Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Working temperature: -10º C ~ +50º C Radio Frequency: 433.925 MHz Input Voltage: USB 5V 1A / USB 5V 2A Maximum Running Time: 6 minutes Model Rated Torque (N.m) Rated Speed (RPM) Rated Power (W) AMP25B - 0.7/34 0.7 34 8 AMP25B - 1.1/28 1.1 28 10 Settings Steps 1 Pairing P1 (hold down for 2s) > Stop (hold down for 2s) 2 Switch Rotating Direction Up + Down (hold down for 2s) 3 Setting Upper & Lower Limits4 Add / Remove Favorite Position P2 > Stop > Stop 5 Roller Mode & Sheer Mode Switch Up + Down (hold down for 5s) > Stop 6 Adjust Limits7 Pair / Unpair Additional Emitter P2 (existing) > P2 (existing) > P2 (new) 8 Speed Regulation Issues Possible Causes Solution Built in battery is depleted Recharge with compatible AC adaptor and check connection and positioning of solar PV panel Insufficient charging from Solar PV Panel Check connection and orientation of solar PV panel Remote control battery is discharged Replace batteryBattery is inserted incorrectly into remote control Check battery polarity The motor is not responding Radio interference / shielding Ensure remote control is positioned away from metal objects and the aerial on motor receiver is kept straight away from metal Receiver is far away from Remote Control Move remote control to a closer position Power failure Check power supply to motor is connected and active Incorrect wiring Check that wiring is connected correctly (refer to motor installation instructions) Motor beeps 10 times when in use Battery voltage is low / PV (solar panel issue) Recharge with AC adaptor or check connection and positioning of solar PV panelAlways reserve an individual channel for programming functionsSYSTEM BEST PRACTICE - Provide an extra 15 channel remote in your multi-motor projects that provides individual control for each motor for programming purposesPlace all other motors into sleep mode (ref to P1 button instructions) The motor is suitable for motorization of roller shades, sheer shades, roman shades, and revolve shades. Do not dispose of in general waste.Please recycle batteries and damaged electrical products appropriately. Roller Sheer Revolve Roman Upper Limit: Up (hold down for 2s) > Up + Stop (hold down for 2s) Upper Limit: Up + Stop (hold down for 5s) > Up or Down > Up + Stop (hold down for 2s) Cannot program a single motor (multiple motors respond) Multiple motors are paired to the same channel. Acceleration: P2 > Up > Up Lower Limit: Down (hold down for 2s) > Down + Stop (hold down for 2s) Lower Limit: Down + Stop (hold down for 5s) > Up or Down > Down + Stop (hold down for 2s) Decelaration: P2 > Down > Down 1234 ×××× 5 Test Motor 1 2 6 10 14 Activate Pairing ModeSleep ModeReverse DirectionReset To Factory Settings Approx. 2 sec. Happening as you press for 2 secondsHappening as you press for 1 secondHappening as you press for 6 secondsHappening as you press for 10 secondsHappening as you press for 14 seconds when released when released when releasedwhen released when released Approx. 6 sec.Approx. 10 sec.Approx. 14 sec. Until Shade:Until Shade: Motor Response:Motor Response:Motor Response: Until Shade: Until Shade: Motor Response: Beep x1 Beep x2 Jog x3 Jog x4 Jog x1Jog x2 Beep x3 Beep x4 Less than 1 sec.Press P1Press P1Press P1Press P1Press P1 Motor Response: Wakes & Runs AMP25B Declarations Fields of ApplicationSpecifications Quick Index AttentionSafety Instructions Troubleshooting Charging InstructionsRechargeable BatteryP1 Button Instructions This motor has a built in Li-ion battery pack with integrated charge management.Max power input for recharging: 5V 2A.Before first use please charge motor for 6 hours using a 5V charger.During operation, when the motor starts, the buzzer will beep 10 times, indicating a low-voltage alarm and needs to be charged.During operation, if the voltage is detected to be too low, the battery stops running and needs to be recharged. Micro-USB Port Blinking red: Low battery alert Blinking green: Charging in process Solid green: Battery has finished charging Never drop, knock, drill or submerge the motor. Keep the power cable in the proper position as shown below.Read all safety instructions before installation.Incorrect installation can lead to serious injury and will void manufacturer’s liability and warranty.1. Do not expose motor to humid, damp, or extreme temperature conditions.2. Do not drill into motor.3. Do not cut the antenna. Keep it clear from metal objects.4. Do not allow children to play with this device.5. If the power cable or connector is damaged, do not use.6. Ensure the correct crown and drive adaptor are used.7. Ensure the power cable and aerial is clear and protected from moving parts.8. Cable routed through walls should be properly isolated.9. Motor is to be mounted in horizontal position only.10. Before installation, remove unnecessary cords and disable equipment not needed for powered operation.11. Installation and programming should be performed by a qualified professional. Use or modification outside the scope of these instructions may void warranty. U.S. Radio Frequency FCC ComplianceThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be det…
Text truncated - open the document above for the full version.
&RPSDQ\7XUQLOV1RUWK$PHULFD $GG6DWHOOLWH%OYG6XLWH%XIRUG*HRUJLD8QLWHG6WDWHV 7HO )D[ (PDLOSKRHQL[OLQ#WXUQLOVFRP DECLARATION Dear Sir or Madam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
QA-FR-170-B Company: Turnils North America Add: 1 750 Satellite Blvd, Suite 100, Buford, Georgia, 30518 United States Tel: (770) 995-2222 3032 Fax: 770-995-2210 FCC Authorization Date: 2019-11-29 FE DERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Turnils North America, the undersigned, Hereby authorizes Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Typed or Printed Name: Phoenix Lin Title: Project Manager
Company: Turnils North America Add: 1750 Satellite Blvd, Su ite 100, Buford, Georgia, 30518 United States Tel: (770) 995-2222 3032 Fax: 770-995-2210 E-mail: [email protected] FCC Confidential Authorization Date: 2019-11-29 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AU29AMP25B0711 To: whom it may concern, In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Turnils North America hereby requests long-term confidential treatment of information accompanying this application as outlined below: Block Diagram Schematics Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Typed or Printed Name: Phoenix Lin Title: Project Manager
EXHIBIT A - EUT EXTERNAL PHOTOGRAPHS
Model: AMP25B-1.1/28 AMP25B-1.1/28 DC Tubular Motor & rechargeable battery FCC ID: 2AU29AMP25B0711 IC: 25624-AMP25B0711 USB DC 5V 2A .1Nm 281.1Nm1 10W Ø25 2200mAh IP20 BI-DIRECTIONAL MADE IN PRC PN: 62003000 Model: AMP25B-0.7/34 BI-DIRECTIONAL MADE IN PRC AMP25B-0.7/34 USB DC 5V 2A 0.7Nm 34r/min 8W Ø25 2200mAh IP20 DC Tubular Motor & rechargeable battery FCC ID: 2AU29AMP25B0711 IC: 25624-AMP25B0711 PN: 62001000
EXHIBIT B- EUT INTERNAL PHOTOGRAPHS Antenna
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 15.231 TEST REPORT For Turnils North America 1750 Satellite Blvd, Suite 100, Buford, Georgia, 30518 United States FCC ID: 2AU29AMP25B0711 Report Type: Original Report Product Type: DC Tubular Motor & rechargeable battery Test Engineer: CK Huang Report Number: RSHA191129014-00A Report Date: 2020-01-02 Reviewed By: Oscar Ye EMC Manager Prepared By: Bay Area Compliance Laboratories Corp. (Kunshan) No.248 Chenghu Road, Kunshan, Jiangsu province, China Tel: +86-0512-86175000 Fax: +86-0512-88934268 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA191129014-00A FCC Part 15.231 Page 2 of 25 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 3 OBJECTIVE ................................................................................................................................................................... 3 TEST METHODOLOGY .................................................................................................................................................. 3 MEASUREMENT UNCERTAINTY .................................................................................................................................... 4 TEST FACILITY ............................................................................................................................................................. 4 SYSTEM TEST CONFIGURATION .......................................................................................................................... 5 JUSTIFICATION ............................................................................................................................................................. 5 EUT EXERCISE SOFTWARE .......................................................................................................................................... 5 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 5 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 5 EXTERNAL I/O CABLE .................................................................................................................................................. 5 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 6 SUMMARY OF TEST RESULTS ............................................................................................................................... 8 TEST EQUIPMENT LIST ........................................................................................................................................... 9 FCC§15.203 - ANTENNA REQUIREMENT ............................................................................................................ 10 APPLICABLE STANDARD ............................................................................................................................................ 10 ANTENNA CONNECTED CONSTRUCTION .................................................................................................................... 10 FCC §15.207 (A) - AC LINE CONDUCTED EMISSIONS ..................................................................................... 11 APPLICABLE STANDARD ............................................................................................................................................ 11 EUT SETUP ................................................................................................................................................................ 11 EMI TEST RECEIVER SETUP ....................................................................................................................................... 11 TEST PROCEDURE ...................................................................................................................................................... 11 FACTOR & OVER LIMIT CALCULATION ...................................................................................................................... 12 TEST RESULTS SUMMARY .......................................................................................................................................... 12 TEST DATA ................................................................................................................................................................ 12 FCC §15.205, §15.209, §15.231 (B) - RADIATED EMISSIONS ............................................................................. 15 APPLICABLE STANDARD ............................................................................................................................................ 15 EUT SETUP ................................................................................................................................................................ 16 EMI TEST RECEIVER SETUP ....................................................................................................................................... 17 TEST PROCEDURE ...................................................................................................................................................... 17 CORR…
Text truncated - open the document above for the full version.
EXHIBIT C- TEST SETUP PHOTOGRAPHS Conducted Emissions (Front View) Conducted Emissions (Side View) Radiated Emissions (Below 1GHz) Radiated Emissions (Above 1GHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.925 MHz - 433.925 MHz | - |
Smart Hub
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterSmith & Noble Smart Hub
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterAMP Bridge
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
DC Tubular Motor with built-in RF control
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
DC Tubular Motor for Narrow Shades
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter