User Manual 用户手册 WiTalk BASE Intercom System Master Console 通话系统主站控制台 1 Product Prole 1.1 System Overview WiTalk BASE is a full-duplex wireless intercom system designed for professional collaboration scenarios such as lm and television production, live events, and on-site coordination. The system supports simultaneous talk and listen for multiple users without push-to-talk activation, meeting the real-time collaborative communication needs of teams in complex on-site environments. 1.2 System Capabilities • A single WiTalk BASE station can connect up to 16 terminal devices, and larger-scale deployments can be achieved through multi-base station cascading. • The system supports up to 8 independent talk groups, meeting the parallel communication needs of multiple groups such as the Director Group, Camera Group, Lighting Group, and Audio Group. • The communication range between the base station and headsets can reach up to 500 meters under unobstructed, line-of-sight conditions. Actual communication range may vary depending on on-site obstructions, installation height, electromagnetic environment, and usage conditions. • WiTalk BASE stations support wired cascading via LAN, allowing the system to scale up to 4 base stations with a maximum total capacity of 64 terminal devices. • In multi-base station coverage scenarios, connected terminals can automatically roam and switch between di erent base station coverage areas. 1.3 Audio Performance • Supports wideband voice communication with a 16 kHz audio sampling rate, frequency response range of 100 Hz–7 kHz, signal-to-noise ratio >55 dB, and distortion rate <1%. • Employs ENC multi-microphone array and noise reduction algorithms to suppress background interference in complex noise environments, thereby improving speech intelligibility and communication e ciency. • Adopts a 1.9 GHz DECT wireless transmission solution with strong anti-interference capability. Speci c available frequency bands, certication requirements, and sales versions are subject to target market regulations and actual shipping versions. 1.4 Interfaces and Expansion • The base station is equipped with LAN, 4-Wire, UAC, 3.5 mm, and other interfaces for audio connectivity and signal interaction with mixing consoles, two-way radios, computers, and other devices. • Supports DHCP and static IP network con guration for convenient Web management, system con guration, and maintenance across dierent LAN environments. • Supports audio interconnection with certain third-party wired intercom or audio systems via the 4W interface. Compatibility depends on the remote device's interface de nition, pin-out, and level settings. 1.5 Power Supply and Management • Supports V-Mount / G-Mount battery and DC adapter power supply to accommodate di erent on-site deployment requirements. • Supports con guration and management via the base station's local interface, Web interface, and App. • The base station supports local and online rmware upgrades; headset rmware update methods depend on the speci c model and current system conguration. Please refer to the corresponding chapter for detailed instructions. 2 Packing List 2.1 Kit Description WiTalk BASE is available in multiple kit con gurations, and the package contents may vary depending on the model. Please refer to the actual purchased version and the packing list card included in the package. 2.2 Package Contents • WiTalk BASE Station • Single-Ear Headset (con guration varies by kit version) • Dual-Ear Headset (con guration varies by kit version) • Helmet Headset (con guration varies by kit version) • Headset External Battery • 10-Slot Charging Case • Over-Ear Cushions • On-Ear Cushions • Single-Ear Head Pad • Microphone Windscreen • USB Type-A to Type-C Cable • Base Station Antenna • User Manual • Warranty Card 3 Base Station Structure and Interface Description 3.1 Base Station Appearance and Component Names The WiTalk BASE station consists of the following main components: Bluetooth Indicator Light IP Status Indicator Light Display Function Button Area Handle Antenna Connector and Antenna Reserved Expansion Port (not for user operation in the current version) RJ45 LAN 1 Port RJ45 LAN 2 Port 3/8" Mounting Screw Hole 5/8" Mounting Interface USB-A Port USB-C Port DC Power Port 3.5 mm Audio Port RJ45 4W Audio Port Locking Knob V-Mount / G-Mount Battery Plate Mounting Position 3.2 RJ45 LAN 1 / RJ45 LAN 2 Interface Description Pin-out The RJ45 LAN 1 / RJ45 LAN 2 ports are used for LAN cascading and system synchronization between WiTalk BASE stations. These ports are primarily used for audio, group, and system management data transmission in multi-base station expansion scenarios. Standard Pin-out PIN 1 Transceive Data+ PIN 2 Transceive Data- PIN 3 Receive Data+ PIN 4 CLK 100Hz+ PIN 5 CLK 100Hz- PIN 6 Receive Data- PIN 7 CLK GND PIN 8 CLK GND Usage Instructions These ports are only intended for system interconnection between WiTalk BASE stations. It is not recommended to use these ports as general network switch ports, PoE ports, or other general-purpose RJ45 ports. When cascading base stations, it is recommended to use CAT5e or CAT6 shielded cables to reduce the impact of external electromagnetic interference on system stability. It is recommended that the length of a single cable segment does not exceed 100 meters. Precautions LAN cascading is a digital signal interconnection and only supports communication between WiTalk BASE stations. Do not connect to routers or other third-part y devices. For multi-base station systems, please refer to Section 4.5 for network role con guration. 3.3 RJ45 4W Audio Interface Description The RJ45 4W audio port is used for 4W audio interconnection between WiTalk BASE and similar systems or certain third-party wired intercom/ audio systems. The original documentation clearly states that this interface supports both standard and crossover pin congurations and is used for internal WiTalk system connections or interfacing wi…
Text truncated - open the document above for the full version.
Shenzhen Jiayz photo industrial ., Ltd ADD: A16 Building, Intelligent Terminal Industrial Park of Silicon Valley Power, Guanlan, Longhua District, Shenzhen, China Tel: +86-0755-28435911 Email: [email protected] Attestation Letter Date: 2026-04-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir/Madam, Our product Intercom System Master Console, model: WiTalk BASE, WiTalk9 BASE, WiTalk BASE-V, WiTalk BASE-G, WiTalk BASE-G16, WiTalk BASE-V16, FCC ID: 2ARN3-41601BASE, for marketing purpose, this product only supports 2.4G WiFi: 2412-2462MHz(802.11b/g/n20/n40 mode); BLE 1M/2M: 2402-2480MHz; FP: 1920-1930 MHz(GFSK). This product has unused antennas. The antenna is as follows: The other functions and bands w ere disabled to use by manufacture in the software, the end user has no capability to acti vate it. Signature: Michael Zhao Manager
Shenzhen Jiayz photo industrial ., Ltd ADD: A16 Building, Intelligent Terminal Industrial Park of Silicon Valley Power, Guanlan, Longhua District, Shenzhen, China Tel: +86-0755-28435911 Email: [email protected] CFR 47 §2.911(d)(5)(i) Attestation Letter Attestation Letter Date: 2026-04-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID: 2ARN3-41601BASE Shenzhen Jiayz photo industrial ., Ltd certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely Yours, Signature: Michael Zhao Manager
Shenzhen Jiayz photo industrial ., Ltd ADD: A16 Building, Intelligent Terminal Industrial Park of Silicon Valley Power, Guanlan, Longhua District, Shenzhen, China Tel: +86-0755-28435911 Email: [email protected] CFR 47 §2.911 (d)(5)(ii) Attestation Letter Attestation Letter Date: 2026-04-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID: 2ARN3-41601BASE Shenzhen Jiayz photo industrial ., Ltd certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely Yours, Signature: Michael Zhao Manager
U.S. AGENT LETTER OF ATTESTATION Date: 2026-03-18 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2ARN3-41601BASE Shenzhen Jiayz photo industrial ., Ltd certifies that, as of the date of the filing of the application, Mamiya America Corporation is our designated U.S. agent for service of process for the above referenced FCC ID. Shenzhen Jiayz photo industrial ., Ltd accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Mamiya America Corporation accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Mamiya America Corporation Address: 75 Virginia Rd White Plains, NY 10063 FRN: 0033742214 Tel.: +1-(914) 345-5436 Email: [email protected] Signed by (printed name): Joseph Nassar Signature: Applicant: Shenzhen Jiayz photo industrial ., Ltd Address: A16 Building, Intelligent Terminal Industrial Park of Silicon Valley Power, Guanlan, Longhua District, Shenzhen, China FRN: 0027973098 Tel: +86-0755-28435911 Email: [email protected] Signed by (printed name): Michael Zhao Signature:
Shenzhen Jiayz photo industrial ., Ltd ADD: A16 Building, Intelligent Terminal Industrial Park of Silicon Valley Power, Guanlan, Longhua District, Shenzhen, China Tel: +86-0755-28435911 Email: [email protected] QA-FR-170-B 7/29/2014 FCC Authorization Date: 2026-04-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We Shenzhen Jiayz photo industrial ., Ltd, the undersigned, hereby authorizes Bay Area Compliance Laboratories Corp. (Shenzhen) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. (Shenzhen) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Michael Zhao Manager
Shenzhen Jiayz photo industrial ., Ltd ADD: A16 Building, Intelligent Terminal Industrial Park of Silicon Valley Power, Guanlan, Longhua District, Shenzhen, China Tel: +86-0755-28435911 Email: [email protected] FCC Confidential Authorization Date: 2026-04-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2ARN3-41601BASE In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Shenzhen Jiayz photo industrial ., Ltd hereby requests long-term confidential treatment of information accompanying this application as outlined below: • Block Diagram • Schematics • Operation Description • Part list The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Michael Zhao Manager
Shenzhen Jiayz photo industrial ., Ltd ADD: A16 Building, Intelligent Terminal Industrial Park of Silicon Valley Power, Guanlan, Longhua District, Shenzhen, China Tel: +86-0755-28435911 Email: [email protected] Product Similarity Declaration Date: 2026-04-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir or Madam, We Shenzhen Jiayz photo industrial ., Ltd hereby declare that we have a product named Intercom System Master Console (Model number: WiTalk BASE, FCC ID: 2ARN3-41601BASE) was tested by Bay Area Compliance Laboratories Corp. (Shenzhen). Meanwhile, for our marketing purpose, we would like to list a series models (WiTalk9 BASE,WiTalk BASE-V,WiTalk BASE-G,WiTalk BASE-G16,WiTalk BASE- V16) on reports and certificate. All of the models are electrically identical, but the difference among them is model name and sales channels. We confirm that all information above is true, and we’ll be responsible for all the consequences. Please contact with me if you have any question. Sincerely Yours, Signature: Michael Zhao Manager
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-EXP Page 1 of 6 EUT EXTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-EXP Page 2 of 6 Module1 ANT 1 ANT 2 ANT 1 ANT 2 Module2 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-EXP Page 3 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-EXP Page 4 of 6 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-EXP Page 5 of 6 DECT ANT Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-EXP Page 6 of 6
Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2601P26501E-RF FCC ID LABEL AND LOCATION Model: WiTalk BASE FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925) Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2601P26501E-RF Model: WiTalk9 BASE FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925) Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2601P26501E-RF Model: WiTalk BASE-V FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925) Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2601P26501E-RF Model: WiTalk BASE-G FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925) Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2601P26501E-RF Model: WiTalk BASE-G16 FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925) Bay Area Compliance Laboratories Corp. (Shenzhen) Project No.: 2601P26501E-RF Model: WiTalk BASE-V16 FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 1 of 17 EUT INTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 2 of 17 WIFI ANT Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 3 of 17 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 4 of 17 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 5 of 17 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 6 of 17 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 7 of 17 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 8 of 17 DECT Module 1 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 9 of 17 No use Ant DECT Module 2 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 10 of 17 No use Ant Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 11 of 17 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 12 of 17 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 13 of 17 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 14 of 17 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 15 of 17 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 16 of 17 Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-INP Page 17 of 17 BLE ANT
Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-00A TR-EM-RF004 Page 126 of 129 Version 4.1 RF EXPOSURE EVALUATION MPE-Based Exemption Applicable Standard According to subpart 15.247 (i) and subpart 2.1091 systems operating under the provisions of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in excess of the communication guidelines. According to KDB 447498 D04 Interim General RF Exposure Guidance MPE-Based Exemption: General frequency and separation-distance dependent MPE-based effective radiated power(ERP) thresholds are in Table B.1 [Table 1 of § 1.1307(b)(3)(i)(C)] to support an exemption from further evaluation from 300 kHz through 100 GHz. R is the minimum separation distance in meters f = frequency in MHz For multiple RF sources: Multiple RF sources are exempt if: in the case of fixed RF sources operating in the same time-averaging period, or of multiple mobile or portable RF sources within a device operating in the same time averaging period, if the sum of the fractional contributions to the applicable thresholds is less than or equal to 1 as indicated in the following equation: Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-00A TR-EM-RF004 Page 127 of 129 Version 4.1 Result Antenna Gain # ERP Mode Frequency (MHz) Tune up conducted power # (dBm) (dBi)(dBd)(dBm)(mW) Evaluation Distance (cm) ERP Limit (mW) BLE2402-2480-4-0.21-2.36-6.360.2320768 2.4G WIFI2412-2462243.56 1.4125.41347.5420768 DECT1921.536-1928.448194.472.3221.32135.5220768 Note 1: The tune-up power and antenna gain was declared by the applicant. Note 2: 0dBd=2.15dBi. Note 3: The DECT function can transmit at the same time with the Bluetooth and Wi-Fi function. Simultaneous transmitting consideration (worst case): The ratio= ERP BLE /limit + ERP 2.4 WIFI /limit + ERP DECT /limit = 0.23/768+347.54/768+135.52/768=0.629<1.0 To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm from nearby persons. Result: Compliant
Antenna Report Manufacturer:Shenzhen Jiayz photo industrial ., Ltd Address: A16 Building, Intelligent Terminal Industrial Park of Silicon Valley Power, Guanlan,Longhua District, Shenzhen, China Project:WiTalk BASE Antenna Information: DECT Antenna1/2/3/4:Dipole antenna, peak gain 4.47dBi WIFI Antenna:FPC PIFA antenna, peak gain 3.56dBi BLE Antenna:Chip antenna, peak gain -0.21dBi DECT Antenna Radiation Pattern Test Data XZ YZ XY 1880MHz 1930MHz Antenna - S Parameter Test Data Antenna Photo Antenna Dimension Unit: mm WIFI Antenna Radiation Pattern Test Data XZ YZ XY 2400MHz 2450MHz 2500MHz Antenna - S Parameter Test Data Antenna Photo Antenna Dimension Unit: mm BLE Antenna Radiation Pattern Test Data Frequency Efficiency(%) Gain(dBi) 2402MHz 25.04 -1.19 2441MHz 38.1 -0.21 2484MHz 20.1 -3.35 Antenna - S Parameter Test Data Antenna Photo Antenna Dimension Unit: mm
Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF004 Page 1 of 129 Version 4.1 TEST REPORT Applicant Name:Shenzhen Jiayz photo industrial ., Ltd Address:A16 Building,Intelligent Terminal Industrial Park of Silicon Valley Power, Guanlan, Longhua District, Shenzhen, China Report Number:2601P26501E-RF-00A FCC ID:2ARN3-41601BASE Test Standard (s) FCC PART 15.247 Sample Description Product Type:Intercom System Master Console Model No.:WiTalk BASE Multiple Model(s) No.:WiTalk9 BASE, WiTalk BASE-V, WiTalk BASE-G, WiTalk BASE-G16, WiTalk BASE-V16 Trade Mark:Saramonic Date Received:2026-01-19 Issue Date:2026-04-15 Test Result:Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By:Approved By: Ekko WuNancy Wang RF EngineerRF Supervisor Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-00A TR-EM-RF004 Page 2 of 129 Version 4.1 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ..........................................................................................................................3 GENERAL INFORMATION ........................................................................................................................................4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)......................................................................................4 OBJECTIVE ....................................................................................................................................................................4 TEST METHODOLOGY....................................................................................................................................................4 MEASUREMENT UNCERTAINTY .....................................................................................................................................5 TEST FACILITY ..............................................................................................................................................................5 SYSTEM TEST CONFIGURATION ...........................................................................................................................6 SUMMARY OF TEST RESULTS ..............................................................................................................................10 TEST EQUIPMENT LIST ..........................................................................................................................................11 REQUIREMENTS AND TEST PROCEDURES ......................................................................................................13 AC LINE CONDUCTED EMISSIONS...............................................................................................................................13 SPURIOUS EMISSIONS ..................................................................................................................................................15 6 DB EMISSION BANDWIDTH & 99% OCCUPIED BANDWIDTH ....................................................................................18 MAXIMUM CONDUCTED OUTPUT POWER ...................................................................................................................20 100 KHZ BANDWIDTH OF FREQUENCY BAND EDGE....................................................................................................21 CONDUCTED SPURIOUS EMISSION...............................................................................................................................22 POWER SPECTRAL DENSITY ........................................................................................................................................23 DUTY CYCLE ...............................................................................................................................................................26 ANTENNA REQUIREMENT .....................................................................................................................................27 TEST DATA AND RESULTS .....................................................................................................................................28 AC LINE CONDUCTED EMISSIONS...............................................................................................................................28 SPURIOUS EMISSIONS ..................................................................................................................................................33 6DB EMISSION BANDWIDTH......................................................................................................................................103 99% OCCUPIED BANDWIDTH ....................................................................................................................................107 MAXIMUM CONDUCTED OUTPUT POWER ............................................................…
Text truncated - open the document above for the full version.
Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF003 Page 1 of 91 Version 4.1 TEST REPORT Applicant Name:Shenzhen Jiayz photo industrial ., Ltd Address:A16 Building,Intelligent Terminal Industrial Park of Silicon Valley Power, Guanlan, Longhua District, Shenzhen, China Report Number:2601P26501E-RF-00B FCC ID:2ARN3-41601BASE Test Standard (s) FCC PART 15.247 Sample Description Product Type:Intercom System Master Console Model No.:WiTalk BASE Multiple Model(s) No.:WiTalk9 BASE, WiTalk BASE-V, WiTalk BASE-G, WiTalk BASE-G16, WiTalk BASE-V16 Trade Mark:Saramonic Date Received:2026-01-19 Issue Date:2026-04-15 Test Result:Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By:Approved By: Ekko WuNancy Wang RF EngineerRF Supervisor Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P26501E-RF-00B TR-EM-RF003 Page 2 of 91 Version 4.1 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ..........................................................................................................................3 GENERAL INFORMATION ........................................................................................................................................4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)......................................................................................4 OBJECTIVE ....................................................................................................................................................................4 TEST METHODOLOGY....................................................................................................................................................4 MEASUREMENT UNCERTAINTY .....................................................................................................................................5 TEST FACILITY ..............................................................................................................................................................5 SYSTEM TEST CONFIGURATION ...........................................................................................................................6 SUMMARY OF TEST RESULTS ......................................................................................…
Text truncated - open the document above for the full version.
75 Virginia Rd · White Plains, New York, 10063 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 201.00 mW |
| 2 | 15C | 2.40 GHz - 2.48 GHz | 400.00 µW |

Wireless Microphone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Wireless Microphone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Wireless Microphone
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterFull-duplex Wireless Intercom Headset System
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterFull-duplex Wireless Intercom Headset System
Equipment Class
PUE - Part 15 Unlicensed PCS portable Tx held to ear