FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Turnils North America/
  3. 2AU29AMP15REM

2AU29AMP15REMAMP Remote

Turnils North America
AMP Remote - FCC ID 2AU29AMP15REM - Turnils North America
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
May 05, 2020
Application Purpose
Original Equipment
Date of Application
May 05, 2020
Equipment Note
AMP Remote
Frequency Range
433.92000000 - 433.92000000
Company
Turnils North America
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

AMP25B Instruction Attention -1- The motor is suitable for motorization of roller blinds, sheer shadings, roman shades, and zebra shades. Never drop, knock, drill or submerge the motor. Keep the power cable in right position as following. Important safety instructions to be read before installation. Incorrect installation can lead to serious injury and will void manufacturer’s liability and warranty. Declarations Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. -2- Safety 1. Do not expose motor to humid, damp or extreme temperature conditions. 2. Do not drill into motor. 3. Do not cut the antenna and keep it clear from metal objects. 4. Do not allow children to play with this device. 5. If power cable or connector is damaged, do not use. 6. Ensure correct crown and drive adaptor are used. 7. Ensure power cable and aerial is clear and protected from moving parts. 8. Cable routed through walls shall be properly isolated. 9. Motor is to be mounted in horizontal position only. 10. Before installation, remove unnecessary cords and disable equipment not needed for powered operation. 11. Installation and programming to be performed by a qualified professional, use or modification outside the scope of this instruction may void warranty. Features Fields of Application Specifications Following data for reference Working temperature: -10°C ~ +50°C Input Voltage: USB 5V 1A / USB 5V 2A Radio Frequency: 433.925MHz Maximum Running Time: 6 minutes Model Rated Torque (N.m) Rated Speed (rpm) Rated Power (W) AMP25B - 0.7/340.7348 AMP25B -1.1/281.1288 Charging Instructions This motor has a built in Li-ion battery pack with integrated charge management. Max power input for recharging: 5V 2A. Before first use please charge motor for 6 hours. Using 5V charger (most phones charger is 5V ) . During operation, when the motor starts, the buzzer will beep 10 times, indicating a low-voltage alarm and needs to be charged. During operation, the voltage was detected to be too low, the battery was about to run out, the battery stopped running and needed to be recharged. Rechargeable Battery Blinking red: Low battery alert Blinking green: Charging is processing Solid green: Battery has finished charging. FCC Text - text 01 Add A zoom in on the charging port P1 Button Instructions P1 button Lithium Battery Switch LED light Micro-USB Port Add visual explanation of P1 - file 02 Sheer Roller Revolve Roman shades IssuesPossible CausesSolution Battery in motor is depleted Recharge with compatible AC adaptor and check connection and positioning of solar PV panel Insufficient charging from Solar PV Panel Check connection and orientation of solar PV panel Remote control battery is dischargedReplace battery Battery is inserted incorrectly into remote control Check battery polarity The motor has no responseRadio interference / shielding Ensure remote control is positioned away from metal objects and the aerial on motor receiver is kept straight away from metal Receiver distance is too far from Remote Control Move remote control to a closer position Power failureCheck power supply to motor is connected and active Incorrect wiring Check that wiring is connected correctly (refer to motor installation instructions) Motor beeps 10 times when in use Battery voltage is low / PV (solar panel issue) Recharge with AC adaptor or check connection and positioning of solar PV panel Always reserve an individual channel for programming functions SYSTEM BEST PRACTICE - Provide an extra 15 channel remote in your multi-motor projects that provides individual control for each motor for programming purposes Place all other motors into sleep mode (ref to P1 button instructions) Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. Roller Cellular Standard Sheer Cellular Skylight Revolve Tilt-Only Venetian Roman Cannot program a single motor (multiple motors respond) Multiple motors are paired to the same channel. SettingsSteps 1PairingP1 (hold down for 2s) > Stop (hold down for 2s) 2Switch Rotating DirectionUp + Down (hold down for 2s) 3Setting Upper & Lower Limits 4Add / Remove Favorite PositionP2 > Stop > Stop 5Roller Mode & Sheer Mode SwitchUp + Down (hold down for 5s) > Stop 6Adjust Limits 7Pair / Unpair Additional EmitterP2 (existing) > P2 (existing) > P2 (new) 8Speed Regulation Upper Limit: Up (hold down for 2s) > Up + Stop (hold down for 2s) Upper Limit: Up + Stop (hold down for 5s) > Up or Down > Up + Stop (hold down for 2s) Acceleration: P2 > Up > Up Lower Limit: Down (hold down for 2s) > Down + Stop (hold down for 2s) Lower Limit: Down + Stop (hold down for 5s) > Up or Down > Down + Stop (hold down for 2s) Decelaration: P2 > Down > Down AMP Remote Declarations Fields of Application Quick Index Safety Instructions Troubleshooting Button Instructions Replace/Install CR2450 Battery Advanced Setting - Disable Limit Setting 1. Do not expose motor to humid, damp, or extreme temperature conditions. 2. Do not drill into motor. 3. Do not cut the antenna. Keep it clear from metal objects. 4. Do not allow children to play with this device. 5. If the power cable or connector is damaged, do not use. 6. Ensure the correct crown and drive adaptor are used. 7. Ensure the power cable and aerial is clear and protected from moving parts. 8. Cable routed through walls should be properly isolated. 9. Motor is to be mounted in horizontal position only. 10. Before installation, remove unnecessary cords and disable equipment not needed for powered operation. 11. Installation and programming should be performed by a qualified professional. Use or modification outside the scope of these instructions may void warranty. U.S. Radio Frequency FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference r…

Text truncated - open the document above for the full version.

Cover Letter(s)

&RPSDQ\7XUQLOV1RUWK$PHULFD $GG6DWHOOLWH%OYG6XLWH%XIRUG*HRUJLD8QLWHG6WDWHV 7HO770-995-2222 )D[  (PDLOSKRHQL[OLQ#WXUQLOVFRP DECLARATION Dear Sir or Madam: :H7XUQLOV1RUWK$PHULFD KHUHE\GHFODUHWKDWSURGXFWQDPHAMP Remote  PRGHOQDPH AMP-15C-RemoteAMP-15C-Dual-Remote, FCC ID: 2AU29AMP15REM.) AMP-15C-RemoteDQGAMP-15C-Dual RemoteDUHHOHFWULFDOO\ LGHQWLFDOZLWK WKH3&% G HVLJQ FRPSRQHQWVDQGDSSHDUDQFH 3OHDVHFRQWDFWPH LIWKHUHLVQHHGIRUDQ\DGGLWLR QDOFODULILFDWLRQRULQIRUPDWLRQ %HVW5HJDUGV 6LJQDWXUH 3ULQW1DPH3KRHQL[/LQ 7LWOH3URMHFW0DQDJHU )('(5$/&20081,&$7,216&200,66,216 $XWKRUL]DWLRQDQG(YDOXDWLRQ'LYLVLRQ 2DNODQG0LOOV5RDG &ROXPELD0' 7KHGLIIHUHQFHVRIWKHPDUHDVIROORZV  Software: different software, but different software does not affect RF power and RF parameters PRGHOQDPH

Cover Letter(s)

Company: Turnils North America Add: 1750 Satellite Blvd, Suite 10 0, Buford, Georgia, 30518 United States Tel: 770-995-2222 Fax: 770-995-2210 E-mail: [email protected] m FCC Confidential Authorization Date: 2020-03-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AU29AMP15REM To: whom it may concern, In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Turnils North America hereby requests long-term confidential treatment of information accompanying this application as outlined below: Block Diagram Schematics Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Typed or Printed Name: Phoenix Lin Title: Project Manager

External Photos

QA-FR-170-B Company: Turnils North America Add: 1 750 Satellite Blvd, Suite 100, Buford, Georgia, 30518 United States Tel: 770-995-2222 Fax: 770-995-2210 FCC Authorization Date: 2020-03-02 FE DERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Turnils North America, the undersigned, Hereby authorizes Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Typed or Printed Name: Phoenix Lin Title: Project Manager

External Photos

EXHIBIT A - EUT EXTERNAL PHOTOGRAPHS

ID Label/Location Info

PN: 62101010 BI-DIRECTIONAL AMP-15C-Remote RF:433.92MHz FCC ID: 2AU29AMP15REM IC: 25624-AMP15REM M ADE IN PRC AMP Remote

Internal Photos

EXHIBIT B- EUT INTERNAL PHOTOGRAPHS Antenna

Test Report

Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 15.231 TEST REPORT For Turnils North America 1750 Satellite Blvd, Suite 100, Buford, Georgia, 30518 United States FCC ID: 2AU29AMP15REM Report Type: Original Report Product Type: AMP Remote Test Engineer: Lee Li Report Number: RSHA200302002-00B Report Date: 2020-04-03 Reviewed By: Oscar Ye EMC Manager Prepared By: Bay Area Compliance Laboratories Corp. (Kunshan) No.248 Chenghu Road, Kunshan, Jiangsu province, China Tel: +86-0512-86175000 Fax: +86-0512-88934268 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA200302002-00B FCC Part 15.231 Page 2 of 19 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 3 OBJECTIVE ................................................................................................................................................................... 3 TEST METHODOLOGY .................................................................................................................................................. 3 MEASUREMENT UNCERTAINTY .................................................................................................................................... 4 TEST FACILITY ............................................................................................................................................................. 4 SYSTEM TEST CONFIGURATION .......................................................................................................................... 5 JUSTIFICATION ............................................................................................................................................................. 5 EUT EXERCISE SOFTWARE .......................................................................................................................................... 5 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 5 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 5 EXTERNAL I/O CABLE .................................................................................................................................................. 5 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 6 SUMMARY OF TEST RESULTS ............................................................................................................................... 7 TEST EQUIPMENT LIST ........................................................................................................................................... 8 FCC§15.203 - ANTENNA REQUIREMENT .............................................................................................................. 9 APPLICABLE STANDARD .............................................................................................................................................. 9 ANTENNA CONNECTED CONSTRUCTION ...................................................................................................................... 9 FCC §15.205, §15.209, §15.231 (B) - RADIATED EMISSIONS ............................................................................. 10 APPLICABLE STANDARD ............................................................................................................................................ 10 EUT SETUP ................................................................................................................................................................ 11 EMI TEST RECEIVER SETUP ....................................................................................................................................... 12 TEST PROCEDURE ...................................................................................................................................................... 12 CORRECTED AMPLITUDE & MARGIN CALCULATION ................................................................................................. 12 TEST RESULTS SUMMARY .......................................................................................................................................... 12 TEST DATA ................................................................................................................................................................ 12 FCC §15.231(A) (1) - DEACTIVATION TESTING ................................................................................................. 16 APPLICABLE STANDARD ............................................................................................................................................ 16 TEST PROCEDURE ...................................................................................................................................................... 16 TEST DATA ................................................................................................................................................................ 16 FCC §15.231(C) - 20DB EMISSION BANDWIDTH TESTING ............................................................................. 18 APPLICABLE STANDARD ...................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT C- TEST SETUP PHOTOGRAPHS Radiated Emissions (Below 1GHz) Radiated Emissions (Above 1GHz)

Contact Information

Applicant

Phoenix Lin(Senior Project Manager)
[email protected]770-878-2281Fax: 770-995-2210

Test Firm

Bay Area Compliance Laboratories Corp. (Kunshan)Mr. John Chan
[email protected]+86 0512 86175000

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Turnils North America

2AU29AMPSNHUBV1

Smart Hub

Jan 18, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
2AU29AMPSNHUBFV1

Smith & Noble Smart Hub

Jan 18, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
2AU29AMPRFWIFIUSBV3

AMP Bridge

Jan 16, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
DC Tubular Motor with built-in RF control - FCC ID 2AU29AMP28BDCV2 - Turnils North America
2AU29AMP28BDCV2

DC Tubular Motor with built-in RF control

Dec 16, 2023

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
DC Tubular Motor for Narrow Shades - FCC ID 2AU29AMP25BDCV3 - Turnils North America
2AU29AMP25BDCV3

DC Tubular Motor for Narrow Shades

Jul 09, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter