FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Guangdong Invitop Technology Co., Ltd./
  3. 2ATIZ-CL-1

2ATIZ-CL-1Air Cooler

Guangdong Invitop Technology Co., Ltd.
Air Cooler - FCC ID 2ATIZ-CL-1 - Guangdong Invitop Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 31, 2020
Application Purpose
Original Equipment
Date of Application
May 31, 2020
Equipment Note
Air Cooler
Frequency Range
2412.00000000 - 2462.00000000
Company
Guangdong Invitop Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

β†—
β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

RF Exposure Info

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

1EXTERNALPHOTOS: ---TheEnd---

Internal Photos

Internalphotos: ---TheEnd---

RF Exposure Info

FCCID:2ATIZ-CL-1 RFEXPOSUREEVALUATION AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeusedtoevaluate theenvironmentimpactofhumanexposuretoradiofrequency(RF)Radiationasspecifiedin Β§1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) Power Density(mW/cm 2 ) AverageTime (A)LimitsforOccupational/ControlExposures 300-1500----F/3006 1500-100000----56 (B)LimitsforGeneralPopulation/UncontrolExposures 300-1500----F/15006 1500-100000----130 11.1Friistransmissionformula:Pd=(Pout*G)\(4*pi*R 2 ) Where Pd=PowerdensityinmW/cm 2 Pout=outputpowertoantennainmW G=Numericgainoftheantennarelativetoisotropicantenna Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorin20cm PdthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainofthendtotalpowerinputto theantenna,throughthecalculation,wewillknowthedistancewheretheMPElimitis reached. 11.2MeasurementResult Mode Max Measured power (dBm) Max tune-up power (dBm) Antenna gain Antenna Gain Numeric Evaluation result (mW/cm2) Powerdensity Limits (mW/cm2) WIFI16.4118320.0251

Test Report

TEST REPORT Product NameAir Cooler Model NumberCL-1, CL-2 FCC ID2ATIZ-CL-1 Prepared for: Guangdong Invitop Technology Co.Ltd. Address:B-6F, NO.6,Xinhua Road, Sanjiao Town, Zhongshan, Guandong P.R.C Prepared by:EMTEK (SHENZHEN) CO., LTD. Address:Bldg 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guangdong, China Tel: (0755) 26954280 Fax: (0755) 26954282 Report Number:ES200413049W Date(s) of Tests:April 14, 2020 to May 16, 2020 Date of issue:May 22, 2020 $$ TABLE OF CONTENTS 1 TEST RESULTCERTIFICATION..............................................................................................................................3 2 EUT TECHNICALDESCRIPTION............................................................................................................................5 3 SUMMARYOFTEST RESULT...................................................................................................................................6 4 TEST METHODOLOGY..............................................................................................................................................7 4.1 GENERAL DESCRIPTION OFAPPLIED STANDARDS..................................................................................... 7 4.2 MEASUREMENT EQUIPMENT USED.................................................................................................................7 4.3 DESCRIPTION OF TEST MODES......................................................................................................................... 8 5 FACILITIESANDACCREDITATIONS.....................................................................................................................9 5.1 FACILITIES..............................................................................................................................................................9 5.2 LABORATORYACCREDITATIONSAND LISTINGS..........................................................................................9 6 TEST SYSTEM UNCERTAINTY..............................................................................................................................10 7 SETUPOFEQUIPMENT UNDER TEST.................................................................................................................11 7.1 RADIO FREQUENCYTEST SETUP1.................................................................................................................11 7.2 RADIO FREQUENCYTEST SETUP2.................................................................................................................11 7.3 CONDUCTED EMISSION TEST SETUP.............................................................................................................12 7.4 BLOCK DIAGRAM CONFIGURATION OF TEST SYSTEM.............................................................................13 7.5 SUPPORT EQUIPMENT........................................................................................................................................13 8 TEST REQUIREMENTS............................................................................................................................................14 8.1 DTS(6DB)BANDWIDTH.......................................................................................................................................14 8.2 MAXIMUM PEAK CONDUCTED OUTPUT POWER....................................................................................... 20 8.3 MAXIMUM POWER SPECTRAL DENSITY......................................................................................................21 8.4 UNWANTED EMISSIONS IN NON-RESTRICTED FREQUENCY BANDS....................................................27 8.5 RADIATED SPURIOUS EMISSION.....................................................................................................................32 8.6 CONDUCTED EMISSIONS TEST........................................................................................................................44 8.7ANTENNAAPPLICATION....................................................................................................................................47 1 TEST RESULT CERTIFICATION Applicant: Guangdong Invitop Technology Co.,Ltd. Address B-6F, NO.6,Xinhua Road, Sanjiao Town, Zhongshan, Guandong P.R.C Manufacturer: Guangdong Invitop Technology Co. , Ltd. Address B-6F, NO.6,Xinhua Road, Sanjiao Town, Zhongshan, Guandong P.R.C EUT: Air Cooler Model Name: CL-1, CL-2 Trademark: N/A Measurement Procedure Used: APPLICABLE STANDARDS STANDARDTEST RESULT FCC 47 CFR Part 2 , Subpart J FCC 47 CFR Part 15 , Subpart C PASS The above equipment was tested by EMTEK (SHENZHEN) CO., LTD. The test data,data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.10 (2013) and the energy emitted by the sampleEUT tested as described in this report is in compliance with the requirements of FCC Rules Part 2 and Part 15.247 The test results of this report relate only to the tested sample identifiedin this report. Date of Test :April 14, 2020 to May 16, 2020 Prepared by : Mill Chen /Editor Reviewer : Sewen Guo /Supervisor Approve & Authorized Signer : Lisa Wang / Manager Modified History VersionReport No.Revision dateSummary Ver.1.0ES200413049W/Original Report 2 EUT TECHNICAL DESCRIPTION Note:for more details, please refer to the User’s manual of the EUT. CharacteristicsDescription Product:Air Cooler Model Number: CL-1, CL-2 (Note: All models are identical in circuitry and electrical, mechanical and physical construction; the difference are the appearance and model numberfor trading purpose, we prepared CL-1 for test.) IEEE 802.11 WLAN Mode Supported 802.11b 802.11g 802.11n(20MHz channel bandwidth) Data Rate 802.11 b:1,2,5.5,11Mbps; 802.11 g:6,9,12,18,24,36,48,54Mbps; 802.11n(HT20): 6.5M,13M,19.5M,26M,39M,52M,58.5M,65M; Modulation DSSS with DBPSK/DQPSK/CCK for 802.11b; OFDM with BPSK/QP…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Conducted ---TheEnd---

Contact Information

Applicant

Tom Chen(QC manager)
[email protected]+86 13420676346Fax: +86 13420676346

Test Firm

EMTEK (Shenzhen) Co., Ltd.Lisa Wang
[email protected]86 755 26954280

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz44.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. Device must be operated to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Guangdong Invitop Technology Co., Ltd.

Air purifier - FCC ID 2ATIZMEKI - Guangdong Invitop Technology Co., Ltd.
2ATIZMEKI

Air purifier

Sep 07, 2024

Equipment Class

DTS - Digital Transmission System
AIR PURIFIER - FCC ID 2ATIZDEMI - Guangdong Invitop Technology Co., Ltd.
2ATIZDEMI

AIR PURIFIER

May 09, 2023

Equipment Class

DTS - Digital Transmission System
Ice Maker - FCC ID 2ATIZ-ICEQ3 - Guangdong Invitop Technology Co., Ltd.
2ATIZ-ICEQ3

Ice Maker

Aug 28, 2022

Equipment Class

DTS - Digital Transmission System
AIR PURIFIER - FCC ID 2ATIZCAMI - Guangdong Invitop Technology Co., Ltd.
2ATIZCAMI

AIR PURIFIER

Aug 20, 2022

Equipment Class

DTS - Digital Transmission System
Heater - FCC ID 2ATIZH3 - Guangdong Invitop Technology Co., Ltd.
2ATIZH3

Heater

Aug 13, 2022

Equipment Class

DTS - Digital Transmission System