Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
WFMesh.Gateway.Module-106 Product Manual www.eybond.comShenzhenYibangSunshineCo., LTD. All rights reserved 1 / 10 WFMesh.Gateway.Module-106 ProductManual ShenzhenYibangSunshineCo., LTD (All rights reserved,reproductionis prohibited) WFMesh.Gateway.Module-106 Product Manual www.eybond.comShenzhenYibangSunshineCo., LTD. All rights reserved 2 / 10 Historicalversion Document version revise contentmodifierdateremarks V1.0editio princepsDuongHuy2022-10-27 V1.1reviseCao Ziqiang2024-09-14 V1.2 Updatethe APP interfaceimage and usage description Cao Ziqiang2025-09-08 WFMesh.Gateway.Module-106 Product Manual www.eybond.comShenzhenYibangSunshineCo., LTD. All rights reserved 3 / 10 Catalogue 1.Productoverview--------------------------------------------------------------------------4 2.Referencecircuit diagram-------------------------------------------------------------------5 2.1 Electricalconnections-----------------------------------------------------------------5 2.1.1 Applicationcircuits-------------------------------------------------------------5 2.1.2 Power supply------------------------------------------------------------------5 2.1.3 Antennalayout requirements------------------------------------------------------5 2.2 Networkconnectivity-----------------------------------------------------------------6 2.2.1 Login and Registration-----------------------------------------------------------6 2.2.2 Add equipment-----------------------------------------------------------------7 2.2.3 Networkingconfiguration--------------------------------------------------------7 3.Commonfaults---------------------------------------------------------------------------9 4. Notes----------------------------------------------------------------------------------10 WFMesh.Gateway.Module-106 Product Manual www.eybond.comShenzhenYibangSunshineCo., LTD. All rights reserved 4 / 10 1.Productoverview WFBLE.DTU.Module-102extendsthe Wi-Fitransmissionchannelfor devices.Featuringa 2nd-gener ation IPEX antenna,this productdeliversfast data transferand free applicationsupport.It connectsto d evice processingboardsvia serial port with stronganti-interferencecapabilities,enablingremotecontrol, debugging,and firmwareupdates.Throughrouteraccessto cloud servers,it providesusers with a low-c ost, visualized,and fully remote-operatedmonitoringsolution.Currentlyavailablein three configurations: onboardantenna,2nd-generationIPEX base station,and ANT Wi-Fi/BT,users can select the most suitabl e adaptationplan accordingto their specificrequirements. pinPin namedescription 1ANT Wi-Fi/BLEantenna,the antennapositionneeds to avoid air, no metal or coppersheet 2GNDModularlogic 3WDI The watchdogfeeds the dog an output pin that outputsa square wave signal of 1Hz 4BUZZER/DL Beeperoutput,power on the opportunityto output high level/moduleprogram downloadport. 5SRV The SRV indicatorlight outputsa low level when poweredon and turned on. When connectedto the server,it is pulled low 6NET NET indicatorlight, which outputsa low level when poweredon and turned on. When connectedto the network,it is pulled low 7COM COM indicatorlight, power on and output low level, which is pulled low after communicationwith the device. 8RXDTTL serial level input pin 9TXDTTL serial port level output pin 10RSTReset the parameterpins, low level effective WFMesh.Gateway.Module-106 Product Manual www.eybond.comShenzhenYibangSunshineCo., LTD. All rights reserved 5 / 10 2.Referencecircuitdiagram 2.1 Electricalconnections 2.1.1 Applicationcircuits Note: The IO port of the moduleis 3.3V. If the externallevel does not match,a level conversioncircuit needs to be added. 2.1.2 Powersupply (1) Recommended3.3V voltage,peak currentabove 500mA (2) It is recommendedto use LDO power supply;if DC-DCis used, the ripple controlshouldbe less than 30mV. 2.1.3 Antennalayoutrequirements (1) For the installationpositionon the main board, two methodsare recommended: Scheme1: Place the moduleon the edge of the motherboard,and extendthe antennaarea beyondthe edge of the motherboard. Scheme2: Place the moduleon the edge of the motherboard,and hollowout a region at the antennapositionon the edge of the motherboard. (2) In order to meet the performanceof the onboardantenna,metal parts are prohibitedaroundthe antennaand high frequencydevicesare kept away. WFMesh.Gateway.Module-106 Product Manual www.eybond.comShenzhenYibangSunshineCo., LTD. All rights reserved 6 / 10 2.2 Networkconnectivity 2.2.1 Login and Registration (1) Scan the QR code and downloadthe APP; (2) Click the registrationbelow to enter the accountregistrationpage; (3) After enteringthe mobilephone numberor email address,click "Get verificationcode", enter the verification code received,and set the password.Click "Registerimmediately"to completethe registration. WFMesh.Gateway.Module-106 Product Manual www.eybond.comShenzhenYibangSunshineCo., LTD. All rights reserved 7 / 10 2.2.2 Add equipment (1) On the "monitoring"page, click "Add device"; (2)Click "Scan code to add" and scan the QR code on the modulecover. 2.2.3 Networkingconfiguration (1) Enter the networkconfigurationpage, fill in the relevantrouter informationas prompted,and click "Start networking"; WFMesh.Gateway.Module-106 Product Manual www.eybond.comShenzhenYibangSunshineCo., LTD. All rights reserved 8 / 10 (2) After enteringthe configuration,wait for 30 seconds.The APP will give feedbackaccordingto the distribution networkresults: i. If the distributionnetworkis successful,the additionis successful.After about 5~10 minutes,the equipmentdata can be viewednormally; ii. If the configurationfails, troubleshootthe problemaccordingto the "Diagnosisand Repair Suggestions". WFMesh.Gateway.Module-106 Product Manual www.eybond.comShenzhenYibangSunshineCo., LTD. All rights reserved 9 / 10 3.Commonfaults When you encounterthe followingproblems,please refer to the followingsolutionsfirst. If the problemis still not solved,please contactour after-salespersonnel. Tel: +86-755-89992588 Email:mar…
Text truncated - open the document above for the full version.
1/1 USAgentforServiceofProcessLETTEROFATTESTATION TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USAgentforServiceofProcess: Companyname:HOPEKCORPORATIONINC FRN:0034562900 ContactName:PeterDavis Address:16755CoyoteBushDrUnit84,SanDiego,CA92127UnitedStates TelephoneNo:561-235-6113 Email:[email protected] Applicant: Companyname:ShenzhenEybondCo.,Ltd GranteeCode:2ASAF FCCID:2ASAF-MODULE-106 FRN:0028152866 ContactName:Menciusmeng Address:Building10,ZhihengScience&TechnologyPark,NantouStreet,Nanshan District,ShenzhenCity,GuangdongProvince,China. TelephoneNo: 0755-89992588 FaxNo: 0755-89992588 Email: [email protected] ShenzhenEybondCo.,Ltdcertifiesthat,asofthedateofthisfilingoftheapplicationwiththe TCB,[HOPEKCORPORATIONINC]isourdesignatedUSagentforserviceofprocessforthe abovereferencedFCCID.ShenzhenEybondCo.,Ltdacceptstomaintainanagentforno lessthanoneyearafterthegranteehasterminatedallmarketingandimportationorthe conclusionofanycommissionrelatedproceedinginvolvingequipment.[HOPEK CORPORATIONINC]accepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedUSagentforserviceofprocessfortheabovereferenceFCCID. TheUSAgentforServiceofProcessisawareofandagreestocomplywiththerequirements outlinedintheFCCEquipmentAuthorizationProgram,ReportandOrderFCC22-84,and clause§2.911. TheApplicantisawareofandagreestocomplywiththerequirementsoutlinedintheFCC EquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause§2.911. Date:2026-01-08 Applicant’sName:MenciusmengUSAgent’sName:PeterDavis Title:DirectorofR&DTitle:Manager Signature:Signature:
Shenzhen Eybond Co., Ltd January 8, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2ASAF-MODULE-106 [Shenzhen Eybond Co., Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, Mencius meng Shenzhen Eybond Co., Ltd January 8, 2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2ASAF-MODULE-106 [Shenzhen Eybond Co., Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Mencius meng
Shenzhen Eybond Co., Ltd Difference Description We Shenzhen Eybond Co., Ltd state: Product name: Module Model(s): WFMesh.Gateway.Module-106, WFMesh.Gateway.Module-206, WFMesh.Gateway.Module-306, WFMesh.Node.Module-106, WFMesh.Node.Module-206,WFMesh.Node.Module-306 All the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type(s) and antenna location, components on PCB, etc.,), same mechanical structure and design (including product enclosure, materials, etc.,), the only difference is the model name. Signature: January 8, 2026 Name: Mencius meng Position: Director of R & D Company Name: Shenzhen Eybond Co., Ltd Address: Building 10, Zhiheng Science &Technology Park, Nantou Street, Nanshan District, Shenzhen City, Guangdong Province, China. Tel: 0755-89992588 Fax: 0755-89992588 Email: [email protected]
Shenzhen Eybond Co., Ltd 1/8/2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR Product Name: Module FCC ID: 2ASAF-MODULE-106 Model(s): WFMesh.Gateway.Module-106 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (Schematic Diagram, Block Diagram, Operational Description) required to be submitted with this application be permanently withheld from public review. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market Please contact me if there is any information you may need. Sincerely, Signature: January 8, 2026 Name Mencius meng Position Director of R & D Company Name Shenzhen Eybond Co., Ltd Address Building 10, Zhiheng Science &Technology Park, Nantou Street, Nanshan District, Shenzhen City, Guangdong Province, China. Tel 0755-89992588 Fax 0755-89992588 Email [email protected]
Shenzhen Eybond Co., Ltd 1/8/2026 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen PSI Testing Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This agreement expires one year from the current date. Sincerely, Signature: January 8, 2026 Name Mencius meng Position Director of R & D Company Name Shenzhen Eybond Co., Ltd Address Building 10, Zhiheng Science &Technology Park, Nantou Street, Nanshan District, Shenzhen City, Guangdong Province, China. Tel 0755-89992588 Fax 0755-89992588 Email [email protected]
Shenzhen Eybond Co., Ltd Federal Communications Commission Equipment Authorization Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: January 8, 2026 Subject; Modular Transmitter Application Company name: Shenzhen Eybond Co., Ltd FCC ID: 2ASAF-MODULE-106 Dear Sir/Madam, This letter includes the FCC application requirements for Modular Transmitter Approval Request for;- FCC KDB 996369 D01 ‘Module Certification Guide v04r02; and FCC KDB 996369 D03 OEM Manual v01r01 In accordance with 47CFR 15.212 Modular Transmitters and KDB 996369 D01 ‘Module Equip Auth Guide v02’. FCC ID 2ASAF-MODULE-106 has been examined against the following requirements. Requirement per 15.212 and KDB 996369 D01 Explanation from Grantee (do not write yes/no, but explain why product complies/how it is achieved) The radio elements must have the radio frequency circuitry shielded. Physical components and tuning capacitor(s) may be located external to the shield, but must be on the module assembly. Yes, the radio frequency circuitry shielded The module must have buffered modulation/data inputs to ensure that the device will comply with Part 15 requirements with any type of input signal. Yes, The module comply with Part 15 requirements The module must contain power supply regulation on the module. Yes, The module contain power supply regulation The module must contain a permanently attached antenna, or contain a unique antenna connector, and be marketed and operated only with specific antenna(s), per §§ 15.203, 15.204(b), 15.204(c), 15.212(a), 2.929(b). Yes, The module contain a permanently attached antenna, and be marketed and operated only with specific antenna(s), per Sections 15.203, 15.204(b), 15.204(c), 15.212(a), 2.929(b) The module must demonstrate compliance in a stand-alone configuration. Yes, the module compliance in a standalone configuration The module must be labeled with its permanently affixed FCC ID label, or use an electronic display (see KDB Publication 784748). Yes, The module labelled with its permanently affixed FCC ID label The module must comply with all specific rules applicable to the transmitter, including all the conditions provided in the integration instructions by the grantee. Yes, The module comply with all specific rules applicable to the transmitter including all the conditions provided in the integration instructions by the grantee Shenzhen Eybond Co., Ltd The module must comply with RF exposure requirements Yes, The module comply with RF exposure requirements Integration Instructions for host product manufacturers The following items are submitted in support of application for Modular Transmitter FCC ID as noted above as required by the FCC KDB 996369 D03 OEM Manual v01r01. These items are provided as integration instructions for host product manufacturers (e.g., OEM instruction manual) to use when integrating a module in a host product. Any requirements that are not applicable to the Module are as indicated below. Summary of requirements and Checklist. Refer to the KDB for description of the complete requirements; KDB Ref Sect Requirements of KDB 996369 D03 User Manual Page Number reference 2.2 List of applicable FCC rules Page 11 2.3 Summarize the specific operational use conditions Page 11 2.4 Limited module procedures Page 11 2.5 Trace antenna designs Page 11 2.6 RF exposure considerations Page 11 2.7 Antennas Page 12 2.8 Label and compliance information Page 12 2.9 Information on test modes and additional testing requirements Page 12 2.10 Additional testing, Part 15 Subpart B disclaimer Page 12 2.11 Note EMI Considerations Page 12 2.12 How to make changes Page 12 Name: Mencius meng Date: January 8, 2026 Title: Director of R & D Signature of applicant
Page 1 of 4 Report No.: psi2512150-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix II external photos FCC ID: 2ASAF-MODULE-106 Page 2 of 4 Report No.: psi2512150-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China BT and WiFi ANT Page 3 of 4 Report No.: psi2512150-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 4 of 4 Report No.: psi2512150-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China ------End------
Label and Location Material: Silk-screen Font color: White Size: L: 0.8cm*W: 0.2cm Label and Location W FCC ID: 2ASAF-MODULE-106 Model No.: WFMesh.Gateway.Module-106 L
Page 1 of 1 Report No.: psi2512150-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix III internal photos FCC ID: 2ASAF-MODULE-106 ------End------
Page 1 of 2 Report No.: psi2512150-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix IV MPE FCC ID: 2ASAF-MODULE-106 Prediction of MPE at a given distance 1. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) KDB Test Methodology: KDB 447498 D01 v06. 2. Test Procedure Equation from page 18 of OET Bulletin 65, Edition 97-01 Where: S = power density P = power input to the antenna G = numeric gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the centre of radiation of the antenna Page 2 of 2 Report No.: psi2512150-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China 3. Result Mode Frequency (MHz) Prediction distance (cm) RF output power(Max) (dBm) Tune-up power (Max) MPE (mW/cm 2 ) Limit (mW/cm 2 ) SAR Test Exclusion dBm mW BT LE 2402-2480 20 4.55 5 2.8510 0.0009 1 Yes 2.4G WiFi 2412-2462 20 15.39 5 34.5939 0.0111 1 Yes BT Antenna: max gain 2.06dBi, 1.61(numeric) 2.4G WiFi Antenna: max gain 2.06dBi, 1.61(numeric) Therefore this device complies with FCC's RF radiation exposure limits for general population without SAR evaluation.
深圳市升业科技有限公司 Shenzhen Shengye Technology Co., Ltd. 测 试 报 告 Test Report 客户名称 益邦阳光 项目名称 内置PCB-WIFI 射频工程师 王顺 电话 13480129802 结构工程师 张世斌 电话 15994751382 日期 2023.09.12 邮箱 1. OTA数据 OTA data: 2.天线图片: A ntenna Picture 3.驻波图: Standing Wave Diagram 4.增益效率: Gain Efficiency Frequency/MhzEfficiency / %MaxGain/dBi 240061.942.36 241060.391.95 242058.612.06 243054.21.35 244057.941.83 245054.71.38 246051.641.11 247047.970.9 248044.980.48 5.方 向图: d irectional diagram
Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Page 1 of 55 Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China FCC TEST REPORT FCC ID: 2ASAF-MODULE-106 On Behalf of Shenzhen Eybond Co., Ltd Module Model No.: WFMesh.Gateway.Module-106, WFMesh.Gateway.Module-206, WFMesh.Gateway.Module-306, WFMesh.Node.Module-106, WFMesh.Node.Module-206,WFMesh.Node.Module-306 Prepared for : Shenzhen Eybond Co., Ltd Address : Building 10, Zhiheng Science &Technology Park, Nantou Street, Nanshan District, Shenzhen City, Guangdong Province, China. Prepared By : Shenzhen PSI Testing Co., Ltd. Address : 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Report Number : psi2512150-C01-R01 Date of Receipt : December 16, 2025 Date of Test : December 17, 2025-December 30, 2025 Date of Report : December 31, 2025 Version Number : V0 Page 2 of 55 Report No.: psi2512150-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China TABLE OF CONTENTS Description Page 1. Summary Of Standards And Results ------------------------------------------------------------- 6 1.1. Description of Standards and Results ------------------------------------------------------- 6 2. General Information ------------------------------------------------------------------------------------ 7 2.1. Description of Device (EUT) ------------------------------------------------------------------- 7 2.2. Accessories of Device (EUT) ------------------------------------------------------------------ 8 2.3. Tested Supporting System Details------------------------------------------------------------ 8 2.4. Block Diagram of Connection Between EUT and Simulators ------------------------- 8 2.5. Test Mode Description --------------------------------------------------------------------------- 9 2.6. Software test version and power setting information ------------------------------------ 9 2.7. Test Conditions ---------------------------------------------------------------------------------- 10 2.8. Test Facility --------------------------------------------------------------------------------------- 10 2.9. Measurement Uncertainty -------------------------------------------------------------------- 10 2.10. Test Equipment List----------------------------------------------------------------------------- 11 3. Spurious Emission ------------------------------------------------------------------------------------ 12 3.1. Test Limits ----------------------------------------------------------------------------------------- 12 3.2. Block Diagram of Test setup ----------------------------------------------------------------- 13 3.3. Test Procedure ----------------------------------------------------------------------------------- 14 3.4. Test Results--------------------------------------------------------------------------------------- 15 4. Power Line Conducted Emission ---------------------------------------------------------------- 21 4.1. Test Limits ----------------------------------------------------------------------------------------- 21 4.2. Test Procedure ----------------------------------------------------------------------------------- 21 4.3. Test Setup ----------------------------------------------------------------------------------------- 21 4.4. Test Results--------------------------------------------------------------------------------------- 22 5. Out-of-band Emissions ------------------------------------------------------------------------------ 25 5.1. Test Limits ----------------------------------------------------------------------------------------- 25 5.2. Test Procedure ----------------------------------------------------------------------------------- 25 5.3. Test Setup ----------------------------------------------------------------------------------------- 25 5.4. Test Results--------------------------------------------------------------------------------------- 25 6. Conducted Maximum Output Power ------------------------------------------------------------ 36 6.1. Test limits ------------------------------------------------------------------------------------------ 36 6.2. Test Procedure ----------------------------------------------------------------------------------- 36 6.3. Test Setup ----------------------------------------------------------------------------------------- 36 6.4. Test Results--------------------------------------------------------------------------------------- 36 7. Peak Power Spectral Density --------------------------------------------------------------------- 40 7.1. Test limits ------------------------------------------------------------------------------------------ 40 7.2. Test Procedure ----------------------------------------------------------------------------------- 40 7.3. Test Setup ----------------------------------------------------------------------------------------- 40 7.4. Test Results--------------------------------------------------------------------------------------- 40 8. Occupied Bandwidth --------------------------------------------------------------------------------- 44 8.1. Test limits ------------------------------------------------------------------------------------------ 44 8.2. Test Procedure ----------------------------------------------------------------------------------- 44 8.3. Test Setup ----------------------------------------------------------------------------------------- 44 8.4. Test Results--------------------------------------------------------------------------------------- 44 Page 3 of 55 Report No.: psi2512150-C01-R01 Shenzhen PSI Testing Co., Ltd. Tel: 07…
Text truncated - open the document above for the full version.
Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Page 1 of 111 Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China FCC TEST REPORT FCC ID: 2ASAF-MODULE-106 On Behalf of Shenzhen Eybond Co., Ltd Module Model No.: WFMesh.Gateway.Module-106, WFMesh.Gateway.Module-206, WFMesh.Gateway.Module-306, WFMesh.Node.Module-106, WFMesh.Node.Module-206,WFMesh.Node.Module-306 Prepared for : Shenzhen Eybond Co., Ltd Address : Building 10, Zhiheng Science &Technology Park, Nantou Street, Nanshan District, Shenzhen City, Guangdong Province, China. Prepared By : Shenzhen PSI Testing Co., Ltd. Address : 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Report Number : psi2512150-C01-R02 Date of Receipt : December 16, 2025 Date of Test : December 17, 2025-December 30, 2025 Date of Report : December 31, 2025 Version Number : V0 Page 2 of 111 Report No.: psi2512150-C01-R02 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China TABLE OF CONTENTS Description Page 1. Summary Of Standards And Results ------------------------------------------------------------- 6 1.1. Description of Standards and Results -------------------------------- ----------------------- 6 2. General Information ------------------------------------------------------------------------------------ 7 2.1. Description of Device (EUT) ---------------------------------------------------------------- --- 7 2.2. Accessories of Device (EUT) ---------------------------------------------------------------- -- 8 2.3. Tested Supporting System Details -------------------------------- ---------------------------- 8 2.4. Block Diagram of Connection Between EUT and Simulators ------------------------- 8 2.5. Test Mode Description --------------------------------------------------------------------------- 9 2.6. Software test version and power setting information ---------------------------------- 20 2.7. Test Conditions ---------------------------------------------------------------------------------- 20 2.8. Test Facility --------------------------------------------------------------------------------------- 21 2.9. Measurement Uncertainty -------------------------------------------------------------------- 21 2.10. Test Equipment List----------------------------------------------------------------------------- 22 3. Spurious Emission ------------------------------------------------------------------------------------ 23 3.1. Test Limits ----------------------------------------------------------------------------------------- 23 3.2. Block Diagram of Test setup ----------------------------------------------------------------- 24 3.3. Test Procedure ----------------------------------------------------------------------------------- 25 3.4. Test Results--------------------------------------------------------------------------------------- 26 4. Power Line Conducted Emission ---------------------------------------------------------------- 34 4.1. Test Limits ----------------------------------------------------------------------------------------- 34 4.2. Test Procedure ----------------------------------------------------------------------------------- 34 4.3. Test Setup ----------------------------------------------------------------------------------------- 34 4.4. Test Results--------------------------------------------------------------------------------------- 35 5. Out-of-band Emissions ------------------------------------------------------------------------------ 38 5.1. Test Limits ----------------------------------------------------------------------------------------- 38 5.2. Test Procedure ----------------------------------------------------------------------------------- 38 5.3. Test Setup ----------------------------------------------------------------------------------------- 38 5.4. Test Results--------------------------------------------------------------------------------------- 38 6. Conducted Maximum Output Power ------------------------------------------------------------ 71 6.1. Test limits ------------------------------------------------------------------------------------------ 71 6…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 34.59 mW |
| 2 | 15C | 2.40 GHz - 2.48 GHz | 2.85 mW |

Module
Equipment Class
DTS - Digital Transmission System
Datalogger
Equipment Class
DTS - Digital Transmission System
Datalogger
Equipment Class
DTS - Digital Transmission System
WFBLE.Module
Equipment Class
DTS - Digital Transmission System
Wi-Fi Plug Pro
Equipment Class
DTS - Digital Transmission System