2AS8ABPMB003Upper Arm Type Blood Pressure Monitor

Shenzhen Jamr Technology Co., Ltd
Upper Arm Type Blood Pressure Monitor - FCC ID 2AS8ABPMB003 - Shenzhen Jamr Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 10, 2023
Application Purpose
Original Equipment
Date of Application
Apr 10, 2023
Equipment Note
Upper Arm Type Blood Pressure Monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Jamr Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

               材质: 内页普通80g书写纸, 成品尺寸:100×140mm 400mm 420mm 3. Components of your blood pressure monitor 4. Using your Monitor for the First Time 6.Care and Maintenance 2.Important Information on Blood Pressure and its Measurement 2.1. How does high or low blood pressure arise? Your level of blood pressure is determined in the circulatory center of the brain and adjusts to a variety of situations through feedback from the nervous system. To adjust blood pressure, the strength and speed of the heart (Pulse), as well as the width of circulatory blood vessels is altered.Blood vessel width is controlled by fine muscles in the blood vessel walls. Your level of arterial blood pressure changes periodically during heart activity: During the “blood ejection” (Systole) the value is highest (systolic blood pressure value). At the end of the heart’s “rest period” (Diastole) pressure is lowest (diastolic blood pressure value). There are six grids in the display of device. Please refer to the picture-01-01. Different grids represent different interval scales of WHO. 2.2. Which values are normal? Use only 1.5V “AA” alkaline batteries with this device. 1. Press the hook on the bottom of the battery cover and lift the cover off in the direction of the arrow (Picture-04). 2. Install 3 “AA” size batteries and make sure the + (positive) and - (negative) polarities match the polarities of the battery compartment, then close the battery cover.Make sure that the battery cover is securely in position. 4.1 Activating the pre-installed batteries Battery Installation Each unit stores 120 sets measurements for 2 users,totally 240 sets (User 1 and 2).Measurements for each user are stored separately. Be certain that you are viewing the measurements for the correct user. 5.6. Memory With the unit off, press the ( ) button. The monitor will display User ID and an average value of the last 3 times measurements stored in the unit. ( If measurements are less than 3 sets, directly display the first set ) Turn the knob clockwise, it will display the memory value from the latest to the oldest in turn. Turn the knob counterclockwise, it will display the memory value from the oldest to the latest in turn. B. Switch user memory When viewing the memory, press the ( ) button ,it will switch the User ID, and then display another user memory value . A.View the memory 5. Measurement Procedure • Avoid eating and smoking as well as all forms of exertion directly before measurement. These factors influence the measurement result. Find time to relax by sitting in an armchair in a quiet atmosphere for about ten minutes before taking a measurement. • Remove any garment that fits closely to your upper arm. • Always measure on the same arm (normally left). 5.1. Before measurement: Please refer to picture-05 a) Wrap the cuff around your upper left arm. The rubber tube should be on the inside of your arm extending downward to your hand. Make certain the cuff lies approximately 2 to 3 cm above the elbow. Important! The on the edge of the cuff (Artery Mark) must lie over the artery which runs down the inner side of the arm. b) To secure the cuff, wrap it around your arm and press the hook and loop closure together. c) There should be little free space between your arm and the cuff. You should be able to fit 2 fingers between your arm and the cuff. Cuffs that don’t fit properly result in false measurement values. Measure your arm circumference if you are not sure of proper fit. d) Lay your arm on a table (palm upward) so the cuff is at the same height as your heart. Make sure the tube is not kinked. 5.2. Fitting the Cuff Patient Position: 1) Comfortably seated2) Legs uncrossed 3) Feet flat on the floor4) Back and arm supported 5) Middle of the CUFF at the level of the right atrium of the heart NOTE: The following symbols may appear in this manual, on the Digital Blood Pressure Monitor , or on it's accessories. Some of the symbols represent standards and compliances associated with the Digital Blood Pressure Monitor and its use. This symbol( ) - indicates that certain pulse irregularities were detected during the measurement. In this case, the result may deviate from your normal basal blood pressure – repeat the measurement. Information for the physician on frequent appearance of the Irregular Heartbeat Symbol. This instrument is an oscillometric blood pressure monitor device that also analyzes pulse frequency during measurement. The instrument is clinically tested. If pulse irregularities occur during measurement, the irregular heartbeat symbol is displayed after the measurement. If the symbol appears more frequently (e.g. several times per week on measurements performed daily) or if it suddenly appears more often than usual, we recommend the patient to seek medical advice. The instrument does not replace a cardiac examination, but serves to detect pulse irregularities at an early stage. 5.4. Irregular Heartbeat Detector 5.5. Error Indicates Battery replacement Please refer to the diagram below(Picture-01) Picture-05 Picture-06 The following symbol will appear on the display when measuring abnormal SYMBOL DESCRIPTIONS Guidance and manufacture’s declaration – electromagnetic emission The device is intended for use in the electromagnetic environment specified below. The customer of the user of the device should assure that it is used in such an environment. Guidance and manufacturer’s declaration - electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device, should assure that it is used in such an environment. Emission test RF emissions CISPR 11 ComplianceElectromagnetic environment – guidance Group 1 The device use RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. The device is suitable for use in all establishments, incl…

Text truncated - open the document above for the full version.

Attestation Statements

Rev 1/26/2023 Shenzhen Jamr Technology Co., Ltd Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 03.31, 2023 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2AS8ABPMB003 [Shenzhen Jamr Technology Co., Ltd] certifies that, as of the date of the filing of the application, Performance International,Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. xufeng.chen accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Performance International,Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Performance International,Inc. Address: 2816 Sunset Ave.,Rocky Mount,NC 27804,USA Contact Person: xufeng.chen Tel.: 001-919-859-0478 Email: [email protected] FCC Registration Number (FRN): 0033538125 Sincerely, Fusheng Luo xufeng.chen Shenzhen Jamr Technology Co., Ltd Performance International,Inc.

Attestation Statements

Shenzhen Jamr Technology Co., Ltd 03-31-2023 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2AS8ABPMB003) [Shenzhen Jamr Technology Co., Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Fusheng Luo Shenzhen Jamr Technology Co., Ltd 03-31-2023 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2AS8ABPMB003) [Shenzhen Jamr Technology Co., Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Fusheng Luo

Cover Letter(s)

Shenzhen Jamr Technology Co., Ltd Agent Authorization Letter 2023-03-31 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 USA RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Shenzhen Most Technology Service Co., Ltd. to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Name: Fusheng Luo Position: RA Manager Company Name: Shenzhen Jamr Technology Co., Ltd Address: A101-301,D101-201,Jamr Science&Technolog Park,No.2 Guiyuan Road,Guanlan Street,Longhua District,China Tel / Fax 86-755-85292057 / 86-755-27980758 E-Mail: [email protected]

Cover Letter(s)

Shenzhen Jamr Technology Co., Ltd Long Term Confidentiality Request Letter 2023.03.31 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 USA RE: CONFIDENTIALITY REQUEST FOR (FCC ID: 2AS8ABPMB003) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - e.g. Block diagram - e.g. SCH - e.g. Operational Description required to be submitted with this application be permanently withheld from public review. The above documents are company proprietary information that could never get into the possession of your competition. Please contact me if there is any information you may need. Sincerely, Name: Fusheng Luo Position: RA Manager Company Name: Shenzhen Jamr Technology Co., Ltd Address: A101-301,D101-201,Jamr Science&Technolog Park,No.2 Guiyuan Road,Guanlan Street,Longhua District,China Tel / Fax 86-755-85292057 / 86-755-27980758 E-Mail: [email protected]

Cover Letter(s)

Modeldifferenceletter 2023.04.11 DearEurofinsReviewer, ThisisanewApplicationfromShenzhenJamrTechnologyCo.,Ltd ModelNo.:BA31T 、 BD31T 、 B23MT UseBA31Tforalltests . sincetheelectricalcircuitdesign,layout,components usedandinternalwiringwereidenticalfortheabovemodels,withdifference beingmodelnameandappearance. Thankyouforyourcooperation! Yourssincerely, Signatory: Name:FushengLuo Position:RAManager CompanyName:ShenzhenJamrTechnologyCo.,Ltd Address:A101-301,D101-201,JamrScience&TechnologPark,No.2Guiyuan Road,GuanlanStreet,LonghuaDistrict,China Tel/Fax86-755-85292057/86-755-27980758 E-Mail:[email protected]

External Photos

Model No.: BA31T FRONT VIEW OF SAMPLE BACK VIEW OF SAMPLE Model No.: BA31T LEFT VIEW OF SAMPLE RIGHT VIEW OF SAMPLE Model No.: BA31T TOP VIEW OF SAMPLE FRONT VIEW OF SAMPLE Model No.: BA31T

Internal Photos

Model No.: BA31T Page 1 of 4 INTERNAL PHOTO OF SAMPLE INTERNAL PHOTO OF SAMPLE Model No.: BA31T Page 2 of 4 INTERNAL PHOTO OF SAMPLE INTERNAL PHOTO OF SAMPLE PCB Antenna Model No.: BA31T Page 3 of 4 INTERNAL PHOTO OF SAMPLE PCB INTERNAL PHOTO OF SAMPLE PCB Model No.: BA31T Page 4 of 4 INTERNAL PHOTO OF SAMPLE PCB INTERNAL PHOTO OF SAMPLE PCB

RF Exposure Info

Shenzhen Most Technology Service Co., Ltd. No.5, 2nd Langshan Road, North District, Hi-tech Industrial Park, Nanshan, Shenzhen, Guangdong, China. RF Exposure Evaluation Report Report Reference No. ..................... : FCC ID.. ........................................... : MTEB23030279-H 2AS8ABPMB003 Compiled by ( position+printed name+signature) .. : File administrators Alisa Luo Supervised by ( position+printed name+signature) .. : Test Engineer Sunny Deng Approved by ( position+printed name+signature) .. : Manager Yvette Zhou Date of issue ..................................... : February 13,2023 Representative Laboratory Name .: Shenzhen Most Technology Service Co., Ltd. Address ............................................ : No.5, 2nd Langshan Road, North District, Hi-tech Industrial Park, Nanshan, Shenzhen, Guangdong, China. Applicant’s name ............................ : Shenzhen Jamr Technology Co., Ltd Address ............................................ : A101-301, D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road, Guixiang Community,Guanlan Street, Longhua District, 518100 Shenzhen, PEOPLE'S REPUBLIC OF CHINA Test specification/ Standard ..........: 47 CFR Part 1.1307 47 CFR Part 2.1093 TRF Originator .................................. : Shenzhen Most Technology Service Co., Ltd. Shenzhen Most Technology Service Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Most Technology Service Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen Most Technology Service Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .....................: Upper Arm Type Blood Pressure Monitor Trade Mark ....................................... : N/A Model/Type reference....................... : Shenzhen Jamr Technology Co., Ltd Listed Models .................................. : BA31T Modulation Type ............................... : BD31T、B23MT Operation Frequency ........................ : GFSK Bluetooth version .............................. : BT 5.3 Hardware Version .............................. From 2402MHz to 2480MHz Software Version ............................... JMR-SCH-BA31T-AC621-A-V1.1 Rating ............................................... : V1 Result................................................ : DC4.5V(by Batteries) DC5V Result................................................ : PASS Report No.: MTEB23030279-H Page 2 of 5 T E S T R E P O R T Equipment under Test : Upper Arm Type Blood Pressure Monitor Model /Type : BA31T Listed Models BD31T、B23MT Remark Only the model name and appearance are different Applicant : Shenzhen Jamr Technology Co., Ltd Address : A101-301, D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road, Guixiang Community,Guanlan Street, Longhua District, 518100 Shenzhen, PEOPLE'S REPUBLIC OF CHINA Manufacturer : Shenzhen Jamr Technology Co., Ltd Address : A101-301, D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road, Guixiang Community,Guanlan Street, Longhua District, 518100 Shenzhen, PEOPLE'S REPUBLIC OF CHINA Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: MTEB23030279-H Page 3 of 5 1. R e v i s i o n H i s t o r y Revision Issue Date Revisions Revised By 00 2023.03.22 Initial Issue Alisa Luo Report No.: MTEB23030279-H Page 4 of 5 2. S A R E v a l u a t i o n 2.1 RF Exposure Compliance Requirement 2.1.1 Standard Requirement According to KDB447498D01 General RF Exposure Guidance v06 4.3.1. Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed below, is satisfied. 2.1.2 Limits The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion Report No.: MTEB23030279-H Page 5 of 5 2.1.3 EUT RF Exposure Measurement Data BLE GFSK Test channel Peak Output Power (dBm) Tune up tolerance (dBm) Maximum tune-up Power (dBm) Lowest(2402MHz) -1.535 -1.535±1 0.535 Middle(2441MHz) -1.139 -1.139±1 0.139 Highest(2480MHz) -0.854 -0.854±1 0.146 Worst case: GFSK Channel Maximum Peak Conducted Output Power (dBm) Maximum tune-up Power Calculated value Exclusion threshold SAR Test Exclusion (dBm) (mW) Highest (2480MHz) -0.854 0.146 1.03 0.33 3.0 Yes .......................THE END OF REPORT.........................

Test Report

EUT Name Upper Arm Type Blood Pressure Monitor Model No. Inverted-L Antenna Environmental Conditions 21.4°C/43%RH/101kPa Test Scene Scene 1 Power Supply / Tested By Xu Xing Qiu Test Date 2023/3/13 Sample No. E202212139826-0003 Antenna polarizatiob / Impedance 50 Ω Antenna photo and length(mm) Frequency(MHz)Gain(dBi)Efficiency(%) AverageGain(dBi) Effciency(dB) 2400-7.3716.20%-12.801-12.079 2410-6.966.76%-12.312-11.7 2420-6.5827.45%-11.891-11.279 2430-6.9786.92%-12.292-11.602 2440-7.3786.32%%-12.698-11.996 2450-7.2376.42%-12.586-11.925 2460-7.0956.71%-12.233-11.735 2470-6.8117.36%-11.631-11.333 2480-6.3018.53%-10.864-10.692 2490-6.0759.13%-10.614-10.394 2500-6.1068.77%-10.998-10.571 Shenzhen Jamr Technology Co., Ltd A101-301, D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road, Guixiang Community,Guanlan Street, Longhua District, 518100 Shenzhen, PEOPLE'S REPUBLIC OF CHINA Frequency(MHz)24002410242024302440245024602470248024902500 Gain(dBi)-7.371-6.96-6.58-6.98-7.378-7.237-7.095-6.811-6.301-6.075-6.106 Frequency(MHz)24002410242024302440245024602470248024902500 Efficiency(%)6.20%6.76%7.45%6.92%6.32%6.42%6.71%7.36%8.53%9.13%8.77% 2400Mhz 90 Total(H-XY) 2400Mhz 0 Total(E1-XZ) 2400Mhz 90 Total(E2-YZ) 2410Mhz 90 Total(H-XY) 2410Mhz 0 Total(E1-XZ), 2410Mhz 90 Total(E2-YZ) 2420Mhz 90 Total(H-XY) 2420Mhz 0 Total(E1-XZ), 2420Mhz 90 Total(E2-YZ) 2430Mhz 90 Total(H-XY) 2430Mhz 0 Total(E1-XZ) 2430Mhz 90 Total(E2-YZ) 2440Mhz 90 Total(H-XY) 2440Mhz 0 Total(E1-XZ), 2440Mhz 90 Total(E2-YZ) 2450Mhz 90 Total(H-XY) 2450Mhz 0 Total(E1-XZ), 2450Mhz 90 Total(E2-YZ) 2460Mhz 90 Total(H-XY) 2460Mhz 0 Total(E1-XZ), 2460Mhz 90 Total(E2-YZ) 2470Mhz 90 Total(H-XY) 2470Mhz 0 Total(E1-XZ), 2470Mhz 90 Total(E2-YZ) 2480Mhz 90 Total(H-XY) 2480Mhz 0 Total(E1-XZ) 2480Mhz 90 Total(E2-YZ) 2490Mhz 90 Total(H-XY) 2490Mhz 0 Total(E1-XZ), 2490Mhz 90 Total(E2-YZ) 2500Mhz 90 Total(H-XY) 2500Mhz 0 Total(E1-XZ) 2500Mhz 90 Total(E2-YZ) 2400 2450 2500

Test Report

Shenzhen Most Technology Service Co., Ltd. No.5, 2nd Langshan Road, North District, Hi-tech Industrial Park, Nanshan, Shenzhen, Guangdong, China. TEST REPORT FCC Rules Part 15.247 Report Reference No. ..................... : FCC ID.. ........................................... : MTEB23030279-R 2AS8ABPMB003 Compiled by ( position+printed name+signature) .. : File administrators Alisa Luo Supervised by ( position+printed name+signature) .. : Test Engineer Sunny Deng Approved by ( position+printed name+signature) .. : Manager Yvette Zhou Date of issue ..................................... : March22,2023 Representative Laboratory Name .: Shenzhen Most Technology Service Co., Ltd. Address ............................................ : No.5, 2nd Langshan Road, North District, Hi-tech Industrial Park, Nanshan, Shenzhen, Guangdong, China. Applicant’s name ............................ : Shenzhen Jamr Technology Co., Ltd Address ............................................ : A101-301, D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road, Guixiang Community,Guanlan Street, Longhua District, 518100 Shenzhen, PEOPLE'S REPUBLIC OF CHINA Test specification/ Standard ..........: FCC Rules Part 15.247 TRF Originator .................................. : Shenzhen Most Technology Service Co., Ltd. Shenzhen Most Technology Service Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Most Technology Service Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen Most Technology Service Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .....................: Upper Arm Type Blood Pressure Monitor Trade Mark ...........................: N/A Manufacturer .................................... : Shenzhen Jamr Technology Co., Ltd Model/Type reference....................... : BA31T Listed Models .................................. : BD31T、B23MT Modulation Type ............................... : GFSK Bluetooth version .............................. : BT 5.3 Operation Frequency ........................ : From 2402MHz to 2480MHz Hardware Version .............................. JMR-SCH-BA31T-AC621-A-V1.1 Software Version ............................... V1 Rating ............................................... : DC4.5V(by Batteries) DC5V Result................................................ : PASS Report No.: MTEB23030279-R Page 2 of 34 T E S T R E P O R T Equipment under Test : Upper Arm Type Blood Pressure Monitor Model /Type : BA31T Listed Models BD31T、B23MT Remark Only the model name and appearance are different Applicant : Shenzhen Jamr Technology Co., Ltd Address : A101-301, D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road, Guixiang Community,Guanlan Street, Longhua District, 518100 Shenzhen, PEOPLE'S REPUBLIC OF CHINA Manufacturer : Shenzhen Jamr Technology Co., Ltd Address : A101-301, D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road, Guixiang Community,Guanlan Street, Longhua District, 518100 Shenzhen, PEOPLE'S REPUBLIC OF CHINA Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: MTEB23030279-R Page 3 of 34 Contents 1. R E V I S I O N H I S T O R Y ................................................................ 4 2. T E S T S T A N D A R D S ................................................................. 5 3. S U M M A R Y ............................................................................ 6 3.1. General Remarks 6 3.2. Product Description 6 3.3. Equipment Under Test 6 3.4. Short description of the Equipment under Test (EUT) 6 3.5. EUT operation mode 7 3.6. Block Diagram of Test Setup 7 3.7. Test Item (Equipment Under Test) Description* 7 3.8. Auxiliary Equipment (AE) Description 7 3.9. Antenna Information* 8 3.10. EUT configuration 8 3.11. Modifications 8 4. T E S T E N V I R O N M E N T .............................................................. 9 4.1. Address of the test laboratory 9 4.2. Environmental conditions 9 4.3. Test Description 10 4.4. Statement of the measurement uncertainty 10 4.5. Equipments Used during the Test 11 5. T E S T C O N D I T I O N S A N D R E S U L T S ........................................... 12 5.1. AC Power Conducted Emission 12 5.2. Radiated Emission 15 5.3. Maximum Peak Output Power 22 5.4. Power Spectral Density 23 5.5. 6dB Bandwidth and 99% Bandwidth 25 5.6. Band Edge Compliance of RF Emission 27 5.7. Spurious RF Conducted Emission 29 5.8. Antenna Requirement 32 6. T E S T S E T U P P H O T O S O F T H E E U T ......................................... 33 7. E X T E R N A L A N D I N T E R N AL P H O T O S O F T H E E U T ...................... 34 Report No.: MTEB23030279-R Page 4 of 34 1. R e v i s i o n H i s t o r y Revision Issue Date Revisions Revised By 00 2023.03.22 Initial Issue Alisa Luo Report No.: MTEB23030279-R Page 5 of 34 2. T E S T S T A N D A R D S The tests were performed according to following standards: The tests were performed according to following standards: FCC Rules Part 15.247: Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz. ANSI C63.10:2013 : American National Standard for Testing Unlicensed Wireless Devices Report No.: MTEB23030279-R Page 6 of 34 3. S U M M A R Y 3.1. General Remarks Date of receipt of test sample : 2023.03.19 Testing commenced on : 2023.03.20 Testing concluded on : 2023.03.22 3.2. Product Description Product Name: Upper Arm Type Blood Pressure Monitor Model/Type reference: BA31T Power Supply: DC4.5V(by Batteries) DC5V Testing sample ID: MTX23030212 Bluetooth : Supported Type: BLE Modul…

Text truncated - open the document above for the full version.

Test Setup Photos

Model No.: BA31T RE TEST SETUP RE TEST SETUP Model No.: BA31T CE TEST SETUP

Contact Information

Applicant

Luo Fusheng(RA Manager)
[email protected]86-755-85292057Fax: 86-755-27980758

Test Firm

Shenzhen Most Technology Service Co., Ltd.Sunny Deng
[email protected]0755-26980487

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz800.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Shenzhen Jamr Technology Co., Ltd

Blood Pressure Monitor - FCC ID 2AS8A-BE23T - Shenzhen Jamr Technology Co., Ltd
2AS8A-BE23T

Blood Pressure Monitor

Oct 07, 2024

Equipment Class

DTS - Digital Transmission System
2AS8AB73T

Blood Pressure Monitor

Sep 18, 2024

Equipment Class

DTS - Digital Transmission System
Blood Pressure Monitor - FCC ID 2AS8AB72T - Shenzhen Jamr Technology Co., Ltd
2AS8AB72T

Blood Pressure Monitor

Sep 18, 2024

Equipment Class

DTS - Digital Transmission System
Blood Pressure Monitor - FCC ID 2AS8AF1703T - Shenzhen Jamr Technology Co., Ltd
2AS8AF1703T

Blood Pressure Monitor

Aug 19, 2024

Equipment Class

DTS - Digital Transmission System
Upper Arm Type Blood Pressure Monitor - FCC ID 2AS8ABPMB002 - Shenzhen Jamr Technology Co., Ltd
2AS8ABPMB002

Upper Arm Type Blood Pressure Monitor

Apr 03, 2023

Equipment Class

DTS - Digital Transmission System