Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jan 30, 2025
Application Purpose
Original Equipment
Equipment Note
Automotive OBD2 Scanner Diagnostic Tool
Frequency Range
2402.00000000 - 2480.00000000
Company
OBDSPACE TECHNOLOGY CO,.LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

i IMPORTANT Trademarks ANCEL ® istrademarkofANCELTECHNOLOGYCO.,LTD.(hereinafterreferredtoas “ANCEL”),registeredinChina,theUnitedStates,andothercountries. CopyrightInformation Nopartofthismanualmaybereproduced,storedinaretrievalsystemortransmittedin anyformorbyanymeanselectronic,mechanical,photocopying,recording,or otherwisewithoutthepriorwrittenpermissionofANCEL. DisclaimerofWarrantiesandLimitationofLiabilities Allinformation,specificationsandillustrationsinthismanualarebasedonthelatest informationavailableatthetimeofprinting. ANCELreservestherighttomakechangesatanytimewithoutnotice.While informationofthismanualhasbeencarefullycheckedforaccuracy,noguaranteeis givenforthecompletenessandcorrectnessofthecontents,includingbutnotlimitedto theproductspecifications,functions,andillustrations. ANCELwillnotbeliableforanydirect,special,incidental,orindirectdamages,orfor anyeconomicconsequentialdamages(includingthelossofprofits)becauseofusing thisproduct. Beforeoperatingormaintainingthisunit,pleasereadthismanualcarefully,paying extraattentiontothesafetywarningsandprecautions. ForServicesandSupport www.anceltech.com [email protected] ii DANGER WARNING SafetyInformation Foryourownsafetyandthesafetyofothers,andtopreventdamagetothedeviceand vehiclesuponwhichitisused,itisimportantthatthesafetyinstructionspresented throughoutthismanualbereadandunderstoodbyallpersonsoperatingor encounteringthedevice. Therearevariousprocedures,techniques,tools,andpartsrequiredforservicing vehicles,aswellastheskillsofthepersondoingthework.Becauseofthevastnumber oftestapplicationsandvariationsintheproductsthatcanbetestedwiththisequipment, wecannotpossiblyanticipateorprovideadviceorsafetymessagestocoverevery circumstance.Itistheautomotivetechnician’sresponsibilitytobeknowledgeableofthe systembeingtested.Itiscrucialtouseproperservicemethodsandtestprocedures.It isessentialtoperformtestsinanappropriateandacceptablemannerthatdoesnot endangeryoursafety,thesafetyofothersintheworkarea,thedevicebeingused,or thevehiclebeingtested. Beforeusingthedevice,alwaysrefertoandfollowthesafetymessagesandapplicable testproceduresprovidedbythemanufacturerofthevehicleorequipmentbeingtested. Usethedeviceonlyasdescribedinthismanual.Besuretoread,understand,and followallsafetymessagesandinstructionsinthismanual. SafetyMessages Safetymessagesareprovidedtohelppreventpersonalinjuryandequipmentdamage. Allsafetymessagesareintroducedbyasignalwordindicatingthehazardlevel. Indicatesanimminentlyhazardoussituationwhich,ifnotavoided,willresultindeathor seriousinjurytotheoperatorortobystanders. Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,couldresultindeathor seriousinjurytotheoperatorortobystanders. SafetyInstructions ThesafetymessageshereincoversituationsANCELisawareofatthetimeof publication.ANCELcannotknow,evaluateoradviseyouastoallofthepossible hazards.Youmustbecertainthatanyconditionorserviceprocedureencountered doesnotjeopardizeyourpersonalsafety. iii DANGER Whenanengineisoperating,keeptheserviceareaWELLVENTILATEDorattacha buildingexhaustremovalsystemtotheengineexhaustsystem.Enginesproduce carbonmonoxide,anodorless,poisonousgasthatcausesslowerreactiontimeand canleadtoseriouspersonalinjuryorlossoflife. SAFETYWARNINGS  Alwaysperformautomotivetestinginasafeenvironment.  WearsafetyeyeprotectionthatmeetsANSIstandards.  Keepclothing,hair,hands,tools,testequipment,etc.awayfromallmovingorhot engineparts.  Operatethevehicleinawell-ventilatedworkarea,forexhaustgasesare poisonous.  PutthetransmissioninPARK(forautomatictransmission)orNEUTRAL(for manualtransmission)andmakesuretheparkingbrakeisengaged.  Putblocksinfrontofthedrivewheelsandneverleavethevehicleunattended whiletesting. Beextracautiouswhenworkingaroundtheignitioncoil,distributorcap,ignition wiresandsparkplugs.Thesecomponentscreatehazardousvoltageswhenthe engineisrunning. Keepafireextinguishersuitableforgasoline,chemical,andelectricalfiresnearby.  Donotconnectordisconnectanytestequipmentwhiletheignitionisonorthe engineisrunning. Keepthetestequipmentdry,clean,freefromoil,waterorgrease.Useamild detergentonacleanclothtocleantheoutsideoftheequipmentasnecessary.  Donotdrivethevehicleandoperatethetestequipmentatthesametime.Any distractionmaycauseanaccident.  Refertotheservicemanualforthevehiclebeingservicedandadheretoall diagnosticproceduresandprecautions.Failuretodosomayresultinpersonal injuryordamagetothetestequipment. Toavoiddamagingthetestequipmentorgeneratingfalsedata,makesurethe vehiclebatteryisfullychargedandtheconnectiontothevehicleDLCiscleanand secure. Donotplacethetestequipmentonthedistributorofthevehicle.Strong electro-magneticinterferencecandamagetheequipment. iv CONTENTS Trademarks................................................................................................1 CopyrightInformation..............................................................................1 DisclaimerofWarrantiesandLimitationofLiabilities.........................1 ForServicesandSupport........................................................................1 SafetyInformation....................................................................................2 SafetyMessages.......................................................................................2 SafetyInstructions....................................................................................2 1UsingThisManual...............................................................................................................1 1.1Conventions...........................................................................................................1 1.1.1BoldText........................................................................................1 1.1.2NotesandImportantMessages...................................................1 1.1.3Hyperlink........................................................................................1 1.1.4Illustrations................................................................................…

Text truncated - open the document above for the full version.

Attestation Statements

OBDSPACE TECHNOLOGY CO,.LTD U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name: Baihetian Innovative Solutions FRN: 0033401605 Contact Name: Kenneth Young Street Address: 6837 Chase Rd City/Province/Zip: Dearborn, MI 48126 Telephone No: 313-395-3113 Email: [email protected] This letter is to confirm that we (Baihetian Innovative Solutions) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature: Date: Jan. 21, 2025 Signed by (Printed Name/Title): Kenneth Young/Manager The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: Shenzhen Forwell Electronics Technology Co., Ltd. Grantee Code: 2ASC7 FCC ID: 2ASC7-X6 FRN: 0028167070 Contact Name: Frank Hao Street Address: Room D03, Building A, No.973, MinZhi Avenue LongHua district, Shenzhen City, China Telephone No: +86-13691649917 Email: [email protected] Applicant Signature: Date: 2025.01.21 Signed by (Printed Name/Title): Frank Hao / Manager

Attestation Statements

OBDSPACE TECHNOLOGY CO,.LTD Address: Room D03, Building A, No.973, MinZhi Avenue LongHua district, Shenzhen City, China Date: 2025-01-21 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing SUBJECT: FCC Application for FCC ID: 2ASC7-X6 To Whom It May Concern: OBDSPACE TECHNOLOGY CO,.LTD certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Signature: Date: 2025-01-21

Attestation Statements

OBDSPACE TECHNOLOGY CO,.LTD Address: Room D03, Building A, No.973, MinZhi Avenue LongHua district, Shenzhen City, China Date: 2025-01-21 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing SUBJECT: FCC Application for FCC ID: 2ASC7-X6 To Whom It May Concern: OBDSPACE TECHNOLOGY CO,.LTD certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature: Date: 2025-01-21

Cover Letter(s)

Project: RUNZHUOWULIANTD702 Author:LiKai FileName: RUNZHUOWULIANTD702-APP- RA Date:2024-06-05 Rev:Language:Check: AENG CONFIDENTIAL ShenZhenEastongElectronictechnologyCo.,LTD Page -1- ShenZhenEastongElectronictechnologyCo.,LTD APPROVALSHEET FOR RUNZHUOWULIANTD702 (WIFIbandinternalantenna) IssuedbyCheckedby ConfirmedbyDate2024-06-05 Customer Confirm Project: RUNZHUOWULIANTD702 Author:LiKai FileName: RUNZHUOWULIANTD702-APP- RA Date:2024-06-05 Rev:Language:Check: AENG CONFIDENTIAL ShenZhenEastongElectronictechnologyCo.,LTD Page -2- RevisionHistory DateRevisionDescriptionofChanges 2024-06-05R:AAntennaperformanceapprovedbycustomer 1SUMMARY 2GENERALDESCRIPTION 2.1Definitions 3MECHANICALDESCRIPTION 4ELECTRICALPERFORMANCE 4.1Set-up 4.1.1VSWRandreturnloss 4.1.2Efficiency,GainandTRP/TIS 4.1.3MatchingCircuitDescription 4.2MeasurementData 4.2.1VSWR 4.2.2Activeresult 5MECHANICALDRAWING 6CONCLUSION Project: RUNZHUOWULIANTD702 Author:LiKai FileName: RUNZHUOWULIANTD702-APP- RA Date:2024-06-05 Rev:Language:Check: AENG CONFIDENTIAL ShenZhenEastongElectronictechnologyCo.,LTD Page -3- 1Summary Thisreportsummarizestheelectricalresultsoftheproposedantennatosupportthe TD702program.Wetesttheantennawiththelatestversionhandset. 2GeneralDescription 2.1Definitions VSWR:VoltageStandingWaveRate 3MechanicalDescription 4ElectricalPerformance 4.1Set-up 4.1.1VSWRandreturnloss VSWRmeasurements(S 11 )wereperformedusinganAgilentE5070BNetwork Analyzerandthepreviouslydescribedtestfixture.Coaxialchokeswereusedto mitigatesurfacecurrentsontheoutsideofthecabling.Thetestingwasperformedin freespace. 4.1.2Efficiency,GainandTRP/TIS ThegainoftheantennawasmeasuredinDongXin’s3Danechoicchamberin Shenzhen.Thechamberiscapableofdoingtestsfrom380MHzto6GHz.Coaxial chokesonthefeedcablewereusedtomitigatesurfacecurrents.Themeasurement resultsarecalibratedusingdipolestandards.ForTRPandTISthechamberusesa Agilent8960toestablishtheconnectionwiththemobiledevice.DuringTRPteststhe 8960readsthepowerreceivedthroughthechamberprobeswhilstduringTISteststhe 8960transmitsthroughtheprobe.Alldataisafterwardscorrectedbyacalibration table. 4.1.3MatchingCircuitDescription Nomatching. 4.2MeasurementData EffectiveRadiatedPowerSummation 5Mechanicaldrawing Project: RUNZHUOWULIANTD702 Author:LiKai FileName: RUNZHUOWULIANTD702-APP- RA Date:2024-06-05 Rev:Language:Check: AENG CONFIDENTIAL ShenZhenEastongElectronictechnologyCo.,LTD Page -4- Address:409-411,ShanhaiE- commercePort,No.9HuanchengRoad,YangmeiCommunity,Ba ntianStreet,LonggangDistrict,Shenzhen Project: RUNZHUOWULIANTD702 Author:LiKai FileName: RUNZHUOWULIANTD702-APP- RA Date:2024-06-05 Rev:Language:Check: AENG CONFIDENTIAL ShenZhenEastongElectronictechnologyCo.,LTD Page -5- Antennatype:PIFA Antennagain: Freq(MHz)Effi(%)Gain(dBi) 240036.451.64 241036.981.57 242037.591.89 243037.691.76 244038.761.82 245038.981.73 246037.531.76 247037.681.68 248037.211.63 249036.431.57 250035.231.54 515028.861.22 535029.371.28 555031.561.33 575032.421.25 585030.651.13 Project: RUNZHUOWULIANTD702 Author:LiKai FileName: RUNZHUOWULIANTD702-APP- RA Date:2024-06-05 Rev:Language:Check: AENG CONFIDENTIAL ShenZhenEastongElectronictechnologyCo.,LTD Page -6-

Cover Letter(s)

Effective Date: April 2, 2020 QSF 7.6.4-8 – Agent Authorization Letter Template Page 1 of 1 Revision Date: Revision: 0 OBDSPACE TECHNOLOGY CO,.LTD Room D03, Building A, No.973, MinZhi Avenue LongHua district, Shenzhen City, China Date:2025/01/21 Product Model Number: X6 FCC ID:2ASC7-X6 To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following:  Testing  Approval applications and procedures We declare that OBDSPACE TECHNOLOGY CO,.LTD is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by OBDSPACE TECHNOLOGY CO,.LTD on our behalf shall have the same effect as acts of our own. By: Contact Listed on FCC Wesbite Title: Manager Email: [email protected] Telephone: +86-13691649917 On behalf of: OBDSPACE TECHNOLOGY CO,.LTD

Cover Letter(s)

OBDSPACE TECHNOLOGY CO,.LTD Room D03, Building A, No.973, MinZhi Avenue LongHua district, Shenzhen City, China Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: January 21, 2025 Subject; Request for Confidentiality FCC ID: 2ASC7-X6 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure Software Security Requirements for UNII devices In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Frank Hao Title: Manager

Cover Letter(s)

OBDSPACE TECHNOLOGY CO,.LTD Room D03, Building A, No.973, MinZhi Avenue LongHua district, Shenzhen City, China Series Models Description To whom it may concern: The device (Product Name: Automotive OBD2 Scanner Diagnostic Tool) Models Name: X6, X6HD, X6PLUS, X6PRO, X6ELITE, V6, V6HD, V6PLUS, V6PRO, V6ELITE, V3, V3HD, V3PLUS, V3PRO, V3ELITE have same electrical, PCB and BOM, only the model’s name and colour are different for marketing requirements. Sincerely, Frank Hao Phone: +86-13691649917 e-mail: [email protected] Dated: 2025.01.21

External Photos

FCC ID: 2ASC7-X6 Page 1 of 5 Report No.: CTL2412032623-WF External Photos of EUT FCC ID: 2ASC7-X6 Page 2 of 5 Report No.: CTL2412032623-WF FCC ID: 2ASC7-X6 Page 3 of 5 Report No.: CTL2412032623-WF FCC ID: 2ASC7-X6 Page 4 of 5 Report No.: CTL2412032623-WF FCC ID: 2ASC7-X6 Page 5 of 5 Report No.: CTL2412032623-WF

ID Label/Location Info

FCC ID: 2ASC7-X6 Page 1 of 1 Report No.: CTL2412032623-WF FCC ID Label Information 1. Label location: Size: L2.0cm*W1.0cm Automotive OBD2 Scanner Diagnostic Tool Model: X6 FCC ID: 2ASC7-X6 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

FCC ID: 2ASC7-X6 Page 1 of 4 Report No.: CTL2412032623-WF Internal Photos of EUT Bluetooth & WIFI Antenna FCC ID: 2ASC7-X6 Page 2 of 4 Report No.: CTL2412032623-WF FCC ID: 2ASC7-X6 Page 3 of 4 Report No.: CTL2412032623-WF FCC ID: 2ASC7-X6 Page 4 of 4 Report No.: CTL2412032623-WF

RF Exposure Info

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China TEST REPORT Report Reference No. .................... : FCC ID. .......................................... : CTA24121001001 2ASC7-X6 Compiled by ( position+printed name+signature) .. : File administrators Jinghua Xiao Supervised by ( position+printed name+signature) .. : Project Engineer Lushan Kong Approved by ( position+printed name+signature) .. : RF Manager Eric Wang Date of issue ..................................... : Dec. 19, 2024 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................. : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ............................ : OBDSPACE TECHNOLOGY CO,.LTD Address ............................................. : Room D03, Building A, No.973, MinZhi Avenue LongHua district, Shenzhen City, China Test specification ........................... : Standard ........................................... : FCC 47CFR §2.1093; ANSI/IEEE C95.1-2019; IEEE 1528-2013; KDB 248227 D01; KDB 616217 D04; KDB 447498 D01; KDB 865664 D01; KDB 865664 D02; KDB 690783 D01;KDB 941225 D06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Automotive OBD2 Scanner Diagnostic Tool Trade Mark........................................ : ANCEL Manufacturer ..................................... : OBDSPACE TECHNOLOGY CO,.LTD Model/Type reference ....................... : X6 Listed Models .................................. : X6HD X6PLUS X6PRO X6ELITE V6 V6HD V6PLUS V6PRO V6ELITE V3 V3HD V3PLUS V3PRO V3ELITE Rating ............................................... : DC 3.85V From battery Result ................................................ : PASS Report No.: CTA24121001001 Page 2 of 85 T E S T R E P O R T Equipment under Test : Automotive OBD2 Scanner Diagnostic Tool Model /Type : X6 Listed Models : X6HD X6PLUS X6PRO X6ELITE V6 V6HD V6PLUS V6PRO V6ELITE V3 V3HD V3PLUS V3PRO V3ELITE Applicant : OBDSPACE TECHNOLOGY CO,.LTD Address : Room D03, Building A, No.973, MinZhi Avenue LongHua district, Shenzhen City, China Manufacturer : OBDSPACE TECHNOLOGY CO,.LTD Address : Room D03, Building A, No.973, MinZhi Avenue LongHua district, Shenzhen City, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA24121001001 Page 3 of 85 ※ ※ Revision History ※ ※ REV. ISSUED DATE DESCRIPTION Rev.1.0 Dec. 19, 2024 Initial Test Report Release Report No.: CTA24121001001 Page 4 of 85 Contents 1 Statement of Compliance ............................................................................................... 6 2 General Information ........................................................................................................ 7 General Remarks ............................................................................................................................................. 7 Description of Equipment Under Test (EUT) ..................................................................................................... 7 Device Category and SAR Limits ..................................................................................................................... 9 Applied Standard .............................................................................................................................................. 9 Test Facility ..................................................................................................................................................... 10 Environment of Test Site .................................................................................................................................. 11 Test Configuration ............................................................................................................................................ 11 3 Specific Absorption Rate (SAR) ................................................................................... 12 Introduction ..................................................................................................................................................... 12 SAR Definition ................................................................................................................................................ 12 4 SAR Measurement System .......................................................................................... 13 E-Field Probe .................................................................................................................................................. 13 Data Acquisition Electronics (DAE) ................................................................................................................. 14 Robot .............................................................................................................................................................. 15 Measurement Server ...................................................................................................................................... 15 Phantom ......................................................................................................................................................... 16 Devic…

Text truncated - open the document above for the full version.

RF Exposure Info

Report No.: CTA24121001001 Page 61 of 85 Report No.: CTA24121001001 Page 62 of 85 Report No.: CTA24121001001 Page 63 of 85 Report No.: CTA24121001001 Page 64 of 85 Report No.: CTA24121001001 Page 65 of 85 Report No.: CTA24121001001 Page 66 of 85 Report No.: CTA24121001001 Page 67 of 85 Report No.: CTA24121001001 Page 68 of 85 Report No.: CTA24121001001 Page 69 of 85 Report No.: CTA24121001001 Page 70 of 85 Report No.: CTA24121001001 Page 71 of 85 Report No.: CTA24121001001 Page 72 of 85 Report No.: CTA24121001001 Page 73 of 85 Report No.: CTA24121001001 Page 74 of 85 Report No.: CTA24121001001 Page 75 of 85 Report No.: CTA24121001001 Page 76 of 85 Report No.: CTA24121001001 Page 77 of 85 Report No.: CTA24121001001 Page 78 of 85 Report No.: CTA24121001001 Page 79 of 85 Report No.: CTA24121001001 Page 80 of 85 Report No.: CTA24121001001 Page 81 of 85 Report No.: CTA24121001001 Page 82 of 85 Report No.: CTA24121001001 Page 83 of 85 Report No.: CTA24121001001 Page 84 of 85 Report No.: CTA24121001001 Page 85 of 85 Referring to KDB 865664D01V01r03, if dipoles are verified in return loss (<-20dB, within 20% of prior calibration) and in impedance (within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. D2450V2, SN. 745 2450 Head Date of. Measurement Return-Loss (dB) Delta (%) Real Impedance (ohm) Delta (ohm) 2023-08-28 -23.7 54.2 2024-08-27 -23.68 -0.08 54.1 -0.1 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. *****END OF REPORT*****

Test Report

Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 E-mail: [email protected] TEST REPORT FCC PART 15.247 Report Reference No.: CTL2412032623-WF01 Compiled by: ( position+printed name+signature) Happy Guo (File administrators) Tested by: ( position+printed name+signature) Jack Wang (Test Engineer) Approved by: ( position+printed name+signature) Ivan Xie (Manager) Product Name ............................ : Automotive OBD2 Scanner Diagnostic Tool Model/Type reference ................ : X6 List Model(s) ............................... : X6HD, X6PLUS, X6PRO, X6ELITE, V6, V6HD, V6PLUS, V6PRO, V6ELITE, V3, V3HD, V3PLUS, V3PRO, V3ELITE Trade Mark .................................. : ANCEL FCC ID ......................................... : 2ASC7-X6 Applicant’s name ....................... : OBDSPACE TECHNOLOGY CO,.LTD Address of applicant ................. : Room D03, Building A, No.973, MinZhi Avenue LongHua district, Shenzhen City, China Test Firm ..................................... : Shenzhen CTL Testing Technology Co., Ltd. Address of Test Firm ................. : Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road, Nanshan District, Shenzhen, China 518055 Test specification ....................... : Standard ...................................... : FCC Part 15.247: Operation within the bands 902-928 MHz, 2400-2483.5 MHz and 5725-5850 MHz. TRF Originator ............................. : Shenzhen CTL Testing Technology Co., Ltd. Master TRF .................................. : Dated 2011-01 Date of receipt of test item ........ : Dec. 05, 2024 Date of Test Date ........................ : Dec. 05, 2024-Dec. 16, 2024 Date of Issue .............................. : Dec. 17, 2024 Result .......................................... : Pass Shenzhen CTL Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. V1.0 Page 2 of 42 Report No.: CTL2412032623-WF01 TEST REPORT Test Report No. : CTL2412032623-WF01 Dec. 17, 2024 Date of issue Equipment under Test : Automotive OBD2 Scanner Diagnostic Tool Sample No : CTL2412032623 Model /Type : X6 Listed Models : X6HD, X6PLUS, X6PRO, X6ELITE, V6, V6HD, V6PLUS, V6PRO, V6ELITE, V3, V3HD, V3PLUS, V3PRO, V3ELITE Applicant : OBDSPACE TECHNOLOGY CO,.LTD Address : Room D03, Building A, No.973, MinZhi Avenue LongHua district, Shenzhen City, China Manufacturer : OBDSPACE TECHNOLOGY CO,.LTD Address : Room D03, Building A, No.973, MinZhi Avenue LongHua district, Shenzhen City, China Test result Pass * *In the configuration tested, the EUT complied with the standards specified page 5. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. The device (Product Name: Automotive OBD2 Scanner Diagnostic Tool ) Models Name: X6, X6HD, X6PLUS, X6PRO, X6ELITE, V6, V6HD, V6PLUS, V6PRO, V6ELITE, V3, V3HD, V3PLUS, V3PRO, V3ELITE have same electrical, PCB and BOM, only the colour and model’ s names are different for marketing requirements. V1.0 Page 3 of 42 Report No.: CTL2412032623-WF01 ** Modified History ** Revisions Description Issued Data Report No. Remark Version 1.0 Initial Test Report Release 2024-12-17 CTL2412032623-WF01 Tracy Qi V1.0 Page 4 of 42 Report No.: CTL2412032623-WF01 Table of Contents Page 1. SUMMARY ............................................................................................................................................................... 5 1.1. TEST STANDARDS ..................................................................................................................................................... 5 1.2. TEST DESCRIPTION ........................................................................................................................................................ 5 1.3. TEST FACILITY .............................................................................................................................................................. 6 1.4. STATEMENT OF THE MEASUREMENT UNCERTAINTY ............................................................................................................... 6 2. GENERAL INFORMATION .......................................................................................................................................... 8 2.1. ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 8 2.2. GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 8 2.3. DESCRIPTION OF TEST MODES AND TEST FREQUENCY .......................................................................................................... 9 2.4. EQUIPMENTS USED DURING THE TEST ............................................................................................................................ 10 2.5. RELATED SUBMITTAL(S) / GRANT (S) .............................................................................................................................. 10 2.6. MODIFICATIONS ......................................................................................................................................................... 10 3. TEST CONDITIONS AND RESULTS .................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Frank Hao(Manager)
[email protected]Fax: +86-13691649917

Test Firm

Shenzhen CTL Testing Technology Co., Ltd.Tracy Qi
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.30 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.

Other Applications from OBDSPACE TECHNOLOGY CO,.LTD

VCI U1 - FCC ID 2ASC7VCIU15 - OBDSPACE TECHNOLOGY CO,.LTD
2ASC7VCIU15

VCI U1

Oct 13, 2024

Equipment Class

DTS - Digital Transmission System
VCI T6 - FCC ID 2ASC7VCIU18 - OBDSPACE TECHNOLOGY CO,.LTD
2ASC7VCIU18

VCI T6

Oct 13, 2024

Equipment Class

DTS - Digital Transmission System
Truck Scanner - FCC ID 2ASC7-HD43X - OBDSPACE TECHNOLOGY CO,.LTD
2ASC7-HD43X

Truck Scanner

Jul 06, 2024

Equipment Class

DTS - Digital Transmission System
Automotive Diagnostic Scan Tools - FCC ID 2ASC7-FH001 - OBDSPACE TECHNOLOGY CO,.LTD
2ASC7-FH001

Automotive Diagnostic Scan Tools

Feb 04, 2023

Equipment Class

DTS - Digital Transmission System
Professional Diagnostic Tool - FCC ID 2ASC7FX9000 - OBDSPACE TECHNOLOGY CO,.LTD
2ASC7FX9000

Professional Diagnostic Tool

Aug 12, 2020

Equipment Class

DTS - Digital Transmission System