallywithin10minutesofbeingswitchedoninthenetworkvicinity. 1.5HowtoaddtheproductintoZ-Wavenetwork 1.Followtheuserguideofhubtoenterinclusionmode. 2.Operateonlockfollowingguidebelow: 1)Entermastermode(**+MasterPINCode+#) 2)Input"0"toenter"Networksettings" 3)Input"1"+"#"toenter"Includemode" 1.6HowtoremovetheproductfromZ-Wavenetwork 1.Followtheuserguideofhubtoenterexclusionmode. 2.Operateonlockfollowingguidebelow: 1)Entermastermode(**+MasterPINCode+#) 2)Input"0"toenter"Networksettings" 3)Input"2"+"#"toenter"Exclusionmode" 1.7Howtofactoryreset 1.Operationsonlock 1)Keepyourlockin"unlock"status. 2)Usetheprovidedresetpintopressandholdtheresetbuttonformorethan5secondsuntilhearingbeep sound. 3)Ifresetissuccessful,theboltwillextendonitsowntolearntheorientationofthedoor. 2.Pleaseusethisprocedureonlywhenthenetworkprimarycontrollerismissingorotherwiseinoperable. 3.Defaultmasterpincodeis“12345678”,pleasemodifyitafterreset(Refertoprogramminginstruction). FCC Caution: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna. IC Caution: RSS-Gen Issue 5 "&" RSS-Gen numéro 5 - English: This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. RF exposure statement: The equipment complies with IC Radiation exposure limit set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. - French: Cet appareil contient des émetteurs / récepteurs exemptés de licence conformes aux RSS (RSS) d' Innovation, Sciences et Développement économique Canada. Le fonctionnement est soumis aux deux conditions suivantes: (1) Cet appareil ne doit pas causer d'interférences. (2) Cet appareil doit accepter toutes les interférences, y compris celles susceptibles de provoquer un f…
Text truncated - open the document above for the full version.
Shenzhen Kaadas Intelligent Technology Co.,Ltd 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type • Company name: Shenzhen Kaadas Intelligent Technology Co.,Ltd Address: Floor 11, Building B2, Phase 2, Creative City, Xiandong Road, Xili Community, Xili Street, Nanshan District, Shenzhen, Guangdong, China Product Name: Z-Wave Module FCCID: 2AQY4-ZW700 Model(s): ZW700 2.911(d)(5)(i) EquipmentType We, [Shenzhen Kaadas Intelligent Technology Co.,Ltd] (“the applicant”) certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. • Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: Jing Rao Date: 2023-03-29 Title and Company name: Product manager /Shenzhen Kaadas Intelligent Technology Co.,Ltd NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
ShenzhenKaadasIntelligentTechnologyCo.,Ltd 2.911(d)(5)(ii)ApplicantAttestationv1.2 Section2.911(d)(5)(ii)Certification–Applicant(CoveredList) Yourssincerely Company name: Shenzhen Kaadas Intelligent Technology Co.,Ltd Address: Floor 11, Building B2, Phase 2, Creative City, Xiandong Road, Xili Community, Xili Street, Nanshan District, Shenzhen, Guangdong, China Product Name: Z-Wave Module FCC ID: 2AQY4-ZW700 Model(s): ZW700 2.911(d)(5)(ii) Applicant filing We, Shenzhen Kaadas Intelligent Technology Co.,Ltd (“Jing Rao”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 , established pursuant to § 1.50002 of this chapter, as an entity producing covered communications equipment. , Name:JingRaoDate:2023-03-29 TitleandCompanyname:Productmanager/ShenzhenKaadasIntelligentTechnologyCo.,Ltd NOTE1 Deleteoptionnotapplicabletothisapplication. NOTE2 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
IdlespaceTechnologyCompanyCo.,LTD 2.911(d)(7)USAAgentv1.3 Section2.911(d)(7)USAAgentforServiceofProcess We,ShenzhenKaadasIntelligentTechnologyco.,Ltd.designate [IdlespaceTechnologyCompanyCo.,LTD]forthepurposeofacceptingserviceof processonbehalfoftheapplicant Company name:Shenzhen Kaadas Intelligent Technology co., Ltd. Address:Floor11,BuildingB2,Phase2,CreativeCity,XiandongRoad,XiliCommunity,XiliStreet, NanshanDistrict,Shenzhen,Guangdong,China Product Name:Z-Wave Module FCC ID: 2AQY4-ZW700 Model(s):ZW700 2.911(d)(7) USA Designated Agent for Service of Process . Applicantconsent:WeAcknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminated allmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolving theequipment,whicheverislater. Agentobligation:WeAcknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,ortheconclusionofanyCommission-relatedadministrativeorjudicial proceedinginvolvingtheequipment,whicheverislater. USAAgent Companyname:IdlespaceTechnology CompanyCo.,LTD Address:605SMillikenAveUnitA,Ontario CA91761 FRN:0033422346 Contact Name: Yuxiang Zhang Telephone No: +1(213)-3628739 Email: [email protected] Signature Applicant Company name: Shenzhen Kaadas Intelligent Technology co., Ltd. Address: Floor11,BuildingB2,Phase2,CreativeCity , XiandongRoad,XiliCommunity,XiliStreet, NanshanDistrict,Shenzhen,Guangdong,China : FCC Grantee Code: 2AQY4 Contact Name: Jing Rao Telephone No: +86-755-86668868 Email: [email protected] Signature: IdlespaceTechnologyCompanyCo.,LTD 2.911(d)(7)USAAgentv1.3 Title:OperationsManagerTitle:BusinessDirector Date:3/24/2023Date:3/24/2023 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the
Shenzhen Kaadas Intelligent Technology Co.,Ltd Agent Authorization We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named Company: Shenzhen Kaadas Intelligent Technology Co.,Ltd Address:Floor 11, Building B2, Phase 2, Creative City, Xiandong Road, Xili Community, Xili Street, Nanshan District, Shenzhen, Guangdong, China Product Name: Z-Wave Module Trade Mark: N/A Model Number(s): ZW700 FCC ID: 2AQY4-ZW700 equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2023-03-29 Name: Jing Rao Title: Product manager Company: Shenzhen Kaadas Intelligent Technology Co.,Ltd
Shenzhen Kaadas Intelligent Technology Co.,Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2023-03-29 Subject; Request for Confidentiality FCC ID: 2AQY4-ZW700 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Jing Rao Title: Product manager
Page1of3FCCID:2AQY4-ZW700 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of3FCCID:2AQY4-ZW700 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of3FCCID:2AQY4-ZW700 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6
Page1of1FCCID:2AQY4-ZW700 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L:1.5cmxW:1.7cm) LabelLocation Model:ZW700 FCCID:2AQY4-ZW700
Page1of3FCCID:2AQY4-ZW700 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of3FCCID:2AQY4-ZW700 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of3FCCID:2AQY4-ZW700 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Antenna
Page1of3FCCID:2AQY4-ZW700 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCRFExposureEvaluation 1.ProductInformation ProductnameZ-WaveModule TestModelZW700 PowerSupply DC3V HardwareVersionZHI99AA SoftwareVersionV1.3 FrequencyRange908.4MHz~916MHz ModulationTypeGFSK AntennaDescriptionFPCAntenna,0dBi(Max.) Exposurecategory Generalpopulation/uncontrolledenvironment EUTType ProductionUnit DeviceType ImmobilizationDevices Page2of3FCCID:2AQY4-ZW700 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2.EvaluationmethodandLimit SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensures thatthepublicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobile devicewherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelow RFPermissibleExposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesum oftheMPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPE ratioofeachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperating configurationsandexposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpower densitytoMPElimit,atthetestfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrom measurementsornumericalsimulationsmaybeusedtodeterminetheMPEratios.Spatialaveragingdoesnot applywhenMPEisestimatedusingsimplecalculationsbasedonfar-fieldplane-waveequivalentconditions. Theantennainstallationandoperatingrequirementsforthehostdevicemustmeettheminimumtest separationdistancesrequiredbyallantennas,inbothstandaloneandsimultaneoustransmissionoperations, tosatisfycompliance. 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–2019:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoElectric,Magnetic, andElectromagneticFields,0Hzto300GHz FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRF ExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices. 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/UncontrolledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity Page3of3FCCID:2AQY4-ZW700 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 4.ConductedPower TestProcedure TXfrequencyrange:908.40MHz-916MHz Devicecategory:ImmobilizationDevices(Distance:20cm) Max.FieldStrength:105.81dBuV/m@3m EIRP=E-104.7+20logD=105.81-104.7+20log3=10.65dBm MaximumConductedOutputPower:10.65dBm Turn-up:10.0±1 5.EvaluationResults AsdeclaredbytheApplicant,theEUTisawirelessdeviceusedinafixapplication,atleast20cmfromany bodypartoftheuserornearbypersons;fromthemaximumEUTRFoutputpower,theminimumseparation distance,r=20cm,aswellasthegainoftheusedantennarefertoantennainformation,theRFpowerdensity canbeobtained. 6.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1091fortheuncontrolledRFExposureof mobiledevice. .......................THEENDOFREPORT......................... Band/Mode RFoutputpower AntennaGain (dBi) MPE (mW/cm2) MPE Limits (mW/cm2) dBmmW GFSK1112.5900.00250.605
ProfessionalAntennaServiceProvider SHENZHENFEIMINTECHNOLOGYCO.,LTD. SHENZHENFEIMINTECHNOLOGYCO.,LTD. Antennatestreport KDS Test Revie Model Manufacturer w Time 2022-12-21 TEL:0755-23035723Mail:[email protected]:www.fmant.cn Weiquan Xieyichao Shenzhen Kaadas Intelligent Technology Co.,Ltd SHENZHENFEIMINTECHNOLOGYCO.,LTD. Testequipmentandtestenvironment TEL:0755-23035723Mail:[email protected]:www.fmant.cn SHENZHENFEIMINTECHNOLOGYCO.,LTD. Testequipment Maintestindicators Passiveindicator Gain Efficiency 3Ddirectionmap Activeindicator TRPtotalradiatedpower TIStotalreceiversensitivity ProbeMicrowaveAnechoicChamber Frequency:0.4GHzto6GHz TEL:0755-23035723Mail:[email protected]:www.fmant.cn SHENZHENFEIMINTECHNOLOGYCO.,LTD. Testequipment AgilentE5071CVectorNetwork Analyzer R&SCMW500BroadbandWireless CommunicationTester GSM/3G/4G WIFI/Bluetooth NB-IoT Frequency:300kHzto8.5GHz TEL:0755-23035723Mail:[email protected]:www.fmant.cn SHENZHENFEIMINTECHNOLOGYCO.,LTD. Testphotos TEL:0755-23035723Mail:[email protected]:www.fmant.cn SHENZHENFEIMINTECHNOLOGYCO.,LTD. Passiveantennadata Antennainstallationlocationand method.Coaxialcable:0.81*35mm,oneend with4thgenerationipex,oneendstripped 2-2-1.5 TEL:0755-23035723Mail:[email protected]:www.fmant.cn SHENZHENFEIMINTECHNOLOGYCO.,LTD. AntennaSWR On-The-FlySensitive DebugAntenna TEL:0755-23035723Mail:[email protected]:www.fmant.cn SHENZHENFEIMINTECHNOLOGYCO.,LTD. AntennaReturnloss On-The-FlySensitive DebugAntenna TEL:0755-23035723Mail:[email protected]:www.fmant.cn SHENZHENFEIMINTECHNOLOGYCO.,LTD. Antennagainandefficiency On-The-FlySensitive DebugAntenna Antenna Efficiency Freq(MHz)Gian(dBi) (%) 32.85 31.87 32.05 32.17 32.17 32.01 32.01 32.02 32.02 32.07 32.2 908 916 917 918 919 920 921 922 923 924 9254 -0. -0.29 0.00 -0.15 -0.14 -0.12 -0.14 -0.17 -0.19 2 -0.21 -0.19 TEL:0755-23035723Mail:[email protected]:www.fmant.cn SHENZHENFEIMINTECHNOLOGYCO.,LTD. AntennaRadiationPattern On-The-FlySensitive DebugAntenna TEL:0755-23035723Mail:[email protected]:www.fmant.cn SHENZHENFEIMINTECHNOLOGYCO.,LTD. AntennaSWR Customer'soriginalantenna TEL:0755-23035723Mail:[email protected]:www.fmant.cn SHENZHENFEIMINTECHNOLOGYCO.,LTD. AntennaReturnloss Customer'soriginalantenna TEL:0755-23035723Mail:[email protected]:www.fmant.cn Productfigure Thanksforyoursupport! TEL:(86)755-23035723.FAX:0755-23036702 E-mail:[email protected] ADD:303 , buildingC,GUSHUHengnanRoad,Xixiang,BaoandistrictShenzhen
Page1of33FCCID:2AQY4-ZW700ReportNo.:LCSA030323156EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FOR ShenzhenKaadasIntelligentTechnologyCo.,Ltd Z-WaveModule TestModel:ZW700 Preparedfor:ShenzhenKaadasIntelligentTechnologyCo.,Ltd Address: Floor11,BuildingB2,Phase2,CreativeCity,XiandongRoad,Xili Community,XiliStreet,NanshanDistrict,Shenzhen,Guangdong,China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:March09,2023 Numberoftestedsamples:2 SampleNo.:A030323156-1,A030323156-2 Serialnumber:Prototype DateofTest:March09,2023~March22,2023 DateofReport:March22,2023 Page2of33FCCID:2AQY4-ZW700ReportNo.:LCSA030323156EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.249) ReportReferenceNo......................:LCSA030323156EA DateofIssue.......................................:March22,2023 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd.. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:ShenzhenKaadasIntelligentTechnologyCo.,Ltd Address................................................: Floor11,BuildingB2,Phase2,CreativeCity,XiandongRoad,Xili Community,XiliStreet,NanshanDistrict,Shenzhen,Guangdong, China TestSpecification Standard..............................................:FCCCFR47PART15C(15.249)/ANSIC63.10:2013 TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription.....................:Z-WaveModule TradeMark..........................................: N/A TestModel...........................................:ZW700 Ratings.................................................:DC3V Result..................................................: Positive Compiledby:Supervisedby:Approvedby: RoryHuang/AdministratorCaryLuo/TechniqueprincipalGavinLiang/Manager Page3of33FCCID:2AQY4-ZW700ReportNo.:LCSA030323156EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. TestReportNo.:LCSA030323156EA March22,2023 Dateofissue TestModel..............................:ZW700 EUT.........................................:Z-WaveModule Applicant...............................:ShenzhenKaadasIntelligentTechnologyCo.,Ltd Address..................................: Floor11,BuildingB2,Phase2,CreativeCity,XiandongRoad,Xili Community,XiliStreet,NanshanDistrict,Shenzhen,Guangdong, China Telephone...............................:/ Fax..........................................:/ Manufacturer........................:ShenzhenKaadasIntelligentTechnologyCo.,Ltd Address...................................:Floor11,BuildingB2,Phase2,CreativeCity,XiandongRoad,Xili Community,XiliStreet,NanshanDistrict,Shenzhen,Guangdong, China Telephone...............................:/ Fax..........................................:/ Factory...................................: ShenzhenKaadasIntelligentTechnologyCo.,Ltd Address...................................:Floor11,BuildingB2,Phase2,CreativeCity,XiandongRoad,Xili Community,XiliStreet,NanshanDistrict,Shenzhen,Guangdong, China Telephone...............................:/ Fax..........................................:/ Page4of33FCCID:2AQY4-ZW700ReportNo.:LCSA030323156EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000March22,2023InitialIssue--- Page5of33FCCID:2AQY4-ZW700ReportNo.:LCSA030323156EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION.........................................................................................6 1.1DescriptionofDevice(EUT).................................................................................................6 1.2.SupportEquipmentList.....................................................…
Text truncated - open the document above for the full version.
Page1of2FCCID:2AQY4-ZW700 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 Page2of2FCCID:2AQY4-ZW700 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 908.4 MHz - 916 MHz | 11.60 mW |
Wi-Fi Smart Lock
Equipment Class
DTS - Digital Transmission SystemSmart WiFi Lock With Fingerprint
Equipment Class
DTS - Digital Transmission SystemSmart WiFi Lock With Fingerprint
Equipment Class
DTS - Digital Transmission System
Smart Door Knob
Equipment Class
DTS - Digital Transmission SystemDIGITAL FINGERPRINT DOOR LOCK WITH DOORBELL
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter