Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 22, 2026
Application Purpose
Original Equipment
Equipment Note
Noble Astrid
Frequency Range
2402.00000000 - 2480.00000000
Company
Noble HiFi. LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

105mm 105mm 01 02 S XSSM ML RL 03 0506 0708 0910 1112 x1 x1 x1x1x6 13 0304 使用说明书 21 01 S XSSM ML 105mm 105mm True Wireless Stereo Earphone INSTRUCTION MANUAL Reset Button LED Light Indicators LED Light Indicators LED Light Indicators USB Type C Charging Port Multifunction Sensor (MFS) Multifunction Sensor (MFS) Microphone Microphone Packing ListOverview Charging Case x1EarphonesCharging Cable x1 Ear Tips x6Instruction Manual x1Storage Bag x1 Notes: Charging Steps: Please make sure the earphones and charging case are fully charged prior to first use. The earphones and charging case need to be clean and dry before and during the charging process. 1. The earphones will power o automatically when put back in the charging case and the charging lid is closed. The LED light will indicate the power capacity when lid is opened or closed. 2. Connect the charging case with power source by inserting the USB Type C charging cable. ChargingWireless charging 0506 0708 0910 Do not use the Noble Astrid earphones in locations prohibiting the use of electronic equipment. WARNING! Long-term exposure to high noise volumes may cause permanent hearing loss. Consult your physician prior to using your Noble Astrid earphones if you have a pacemaker or other electrical medical devices. This package contains small parts, which may pose a hazard to small children. Do not disassemble the Noble Astrid as it contains lithium batteries, and disassembly could result in electric shock or fire or serious injury. Any disassembly of the Noble Astrid, or attempt to replace or repair the Noble Astrid by an unauthorized person, will void the Noble FoKus Prestige Encore warranty. This product is not designed for use in water or wet environments. Keep product away from water and liquids. Failure to do so will void any warranty and may cause permanent damage to the product. Dispose of the product if it becomes swollen or cracked as it may be an indication that the battery is degraded and may burst and cause a fire. Declarations and Warnings Disconnect previous devices before pairing a new device. 1112 1314 21 5” * If the earphones cannot pair to each other or to your bluetooth devices, please reset them. 1. Put both earphones into the charging case 2. Hold the reset button for 5 seconds until the blue LED lights on both earphones flash quickly. All previously paired devices will be cleared.The reset process is completed. In the case that only one earphone is accidently reset, both earphones will need to be reset to function as a pair again. 21 Reset Procedure 5” RL 04 2 OFF 1 ON To manually turn the earphones on, hold the MFS button for 3 seconds. To manually turn o the earphones, hold the MFS button for 7 seconds. Both sides will power o automatically. The earphones will power on automatically when charging lid is opened. The earphones will power o automatically when put back in the charging case and the charging lid is closed. Power On / O 2 OFF 1 ON Noble Astrid Settings Bluetooth Bluetooth DEVICES Pairing a new device Pairing The Noble Astrid will need to be paired to your device before use. Once paired, they will connect automatically each time they are activated. 1. Open the lid of the charging case. The earphones will power on automatically and enter pairing mode, Blue and white LED light flashes. 2. Enable Bluetooth on your smartphone and search for "Noble Astrid" in available Bluetooth devices. Once found, select "Noble Astrid" to initiate pairing. You will hear "connected", now the earphones are ready for use. 1. Open the lid of your charging case. The earphones will power on automatically and connect to your current device. 2. To unpair the earphones from your last connected smartphone by "disconnecting" or deleting " Noble Astrid" from your smartphone's Bluetooth device list. 3. Once disconnected, the earphones will automatically enter pairing mode, with blue and white indicator lights flashing alternately. 4. Enable Bluetooth on your new device, and search for "Noble Astrid" in the available Bluetooth devices. Once found, select "Noble Astrid" to initiate pairing. You will hear "connected", now the earphones are ready for use. Pairing/Unpairing Procedure Noble Astrid Settings Bluetooth Bluetooth DEVICES 21 S XSSM ML 1. Select an ear tip size suitable for your ear and slide them on to the tip of the earphone. The case will automatically begin charging once placed on a wireless charger, The LED indicator on your earbuds case will confirm charging status. *(Wireless charger must be purchased separately.) 2. Insert the earphones into your ear canals and adjust them to a comfortable fit. Be sure that the eartips have a secure seal. Fit 21 S XSSM ML 21 Ambient Mode In standby mode or when playing music Press and hold for 3 secs Press and hold the left earbud touch sensor for 3 seconds with voice prompt “Ambient Mode On”, it will activate the external sound capturing function. Press and hold the left earbud touch sensor for 3 seconds with voice prompt “ANC On”, will filter out external noise. Press and hold the left earbud touch sensor for 3 seconds with voice prompt “ANC O ”, Will return to normal mode. There are three modes available. “Ambient Mode”, “ANC On”, and “ANC o mode”. To switch between modes, press and hold the left earbud for 3 secs. The voice prompt will confirm current selected mode. Ambient Mode On ANC On ANC o mode Press and hold for 3 secs Press and hold for 3 secs Press and hold for 3 secs Operation Single Click MFSL/R Single Click MFSL/R Triple Click MFS (L Double Click MFS (L) Triple Click MFS R Double Click MFSR Press the MFS for 3 secondsR Press the MFS for 2 secondsL/R Press the MFS for 3 secondsL Play/Pause Volume Up+ Volume Down- Previous Track Next Track Answer Call/Hang Up Reject Call Voice Assistant function- Siri / Google Ambient mode / ANC mode 02 Scan this QR code for Product Registration and to find this manual in other languages Android Noble FoKus App Specification Type C 500mAh 65m…

Text truncated - open the document above for the full version.

Cover Letter(s)

Noble HiFi. LLC Add: 109 State Hwy. 110 S,Whitehouse, Texas 75791,United States Date: 2026-9-17 FCC ID: 2AT8X-NBASTRID Dear Sir/Madam, We, Noble HiFi. LLC Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of the left&right earphones are the same for the following model: Product name: Noble Astrid Model no.: Noble Astrid Sincerely, Name/Title: Jim Moulton/Manager Company: Noble HiFi. LLC Address: 109 State Hwy. 110 S,Whitehouse, Texas 75791,United States Phone: 903-780-2540 Fax: 903-705-6860 E-Mail: [email protected]

External Photos

PageDNT2607305363R11621-P01: 1 of 7 PHOTOGRAPHSOFEUT FCCID:2AT8X-NBASTRID ExternalPhotos ExternalPhotos (Left) PageDNT2607305363R11621-P01: 2 of 7 ExternalPhotos (Left) ExternalPhotos (Left) PageDNT2607305363R11621-P01: 3 of 7 ExternalPhotos (Left) ExternalPhotos (Left) PageDNT2607305363R11621-P01: 4 of 7 ExternalPhotos (Left) ExternalPhotos (Right) PageDNT2607305363R11621-P01: 5 of 7 ExternalPhotos (Right) ExternalPhotos (Right) PageDNT2607305363R11621-P01: 6 of 7 ExternalPhotos (Right) ExternalPhotos (Right) PageDNT2607305363R11621-P01: 7 of 7 ExternalPhotos (Right) --END--

ID Label/Location Info

              

Internal Photos

PageDNT2607305363R11621-P01: 1 of 5 PHOTOGRAPHSOFEUT FCCID:2AT8X-NBASTRID InternalPhotos (Left) InternalPhotos (Left) PageDNT2607305363R11621-P01: 2 of 5 InternalPhotos (Left) InternalPhotos(Left) PageDNT2607305363R11621-P01: 3 of 5 InternalPhotos (Right) InternalPhotos (Right) PageDNT2607305363R11621-P01: 4 of 5 InternalPhotos (Right) InternalPhotos (Right) PageDNT2607305363R11621-P01: 5 of 5 InternalPhotos InternalPhotos --END--

RF Exposure Info

GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Tel:+86-769-88087383E-mail:[email protected] RFExposureEvaluationReport ApplicationNo.: DNT2607305363R11621-16076 Applicant: NobleHiFi,LLC AddressofApplicant: 109StateHwy.110SWhitehouse,Texas75791,UnitedStates EUTDescription: NobleAstrid ModelNo.: NobleAstrid FCCID: 2AT8X-NBASTRID PowerSupply (ChargingBox): Input:DC5V;DC3.7Vfromrechargeablelithium-ionbattery PowerSupply (Earphone): DC3.6Vfromrechargeablelithium-ionbattery TradeMark: NOBLE Standards: 47CFRPart2.1093 FCCKDB447498D04v01 DateofReceipt: 2026/07/30 DateofTest: 2026/07/30to2026/08/24 DateofIssue: 2026/08/28 TestResult:PASS PreparedBy:(TestingEngineer) ReviewedBy:(ProjectEngineer) ApprovedBy:(Manager) Note:Ifthereisanyobjectiontotheresultsinthisreport,pleasesubmitawritteninquirytothecompanywithin15daysfromthedateof receivingthereport.Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,andisissuedbythecompanyinaccordance withtherequirementsofthe"ConditionsofIssuanceofTestReports"printedintheattachedpage.Unlessotherwisestated,theresults presentedinthisreportonlyapplytothesamplestestedthistime.Partialreproductionofthisreportisnotallowedunlessapprovedbythe companyinwriting. ReportNo.:DNT2607305363R11621-16076Date:August28,2026Page: 2 / 8 GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Tel:+86-769-88087383E-mail:[email protected] ReportReviseRecord ReportVersionReviseTimeIssuedDateValidVersionNotes V1.0/August28,2026ValidOriginalReport ReportNo.:DNT2607305363R11621-16076Date:August28,2026Page: 3 / 8 GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Tel:+86-769-88087383E-mail:[email protected] Contents RFEXPOSUREEVALUATIONREPORT.............................................................................................................................................1 1GENERALINFORMATION..................................................................................................................................................................4 1.1TESTLOCATION.................................................................................................................................................................................4 1.2GENERALDESCRIPTIONOFEUT.....................................................................................................................................................4 1.3TESTFACILITY...................................................................................................................................................................................5 1.4MEASUREMENTUNCERTAINTY(95%CONFIDENCELEVELS,K=2)....................................................................................................5 2RFEXPOSUREEVALUATION............................................................................................................................................................6 2.1RFEXPOSURECOMPLIANCEREQUIREMENT..................................................................................................................................6 ReportNo.:DNT2607305363R11621-16076Date:August28,2026Page: 4 / 8 GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Tel:+86-769-88087383E-mail:[email protected] 1GeneralInformation 1.1TestLocation Company:GuangdongDNTestingCo.,Ltd Address: No.1,WestFourthStreet,SouthXinfaRoad,WushaLiwu,Chang’anTown, DongguanCity,GuangdongP.R.China Testengineer:GaliLin 1.2GeneralDescriptionofEUT Manufacturer: THEDARKHORSEACOUSTICSTECHNOLOGYCO.,LTD AddressofManufacture: 501,No.1,SportsRoad2,PinghuanCommunity,maruanStreet,PingshanDistrict, shenzhen,518118,china Factory: THEDARKHORSEACOUSTICSTECHNOLOGYCO.,LTD AddressofFactory: 501,No.1,SportsRoad2,PinghuanCommunity,maruanStreet,PingshanDistrict, shenzhen,518118,china ProductName: NobleAstrid ModelNo.: NobleAstrid AdditionalModel: / PowerSupply (ChargingBox): Input:DC5V;DC3.7Vfromrechargeablelithium-ionbattery PowerSupply (Earphone): DC3.6Vfromrechargeablelithium-ionbattery TradeMark: NOBLE HardwareVersion:V1.0 SoftwareVersion:V1.0 Serialnumber:PR2607305363R11621 ChipType:QCC3091 SampleType:PortableDevice,Module,MobileDevice AntennaType: External,Integrated AntennaPorts: Ant1,Ant2,Ant3 AntennaGain: Providedbyapplicant LeftANT:-2.80dBi;RightANT:-3.03dBi Note: *Sincetheabovedataand/orinformationisprovidedbytheclientrelevantresultsorconclusionsofthis reportareonlymadeforthesedataand/orinformation,DNTisnotresponsiblefortheauthenticity,integrityand resultsofthedataandinformationand/orthevalidityoftheconclusion. ReportNo.:DNT2607305363R11621-16076Date:August28,2026Page: 5 / 8 GuangdongDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Tel:+86-769-88087383E-mail:[email protected] 1.3TestFacility Thetestfacilityisrecognized,certified,oraccreditedbythefollowingorganizations: LabA: •FCC,USA DesignationNumber:CN1348 •A2LA(CertificateNo.7050.01) GUANGDONGDNTESTINGCO.,LTD.isaccreditedbytheAmericanAssociationforLaboratory Accreditation(A2LA).CertificateNo.7050.01. •Innovation,ScienceandEconomicDevelopmentCanada GUANGDONGDNTESTINGCO.,LTD.EMCLaboratoryhasbeenrecognizedbyISEDasanaccreditedtesting laboratory.CABidentifierisCN0149. IC#:30755. . 1.4MeasurementUncertainty(95%confidencelevels,k=2) No.ItemMeasurementUncertainty 1 20dBEmissionBandwidth±0.0196% 2 CarrierFrequencySeparation±1.9% 3 NumberofHoppingChannel±1.9% 4 TimeofOccupancy±0.028% 5 MaxPeakConductedOutputPower±0.743dB 6 Band-edgeSpuriousEmission±1.328dB 7 ConductedRFSpuriousEmission 9KHz-1GHz:±0.746dB 1GHz-26GHz:±1.328dB No.ItemMeasurementUncertainty 1ConductionEmission±3.0dB(150kHzto30MHz) 2RadiatedEmission ±4.…

Text truncated - open the document above for the full version.

Test Report

◆项目信息(Project information) ◆测试设备(Test Equipment) ◆机台图片Machine image ◆实际测试图片(test photo) ◆主板匹配电路(Main board matching circuit) ◆天线位置(ANT Location) ◆Return Loss&VSWR ◆辐射方向图(Radiation pattern) ◆无源效率、增益测试报告(Passive efficiency and gain test report) ◆有源3D&2D场型图(Active 3D&2D field pattern diagrams) ◆有源OTA ◆拉距测试 ◆抗干扰测试 ◆触摸稳定性测试 目录(List) ◆项目信息(Project information) 客户名CUSTOMER NAME: 黑马 项目名PRODUCT NAME: Hi-2606A 研发(R&D): 李良 日期DATE: 2026/08/10 制造商地址(Manufacturer address): Room 711, Building 2Gaoxinqilndustrail Park 2, Longchang Road, Bao'anDistrict, Shenzhen City, China 制造商信息(Manufacturer information): 深圳顶设科技有限公司(I-TOP DESIGN TECHNOLOGY CO.,LTD ) 1.有源测试:支持2.3.4.5G制式多模式测量NB-loT, eMTC,CAT- 1,Bluetooth1-5 ,WIFI802.11 abgn,可测TRP TIS 2.无源测试:可测试增益,效率 3.TWS耳机测试头模全套人头手 一.测试设备(TestEquipment) 二.机台图片Machine image Definition of darkroom coordinate axis: H: XY axis E1: XZ axis E2: YZ axis 三实际测试图片(test photo) Y X Z 自由空间 Definition of darkroom coordinate axis: H: XY axis E1: XZ axis E2: YZ axis 三实际测试图片(test photo) Y X Z 头模空间 四主板匹配电路(Main board matchingcircuit) 串联电阻 R=0Ω 天线 进系统端 NC NC 五.天线位置(ANT Location) LR 六.Return Loss&VSWR L 六.Return Loss&VSWR R 七.辐射方向图(Radiation pattern) L -2400MHZ 七.辐射方向图(Radiation pattern) R -2400MHZ 七.辐射方向图(Radiation pattern) L -2450MHZ 七.辐射方向图(Radiation pattern) R -2450MHZ 七.辐射方向图(Radiation pattern) L -2500MHZ 七.辐射方向图(Radiation pattern) R -2500MHZ 八.无源效率、增益(Passive efficiency and gain ) 2400MHZ-2500MHZ LR Frequency (MHz) Gain (dBi) Efficiency (%) Frequency (MHz) Gain (dBi) Efficiency (%) 2400 -3.75 16.15 2400 -5.65 10.84 2410 -3.32 17.40 2410 -4.6311.87 2420 -3.06 17.64 2420 -3.86 12.85 2430 -2.80 18.37 2430 -3.27 13.97 2440 -2.86 18.22 2440 -3.0314.94 2450 -3.07 18.05 2450 -3.0915.32 2460 -3.54 17.54 2460 -3.25 15.44 2470 -3.81 17.18 2470 -3.3815.67 2480 -4.00 16.56 2480 -3.3315.63 2490 -4.08 15.85 2490 -3.2016.32 2500 -4.15 15.27 2500 -3.3616.22 九.有源3D&2D场型图-L-自由空间-TRP (Active 3D&2D field pattern -L-Free space -TRP) 0 39 78 九.有源3D&2D场型图-R-自由空间-TRP (Active 3D&2D field pattern -L-Free space -TRP) 0 39 78 九.有源3D&2D场型图-L-自由空间-TIS (Active 3D&2D field pattern -L-Free space -TIS) 0 39 78 九.有源3D&2D场型图-R-自由空间-TIS (Active 3D&2D field pattern -R-Free space -TIS) 0 39 78 九.有源3D&2D场型图-L-头模-TRP (Active 3D&2D field pattern -L-Head mold -TRP) 0 39 78 九.有源3D&2D场型图-R-头模-TRP (Active 3D&2D field pattern -R-Head mold -TRP) 0 39 78 九.有源3D&2D场型图-L-头模-TIS (Active 3D&2D field pattern -L-Head mold -TIS) 0 39 78 九.有源3D&2D场型图-R-头模-TIS (Active 3D&2D field pattern -R-Head mold -TIS) 0 39 78 十.OTA有源(OTA active) OTA 有源 Test Conditio n 自由空间 头模 bandChannelTRP (dBm)TIS (dBm)TRP (dBm)TIS (dBm) L 0 1.58-85.551.49-85.34 39 1.21-83.390.17-82.16 78 1.88-83.420.91-82.77 0 -1.84-85.250.15-84.58 39 -2.61-82.58-1.03-81.02 78 -0.48-83.910.38-81.88 十一.抗干扰测试 十二.拉距测试 十三.触摸稳定性测试

Test Report

Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] FCC Test Report Application No.: DNT2607305363R11621-16072 Applicant: Noble HiFi, LLC Address of Applicant: 109 State Hwy. 110 S Whitehouse, Texas 75791,United States EUT Description: Noble Astrid Model No.: Noble Astrid FCC ID: 2AT8X-NBASTRID Power Supply (Charging Box): Input:DC 5V;DC 3.7V from rechargeable lithium-ion battery Power Supply (Earphone ): DC 3.6V from rechargeable lithium-ion battery Trade Mark: NOBLE Standards: 47 CFR Part 2, Subpart J 47 CFR Part 15, Subpart C ANSI C63.10: 2020 Date of Receipt: 2026/07/30 Date of Test: 2026/07/30 to 2026/08/24 Date of Issue: 2026/08/28 Test Result:PASS Prepared By:(Testing Engineer) Reviewed By:(Project Engineer) Approved By:(Manager) Note: If there is any objection to the results in this report, please submit a written inquiry to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp, and is issued by the company in accordance with the requirements of the "Conditions of Issuance of Test Reports" printed in the attached page. Unless otherwise stated, the results presented in this report only apply to the samples tested this time. Partial reproduction of this report is not allowed unless approved by the company in writing. Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 2 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] Report Revise Record Report VersionRevise TimeIssued DateValid VersionNotes V1.0/August 28, 2026ValidOriginal Report Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 3 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] 1 Test Summary Test ItemTest RequirementTest MethodTest ResultResult Antenna Requirement15.203/247(b)--Clause 3.1PASS 20dB Emission Bandwidth15.247 (a)(1)ANSI C63.10: 2020Clause 3.2PASS Conducted Peak Output Power 15.247 (b)(1)ANSI C63.10: 2020Clause 3.3PASS Carrier Frequencies Separation 15.247 (a)(1)ANSI C63.10: 2020Clause 3.4PASS Dwell Time15.247 (a)(1)ANSI C63.10: 2020Clause 3.5PASS Hopping Channel Number15.247 (a)(1)ANSI C63.10: 2020Clause 3.6PASS Band-edge for RF Conducted Emissions 15.247(d)ANSI C63.10: 2020Clause 3.7PASS RF Conducted Spurious Emissions 15.247(d)ANSI C63.10: 2020Clause 3.8PASS Radiated Spurious emissions 15.247(d); 15.205/15.209 ANSI C63.10: 2020Clause 3.9PASS Restricted bands around fundamental frequency (Radiated Emission) 15.247(d); 15.205/15.209 ANSI C63.10: 2020Clause 3.10PASS AC Power Line Conducted Emission 15.207ANSI C63.10: 2020Clause 3.11PASS Note: 1. “N/A” denotes test is not applicable in this test report. Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 4 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] Contents 1 Test Summary..................................................................................................................................................................3 2 General Information..........................................................................................................................................................5 2.1 Test Location..........................................................................................................................................................5 2.2 General Description of EUT...................................................................................................................................6 2.3 Test Environment...................................................................................................................................................7 2.4 Channel List........................................................................................................................................................... 7 2.5 Power Setting of Test Software............................................................................................................................. 8 2.6 Assistant equipment used for test..........................................................................................................................8 2.7 Description of Support Units.................................................................................................................................. 8 2.8 Test Facility............................................................................................................................................................8 2.9 Equipment List....................................................................................................................................................... 9 2.10 Measurement Uncertainty (95% confidence levels, k=2).................................................................................. 11 3 Test results and Measurement Data..............................................................................................................................12 3.1 Antenna Requirement..........................................................................................................................................12 3.2 20dB Emission Bandwidth................................................................................................................................... 13 3.3 Conducted Output Power.................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 53 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] 2DH5_Ant1_Low_2402 2DH5_Ant1_High_2480 2DH5_Ant1_Low_Hop_2402 Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 54 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] 2DH5_Ant1_High_Hop_2480 3DH5_Ant1_Low_2402 3DH5_Ant1_High_2480 Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 55 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] 3DH5_Ant1_Low_Hop_2402 3DH5_Ant1_High_Hop_2480 Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 56 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] Appendix G: Conducted Spurious Emission Test Result TestModeAntennaFreq(MHz) FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5Ant1 2402 Reference0.340.34---PASS 30~10000.34-68.59≤-19.66PASS 1000~265000.34-48.46≤-19.66PASS 2441 Reference-0.17-0.17---PASS 30~1000-0.17-68.69≤-20.17PASS 1000~26500-0.17-48.02≤-20.17PASS 2480 Reference0.150.15---PASS 30~10000.15-68.67≤-19.85PASS 1000~265000.15-49.27≤-19.85PASS 2DH5Ant1 2402 Reference-1.07-1.07---PASS 30~1000-1.07-68.18≤-21.07PASS 1000~26500-1.07-49.07≤-21.07PASS 2441 Reference-0.92-0.92---PASS 30~1000-0.92-68.19≤-20.92PASS 1000~26500-0.92-47.41≤-20.92PASS 2480 Reference-0.81-0.81---PASS 30~1000-0.81-68.03≤-20.81PASS 1000~26500-0.81-47.47≤-20.81PASS 3DH5Ant1 2402 Reference-1.03-1.03---PASS 30~1000-1.03-68.81≤-21.03PASS 1000~26500-1.03-48.34≤-21.03PASS 2441 Reference-0.84-0.84---PASS 30~1000-0.84-69.03≤-20.84PASS 1000~26500-0.84-48.89≤-20.84PASS 2480 Reference-0.73-0.73---PASS 30~1000-0.73-68.23≤-20.73PASS 1000~26500-0.73-49.08≤-20.73PASS Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 57 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] Test Graphs DH5_Ant1_2402_0~Reference DH5_Ant1_2402_30~1000 DH5_Ant1_2402_1000~26500 DH5_Ant1_2441_0~Reference Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 58 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] DH5_Ant1_2441_30~1000 DH5_Ant1_2441_1000~26500 DH5_Ant1_2480_0~Reference Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 59 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] DH5_Ant1_2480_30~1000 DH5_Ant1_2480_1000~26500 2DH5_Ant1_2402_0~Reference Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 60 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] 2DH5_Ant1_2402_30~1000 2DH5_Ant1_2402_1000~26500 2DH5_Ant1_2441_0~Reference Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 61 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] 2DH5_Ant1_2441_30~1000 2DH5_Ant1_2441_1000~26500 2DH5_Ant1_2480_0~Reference Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 62 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] 2DH5_Ant1_2480_30~1000 2DH5_Ant1_2480_1000~26500 3DH5_Ant1_2402_0~Reference Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 63 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] 3DH5_Ant1_2402_30~1000 3DH5_Ant1_2402_1000~26500 3DH5_Ant1_2441_0~Reference Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 64 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] 3DH5_Ant1_2441_30~1000 3DH5_Ant1_2441_1000~26500 3DH5_Ant1_2480_0~Reference Report No.: DNT2607305363R11621-16072Date:August 28, 2026Page: 65 / 65 Guangdong DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Tel:+86-769-88087383E-mail: [email protected] 3DH5_Ant1_2480_30~1000 3DH5_Ant1_2480_1000~26500 ---End of Report---

Test Setup Photos

PageDNT2607305363R11621-P01: 1 of 3 PHOTOGRAPHSOFEUT FCCID:2AT8X-NBASTRID AntennaTerminalTestView PageDNT2607305363R11621-P01: 2 of 3 ConducedEmissionTestView RadiatedEmissionTestView(Below1G) PageDNT2607305363R11621-P01: 3 of 3 RadiatedEmissionTestView(Above1G) --END--

Contact Information

Applicant

Jim Moulton(Manager)
[email protected]Fax: 903-705-6860

Technical Contact

HOORAY INDUSTRY LLCCindy Wu
[email protected]

1408 Pinon Place, Fullerton, · United States

Test Firm

Guangdong DN Testing Co., Ltd.Joise Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.40 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.

Other Applications from Noble HiFi. LLC

2AT8X-FALCONMAX

True Wireless Stereo Earbuds

Jan 22, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
True Wireless Stereo Earphone - FCC ID 2AT8X-FOKUSPRO - Noble HiFi. LLC
2AT8X-FOKUSPRO

True Wireless Stereo Earphone

Aug 24, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth earphone - FCC ID 2AT8X-FALCONPRO - Noble HiFi. LLC
2AT8X-FALCONPRO

Bluetooth earphone

Dec 01, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth earphone - FCC ID 2AT8X-FALCONII - Noble HiFi. LLC
2AT8X-FALCONII

Bluetooth earphone

Oct 12, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter