Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Radiation Exposure Statement This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers mustbe provide with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. FCC Radiation Exposure Statement This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers mustbe provide with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.
Hipcam Global LLC DATE : 2021/04/07 FCC ID: 2ATYCHMX04 Dear Sir, I hereby have entrusted the following person to be a proxy regarding application for Type Certification. Company name: BTL Inc. Address: 4F,No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist.114, Taipei, Taiwan Name: Melody Wu For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America, Inc, still resides with us. Signature FCC grantee contact person information. Name/Title: Leandro Weissmann/CFO Company Name: Hipcam Global LLC Address: 112 Capitol Trail, Newark, Delaware, 19711 TEL: +16467986464 FAX: + 16467986464 Email: [email protected]
Hipcam Global LLC DATE : 2021/04/07 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2ATYCHMX04 Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...) Schematics Block diagram Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Signature FCC grantee contact person information. Name/Title: Leandro Weissmann / CFO Company Name: Hipcam Global LLC Address: 112 Capitol Trail, Newark, Delaware, 1971 TEL: +16467986464 FAX: +16467986464 Email: [email protected]
Hipcam Global LLC DATE : 2021/04/07 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2ATYCHMX04 Request for Short-Term Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission rules, and in accordance with the FCC Public notice dated June 15, 2004 (DA 04-1705), we hereby request short-term confidentiality for the following items prior to marketing the device.: l Test Setup Photos l External Photos l Internal Photos l User Manual These documents contain detailed system and equipment description and related information about the product which Hipcam Global LLC considers to be proprietary, confidential, and a custom design and, otherwise would not release to the general public. Since this design is a basis from which future technological products will evolve, Hipcam Global LLCconsiders this information to be of benefit to its competitors, and that the disclosure of information in these documents would give competitors an unfair advantage in the market. This request is being made retroactively due to an over site on our part. We understand that the information has been publicly available 180 days after date of grant. Signature FCC grantee contact person information. Name/Title: Leandro Weissmann/CFO Company Name: Hipcam Global LLC Address: 112 Capitol Trail, Newark, Delaware, 19711 TEL: +16467986464 FAX: +16467986464 Email: [email protected]
Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 1 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 2 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 3 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 4 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 5 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 6 of 23 Adapter / SK03T-1200200Z Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 7 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 8 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 9 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 10 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 11 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 12 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 13 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 14 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 15 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 16 of 23
20210413 FCC ID: XXXXXXXXXXXXX IC ID: XXXXX-XXXXXXXX FCC ID: XXXXXXXXXXXXX IC ID: XXXXX-XXXXXXXX R胶75#珠光合成纸 Model Name: Outdoor Spotlight Camera Max Power Input: 12 VDC / 2A 24W FCC ID: 2ATYCHMX04 Address: 112 Capitol Trail, Newark, Delaware, United States, 19711 S/N: XXXXXXXXXXXXXXXXXXX HW: XXXX Model Name: Outdoor Spotlight Camera Max Power Input: 12 VDC / 2A 24W FCC ID: 2ATYCHMX04 Address: 112 Capitol Trail, Newark, Delaware, United States, 19711
Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 17 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 18 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 19 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 20 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 21 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 22 of 23 Appendix No.: EP-2101T111-1 APPENDIX-EUT PHOTOS Project No.: 2101T111 Page 23 of 23
Report No.: BTL-FCCP-6-2101T111 Project No.: 2101T111 Page 1 of 5 Report Version: R01 Maximum Permissible Exposure Report FCC ID: 2ATYCHMX04 Report No. : BTL-FCCP-6-2101T111 Equipment : HIPCAM Model Name : Outdoor Spotlight Camera Max Brand Name : HIPCAM Applicant : Hipcam Global LLC Address : 112 Capitol Trail, Newark, Delaware, 19711 United States Manufacturer : Goldtek Technology Co., Ltd. Address : 16F., No.166, Jian 1st Rd., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.) FCC Rule Part(s) : FCC CFR Title 47, Part 2 (2.1091) FCC Guidelines for Human Exposure IEEE C95.1 Date of Receipt : 2021/2/2 Date of Test : 2021/2/2 ~ 2021/3/17 Issued Date : 2021/4/16 The above equipment has been tested and found in compliance with the requirement of the above standards by BTL Inc. Prepared by : Peter Chen, Engineer Approved by : Scott Hsu, Manager BTL Inc. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan Tel: +886-2-2657-3299 Fax: +886-2-2657-3331 Web: www.newbtl.com Report No.: BTL-FCCP-6-2101T111 Project No.: 2101T111 Page 2 of 5 Report Version: R01 REVISON HISTORY Report No. Version Description Issued Date BTL-FCCP-6-2101T111 R00 Original Report. 2021/4/9 BTL-FCCP-6-2101T111 R01 Revised report to address TCB’s comments. 2021/4/16 Report No.: BTL-FCCP-6-2101T111 Project No.: 2101T111 Page 3 of 5 Report Version: R01 Table for Filed Antenna For LoRa: Ant. Manufacture Product Type Connector Frequency Range (MHz) Gain (dBi) 1 Lora US915 FPCB N/A 902-928 0.29 For BLE: Ant. Manufacture Product Type Connector Frequency Range (MHz) Gain (dBi) 1 Wi-Fi Ant. PCB N/A 2400-2500 3.86 For 2.4GHz WLAN: Ant. Manufacture Product Type Connector Frequency Range (MHz) Gain (dBi) 1 Wi-Fi Ant. PCB N/A 2400-2500 3.86 For 5GHz RLAN: Ant. Manufacture Product Type Connector Frequency Range (MHz) Gain (dBi) 1 Wi-Fi Ant. PCB N/A 5150-5250 4.67 5250-5350 5.38 5470-5725 5.23 5725-5850 5.23 Maximum RF OUTPUT POWER Mode Maximum Average Power (dBm) WLAN 2.4 GHz IEEE 802.11b 17.95 IEEE 802.11g 21.93 IEEE 802.11n (HT20) 22.28 RLAN 5 GHz IEEE 802.11a 13.49 IEEE 802.11n (HT20) 13.07 IEEE 802.11n (HT40) 10.40 BLE 4.97 Lora 17.46 Report No.: BTL-FCCP-6-2101T111 Project No.: 2101T111 Page 4 of 5 Report Version: R01 MPE CALCULATION METHOD: Calculation Method of RF Safety Distance: where: S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna RESULTS For BLE: Antenna Gain (dBi) Antenna Gain (numeric) Max. Output Power (dBm) Max. Output Power ( mW ) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Test Result 3.86 2.4322 4.97 3.1405 0.00152037 1 Complies For 2.4G WLAN: Antenna Gain (dBi) Antenna Gain (numeric) Max. Output Power (dBm) Max. Output Power ( mW ) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Test Result 3.86 2.4322 22.28 169.0441 0.08183713 1 Complies For 5G RLAN: Antenna Gain (dBi) Antenna Gain (numeric) Max. Output Power (dBm) Max. Output Power ( mW ) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Test Result 5.38 3.4514 13.49 22.3357 0.01534442 1 Complies Note: 1. The calculated distance is 20 cm. Report No.: BTL-FCCP-6-2101T111 Project No.: 2101T111 Page 5 of 5 Report Version: R01 For LoRa : Limit Frequency Range (MHz) Power Density (mW /cm 2 ) Averaging Time (minutes) 300~1500 F/1500 30 1500~100000 1.0 30 MPE EVALUATION FORMULA where: Pd= Power density in mW/cm2 Pt= EIRP in Mw Pi= 3.1416 R= Measurement distance RESULTS Frequency (MHz) Maximum Output Power (dBm) Maximum Output Power (mW) Antenna gain (dBi) Distance (cm) Power Density (mW/cm 2 ) Power Density Limit (mW/cm 2 ) 902.3 17.46 55.719 0.29 20.0 0.012 0.602 Simultaneous Transmission: Both of the Lora, Bluetooth and Wi-Fi can transmit simultaneously, the formula of calculated the MPE is: CPD1 / LPD1 + CPD2 / LPD2 + .........etc. <1 CPD: Calculation power density LPD: Limit of power density Therefore, the worst –case situation calculated as below, which the result is less than “1”. 0.00152037/1+ 0.08183713/1 + 0.01534442/1 + 0.012/1= 0.11070192 < 1 End of Test Report
Report No.: BTL-FCCP-5-2101T111 Project No.: 2101T111 Page 1 of 22 Report Version: R01 FCC Radio Test Report FCC ID: 2ATYCHMX04 Report No. : BTL-FCCP-5-2101T111 Equipment : HIPCAM Model Name : Outdoor Spotlight Camera Max Brand Name : HIPCAM Applicant : Hipcam Global LLC Address : 112 Capitol Trail, Newark, Delaware, 19711 United States Manufacturer : Goldtek Technology Co., Ltd. Address : 16F., No.166, Jian 1st Rd., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.) Radio Function : RLAN 5 GHz (U-NII 2A, U-NII 2C) FCC Rule Part(s) : FCC Part 15, Subpart E (15.407) / FCC 06-96 Measurement Procedure(s) : FCC KDB 789033 D02 General U-NII Test Procedures New Rules v02r01 FCC KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02 FCC KDB 905462 D03 UNII Clients Without Radar Detection New Rules v01r02 Date of Receipt : 2021/2/2 Date of Test : 2021/2/2 ~ 2021/3/17 Issued Date : 2021/4/20 The above equipment has been tested and found in compliance with the requirement of the above standards by BTL Inc. Prepared by : Peter Chen, Engineer Approved by : Scott Hsu , Manager BTL Inc. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan Tel: +886-2-2657-3299 Fax: +886-2-2657-3331 Web: www.newbtl.com Report No.: BTL-FCCP-5-2101T111 Project No.: 2101T111 Page 2 of 22 Report Version: R01 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-5-2101T111 Project No.: 2101T111 Page 3 of 22 Report Version: R01 CONTENTS REVISON HISTORY 4 1 EUT INFORMATION 5 1.1 EUT SPECIFICATION TABLE 5 1.2 EIRP POWER 6 2 U-NII DFS RULE REQUIREMENTS 7 2.1 WORKING MODES AND REQUIRED TEST ITEMS 7 2.2 TEST LIMITS AND RADAR SIGNAL PARAMETERS 8 3 DYNAMIC FREQUENCY SELECTION (DFS) TEST 12 3.1 DFS MEASUREMENT SYSTEM 12 3.2 CALIBRATION OF DFS DETECTION THRESHOLD LEVEL 15 3.3 DEVIATION FROM TEST STANDARD 15 4 LIST OF MEASURING EQUIPMENTS 16 5 TEST RESULTS 17 5.1 SUMMARY OF TEST RESULT 17 5.2 EST MODE: DEVICE OPERATING IN MASTER MODE. 17 5.3 CHANNEL CLOSING TRANSMISSION AND CHANNEL MOVE TIME WLAN TRAFFIC 18 5.4 NON- OCCUPANCY PERIOD 21 6 EUT TEST PHOTO 22 7 EUT PHOTOS 22 Report No.: BTL-FCCP-5-2101T111 Project No.: 2101T111 Page 4 of 22 Report Version: R01 REVISON HISTORY Report No. Version Description Issued Date BTL-FCCP-5-2101T111 R00 Original Report. 2021/4/9 BTL-FCCP-5-2101T111 R01 Revised report to address TCB’s comments. 2021/4/20 Report No.: BTL-FCCP-5-2101T111 Project No.: 2101T111 Page 5 of 22 Report Version: R01 1 EUT INFORMATION 1.1 EUT SPECIFICATION TABLE Table 1: Specification of EUT Equipment HIPCAM Model Name Outdoor Spotlight Camera Max Brand Name HIPCAM Model Difference N/A Power Source DC Voltage supplied from AC/DC adapter. Power Rating I/P: 100-240V~ 50/60Hz 0.6A Max O/P: 12.0Vdc 2.0A 24.0W Products Covered 1 * Adapter: SIMSUKIAN / SK03T-1200200Z 1 * Base Operational Mode Master Slave with radar detection Slave without radar detection Operation Band UNII-2A: 5250 MHz to 5350 MHz UNII-2C: 5470 MHz to 5725 MHz Operating Frequency UNII-2A: 5260 MHz to 5320 MHz UNII-2C: 5500 MHz to 5700 MHz Modulation OFDM Test Model Outdoor Spotlight Camera Max Sample Status Engineering Sample EUT Modification(s) N/A NOTE: (1) For a more detailed features description, please refer to the manufacturer’s specifications or the user's manual. (2) Channel List: IEEE 802.11a IEEE 802.11n (HT20) IEEE 802.11n (HT40) UNII-2A UNII-2A Channel Frequency (MHz) Channel Frequency (MHz) 52 5260 54 5270 56 5280 62 5310 60 5300 64 5320 IEEE 802.11a IEEE 802.11n (HT20) IEEE 802.11n (HT40) UNII-2C UNII-2C Channel Frequency (MHz) Channel Frequency (MHz) 100 5500 102 5510 104 5520 110 5550 108 5540 118 5590 112 5560 126 5630 116 5580 134 5670 120 5600 124 5620 128 5640 132 5660 136 5680 140 5700 Report No.: BTL-FCCP-5-2101T111 Project No.: 2101T111 Page 6 of 22 Report Version: R01 (3) Table for Filed Antenna: Ant. Manufacture Product Type Connector Frequency Range (MHz) Gain (dBi) 1 Wi-Fi Ant. PCB N/A 5250-5350 5.38 5470-5725 5.23 1.2 EIRP POWER Table 2: The Conducted Output Power and EIRP List Test Mode UNII-2A Frequency (MHz) Maximum Conducted Power (dBm) Antenna Gain (dBi) Maximum EIRP Power (dBm) Maximum EIRP Power (mW) Remark 5260 to 5320 13.49 5.38 18.87 77.09 NOTE (1) Test Mode UNII-2C Frequency (MHz) Maximu…
Text truncated - open the document above for the full version.
Report No.: BTL-FCCP-4-2101T111 Project No.: 2101T111 Page 1 of 163 Report Version: R01 FCC Radio Test Report FCC ID: 2ATYCHMX04 Report No. : BTL-FCCP-4-2101T111 Equipment : HIPCAM Model Name : Outdoor Spotlight Camera Max Brand Name : HIPCAM Applicant : Hipcam Global LLC Address : 112 Capitol Trail, Newark, Delaware, 19711 United States Manufacturer : Goldtek Technology Co., Ltd. Address : 16F., No.166, Jian 1st Rd., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.) Radio Function : RLAN 5 GHz (U-NII 1, U-NII 2A, U-NII 2C, U-NII 3) FCC Rule Part(s) : FCC Part15, Subpart E (15.407) Measurement Procedure(s) : ANSI C63.10-2013 Date of Receipt : 2021/2/2 Date of Test : 2021/2/2 ~ 2021/3/17 Issued Date : 2021/4/16 The above equipment has been tested and found in compliance with the requirement of the above standards by BTL Inc. Prepared by : Peter Chen, Engineer Approved by : Scott Hsu , Manager BTL Inc. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan Tel: +886-2-2657-3299 Fax: +886-2-2657-3331 Web: www.newbtl.com Report No.: BTL-FCCP-4-2101T111 Project No.: 2101T111 Page 2 of 163 Report Version: R01 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-4-2101T111 Project No.: 2101T111 Page 3 of 163 Report Version: R01 CONTENTS REVISON HISTORY 5 1 SUMMARY OF TEST RESULTS 6 1.1 TEST FACILITY 7 1.2 MEASUREMENT UNCERTAINTY 7 1.3 TEST ENVIRONMENT CONDITIONS 7 1.4 TABLE OF PARAMETERS OF TEST SOFTWARE SETTING 8 1.5 DUTY CYCLE 9 2 GENERAL INFORMATION 10 2.1 DESCRIPTION OF EUT 10 2.2 TEST MODES 12 2.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 13 2.4 SUPPORT UNITS 14 3 AC POWER LINE CONDUCTED EMISSIONS TEST 15 3.1 LIMIT 15 3.2 TEST PROCEDURE 15 3.3 DEVIATION FROM TEST STANDARD 15 3.4 TEST SETUP 16 3.5 TEST RESULT 16 4 RADIATED EMISSIONS TEST 17 4.1 LIMIT 17 4.2 TEST PROCEDURE 18 4.3 DEVIATION FROM TEST STANDARD 18 4.4 TEST SETUP 19 4.5 EUT OPERATING CONDITIONS 20 4.6 TEST RESULT – 30 MHZ TO 1 GHZ 20 4.7 TEST RESULT – ABOVE 1 GHZ 20 5 BANDWIDTH TEST 21 5.1 LIMIT 21 5.2 TEST PROCEDURE 21 5.3 DEVIATION FROM TEST STANDARD 21 5.4 TEST SETUP 21 5.5 EUT OPERATING CONDITIONS 21 5.6 TEST RESULT 21 6 OUTPUT POWER TEST 22 6.1 LIMIT 22 6.2 TEST PROCEDURE 22 6.3 DEVIATION FROM TEST STANDARD 22 6.4 TEST SETUP 22 6.5 EUT OPERATING CONDITIONS 22 6.6 TEST RESULT 22 7 POWER SPECTRAL DENSITY 23 7.1 LIMIT 23 7.2 TEST PROCEDURE 23 7.3 DEVIATION FROM TEST STANDARD 23 7.4 TEST SETUP 23 7.5 EUT OPERATING CONDITIONS 23 7.6 TEST RESULT 23 Report No.: BTL-FCCP-4-2101T111 Project No.: 2101T111 Page 4 of 163 Report Version: R01 8 LIST OF MEASURING EQUIPMENTS 24 9 EUT TEST PHOTO 26 10 EUT PHOTOS 26 APPENDIX A AC POWER LINE CONDUCTED EMISSIONS 27 APPENDIX B RADIATED EMISSIONS - 30 MHZ TO 1 GHZ 32 APPENDIX C RADIATED EMISSIONS - ABOVE 1 GHZ 35 APPENDIX D BANDWIDTH 126 APPENDIX E CONDUCTED OUTPUT POWER 148 APPENDIX F POWER SPECTRAL DENSITY 151 Report No.: BTL-FCCP-4-2101T111 Project No.: 2101T111 Page 5 of 163 Report Version: R01 REVISON HISTORY Report No. Version Description Issued Date BTL-FCCP-4-2101T111 R00 Original Report. 2021/4/9 BTL-FCCP-4-2101T111 R01 Revised report to address TCB’s comments. 2021/4/16 Report No.: BTL-FCCP-4-2101T111 Project No.: 2101T111 Page 6 of 163 Report Version: R01 1 SUMMARY OF TEST RESULTS Test procedures according to the technical standards. FCC Part 15, Subpart E (15.407) Standard(s) Section Description Test Result Judgement Remark 15.207 AC Power Line Conducted Emissions APPENDIX A Pass ------ 15.205 15.209 15.407(b) Radiated Emissions APPENDIX B APPENDIX C Pass ------ 15.407(a) Bandwidth APPENDIX D Pass ------ 15.407(a) Output Power APPENDIX E Pass ------ 15.407(a) Power Spectral Density APPENDIX F Pass ------ 15.203 Antenna Requirement ------ Pass ------ 15.407(c) Automatically Discontinue Transmission ------ Pass NOTE (3) NOTE: (1) ”N/A” denotes test is not applicable in this Test Report. (2) The report format version is TP.1.1.1. (3) The EUT can detect the controlling signal of ACK message transmitting from remote device and verify whether it shall resend or discontinue transmission. Report No.: BTL-FCCP-4-2101T111 Project No.: 2101T111 Page 7 of 163 Report Version: R01 1.1 TEST FACILITY The test facilities used to collect the test data…
Text truncated - open the document above for the full version.
Appendix No.: TP-2101T111-FCCP-1 APPENDIX-TEST PHOTOS Project No.: 2101T111 Page 1 of 6 AC Power Line Conducted Emissions test photos Appendix No.: TP-2101T111-FCCP-1 APPENDIX-TEST PHOTOS Project No.: 2101T111 Page 2 of 6 Radiated emissions test photos 30 MHz to 1 GHz Orthogonal Axis: X Appendix No.: TP-2101T111-FCCP-1 APPENDIX-TEST PHOTOS Project No.: 2101T111 Page 3 of 6 Radiated emissions test photos 30 MHz to 1 GHz Orthogonal Axis: Y Appendix No.: TP-2101T111-FCCP-1 APPENDIX-TEST PHOTOS Project No.: 2101T111 Page 4 of 6 Radiated emissions test photos Above 1 GHz Orthogonal Axis: X Appendix No.: TP-2101T111-FCCP-1 APPENDIX-TEST PHOTOS Project No.: 2101T111 Page 5 of 6 Radiated emissions test photos Above 1 GHz Orthogonal Axis: Y Appendix No.: TP-2101T111-FCCP-1 APPENDIX-TEST PHOTOS Project No.: 2101T111 Page 6 of 6 DFS test photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 4 | 15E | 5.75 GHz - 5.83 GHz | 10.60 mW |

HIPCAM
Equipment Class
DTS - Digital Transmission System
HIPCAM
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
HIPCAM
Equipment Class
DTS - Digital Transmission System