
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Rev11/20/07 ZhongshanInvitopElectricalCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationof FCCID:2ATIZ-X3 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName BlockDiagram,Schematics,Operational Description BlockDiagram OperationDescription schematicdiagram Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. Sincerely, TomChen/QCmanager ZhongshanInvitopElectricalCo.,Ltd.
Declarationonmodeldifference 产品差异声明 Page1of1page Wetheundersignedherebyconfirmthatanyofourproductionunitsbearingthefollowingmodel numbersareidenticalincircuitryandelectrical,mechanicalandphysicalconstruction;thedifference isjusttheappearance. FCCID:2ATIZ-X3 Productionname 产品名称 Tradename 商标 Modelno. 型号 DehumidifierN/A X1,X3,X6 ConfirmedbyZhongshanInvitopElectricalCo.,Ltd. AuthorizedSignature:TomChen/QCmanager 授权人签字 Date:2020-03-06 日期
M:\MasterDocuments\TEMPLATES\POA_Letter.doc ZhongshanInvitopElectricalCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 1435OaklandMillsRoad Columbia,MD21046 Date:2020-03-06 SUBJECT:FCCApplicationforFCCID:2ATIZ-X3 ToWhomItMayConcern: We,theundersigned,herebyauthorizeLisaWangatEMTEK(SHENZHEN)CO.,LTD.on ourbehalf,toapplytotheFederalCommunicationsCommissiononourequipment.Any andallactscarriedoutbyEMTEK(SHENZHEN)CO.,LTD.onourbehalfshallhavethe sameeffectasactsofourown. ThisistoadvisethatweareinfullcompliancewiththeAnti-DrugAbuseAct.We,the applicant,arenotsubjecttoadenialoffederalbenefitspursuanttoSection5301ofthe Anti-DrugActof1988,21USC853a,andnopartytotheapplicationissubjecttoadenial offederalbenefitspursuanttothatsection. Regards, TomChen/QCmanager ZhongshanInvitopElectricalCo.,Ltd.
1EXTERNALPHOTOS: ---TheEnd---
Home Dehumidifie「 Model:X3 Made In China Voltage: AC100-120V 50/60Hz Po wer : 6 5 0 W r5l ::E:' ( t � FCC ID, 2AT I Z-X3 』- - -唱·‘国, This device complies with part 15 of the FCC Rules. Operati。n is subject to the following two conditions: (1)Thls d时国maynot cause harmful lnte巾ran佣 a (2) this davice must ac国ptan y interference received, including inte巾ren四that may四U回undesiredoperation.,
Internalphotos: ---TheEnd---
FCCID:2ATIZ-X3 RFEXPOSUREEVALUATION AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeusedtoevaluate theenvironmentimpactofhumanexposuretoradiofrequency(RF)Radiationasspecifiedin §1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) Power Density(mW/cm 2 ) AverageTime (A)LimitsforOccupational/ControlExposures 300-1500----F/3006 1500-100000----56 (B)LimitsforGeneralPopulation/UncontrolExposures 300-1500----F/15006 1500-100000----130 11.1Friistransmissionformula:Pd=(Pout*G)\(4*pi*R 2 ) Where Pd=PowerdensityinmW/cm 2 Pout=outputpowertoantennainmW G=Numericgainoftheantennarelativetoisotropicantenna Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorin20cm PdthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainofthendtotalpowerinputto theantenna,throughthecalculation,wewillknowthedistancewheretheMPElimitis reached. 11.2MeasurementResult Mode Max Measured power (dBm) Max tune-up power (dBm) Antenna gain Antenna Gain Numeric Evaluation result (mW/cm2) Powerdensity Limits (mW/cm2) WIFI18.1419320.03151
Report No. ES191210027W Page 1 of 48 Ver.1.0 TEST REPORT Product Name : Dehumidifier Model Number:X1, X3, X6 FCC ID:2ATIZ-X3 Prepared for: Zhongshan Invitop Electrical Co.,Ltd. Address: B-6F, NO.6,Xinhua Road, Sanjiao Town, Zhongshan, Guandong P.R.C Prepared b y:EMTEK(SHENZHEN)CO., LTD. Address: Bldg 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guangdong, China Tel:(0755)26954280 Fax: (0755)26954282 Report Number: ES191210027W Date(s)of Tests : December 11, 2019 to March 3, 2020 Date of issue: March 6, 2020 $二维码$ Report No. ES191210027W Page 2 of 48 Ver.1.0 TABLE OF CONTENTS 1 TEST RESULT CERTIFICATION.............................................................................................................................. 3 2 EUT TECHNICAL DESCRIPTION............................................................................................................................ 5 3 SUMMARY OF TEST RESULT...................................................................................................................................6 4 TEST METHODOLOGY..............................................................................................................................................7 4.1 GENERAL DESCRIPTION OF APPLIED STANDARDS..................................................................................... 7 4.2 MEASUREMENT EQUIPMENT USED.................................................................................................................7 4.3 DESCRIPTION OF TEST MODES......................................................................................................................... 8 5 FACILITIES AND ACCREDITATIONS.....................................................................................................................9 5.1 FACILITIES..............................................................................................................................................................9 5.2 LABORATORY ACCREDITATIONS AND LISTINGS..........................................................................................9 6 TEST SYSTEM UNCERTAINTY.............................................................................................................................. 10 7 SETUP OF EQUIPMENT UNDER TEST................................................................................................................. 11 7.1 RADIO FREQUENCY TEST SETUP 1.................................................................................................................11 7.2 RADIO FREQUENCY TEST SETUP 2.................................................................................................................11 7.3 CONDUCTED EMISSION TEST SETUP.............................................................................................................12 7.4 BLOCK DIAGRAM CONFIGURATION OF TEST SYSTEM.............................................................................13 7.5 SUPPORT EQUIPMENT........................................................................................................................................13 8 TEST REQUIREMENTS............................................................................................................................................14 8.1 DTS(6DB)BANDWIDTH.......................................................................................................................................14 8.2 MAXIMUM PEAK CONDUCTED OUTPUT POWER....................................................................................... 20 8.3 MAXIMUM POWER SPECTRAL DENSITY...................................................................................................... 21 8.4 UNWANTED EMISSIONS IN NON-RESTRICTED FREQUENCY BANDS.................................................... 27 8.5 RADIATED SPURIOUS EMISSION.....................................................................................................................32 8.6 CONDUCTED EMISSIONS TEST........................................................................................................................44 8.7 ANTENNAAPPLICATION....................................................................................................................................47 Report No. ES191210027W Page 3 of 48 Ver.1.0 1 TEST RESULT CERTIFICATION Applicant: Zhongshan Invitop Electrical Co.,Ltd. Address : B-6F, NO.6,Xinhua Road, Sanjiao Town, Zhongshan, Guandong P.R.C Manufacturer: Zhongshan Invitop Electrical Co.,Ltd. Address : B-6F, NO.6,Xinhua Road, Sanjiao Town, Zhongshan, Guandong P.R.C EUT: Dehumidifier Model Name: X1, X3, X6 Trademark: N/A Measurement Procedure Used: APPLICABLE STANDARDS STANDARDTEST RESULT FCC 47 CFR Part 2 , Subpart J FCC 47 CFR Part 15 , Subpart C PASS The above equipment was tested by EMTEK (SHENZHEN) CO., LTD. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.10 (2013) and the energy emitted by the sample EUT tested as described in this report is in compliance with the requirements of FCC Rules Part 2 and Part 15.247 The test results of this report relate only to the tested sample identified in this report. Date of Test :December 11, 2019 to March 3, 2020 Prepared by : Mill Chen /Editor Reviewer : Sewen Guo / Supervisor Approve &Authorized Signer : Lisa Wang / Manager Report No. ES191210027W Page 4 of 48 Ver.1.0 Modified History VersionReport No.Revision dateSummary Ver.1.0ES191210027W/Original Report Report No. ES191210027W Page 5 of 48 Ver.1.0 2 EUT TECHNICAL DESCRIPTION Note:for more details, please refer to the User’s manual of the EUT. CharacteristicsDescription Product:Dehumidifier Model Number: X1, X3, X6 (Note: All models are identical in circuitry and electrical, mechanical and physical construction; the difference are the appearance and model number for trading purpose, we prepared X3 Bundle fo…
Text truncated - open the document above for the full version.
Radiated Conducted ---TheEnd---
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 65.00 mW |

Air purifier
Equipment Class
DTS - Digital Transmission System
AIR PURIFIER
Equipment Class
DTS - Digital Transmission System
Ice Maker
Equipment Class
DTS - Digital Transmission System
AIR PURIFIER
Equipment Class
DTS - Digital Transmission System
Heater
Equipment Class
DTS - Digital Transmission System