Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 <2020-12-28> TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AR3EGENIE10 LINKLIKE Genie 10 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, (Signed) Name/Title: Earl Zhu / Compliance Engineer Company: Linklike(Shenzhen)Technology Co., Ltd Address: RM 1409, BLK.C Zhantao Technology BLDG.Minzhi Avenue, Minzhi ST. Longhua DiST, Shenzhen, China Phone: +86-15019224926 Fax: +86-15019224926 E-Mail: [email protected]
Linklike(Shenzhen)Technology Co., Ltd RM 1409, BLK.C Zhantao Technology BLDG.Minzhi Avenue, Minzhi ST. Longhua DiST, Shenzhen, China Date: December 28, 2020 FCC ID: 2AR3EGENIE10 Model Number: LINKLIKE Genie 10 To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Linklike(Shenzhen)Technology Co., Ltd hereby declare that our product (Ture Wireless Earbuds) Model Number: LINKLIKE Genie 10 will disable Bluetooth Lower Energy function (Bluetooth V5.0 LE&2LE) by software and only open Bluetooth Classics function (Bluetooth V5.0) although Bluetooth modular BT8852B support both Bluetooth Lower Energy (Bluetooth V5.0 LE&2LE) and Bluetooth Classics (Bluetooth V5.0) due to marketing purposes. End-user will only use Bluetooth Classics (Bluetooth V5.0) in USA market. Please contact me if you have any question. Sincerely, (Signed) Name/Title: Earl Zhu / Compliance Engineer Company: Linklike(Shenzhen)Technology Co., Ltd Address: RM 1409, BLK.C Zhantao Technology BLDG.Minzhi Avenue, Minzhi ST. Longhua DiST, Shenzhen, China Phone: +86-15019224926 Fax: +86-15019224926 E-Mail: [email protected]
Linklike(Shenzhen)Technology Co., Ltd RM 1409, BLK.C Zhantao Technology BLDG.Minzhi Avenue, Minzhi ST. Longhua DiST, Shenzhen, China Labeling Declaration Letter Date: December 28, 2020 FCC ID: 2AR3EGENIE10 Model Number: LINKLIKE Genie 10 Following the KDB 784748 D01 General labeling and Notification, the information related to Labeling implementation for the Ture Wireless Earbuds, FCC ID: 2AR3EGENIE10 Information On Product On Product Packaging In Online User Guide In Printed User Guide FCC ID Number Yes Yes No No 15.19 Statement “This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation” No Yes No Yes Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment No No No Yes Product Packaging Label is shown below: FCC ID: 2AR3EGENIE10 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, The product is packaged individually. Linklike(Shenzhen)Technology Co., Ltd RM 1409, BLK.C Zhantao Technology BLDG.Minzhi Avenue, Minzhi ST. Longhua DiST, Shenzhen, China Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name/Title: Earl Zhu / Compliance Engineer Company: Linklike(Shenzhen)Technology Co., Ltd Address: RM 1409, BLK.C Zhantao Technology BLDG.Minzhi Avenue, Minzhi ST. Longhua DiST, Shenzhen, China Phone: +86-15019224926 Fax: +86-15019224926 E-Mail: [email protected]
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 LABEL AND LOCATION Size: L1.0cm*W0.5cm Label Location FCC ID: 2AR3EGENIE10
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 1. NTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Fig. 3 Fig. 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Fig. 5 Fig. 6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Fig. 7 Fig. 8 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Fig. 9 BT Antenna
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 3 FCC RF Exposure Evaluation 1. Product Information FCC ID: 2AR3EGENIE10 Product name Ture Wireless Earbuds Model number LINKLIKE Genie 10 Power supply Earbuds: DC 3.7V by battery(45mAh) Box: DC 3.7V by battery(400mAh) Recharged by DC 5V, 400mA Modulation Type GFSK, π/4-DQPSK, 8-DPSK for V5.0 (BT Classics) Channel Number 79 channels for V5.0 (BT Classics) Channel Spacing 1MHz for V5.0 (BT Classics) Antenna Type Internal Antenna Antenna Gain 2.0 dBi (maximum) Hardware version TW100-8856B V1.1 Software version S35X_S193_8852_TW100_LINKLIKEGenie10_2019_0918_1657 Bluetooth Operation frequency 2402MHz-2480MHz Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Portable 2. Evaluation Method According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 3 modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b) The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices 4. Conducted Power Results Mode Channel Frequency(MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 3.652 39 2441 4.320 78 2480 5.010 π/4DQPSK 0 2402 4.708 39 2441 5.392 78 2480 6.082 8-DPSK 0 2402 4.952 39 2441 5.647 78 2480 6.327 5. Manufacturing Tolerance GFSK (Peak) Channel Channel 0 Channel 39 Channel 78 Target (dBm) 4.0 4.0 5.0 Tolerance ±(dB) 1.0 1.0 1.0 π/4-DQPSK (Peak) Channel Channel 0 Channel 39 Channel 78 Target (dBm) 5.0 5.0 6.0 Tolerance ±(dB) 1.0 1.0 1.0 8-DPSK (Peak) Channel Channel 0 Channel 19 Channel 39 Target (dBm) 5.0 5.0 6.0 Tolerance ±(dB) 1.0 1.0 1.0 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 3 6. Evaluation Results 6.1 Standalone Evaluation Band/Mode f…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 1 of 47 Appendix A RF Test Data for BT V5.0 (BDR/EDR) (Conducted Measurement) Product Name: Ture Wireless Earbuds Trade Mark: Linklike Test Model: LINKLIKE Genie 10 Environmental Conditions Temperature: 23.7 C Relative Humidity: 56% ATM Pressure: 100.0 kPa Test Engineer: CHUANG WANG Supervised by: JAYDEN ZHUO A.1 Maxmum Conducted Peak Output Power Mode Channel. Maximum Peak Output Power [dBm] Limit [dBm] Verdict GFSK LCH 3.652 30 PASS MCH 4.320 30 PASS HCH 5.010 30 PASS π/4DQPSK LCH 4.708 21 PASS MCH 5.392 21 PASS HCH 6.082 21 PASS 8DPSK LCH 4.952 21 PASS MCH 5.647 21 PASS HCH 6.327 21 PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 2 of 47 Test Graphs GFSK/LCH GFSK/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 3 of 47 GFSK/HCH π/4DQPSK/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 4 of 47 π/4DQPSK/MCH π/4DQPSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 5 of 47 8DPSK/LCH 8DPSK/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 6 of 47 8DPSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 7 of 47 A.2 20dB Bandwidth Mode Channel. 20dB Bandwidth [MHz] Limit [MHz] Verdict GFSK LCH 1.039 Not Specified PASS MCH 1.026 Not Specified PASS HCH 1.032 Not Specified PASS π/4DQPSK LCH 1.394 Not Specified PASS MCH 1.397 Not Specified PASS HCH 1.399 Not Specified PASS 8DPSK LCH 1.376 Not Specified PASS MCH 1.380 Not Specified PASS HCH 1.379 Not Specified PASS Test Graphs GFSK/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 8 of 47 GFSK/MCH GFSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 9 of 47 π/4DQPSK/LCH π/4DQPSK/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 10 of 47 π/4DQPSK/HCH 8DPSK/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 11 of 47 8DPSK/MCH 8DPSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 12 of 47 A.3 Carrier Frequency Separation Mode Channel. Carrier Frequency Separation [MHz] Limit [MHz] Verdict GFSK LCH 0.992 0.693 PASS MCH 1.022 0.693 PASS HCH 1.074 0.693 PASS π/4DQPSK LCH 0.968 0.933 PASS MCH 0.984 0.933 PASS HCH 1.010 0.933 PASS 8DPSK LCH 1.124 0.920 PASS MCH 0.982 0.920 PASS HCH 1.128 0.920 PASS Test Graphs GFSK/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 13 of 47 GFSK/MCH GFSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 14 of 47 π/4DQPSK/LCH π/4DQPSK/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 15 of 47 π/4DQPSK/HCH 8DPSK/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 16 of 47 8DPSK/MCH 8DPSK/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 17 of 47 A.4 Hopping Channel Number Mode Channel. Number of Hopping Channel [N] Limit [N] Verdict GFSK Hop 79 >=15 PASS π/4DQPSK Hop 79 >=15 PASS 8DPSK Hop 79 >=15 PASS Test Graphs GFSK/Hop π/4DQPSK/Hop SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 18 of 47 8DPSK/Hop SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 19 of 47 A.5 Dwell Time Mode Packet Channel Burst Width [ms/hop/ch] Total Hops[hop*ch] Dwell Time[s] Limit [s] Verdict GFSK DH5 LCH 2.92 106.7 0.312 0.4 PASS DH5 MCH 2.93 106.7 0.313 0.4 PASS DH5 HCH 2.93 106.7 0.313 0.4 PASS π/4DQPSK 2DH5 LCH 2.92 106.7 0.313 0.4 PASS 2DH5 MCH 2.93 106.7 0.313 0.4 PASS 2DH5 HCH 2.93 106.7 0.313 0.4 PASS 8DPSK 3DH5 LCH 2.92 106.7 0.31 0.4 PASS 3DH5 MCH 2.93 106.7 0.313 0.4 PASS 3DH5 HCH 2.93 106.7 0.313 0.4 PASS Test Graphs GFSK_DH5/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 20 of 47 GFSK_DH5/MCH GFSK_DH5/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 21 of 47 π/4DQPSK _2DH5/LCH π/4DQPSK _2DH5/MCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 22 of 47 π/4DQPSK _2DH5/HCH 8DPSK _3DH5/LCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 23 of 47 8DPSK _3DH5/MCH 8DPSK _3DH5/HCH SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 24 of 47 A.6 RF Conducted Spurious Emissions Mode Channel Pref [dBm] Max. Level [dBm] Limit [dBm] Verdict GFSK LCH 2.871 -37.951 -17.129 PASS MCH 3.571 -37.969 -16.429 PASS HCH 4.176 -37.542 -15.824 PASS π/4DQPSK LCH 1.641 -37.283 -18.359 PASS MCH 2.387 -38.495 -17.613 PASS HCH 3.089 -38.772 -16.911 PASS 8DPSK LCH 1.713 -37.717 -18.287 PASS MCH 2.47 -38.216 -17.530 PASS HCH 3.233 -37.399 -16.767 PASS SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 25 of 47 GFSK_LCH_Graphs Pref Puw SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 26 of 47 GFSK_MCH_Graphs Pref Puw SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 27 of 47 GFSK_HCH_Graphs Pref Puw SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE Page 28 of 47 π/4DQPSK_LCH_Graphs Pref Puw SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 37 FCC TEST REPORT FOR Linklike(Shenzhen)Technology Co., Ltd Ture Wireless Earbuds Test Model: LINKLIKE Genie 10 Additional Model: / Prepared for : Linklike(Shenzhen)Technology Co., Ltd Address : RM 1409, BLK.C Zhantao Technology BLDG.Minzhi Avenue, Minzhi ST. Longhua DiST, Shenzhen, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : September 10, 2019 Number of tested samples : 1 Serial number : Prototype Date of Test : September 10, 2019 ~ November 30, 2020 Date of Report : November 30, 2020 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 37 FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................ : LCS190910048AE Date of Issue .................................. : November 30, 2020 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : Linklike(Shenzhen)Technology Co., Ltd Address .......................................... : RM 1409, BLK.C Zhantao Technology BLDG.Minzhi Avenue, Minzhi ST. Longhua DiST, Shenzhen, China Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No. .................... : LCSEMC-1.0 TRF Originator ............................... : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................... : Dated 2019-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. ................. : Ture Wireless Earbuds Trade Mark ..................................... : Linklike Test Model...................................... : LINKLIKE Genie 10 Ratings ........................................... : Earbuds: DC 3.7V by battery(45mAh) Box: DC 3.7V by battery(400mAh) Recharged by DC 5V, 400mA Result ........................................... : Positive Compiled by: Supervised by: Approved by: Marry Chen /Administrators Calvin Weng/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 37 FCC -- TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS190910048AE November 30, 2020 Date of issue Test Model........................... : LINKLIKE Genie 10 EUT......................................... : Ture Wireless Earbuds Applicant............................... : Linklike(Shenzhen)Technology Co., Ltd Address.................................. : RM 1409, BLK.C Zhantao Technology BLDG.Minzhi Avenue, Minzhi ST. Longhua DiST, Shenzhen, China Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Linklike(Shenzhen)Technology Co., Ltd Address................................... : RM 1409, BLK.C Zhantao Technology BLDG.Minzhi Avenue, Minzhi ST. Longhua DiST, Shenzhen, China Telephone............................... : / Fax.......................................... : / Factory................................... : Linklike(Shenzhen)Technology Co., Ltd Address................................... : RM 1409, BLK.C Zhantao Technology BLDG.Minzhi Avenue, Minzhi ST. Longhua DiST, Shenzhen, China Telephone............................... : / Fax.......................................... : / SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 4 of 37 Revision History Revision Issue Date Revisions Revised By 000 November 30, 2020 Initial Issue Gavin Liang SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 Report No.: LCS190910048AE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 5 of 37 TABLE OF CONTENTS Description Page 1. GENERAL INFORMATION ................................................................................................. 6 1.1 Description of Device (EUT) ....................................................................................................... 6 1.2 Support equipment List ...........................................................................................................…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 _______________________________________________________________________________________________ 1. TEST SETUP PHOTOGRAPHS 1.1. Photo of Radiated Emissions Measurement Fig. 1 Fig. 2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AR3EGENIE10 _______________________________________________________________________________________________ 1.2. Photo of Conducted Emissions Measurement Fig. 3
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 4.29 mW |

LINKLIKE Free12
Equipment Class
DTS - Digital Transmission System
LINKLIKE LY2
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterSports Earphones
Equipment Class
DTS - Digital Transmission System
LINKLIKE Halo
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter