LINKLIKE Free12 LINKLIKE Free12 Two Device Connection Explanation 1. Turn on the earphones - Enable the Bluetooth function on devices A and B - Connect on the device interface; (Quick connection is possible within 20 seconds) 2. Connect to device A - click the reset button 5 times to waiting for connection again and connect to device B. If two devices are already connected, you will need to disconnect one of them first. (Note: If you cannot reconnect immediately, close and open the bluetooth function again.) Connect device A Connect device B Click 5 times Reset Button L R L R Left ear function button Music Mode Call Mode Normal Mode (In non-music non-call mode) 1. Do not use corrosive cleaning agents to clean this product. 2. Do not use this product in high temperature or humid environments, and avoid heating, close proximity to a heat source, or placing it in fire to prevent explosions. 3. This product does not have any user-maintainable parts. Do not disassemble or modify it without authorization. 4. If the product is not used for a long time, please store the earphones in the charging case and ensure a dry storage environment. Additionally, charge the charging case at least once a month. 5. Do not charge the product in temperatures below zero, as it may damage the battery. 6. Do not use this product during thunderstorms, as it may cause abnormal headphone operation and increase the risk of electric shock. 7.Adjust the system volume to a moderate level when using this product for an extended period of time, as high volume levels may pose a risk to hearing loss. 8. Do not use this product in situations that require special attention, such as while in traffic or engaging in skilled work. 9. When using a charger for power supply, please purchase or use a charger that has obtained certification and meets the standard requirements. 10.To ensure the normal use of this product, please use a USB-C charging adapter that complies with national standards. 11. Please keep the product accessories and packaging components out of reach of children and pets to prevent accidents and choking hazards. This product contains a built-in lithium battery. Please note the following: 1. Please charge the battery promptly when the power is low. If not used for a long time, please turn on the product every three months until the battery is fully discharged, and then fully charge the battery to prevent battery damage. It is recommended to use and store the product in suitable environmental temperatures. 2. Do not dismantle, impact, squeeze, or throw into fire. If severe swelling occurs, please stop using it. Do not place it in high-temperature environments. If the battery life is significantly reduced, please stop using it and have it repaired by professionals. 3. Improper battery replacement may cause explosion risks. Only use the same type or equivalent type of battery and have it replaced by professionals. 4. The battery (battery pack or combination battery) should not be exposed to sunlight, fire, or similar overheating environments. 5. Products containing lithium batteries should be disposed of separately from household waste. If the product is discarded, the battery should be removed and the positive and negative ends should be insulated before being placed in designated recycling locations or handed over to environmental protection recycling departments. Do not dispose of it casually. 6. Battery dismantling steps: Disassemble the product and remove the PCB and battery components. Use a screwdriver to unscrew the screws one by one. Separate the battery from the circuit board and casing. Cut off the connection between the battery and the circuit board, and then remove the battery.(Special warning: Do not cut off all the connecting wires between the battery and the circuit board at the same time.) Important InstructionsBattery Warning Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. LINKLIKE Free12 Model: LNOW1 Linklike (Shenzhen) Technology Co., Ltd. ADD: RM1709, BLK C, Zhantao Technology BLDG, Minzhi Avenue, Minzhi ST, Longhua DIST, Shenzhen, China Linklike is a trademark registered in the USA and other countries. All rights reserved. Made in China E-mail: [email protected] LKPC01010A Press once: Charging case battery level Press for 3s: Factory reset Press five time: Enter/Exit waiting for connection Right ear function button L R L R Left ear function button Click Once: Play/pause music Click Twice: Previous song Long Press: Volume - Click Twice: Answer call Long press: Hang up/ Re…
Text truncated - open the document above for the full version.
Linklike (Shenzhen) Technology Co., Ltd. 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type Company name: Linklike (Shenzhen) Technology Co., Ltd. Address: RM 1709,BLK C,Zhantao Technology BLDG, Minzhi Avenue,Minzhi ST, Longhua DIST, Shenzhen, China Product Name: LINKLIKE Free12 FCC ID: 2AR3E-LNOW1 Model(s): LNOW1 2.911(d)(5)(i) Equipment Type We, [Linklike (Shenzhen) Technology Co., Ltd. ] (“the applicant”) certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: Earl Zhu Date: 2024-10-14 Title and Company name: Compliance Engineer NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
Linklike (Shenzhen) Technology Co., Ltd. 2.911 (d)(5)(ii) Applicant Attestation v1.2 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: Linklike (Shenzhen) Technology Co., Ltd. Address: RM 1709,BLK C,Zhantao Technology BLDG, Minzhi Avenue,Minzhi ST, Longhua DIST, Shenzhen, China Product Name: LINKLIKE Free12 FCC ID: 2AR3E-LNOW1 Model(s): LNOW1 2.911(d)(5)(ii) Applicant filing We, [Linklike (Shenzhen) Technology Co., Ltd. ] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 , established pursuant to § 1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Name: Earl Zhu Date: 2024-10-14 Title and Company name: Compliance Engineer NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
Linklike (Shenzhen) Technology Co., Ltd. 2.911 (d)(7)USA Agent v1.2 Section 2.911(d)(7) USA Agent for Service of Process Company name: Linklike (Shenzhen) Technology Co., Ltd. Address: RM 1709,BLK C,Zhantao Technology BLDG, Minzhi Avenue,Minzhi ST, Longhua DIST, Shenzhen, China Product Name: LINKLIKE Free12 FCC ID: 2AR3E-LNOW1 Model(s): LNOW1 2.911(d)(7) USA Designated Agent for Service of Process We, [Linklike (Shenzhen) Technology Co., Ltd. ] (“the applicant”) designate [THREE STONES MEDIA LLC] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We Acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We Acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Company name: THREE STONES MEDIA LLC Address: 1200 Broadway St. APT 329, Los Angeles, CA90015 FRN: 0033401761 Contact Name: Sijie Zhang Telephone No: +1 267 909 3692 Email: [email protected] Applicant Company name: Linklike (Shenzhen) Technology Co., Ltd. Address: RM 1709,BLK C,Zhantao Technology BLDG, Minzhi Avenue,Minzhi ST, Longhua DIST, Shenzhen, China FRN: 0028070993 FCC Grantee Code: 2AR3E Contact Name: Earl Zhu Telephone No: 8615019224926 Email: [email protected] Signature: Signature: Linklike (Shenzhen) Technology Co., Ltd. 2.911 (d)(7)USA Agent v1.2 Title: Title: Manager Date: 2024-10-14 Date: 2024-10-14 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process. Reference; Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threat s- to-the-communications-supply-chain-through-the
Linklike (Shenzhen) Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2024-10-14 Subject; Request for Long Term Confidentiality FCC ID: 2AR3E-LNOW1 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Earl Zhu Title: Compliance Engineer
Letter of Authorization Company: Linklike (Shenzhen) Technology Co., Ltd. Address: RM 1709,BLK C,Zhantao Technology BLDG, Minzhi Avenue,Minzhi ST, Longhua DIST, Shenzhen, China Product Name: LINKLIKE Free12 Model Number: LNOW1 FCC Identifier: 2AR3E-LNOW1 We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: Earl Zhu Date: 2024-10-14 Title: Compliance Engineer
Model:LNOW1 External Model:LNOW1 Model:LNOW1 Model:LNOW1
Label&Location
Model:LNOW1 Internal Model:LNOW1 Model:LNOW1
TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 1 of 7 BTFTestingLab(Shenzhen)Co.,Ltd. F101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,China RFExposureReport For Applicantname:Linklike(Shenzhen)TechnologyCo.,Ltd. Address: RM1709,BLKC,ZhantaoTechnologyBLDG,MinzhiAvenue,Minzhi ST,LonghuaDIST,Shenzhen,China EUTname:LINKLIKEFree12 Brandname:LINKLIKE Modelnumber:LNOW1 IssuedBy Companyname: BTFTestingLab(Shenzhen)Co.,Ltd. Address: F101,201and301,Building1,Block2,TantouIndustrialPark, TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, China Reportnumber: BTF240919R00103 Teststandards: 47CFRPart2SubpartJSection2.1093 FCCID:2AR3E-LNOW1 Testconclusion: Pass Dateofsamplereceipt: 2024-09-19 Testdate: 2024-09-19to2024-09-27 Dateofissue: 2024-09-28 Testby: Ssxx.guo/Tester Preparedby: Approvedby: AriaZhang/Project engineer Ryan.CJ/EMCmanager Note:Allthetestresultsinthisreportonlyrelatedtothetestingsamples.Whichcanbeduplicatedcompletelyforthelegalusewithapprovalofapplicant;it shallnotbereproducedexceptinfullwithoutthewrittenapprovalofBTFTestingLab(Shenzhen)Co.,Ltd.,Alltheobjectionsshouldberaisedwithinthirty daysfromthedateofissue.Tovalidatethereport,youcancontactus. TestReportNumber:BTF240919R00103 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 2 of 7 BTFTestingLab(Shenzhen)Co.,Ltd. F101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,China RevisionHistory VersionIssueDateRevisionsContent R_V0 2024-09-28 Original Note:Oncetherevisionhasbeenmade,thenpreviousversionsreportsareinvalid. TestReportNumber:BTF240919R00103 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 3 of 7 BTFTestingLab(Shenzhen)Co.,Ltd. F101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,China TableofContents 1.Introduction.............................................................................................................................................................................................4 1.1IdentificationofTestingLaboratory..................................................................................................................................4 1.2IdentificationoftheResponsibleTestingLocation......................................................................................................4 1.3LaboratoryCondition............................................................................................................................................................4 1.4Announcement........................................................................................................................................................................4 2.ProductInformation...............................................................................................................................................................................5 2.1ApplicationInformation........................................................................................................................................................5 2.2ManufacturerInformation.....................................................................................................................................................5 2.3FactoryInformation...............................................................................................................................................................5 2.4GeneralDescriptionofEquipmentunderTest(EUT)...................................................................................................5 3.TestRequirement..................................................................................................................................................................................6 3.1AssessmentResult................................................................................................................................................................6 TestReportNumber:BTF240919R00103 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 4 of 7 BTFTestingLab(Shenzhen)Co.,Ltd. F101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,China 1.Introduction 1.1IdentificationofTestingLaboratory CompanyName:BTFTestingLab(Shenzhen)Co.,Ltd. Address: F101,201and301,Building1,Block2,TantouIndustrialPark,Tantou Community,SonggangStreet,Bao'anDistrict,Shenzhen,China PhoneNumber:+86-0755-23146130 FaxNumber:+86-0755-23146130 1.2IdentificationoftheResponsibleTestingLocation TestLocation:BTFTestingLab(Shenzhen)Co.,Ltd. Address: F101,201and301,Building1,Block2,TantouIndustrialPark,Tantou Community,SonggangStreet,Bao'anDistrict,Shenzhen,China Description: Allmeasurementfacilitiesusedtocollectthemeasurementdataarelocated atF101,201and301,Building1,Block2,TantouIndustrialPark,Tantou Community,SonggangStreet,Bao'anDistrict,Shenzhen,China FCCRegistrationNumber:518915 DesignationNumber:CN1330 1.3LaboratoryCondition AmbientTemperature:20°Cto25°C AmbientRelativeHumidity:45%to55% AmbientPressure:100kPato102kPa 1.4Announcement (1)Thetestreportreferencetothereporttemplateversionv0. (2)Thetestreportisinvalidifnotmarkedwiththesignaturesofthepersonsresponsibleforpreparing, reviewingandapprovingthetestreport. (3)Thetestreportisinvalidifthereisanyevidenceand/orfalsification. (4)ThisdocumentmaynotbealteredorrevisedinanywayunlessdonesobyBTFandallrevisionsareduly notedintherevisionssection. (5)Contentofthetestreport,inpartorinfull,cannotbeusedforpublicityand/orpromotionalpurposeswithout priorwrittenapprovalfromthelaboratory. (6)Thelaboratoryisonlyresponsibleforthedatareleasedbythelaboratory,exceptforthepartprovidedbythe applicant. TestReportNumber:BTF240919R00103 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLabo…
Text truncated - open the document above for the full version.
BTF240919R00101 1.DutyCycle 1.1TestResult 1.1.1Ant1 Ant1 Mode TX Type Frequency (MHz) T_on (ms) Period (ms) DutyCycle (%) DutyCycle CorrectionFactor(dB) Max.DC Variation(%) 1MSISO 24022.2102.49988.440.530.13 24402.2102.50288.330.540.25 24802.2102.50288.330.540.25 2MSISO 24021.1502.49646.073.370.14 24401.1512.49946.063.370.26 24801.1542.50346.103.360.19 BTF240919R00101 1.2TestGraph 1.2.1Ant1 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV BTF240919R00101 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV BTF240919R00101 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV BTF240919R00101 2.Bandwidth 2.1TestResult 2.1.1OBW Mode TX Type Frequency (MHz) ANT 99%OccupiedBandwidth(MHz) Verdict ResultLimit 1MSISO 240211.016/Pass 244011.012/Pass 248011.014/Pass 2MSISO 240212.054/Pass 244012.046/Pass 248012.052/Pass 2.1.26dBBW Mode TX Type Frequency (MHz) ANT 6dBBandwidth(MHz) Verdict ResultLimit 1MSISO 240210.665>=0.5Pass 244010.664>=0.5Pass 248010.662>=0.5Pass 2MSISO 240211.141>=0.5Pass 244011.135>=0.5Pass 248011.130>=0.5Pass BTF240919R00101 2.2TestGraph 2.2.1OBW 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV BTF240919R00101 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV BTF240919R00101 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV BTF240919R00101 2.2.26dBBW 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV BTF240919R00101 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV BTF240919R00101 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV BTF240919R00101 3.MaximumConductedOutputPower 3.1TestResult 3.1.1Power Mode TX Type Frequency (MHz) MaximumPeakConductedOutputPower(dBm) Verdict ANT1Limit 1MSISO 2402-2.74<=30Pass 2440-2.15<=30Pass 2480-3.24<=30Pass 2MSISO 2402-3.93<=30Pass 2440-3.41<=30Pass 2480-2.98<=30Pass Note1:AntennaGain:Ant1:-0.98dBi; BTF240919R00101 3.2TestGraph 3.2.1Power 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV BTF240919R00101 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV BTF240919R00101 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV BTF240919R00101 4.MaximumPowerSpectralDensity 4.1TestResult 4.1.1PSD Mode TX Type Frequency (MHz) MaximumPSD(dBm/3kHz) Verdict ANT1Limit 1MSISO 2402-13.34<=8Pass 2440-13.34<=8Pass 2480-13.83<=8Pass 2MSISO 2402-15.16<=8Pass 2440-15.62<=8Pass 2480-14.36<=8Pass Note1:AntennaGain:Ant1:-0.98dBi; BTF240919R00101 4.2TestGraph 4.2.1PSD 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV BTF240919R00101 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV BTF240919R00101 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV BTF240919R00101 5.UnwantedEmissionsInNon-restrictedFrequencyBands 5.1TestResult 5.1.1Ref Mode TX Type Frequency (MHz) ANT LevelofReference (dBm) 1MSISO 24021-2.49 24401-1.93 24801-3.00 2MSISO 24021-3.77 24401-3.27 24801-2.88 Note1:RefertoFCCPart15.247(d)andANSIC63.10-2020,thechannelcontainsthemaximumPSDlevelwasusedto establishthereferencelevel. 5.1.2CSE Mode TX Type Frequency (MHz) ANT LevelofReference (dBm) Limit (dBm) Verdict 1MSISO 24021-1.93-21.93Pass 24401-1.93-21.93Pass 24801-1.93-21.93Pass 2MSISO 24021-2.88-22.88Pass 24401-2.88-22.88Pass 24801-2.88-22.88Pass Note1:RefertoFCCPart15.247(d)andANSIC63.10-2020,thechannelcontainsthemaximumPSDlevelwasusedto establishthereferencelevel. BTF240919R00101 5.2TestGraph 5.2.1Ref 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV BTF240919R00101 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV BTF240919R00101 2M_MCH_2440MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV BTF240919R00101 5.2.2CSE 1M_LCH_2402MHz_Ant1_NTNV 1M_LCH_2402MHz_Ant1_NTNV BTF240919R00101 1M_MCH_2440MHz_Ant1_NTNV 1M_HCH_2480MHz_Ant1_NTNV BTF240919R00101 1M_HCH_2480MHz_Ant1_NTNV 2M_LCH_2402MHz_Ant1_NTNV BTF240919R00101 2M_LCH_2402MHz_Ant1_NTNV 2M_MCH_2440MHz_Ant1_NTNV BTF240919R00101 2M_HCH_2480MHz_Ant1_NTNV 2M_HCH_2480MHz_Ant1_NTNV BTF240919R00101 6.Form731 6.1TestResult 6.1.1Form731 LowerFreq(MHz)HighFreq(MHz)MAXPower(W)MAXPower(dBm) 240224800.0006-2.15
TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 1 of 23 BTFTestingLab(Shenzhen)Co.,Ltd. F101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 RFTestReport For Applicantname:Linklike(Shenzhen)TechnologyCo.,Ltd. Address: RM1709,BLKC,ZhantaoTechnologyBLDG,MinzhiAvenue,Minzhi ST,LonghuaDIST,Shenzhen,China EUTname:LINKLIKEFree12 Brandname:LINKLIKE Modelnumber:LNOW1 IssuedBy Companyname: BTFTestingLab(Shenzhen)Co.,Ltd. Address: F101,201and301,Building1,Block2,TantouIndustrialPark, TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen, China Reportnumber: BTF240919R00101 Teststandards: FCCCFRTitle47Part15SubpartC(§15.247) FCCID:2AR3E-LNOW1 Testconclusion: Pass Dateofsamplereceipt: 2024-09-19 Testdate: 2024-09-19to2024-09-27 Dateofissue: 2024-09-28 Testby: Ssxx.guo/Tester Preparedby: Approvedby: AriaZhang/Project engineer Ryan.CJ/EMCmanager Note:Allthetestresultsinthisreportonlyrelatedtothetestingsamples.Whichcanbeduplicatedcompletelyforthelegalusewithapprovalofapplicant;it shallnotbereproducedexceptinfullwithoutthewrittenapprovalofBTFTestingLab(Shenzhen)Co.,Ltd.,Alltheobjectionsshouldberaisedwithinthirty daysfromthedateofissue.Tovalidatethereport,youcancontactus. ReportNumber:BTF240919R00101 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 2 of 23 BTFTestingLab(Shenzhen)Co.,Ltd. F101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 RevisionHistory VersionIssuedateRevisionscontent R_V02024-09-28Original Note: Oncetherevisionhasbeenmade,thenpreviousversionsreportsareinvalid. ReportNumber:BTF240919R00101 TotalorpartialreproductionofthisdocumentwithoutpermissionoftheLaboratoryisnotallowed.Page 3 of 23 BTFTestingLab(Shenzhen)Co.,Ltd. F101,201and301,Building1,Block2,TantouIndustrialPark,TantouCommunity,SonggangStreet,Bao'anDistrict,Shenzhen,China Email:[email protected]:+86-755-23146130http://www.btf-lab.comVersion:1/00 TableofContents 1Introduction...............................................................................................................................................................4 1.1LaboratoryLocation..........................................................................................................................................4 1.2LaboratoryFacility............................................................................................................................................4 1.3Announcement..................................................................................................................................................4 2ProductInformation..................................................................................................................................................5 2.1ApplicationInformation.....................................................................................................................................5 2.2ManufacturerInformation.................................................................................................................................5 2.3FactoryInformation...........................................................................................................................................5 2.4GeneralDescriptionofEquipmentunderTest(EUT)......................................................................................5 2.5TechnicalInformation.......................................................................................................................................5 3TestInformation........................................................................................................................................................6 3.1TestStandards.................................................................................................................................................6 3.2SummaryofTest..............................................................................................................................................6 3.3UncertaintyofTest............................................................................................................................................7 3.4Additionsto,deviations,orexclusionsfromthemethod..................................................................................7 3.5TestAuxiliaryEquipment..................................................................................................................................7 3.6TestEquipmentList..........................................................................................................................................7 4TestConfiguration....................................................................................................................................................9 4.1EnvironmentCondition.....................................................................................................................................9 4.2Testmode.........................................................................................................................................................9 4.3TestChannelofEUT........................................................................................................................................9 4.4Testprocedure................................................................................................................................................10 4.5TestSetupBlock.............................................................................................................................................11 5Technicalrequirementsspecification.....................................................................…
Text truncated - open the document above for the full version.
ConfidentialInformation Page 2 目录/Catalogue 序号 No. 项目 Item 页码 PageNo. 1射频性能测试报告3-7 2图纸或实物图片8/10 3尺寸测量报告9/11 4可靠性测试报告12 Radio Frequency Performance Test Report Drawings or pictures of actual objects Dimension Measurement Report Reliability test report ConfidentialInformation Page 3 1.Antennapicture ThereportmainlyprovidestheteststatusoftheelectricalpropertiesparametersofOW1.The OW1antennaisa2.4~2.5GHzBand.TheantennaPictureandassemblyareshownbelow.Antenna picture&assemblypicture 2.AntennaTestEquipmentIntroduction Testofantennainputcharacterist…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 600.00 µW |

LINKLIKE LY2
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterSports Earphones
Equipment Class
DTS - Digital Transmission System
LINKLIKE Halo
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Ture Wireless Earbuds
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter