
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SmartNightLampAlarm ClockManual Pleasereadthisinstructioncarefully beforeusingtheproductandkeepitsafe Output input Back view Product character Product appearanc PhotosensitiveholePressbutton Wi-Fiindicator Topview Excellentdesignandqualityofproducts 4.2inchlargesizewhiteLEDtimedisplay,brightnesscanbeautomatically adjustedaccordingtotheenvironmentbrightness,orcancompletelyturnoff theuniquedesignofbilateralindirectamberlighttothelightsensitive, canadjustthebrightnessbetween1-10levels,provideyouwithsoftandwarm lighting Twosetsofseparatealarmclocks,equippedwithsixkindsofnaturalsound wake-up,andthealarmclockcanbeadjustedaccordingtotheworkingdayand restdaytorepeatthecycleofsoftlightsandprofessionalwhitenoisesleep, theendofsleepcanautomaticallyturnoffthesoundandlights Timeformatsupports12/24H,12H,screen TimeDisplay andIcon Ligh ts Map Ligh ts Post perspect display AM/PMnetwork time,timezoneand daylightsaving time Voiceand APP controlalarmclocks,sleepersand lights FCC Statment NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Warning Statements: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment shall be installed and operated with minimum distance 20cm between the radiator & body. Operation al Product parameter ModelSNA006-S Size200×85×97.6mm Weight Aboutg405 ColorBlack MaterialABS+PC、silicagel,metal Control mode keystrokecontrol,APPcontrol,voicecontrol (linkthirdpartysmartaudio) InputMicroUSBadapter5V2A OutputUSBAoutput5V1A Power10W(MAX) Speaker Ω3W4 Packing List Smartnightlightalarmclock,manual,adapter (optional),chargingline(optional) Product certific ation Displayicon TimeDisplayicon Networktime,supporttimezoneanddaylightsavingtime;timeformat support12/24Hsystem,12Hsystem,screendisplayAM/PM.Bootdefault timeformatis12Hsystem.(Canlongpressthesettingkeytosetthe commontimesystem,butalsosupportAPPswitchingtimesystem) Indicatorlight ①/②alarmclock1/2indicator Checkthealarmclocktime, theindicatorlightswhen flashing Turnonthealarm clock,the indicatorlights alwaysturnoffthe alarmclock,the indicatorlights flickerduringthe sound Stopthenoise(duringthe noise),andtheindicator lightsflickerduringthenap Whenthealarmclockis set,theindicator lightsflicker 3Sleepy/LightIndicator Turnonsleepiness(during noise),indicatorlights flickeroffsleepiness, indicatorlightsgoout Keyfunctionexplanation 4.Settingindicatorlight Duringsetting,the indicatorlights flickeroutandthe indicatorlightsgo out 5sleepingindicator Turnonthesleepingcompanion, theindicatorlightisalwayson; Duringthesleepsetting, theindicatorlights flicker;turnoffthe sleepandtheindicator lightsgoout ⑥Wi-Fiindicator Nodistributionnetwork,icon slowflash; Distribution networkiconflash; distribution networksuccess, iconalwaysbright; brokennetwork status,icon extinguished ①/②Alarm Clock1/2 Click ①②③④⑤⑥ ①②③④⑤⑥⑦ Youcanviewthesetalarmclocktime; Canturnon alarmclock; canturnoff alarmclock; Duringthenoise,clickoncetostopthenoise;clickagaintoturnoffthealarm clock; Duringsleepopening,clicktheclockbuttontoturnoffsleep;clicktheclock buttonagaintoturnoffthealarmclock. Longpress Enteralarmclocksettings.SetHH(hours),MM(minutes),alarmclocksound effects(six)insequencebyclickingthealarmkey Optional),alarmclockvolume(level10adjustable),withtheuseof+/-key adjustmentoptions,aftercompletion,clickthealarmclockkeytoendthe setting,whilethealarmclockon. ③/⑤+/-key,Wi-Finetworkkey Duringsettingthealarmclockand sleeping,usethe+/-key adjustmentoption; Afterturningonthenightlight, youcanusethe+/-keytoadjust thebrightnessofthenightlight (level10adjustable); Press"+"-"atthesametimeto resettheWi-Fidistributionnetwork. 6Settings click Setscreenbrightness(day,night, auto,off) Longpress Entrytime,timeformat(12/24H); ByclickingtheSettingskey,you cansetHH(hourssequentially ),MM(minutes),12H/24H,with theuseofthe+/-keyadjustment option,aftercompletion,click thesettingskeytoendthe settings,returntothetime displayinterface. Functionexplanation Timedisplay 4.2inchlargewhiteLEDtime displaytimeisclear Brightnesscanbeadjustedtohigh duringtheday,lowatnight,orcan becompletelyclosedtolight sensitive(*seesettingkey operationfordetails) Timeformatsupports12/24Hand12 H.ScreendisplayAM/PM(*see setupkeyoperationfordetails) Automaticallysupportstimezonesand daylightsavingtime Wakeupalarmclock Twosetsofseparatealarmclocks, withsixnaturalsoundeffects,wakeup yourbody. Youcanset: Alarmclocktime,name,alarmclock repetition,alarmsoundeffect,noise soundeffect,volume,noisetime,sleep switch,sleepmode,sleeptime.(*See alarmkeyopera…
Text truncated - open the document above for the full version.
Shenzhen Juku Intelligent Technology Co., Ltd. Jan.08, 2021 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: Explanation of differences between product types FCC ID : 2ARPE-SNA006S Model Number: SNA006S, SNA006B To Whom It May Concern: We, The Shenzhen Juku Intelligent Technology Co., Ltd hereby declare that the model : SNA006B is identical with the model : SNA006S, except the model name. Except for the different above, no other modification is performed. Sincerely, Signature: Shenzhen Juku Intelligent Technology Co., Ltd. Contact person: Ason Chen
Shenzhen Juku Intelligent Technology Co., Ltd. Agent Authorization Company: Shenzhen Juku Intelligent Technology Co., Ltd. Address: 303, Building 12, Jinshun Industrial Zone, No.20 Huancheng South Road, Ma'antang Community, Bantian street, Longgang District, Shenzhen, China Product Name: Smart Night Light Alarm Clock Model Number(s): SNA006S, SNA006B Product Description: Smart Night Light Alarm Clock We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2021-01-08 Name: Ason Chen Company: Shenzhen Juku Intelligent Technology Co., Ltd.
Shenzhen Juku Intelligent Technology Co.,Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2021-01-07 Subject; Request for Confidentiality FCC ID: 2ARPE-SNA006S To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely Shenzhen Juku Intelligent Technology Co.,Ltd. Contact person: Ason Chen
External Photos ALL VIEW OF EUT TOP VIEW OF EUT BOTTOM VIEW OF EUT FRONT VIEW OF EUT BACK VIEW OF EUT LEFT VIEW OF EUT RIGHT VIEW OF EUT VIEW OF EUT (PORT)-1 VIEW OF ADAPTER
FCC ID Label Location FCC ID: 2ARPE-SNA006S
Internal Photos OPEN VIEW OF EUT-1 INTERNAL VIEW OF EUT-1 INTERNAL VIEW OF EUT-2 INTERNAL VIEW OF EUT-3 INTERNAL VIEW OF EUT-4 INTERNAL VIEW OF EUT-5 INTERNAL VIEW OF EUT-6 INTERNAL VIEW OF EUT-7 INTERNAL VIEW OF EUT-8 INTERNAL VIEW OF EUT-9 INTERNAL VIEW OF EUT-10 INTERNAL VIEW OF EUT-11 INTERNAL VIEW OF EUT-12 Antenna
RF EXPOSURE EVALUATION 1. PRODUCT INFORMATION Product Description Smart Night Light Alarm Clock Model Name SNA006S, SNA006B FCC ID 2ARPE-SNA006S 2. EVALUATION METHOD AND LIMIT Human exposure to RF emissions from mobile devices (47 CFR §2.1091) may be evaluated based on the MPE limits adopted by the FCC for electric and magnetic field strength and/or power density, as appropriate, since exposures are assumed to occur at distances of 20 cm or more from persons. LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE Frequency Range (MHz) E-field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Time |E| 2 , |H| 2 or S (Minutes) 0.3 -- 1.34 614 1.63 (100)* 30 1.34 -- 30 824/f 2.19/f (180/f 2 )* 30 30 -- 300 27.5 0.073 0.2 30 300 -- 1500 -- -- f/1500 30 1500 -- 100,000 -- -- 1.0 30 *Note: 1. f= Frequency in MHz * Plane-wave Equivalent Power Density 2. The averaging time for General Population/Uncontrolled exposure to fixed transmitters is not applicable for mobile and portable transmitters. See 47 CFR §§2.1091 and 2.1093 on source-based time-averaging requirement for mobile and portable transmitters. S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna CALCULATION A minimum test separation distance ≥ 20 cm is required between the antenna and radiating structures of the device and nearby persons to apply mobile device exposure limits. The distance must be at least 20 cm and fully supported by the operating and installation configurations of the transmitter and its antenna(s), according to the source-based time-averaged maximum power requirements of § 2.1091(d)(2). In cases where cable losses or other attenuations are applied to determine compliance, the most conservative operating configurations and exposure conditions must be evaluated. 2.4G WIFI Antenna Gain=1.0dBi (Numeric 1.26), π=3.14 Note: 1. Only the worst case recorded. 3. conclusion Compliance the RF exposure requirement Frequency Output Power Output Power Power Density Power Density Limit MHz dBm mW mW/cm 2 mW/cm 2 2462 16.70 46.77 0.0117 1
Page 1 of 79 Report No.: AGC09264201201FE05 FCC ID : 2ARPE-SNA006S APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Smart Night Light Alarm Clock BRAND NAME : N/A MODEL NAME : SNA006S, SNA006B APPLICANT : Shenzhen Juku Intelligent Technology Co., Ltd DATE OF ISSUE : Jan. 05, 2021 STANDARD(S) TEST PROCEDURE(S) : FCC Part 15.247 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd FCC Test Report Report No.: AGC09264201201FE05 Page 2 of 79 EPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Jan. 05, 2021 Valid Initial Release Report No.: AGC09264201201FE05 Page 3 of 79 TABLE OF CONTENTS 1. VERIFICATION OF CONFORMITY ............................................................................................................... 5 2. GENERAL INFORMATION ............................................................................................................................ 6 2.1. PRODUCT DESCRIPTION ..................................................................................................................... 6 2.2. TABLE OF CARRIER FREQUENCYS ..................................................................................................... 6 2.3. IEEE 802.11N MODULATION SCHEME .................................................................................................. 7 2.4. RELATED SUBMITTAL(S) / GRANT (S) .................................................................................................. 7 2.5. TEST METHODOLOGY .......................................................................................................................... 7 2.6. SPECIAL ACCESSORIES ....................................................................................................................... 7 2.7. EQUIPMENT MODIFICATIONS .............................................................................................................. 7 2.8. ANTENNA REQUIREMENT .................................................................................................................... 8 3. MEASUREMENT UNCERTAINTY ................................................................................................................. 9 4. DESCRIPTION OF TEST MODES ............................................................................................................... 10 5. SYSTEM TEST CONFIGURATION ............................................................................................................. 11 5.1. CONFIGURATION OF EUT SYSTEM .................................................................................................... 11 5.2. EQUIPMENT USED IN EUT SYSTEM .................................................................................................... 11 5.3. SUMMARY OF TEST RESULTS ............................................................................................................. 11 6. TEST FACILITY ........................................................................................................................................... 12 7. OUTPUT POWER ........................................................................................................................................ 13 7.1. MEASUREMENT PROCEDURE ........................................................................................................... 13 7.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ................................................................... 13 7.3. LIMITS AND MEASUREMENT RESULT ............................................................................................... 14 8. 6 DB BANDWIDTH ...................................................................................................................................... 15 8.1. MEASUREMENT PROCEDURE ........................................................................................................... 15 8.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ................................................................... 15 8.3. LIMITS AND MEASUREMENT RESULTS ............................................................................................. 16 9. CONDUCTED SPURIOUS EMISSION ........................................................................................................ 22 Report No.: AGC09264201201FE05 Page 4 of 79 9.1. MEASUREMENT PROCEDURE ........................................................................................................... 22 9.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ................................................................... 22 9.3. MEASUREMENT EQUIPMENT USEDJN ............................................................................................. 22 9.4. LIMITS AND MEASUREMENT RESULT ............................................................................................... 22 10. MAXIMUM CONDUCTED OUTPUT POWER SPECTRAL DENSITY ....................................................... 35 10.1 MEASUREMENT PROCEDURE .......................................................................................................... 35 10.2 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................. 35 10.3 MEASUREMENT EQUIPMENT USED ................................................................................................. 35 10.4 LIMITS AND MEASUREMENT RESULT .............................................................................................. 35 11. RADIATED EMISSION ............................................................................................................................... 42 11.1. MEASUREMENT PROCEDURE ......................................................................................................... 42 11.2. TEST SETUP ....................................................................................................................................... 43 11.3. LIMITS AND…
Text truncated - open the document above for the full version.
Report No.: AGC09264201201FE05 Page 41 of 79 TEST PLOT OF SPECTRAL DENSITY FOR HIGH CHANNEL Report No.: AGC09264201201FE05 Page 42 of 79 11. RADIATED EMISSION 11.1. MEASUREMENT PROCEDURE 1. The EUT was placed on the top of the turntable 0.8 or 1.5 meter above ground. The phase center of the receiving antenna mounted on the top of a height-variable antenna tower was placed 3 meters far away from the turntable. 2. Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to determine the position of the highest radiation. 3. The height of the broadband receiving antenna was varied between one meter and four meters above ground to find the maximum emissions field strength of both horizontal and vertical polarization. 4. For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the turntable was rotated (from 0 degree to 360 degrees) to find the maximum reading. 5. Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified bandwidth under Maximum Hold Mode. 6. For emissions above 1GHz, use 1MHz RBW and 3MHz VBW for peak reading. Place the measurement antenna away from each area of the EUT determined to be a source of emissions at the specified measurement distance, while keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. The measurement antenna may have to be higher or lower than the EUT, depending on the radiation pattern of the emission and staying aimed at the emission source for receiving the maximum signal. The final measurement antenna elevation shall be that which maximizes the emissions. The measurement antenna elevation for maximum emissions shall be restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane. 7. When the radiated emissions limits are expressed in terms of the average value of the emissions, and pulsed operation is employed, the measurement field strength shall be determined by averaging over one complete pulse train, including blanking intervals, as long as the pulse train does not exceed 0.1 seconds. As an alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases where the pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the average absolute voltage during a 0.1 second interval during which the field strength is at its maximum values. 8.If the emissions level of the EUT in peak mode was 3 dB lower than the average limit specified, then testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not have 3 dB margin will be repeated one by one using the quasi-peak method for below 1GHz. 9. For testing above 1GHz, the emissions level of the EUT in peak mode was lower than average limit (that means the emissions level in peak mode also complies with the limit in average mode), then testing will be stopped and peak values of EUT will be reported, otherwise, the emissions will be measured in average mode again and reported. 10. In case the emission is lower than 30MHz, loop antenna has to be used for measurement and the recorded data should be QP measured by receiver. High - Low scan is not required in this case. Report No.: AGC09264201201FE05 Page 43 of 79 11.2. TEST SETUP Radiated Emission Test-Setup Frequency Below 30MHz RADIATED EMISSION TEST SETUP 30MHz-1000MHz RADIATED EMISSION TEST SETUP ABOVE 1000MHz Report No.: AGC09264201201FE05 Page 44 of 79 11.3. LIMITS AND MEASUREMENT RESULT 15.209(a) Limit in the below table has to be followed Frequencies (MHz) Field Strength (micorvolts/meter) Measurement Distance (meters) 0.009~0.490 2400/F(KHz) 300 0.490~1.705 24000/F(KHz) 30 1.705~30.0 30 30 30~88 100 3 88~216 150 3 216~960 200 3 Above 960 500 3 Note: All modes were tested For restricted band radiated emission, the test records reported below are the worst result compared to other modes. 11.4. TEST RESULT RADIATED EMISSION BELOW 30MHZ The amplitude of spurious emissions from 9kHz to 30MHz which are attenuated more than 20 dB below the permissible value need not be reported. Report No.: AGC09264201201FE05 Page 45 of 79 RADIATED EMISSION BELOW 1GHZ EUT Smart Night Light Alarm Clock Model Name SNA006S Temperature 21.8°C Relative Humidity 58% Pressure 960hPa Test Voltage Normal Voltage Test Mode 802.11b with date rate 1 2412MHZ Antenna Horizontal RESULT: PASS Report No.: AGC09264201201FE05 Page 46 of 79 EUT Smart Night Light Alarm Clock Model Name SNA006S Temperature 21.8°C Relative Humidity 58% Pressure 960hPa Test Voltage Normal Voltage Test Mode 802.11b with date rate 1 2412MHZ Antenna Vertical RESULT: PASS Note: 1. Factor=Antenna Factor + Cable loss, Margin=Measurement-Limit. 2. The “Factor” value can be calculated automatically by software of measurement system. 3. All test modes had been pre-tested. The 802.11b at low channel is the worst case and recorded in the report. Report No.: AGC09264201201FE05 Page 47 of 79 RADIATED EMISSION ABOVE 1GHZ EUT Smart Night Light Alarm Clock Model Name SNA006S Temperature 21.8°C Relative Humidity 58% Pressure 960hPa Test Voltage Normal Voltage Test Mode 802.11b with date rate 1 2412MHZ Antenna Horizontal FrequencyMeter ReadingFactorEmission LevelLimitsMargin (MHz)(dBμV)(dB)(dBμV/m)(dBμV/m)(dB) 4824.00056.350.0856.4374-17.57 peak 4824.00046.290.0846.3754-7.63 AVG 7236.00050.182.2152.3974-21.61 peak 7236.00040.972.2143.1854-10.82 AVG Remark: Factor = Antenna Factor + Cable Loss – Pre-amplifier. Value Type EUT Smart Night Light Alarm Clock Model Name SNA006S Temperature 21.8°C Relative Humidity 58% Pressure 960hPa Test Voltage Normal Voltage Test Mode 802.11b with date rate 1 2412MHZ Antenna Vertical FrequencyMeter ReadingFactorEmission LevelLimitsMargin (MHz)(dBμV)(dB)(dBμV/m)(dBμV/m)(dB) 4824.00056.790.0856.8774-17.13 peak 4824.00047.330.0847.4154-6.59 AVG 7236.00051.562.2153.7774-20.23 peak 7236.00041.06…
Text truncated - open the document above for the full version.
Report No.: AGC09264201201FE05 Page 71 of 79 BACK VIEW OF EUT LEFT VIEW OF EUT Report No.: AGC09264201201FE05 Page 72 of 79 RIGHT VIEW OF EUT VIEW OF EUT (PORT)-1 Report No.: AGC09264201201FE05 Page 73 of 79 OPEN VIEW OF EUT-1 INTERNAL VIEW OF EUT-1 Report No.: AGC09264201201FE05 Page 74 of 79 INTERNAL VIEW OF EUT-2 INTERNAL VIEW OF EUT-3 Report No.: AGC09264201201FE05 Page 75 of 79 INTERNAL VIEW OF EUT-4 INTERNAL VIEW OF EUT-5 Report No.: AGC09264201201FE05 Page 76 of 79 INTERNAL VIEW OF EUT-6 INTERNAL VIEW OF EUT-7 Report No.: AGC09264201201FE05 Page 77 of 79 INTERNAL VIEW OF EUT-8 INTERNAL VIEW OF EUT-9 Report No.: AGC09264201201FE05 Page 78 of 79 INTERNAL VIEW OF EUT-10 INTERNAL VIEW OF EUT-11 Report No.: AGC09264201201FE05 Page 79 of 79 INTERNAL VIEW OF EUT-12 VIEW OF ADAPTER ----END OF REPORT---- Antenna Conditions of Issuance of Test Reports 1. All samples and goods are accepted by the Attestation of Global Compliance (Shenzhen) Co., Ltd (the “Company”) solely for testing and reporting in accordance with the following terms and conditions. The company provides its services on the basis that such terms and conditions constitute express agreement between the company and any person, firm or company requesting its services (the “Clients”). 2. Any report issued by Company as a result of this application for testing services (the “Report”) shall be issued in confidence to the Clients and the Report will be strictly treated as such by the Company. It may not be reproduced either in its entirety or in part and it may not be used for advertising or other unauthorized purposes without the written consent of the Company. The Clients to whom the Report is issued may, however, show or send it, or a certified copy thereof prepared by the Company to its customer, supplier or other persons directly concerned. The Company will not, without the consent of the Clients, enter into any discussion or correspondence with any third party concerning the contents of the Report, unless required by the relevant governmental authorities, laws or court orders. 3.The Company shall not be called or be liable to be called to give evidence or testimony on the Report in a court of law without its prior written consent, unless required by the relevant governmental authorities, laws or court orders. 4. The non-CMA report issued by AGC is only permitted to be used by the client as internal reference use and shall not be used for public demonstration purpose. 5. In the event of the improper use of the report as determined by the Company, the Company reserves the right to withdraw it, and to adopt any other additional remedies which may be appropriate. 6. Samples submitted for testing are accepted on the understanding that the Report issued cannot form the basis of, or be the instrument for, any legal action against the Company. 7. The Company will not be liable for or accept responsibility for any loss or damage however arising from the use of information contained in any of its Reports or in any communication whatsoever about its said tests or investigations. 8.Clients wishing to use the Report in court proceedings or arbitration shall inform the Company to that effect prior to submitting the sample for testing. 9. The Company is not responsible for recalling the electronic version of the original report when any revision is made to them. The Client assumes the responsibility to providing the revised version to any interested party who uses them. 10. Subject to the variable length of retention time for test data and report stored hereinto as otherwise specifically required by individual accreditation authorities, the Company will only keep the supporting test data and information of the test report for a period of six years. The data and information will be disposed of after the aforementioned retention period has elapsed. Under no circumstances shall we provide any data and information which has been disposed of after retention period. Under no circumstances shall we be liable for damage of any kind, including (but not limited to) compensatory damages, lost profits, lost data, or any form of special, incidental, indirect, consequential or punitive damages of any kind, whether based on breach of contract of warranty, tort (including negligence), product liability or otherwise, even if we are informed in advance of the possibility of such damages.
Test Setup Photos FCC RADIATED EMISSION TEST SETUP BELOW 1GHZ FCC RADIATED EMISSION TEST SETUP ABOVE 1GHZ CONDUCTED EMISSION TEST SETUP CONDUCTED TEST SETUP
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 138.70 mW |

Item Finder
Equipment Class
DTS - Digital Transmission System
RestOn White Noise Wake-Up Light
Equipment Class
DTS - Digital Transmission System
Smart Ambiance Light
Equipment Class
DTS - Digital Transmission System
Smart Ambiance Lamp With Alarm Clock
Equipment Class
DTS - Digital Transmission System
Smart Large Display Radio Clock
Equipment Class
DTS - Digital Transmission System