Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
(Shenzhen Juku Intelligent Technology Co., Ltd.) (September 9, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2ARPET2PRO) [Shenzhen Juku Intelligent Technology Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) Ason Chen (Shenzhen Juku Intelligent Technology Co., Ltd.) (September 9, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2ARPET2PRO) [Shenzhen Juku Intelligent Technology Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Ason Chen
Shenzhen Juku Intelligent Technology Co., Ltd. Model Difference Data:September 9, 2024 Product description: Item Finder Model name: T2 PRO, T2, T3, T3 Pro Trade Name: T2, T3, T3 Pro FCC ID: 2ARPET2PRO All the model are the same circuit and RF module, only the name and appearance are different. Regards Sincerely Client’s signature : Client’s name / title : Ason Chen(Manager) Contact information / address:Room 1009, Building 11, Tianan Yungu, Gangtou Community, Bantian Street, Longgang District, Shenzhen, Guangdong, China
Shenzhen Juku Intelligent Technology Co., Ltd. (September 9, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Item Finder / T2 PRO, T2, T3, T3 Pro / FCC ID: 2ARPET2PRO ) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: Ason Chen Title: Manager
Shenzhen Juku Intelligent Technology Co., Ltd. (September 9, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTB Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: Ason Chen Title: Manager
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 3 Model: T2 PRO External Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 3 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 3
FCC ID LABEL: Label Location: FCC ID: 2ARPET2PRO Model No.: T2 PRO
Shenzhen CTB Testing Co., Ltd. FCC ID:2ARPET2PRO Portable device According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to KDB447498 D01 General RF Exposure Guidance V06 The 1-g SAR and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHZ)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f(GHZ) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. BLE: Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculatio n SAR Exclusion threshold SAR test exclusion 2.402 1.652 1.46 1±1 2.00 1.58 <5 0.49127 3.00 YES 2.44 1.787 1.51 1±1 2.00 1.58 <5 0.49514 3.00 YES 2.480 1.351 1.36 1±1 2.00 1.58 <5 0.49918 3.00 YES GFSK Conclusion: For the max result : 0.49918≤ FCC Limit 3.0 for 1g SAR.
Product specification Quick Reference Date Antenna module on the system board Frequenc Range 2400 ~ 2500GHz Ant. Port Input Pwr. (dBm) 0 (Typ. BT class 2 output power) Tot. Rad. Pwr. (dBm) -1.2 (Input pwr – loss pwr) Peak EIRP(dBm) 0 Directivity (dBi) 1 (all direction antenna) Efficiency (dB) 1.0% Gain (dBi) 0 (Avg Gain XY-plane) Maximum Power (dBm) 0 (XY-plane) Minimum Power (dBm) 0(XY-plane) Avg. Power (dBm) 0(XY-plane) Input Impendence(ohm) 50 Polarization Type V ertical & Horizontal V . S .W . R < 6 All the technical data and information contained herein are subject to change without prior notice Antenna Layout & module on the system board 长:10.5mm 宽: 2.55mm Antenna Gain Gain Table Unit in dBi @2.44GHz XY-plane XZ-plane YZ-plane Efficiency Peak Avg. Peak Avg. Peak Avg. Module Board 0 0 0 0 0 0 0 Return Loss 3D radiation pattern diagram XY-plane XZ-plane YZ-plane Man ufacturer: Shenzhen Juku Intelligent Technology Co., Ltd. Address: Room 1009, Building 11, Tianan Yungu, Gangtou Community, Bantian Str eet, Longgang District, Shenzhen, Guangdong, China
TEST REPORT Compiled by: Reviewed by: Approved by: Zhou Kui Arron Liu Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Product Name: Item Finder FCC ID: 2ARPET2PRO Trademark: DEKALA Model Number: T2 PRO, T2, T3, T3 Pro Prepared For: Shenzhen Juku Intelligent Technology Co., Ltd. Address: Room 1009, Building 11, Tianan Yungu, Gangtou Community, Bantian Street, Longgang District, Shenzhen, Guangdong, China Manufacturer: Shenzhen Juku Intelligent Technology Co., Ltd. Address: Room 1009, Building 11, Tianan Yungu, Gangtou Community, Bantian Street, Longgang District, Shenzhen, Guangdong, China Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Aug. 28, 2024 Sample tested Date: Aug. 28, 2024 to Aug. 31, 2024 Issue Date: Aug. 31, 2024 Report No.: CTB240831061RFX Test Standards FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10:2013 Test Results PASS Remark: This is Bluetooth radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB240831061RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 33 TABLE OF CONTENT Test Report Declaration Page 1. VERSION .......................................................................................................................................... 3 2. TEST SUMMARY ............................................................................................................................. 4 3. MEASUREMENT UNCERTAINTY ................................................................................................... 5 4. PRODUCT INFORMATION AND TEST SETUP ............................................................................. 6 4.1 Product Information ............................................................................................................................ 6 4.2 Test Setup Configuration ................................................................................................................... 6 4.3 Support Equipment ............................................................................................................................ 6 4.4 Channel List ....................................................................................................................................... 7 4.5 Test Mode .......................................................................................................................................... 7 4.6 Test Environment ............................................................................................................................... 7 5. TEST FACILITY AND TEST INSTRUMENT USED ......................................................................... 8 5.1 Test Facility ........................................................................................................................................ 8 5.2 Test Instrument Used ......................................................................................................................... 8 6. AC POWER LINE CONDUCTED EMISSION .................................................................................. 11 6.1 Block Diagram Of Test Setup ........................................................................................................... 11 6.2 Limit .................................................................................................................................................. 11 6.3 Test procedure ................................................................................................................................. 11 6.4 Test Result ....................................................................................................................................... 13 7. RADIATED SPURIOUS EMISSION ............................................................................................... 14 7.1 Block Diagram Of Test Setup ........................................................................................................... 14 7.2 Limit .................................................................................................................................................. 14 7.3 Test procedure ................................................................................................................................. 15 7.4 Test Result ....................................................................................................................................... 16 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS ................................................ 23 8.1 Block Diagram Of Test Setup ........................................................................................................... 23 8.2 Limit .................................................................................................................................................. 23 8.3 Test procedure ................................................................................................................................. 23 8.4 Test Result ....................................................................................................................................... 24 9. COUDUCTED OUTPUT POWER ..............................................................…
Text truncated - open the document above for the full version.
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 1 Model: T2 PRO Radiated Emission Below 1G Above 1G
Room 1009, Building 11, Tianan Yungu, · Shenzhen, Guangdong, · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.51 mW |

RestOn White Noise Wake-Up Light
Equipment Class
DTS - Digital Transmission System
Smart Ambiance Light
Equipment Class
DTS - Digital Transmission System
Smart Ambiance Lamp With Alarm Clock
Equipment Class
DTS - Digital Transmission System
Smart Night Light Alarm Clock
Equipment Class
DTS - Digital Transmission System
Smart Large Display Radio Clock
Equipment Class
DTS - Digital Transmission System