FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Turnils North America/
  3. 2AU29AMPTILT1012

2AU29AMPTILT1012DC Tilt Motor for Horizontal Blinds

Turnils North America
DC Tilt Motor for Horizontal Blinds - FCC ID 2AU29AMPTILT1012 - Turnils North America
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Feb 27, 2020
Application Purpose
Original Equipment
Date of Application
Feb 27, 2020
Equipment Note
DC Tilt Motor for Horizontal Blinds
Frequency Range
433.92500000 - 433.92500000
Company
Turnils North America
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Parameters(More models and parameters are subject to the nameplate) -10 55 Type Rated Torque(N.m) Rated Voltage(V) DV50CE/S-1N/12r 1N.m 12RPM 12V Rated Speed(RPM) 1A 12W 433.925MHz Rated Current(A) Rated Power(W) Emission Frequency(MHz) One motor maximum can store 10 channels,over 10 channels,if still need add new channels,it will be repeating covered in turn from second channel. Product features Built-in Receiver Jog & Tilt Switch Direction Program Button Unpair Single Emitter Electronic Limit Memorized Settings Preferred Stop Position Stall Protection Low Power Consumption, Suitable for External Battery Power Operating temperature NoteThe motor DV50CE/S can be charged by both the power adapter DC240(I/J/K) or the 12V supply electricity. DC240(I/J/K) P2 M P2 Lithium Cell 3V P2 Up button Stop button Down button Setting button Motor setting button(P1) 1. Not operating under low voltage motors: Motor stop running when the supply voltage is lower than 8.5V,and it will restart again when the voltage is greater than 8.5V. 2. Operating The valid interval of the emitter button is 10s,the emitter will quit the set after 10s; The motor will run for hint,please do the next step after the hint. 3. Set limit position After the up/down limit position setting,and the up/down limit position can’t at the same position; After limit setting,with power off and memory function; Into the match-code status 2 minutes later, it will quit out the setting limits status automatically; It will delete every memory and restore the factory settings. 4. When the motor running without any operation, the maximum running time is 6 minutes,it will stop automatically. 5. If the emitter lost,please setting up again with new emitter. & 2, Clear preferred stop positionP2StopStop P2 P2P2 P2 Add emitter is ok P2P2 P2 Delete emitter is ok The motor running speed is improved Run for hint x2 Adjust the new up limit + The new up limit is ok The new down limit is ok or Press 1sPress 2s Up+DownStop Note: In the jog-move mode,short press up/down button 2s to loosen,the motor is jog-move to run;If long press more than 2s, the motor run continuously,release the button, the motor stops running;In the continuous moving mode,long press up/down button, the motor runs continuously, release the button, the motor stops running. Press 5sPress 1s Run for hint x1 + Method three Add emitter is ok Method one P2 P2 P2 P2 P2 P2 P2P2 Add emitter is ok Method two P2 P2 Stop Up+StopUp/DownUp+Stop Down+StopUp/DownDown+Stop 1, Fine-tuning the up limit position 2, Fine-tuning the down limit position Run for hint x2 Stop Run for hint x1T<10s loosen P1 Setting up is ok Press 2sPress 2s Press 1s Press 2s + Run for hint x1 The curtain run downward Successful change the direction 1, Set up limit 2, Set down limit UpUp+Stop DownStop+Down Note: If the trip setting is not completed, the limit setting mode is exited,if you already have a limit, you will continue to use the pre-set limit;After setting up the up and down limit into user mode. Press 5s Press 1sPress 2sPress 5s + Run for hint x1 Run for hint x2 Adjust the new down limit Run for hint x1 Enter into fine-tune limit mode Enter into fine-tune limit mode + or + UpUp+Down P2StopStop Preferred stop posi- tion is ok Press 1sPress 1sPress 1s P2 1, Set preferred stop position After the up limit and down limit setting, you can set preferred stop position between them as the half open position. Stop Note: If not within 10s to be on the code emitter or no legal STOP button code, 10s limit to time, will automatically exit the setting up mode;After the success of the code will delete the original limit settings and motor running mode speed settings, restore the factory value. Note: After entering fine-tuning mode, will not delete the original preferred stop position;If no button operation within 2 minutes, 2 minutes to the limit, the motor will be prompted to turn and automatically exit the limit fine-tuning mode; After fine-tuning the up/down limit position can not be in the same position. If you need to reverse the rotateon of the motor controlled by the emitter,please run the reverse of direction setting Note: After the success of the reversing,retain all motor original settings. Jog-move mode Continuous moving mode Run for hint x1 Run for hint x1 Run for hint x1 Run for hint x2 Run for hint x2 Note: Continuous moving mode,long press stop button,the curtain run directly from the current position to preferred stop position(Apply to the shade); Jog-move mode,long press stop button,The motor will first run to the down limit position,then run to preferred stop position(Apply to venetian blinds). Note: If motor without run for hint,indicating that the motor has reached the maximum or minimum value;The motor speed in continuous moving mode has 3 levels, 10r/min, 15r/min, 20r/min, The factory defaults to the slowest speed. The motor running speed is reduced P2Up/DownUp/Down Press 1sPress 1s Run for hint x1Run for hint x1Run for hint x1 Press 1s Press 1sPress 1s Run for hint x1Run for hint x1Run for hint x2 Run for hint x1Run for hint x1Run for hint x2 Run for hint x1Run for hint x1Run for hint x2 Run for hint x1Run for hint x2 Press 1s Press 1s Run for hint x1 Press 1s Press 1sPress 1s Run for hint x1Run for hint x2 Press 1sPress 1s Run for hint x1Run for hint x2 Press 1sPress 1s Press 1sPress 2sPress 1s P2 Clear preferred stop position is ok loosen P1 Press 2sPress 2s Note: Emitter is the one already matched code, while emitter has not;After the success of add emitter to retain all the settings of the original motor. Note: are all of the code emitters,this method only can delete the emitter not the emitter ;After the success of delete emitter to retain allthe settings of the original motor(The limit is reserved for previous settings). Note: After the success of the reversing,retain all motor original settings. Run for hint x4 Long Press P1 Loosen P1 Long Press P1 Loosen P1 Long Press P1 Loosen P1 Note:Motor into the shiel…

Text truncated - open the document above for the full version.

Cover Letter(s)

QA-FR-170-B Company: Turnils North America Add: 1 750 Satellite Blvd, Suite 100, Buford, Georgia, 30518 United States Tel: (770) 995-2222 3032 Fax: 770-995-2210 FCC Authorization Date: 2019-11-29 FE DERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Turnils North America, the undersigned, Hereby authorizes Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Typed or Printed Name: Phoenix Lin Title: Project Manager

Cover Letter(s)

Company: Turnils North America Add: 1750 Satellite Blvd, Su ite 100, Buford, Georgia, 30518 United States Tel: (770) 995-2222 3032 Fax: 770-995-2210 E-mail: [email protected] FCC Confidential Authorization Date: 2019-11-29 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AU29AMPTILT1012 To: whom it may concern, In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Turnils North America hereby requests long-term confidential treatment of information accompanying this application as outlined below: Block Diagram Schematics Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature: Typed or Printed Name: Phoenix Lin Title: Project Manager

External Photos

EXHIBIT A - EUT EXTERNAL PHOTOGRAPHS

Internal Photos

EXHIBIT B - EUT INTERNAL PHOTOGRAPHS Antenna

Test Report

Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 15.231 TEST REPORT For Turnils North America 1750 Satellite Blvd, Suite 100, Buford, Georgia, 30518 United States FCC ID: 2AU29AMPTILT1012 Report Type: Original Report Product Type: DC Tilt Motor for Horizontal Blinds Test Engineer: Stone Zhan g Report Number: RSHA191129017-00A Report Date: 2019-12-12 Reviewed By: Oscar Ye EMC Manager Prepared By: Bay Area Compliance Laboratories Corp. (Kunshan) No.248 Chenghu Road, Kunshan, Jiangsu province, China Tel: +86-0512-86175000 Fax: +86-0512-88934268 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RSHA191129017-00A FCC Part 15.231 Page 2 of 25 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 3 OBJECTIVE ................................................................................................................................................................... 3 TEST METHODOLOGY .................................................................................................................................................. 3 MEASUREMENT UNCERTAINTY .................................................................................................................................... 4 TEST FACILITY ............................................................................................................................................................. 4 SYSTEM TEST CONFIGURATION .......................................................................................................................... 5 JUSTIFICATION ............................................................................................................................................................. 5 EUT EXERCISE SOFTWARE .......................................................................................................................................... 5 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 5 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 5 EXTERNAL I/O CABLE .................................................................................................................................................. 5 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 6 SUMMARY OF TEST RESULTS ............................................................................................................................... 8 TEST EQUIPMENT LIST ........................................................................................................................................... 9 FCC§15.203 - ANTENNA REQUIREMENT ............................................................................................................ 10 APPLICABLE STANDARD ............................................................................................................................................ 10 ANTENNA CONNECTED CONSTRUCTION .................................................................................................................... 10 FCC §15.207 (A) - AC LINE CONDUCTED EMISSIONS ..................................................................................... 11 APPLICABLE STANDARD ............................................................................................................................................ 11 EUT SETUP ................................................................................................................................................................ 11 EMI TEST RECEIVER SETUP ....................................................................................................................................... 11 TEST PROCEDURE ...................................................................................................................................................... 11 FACTOR & OVER LIMIT CALCULATION ...................................................................................................................... 12 TEST RESULTS SUMMARY .......................................................................................................................................... 12 TEST DATA ................................................................................................................................................................ 12 FCC §15.205, §15.209, §15.231 (B) - RADIATED EMISSIONS ............................................................................. 15 APPLICABLE STANDARD ............................................................................................................................................ 15 EUT SETUP ................................................................................................................................................................ 16 EMI TEST RECEIVER SETUP ....................................................................................................................................... 17 TEST PROCEDURE ...................................................................................................................................................... 17 COR…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT C - TEST SETUP PHOTOGRAPHS Conducted Emissions (Front View) Conducted Emissions (Side View) Radiated Emissions (Below 1GHz) Radiated Emissions (Above 1GHz)

Contact Information

Applicant

Phoenix Lin(Senior Project Manager)
[email protected]770-878-2281Fax: 770-995-2210

Test Firm

Bay Area Compliance Laboratories Corp. (Kunshan)Mr. John Chan
[email protected]+86 0512 86175000

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.925 MHz - 433.925 MHz-
Confidentiality
Long Term

Other Applications from Turnils North America

2AU29AMPSNHUBV1

Smart Hub

Jan 18, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
2AU29AMPSNHUBFV1

Smith & Noble Smart Hub

Jan 18, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
2AU29AMPRFWIFIUSBV3

AMP Bridge

Jan 16, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
DC Tubular Motor with built-in RF control - FCC ID 2AU29AMP28BDCV2 - Turnils North America
2AU29AMP28BDCV2

DC Tubular Motor with built-in RF control

Dec 16, 2023

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
DC Tubular Motor for Narrow Shades - FCC ID 2AU29AMP25BDCV3 - Turnils North America
2AU29AMP25BDCV3

DC Tubular Motor for Narrow Shades

Jul 09, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter