
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
AMP25B Instruction Attention -1- The motor is suitable for motorization of roller blinds, sheer shadings, roman shades, and zebra shades. Never drop, knock, drill or submerge the motor. Keep the power cable in right position as following. Important safety instructions to be read before installation. Incorrect installation can lead to serious injury and will void manufacturer’s liability and warranty. Declarations Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. -2- Safety 1. Do not expose motor to humid, damp or extreme temperature conditions. 2. Do not drill into motor. 3. Do not cut the antenna and keep it clear from metal objects. 4. Do not allow children to play with this device. 5. If power cable or connector is damaged, do not use. 6. Ensure correct crown and drive adaptor are used. 7. Ensure power cable and aerial is clear and protected from moving parts. 8. Cable routed through walls shall be properly isolated. 9. Motor is to be mounted in horizontal position only. 10. Before installation, remove unnecessary cords and disable equipment not needed for powered operation. 11. Installation and programming to be performed by a qualified professional, use or modification outside the scope of this instruction may void warranty. Features Fields of Application Specifications Following data for reference Working temperature: -10°C ~ +50°C Input Voltage: USB 5V 1A / USB 5V 2A Radio Frequency: 433.925MHz Maximum Running Time: 6 minutes Model Rated Torque (N.m) Rated Speed (rpm) Rated Power (W) AMP25B - 0.7/340.7348 AMP25B -1.1/281.1288 Charging Instructions This motor has a built in Li-ion battery pack with integrated charge management. Max power input for recharging: 5V 2A. Before first use please charge motor for 6 hours. Using 5V charger (most phones charger is 5V ) . During operation, when the motor starts, the buzzer will beep 10 times, indicating a low-voltage alarm and needs to be charged. During operation, the voltage was detected to be too low, the battery was about to run out, the battery stopped running and needed to be recharged. Rechargeable Battery Blinking red: Low battery alert Blinking green: Charging is processing Solid green: Battery has finished charging. FCC Text - text 01 Add A zoom in on the charging port P1 Button Instructions P1 button Lithium Battery Switch LED light Micro-USB Port Add visual explanation of P1 - file 02 Sheer Roller Revolve Roman shades IssuesPossible CausesSolution Battery in motor is depleted Recharge with compatible AC adaptor and check connection and positioning of solar PV panel Insufficient charging from Solar PV Panel Check connection and orientation of solar PV panel Wall switch battery is dischargedReplace battery Battery is inserted incorrectly into wall switch Check battery polarity The motor has no responseRadio interference / shielding Ensure wall switch and the antenna on the motor are positioned away from metal objects Receiver distance is too far from wall switch Move wall switch to a closer position Power failureCheck power supply to motor is connected and active Incorrect wiring Check that wiring is connected correctly (refer to motor installation instructions) Motor beeps 10 times when in use Battery voltage is low / PV (solar panel issue) Recharge with AC adapter or check connection and positioning of solar PV panel Always reserve an individual channel for programming functions SYSTEM BEST PRACTICE - Provide an extra 15 channel remote in your multi-motor projects that provides individual control for each motor for programming purposes Place all other motors into sleep mode (Press “P1” button (about 6 sec) on the motor head until motor jog x2 and beep x2). Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. Roller Cellular/Honeycomb Standard Cellular/Honeycomb Skylight SheerBanded Tilt-Only Horizontal Narrow Width Roman Cannot program a single motor (multiple motors respond) Multiple motors are paired to the same channel. SettingsSteps 1PairingP1 (hold down for 2s) > Stop (hold down for 2s) 2Switch Rotating DirectionUp + Down (hold down for 2s) 3Setting Upper & Lower Limits 4Add / Remove Favorite PositionP2 > Stop > Stop 5Roller Mode & Sheer Mode SwitchUp + Down (hold down for 5s) > Stop 6Adjust Limits 7Pair / Unpair Additional EmitterP2 (existing) > P2 (existing) > P2 (new) 8Speed Regulation Upper Limit: Up (hold down for 2s) > Up + Stop (hold down for 2s) Upper Limit: Up + Stop (hold down for 5s) > Up or Down > Up + Stop (hold down for 2s) Acceleration: P2 > Up > Up Lower Limit: Down (hold down for 2s) > Down + Stop (hold down for 2s) Lower Limit: Down + Stop (hold down for 5s) > Up or Down > Down + Stop (hold down for 2s) Deceleration: P2 > Down > Down AMP ™ Surface Mounted Wall Switch Declarations Fields of Application Quick Index Safety Instructions Troubleshooting Button Instructions Replace/Install CR2430 Battery Advanced Setting - Disable Limit Setting 1. Do not expose motor to humid, damp, or extreme temperature conditions. 2. Do not drill into motor. 3. Do not cut the antenna. Keep it clear from metal objects. 4. Do not allow children to play with this device. 5. If the power cable or connector is damaged, do not use. 6. Ensure the correct crown and drive adaptor are used. 7. Ensure the power cable and aerial is clear and protected from moving parts. 8. Cable routed through walls should be properly isolated. 9. Motor is to be mounted in horizontal position only. 10. Before installation, remove unnecessary cords and disable equipment not needed for powered operation. 11. Installation and programming should be performed by a qualified professional. Use or modification outside the scope of these instructions may void warranty. U.S. Radio Frequency FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interfe…
Text truncated - open the document above for the full version.
Turnils North America 1750 Satellite Blvd, Suite 100, Buford, Georgia 30518, United States --------------------------------------------------------------------------------------------------------------------- Date: 2022-11-22 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AU29AMPWSSUV2 Confidentiality Request To whom it may concern, Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of the information accompanying this application as outlined below: ☒ Block Diagram ☐ Tune-Up Information ☒ Operational Description ☐ Security Information ☒ Schematics ☐ Software Defined Radio (SDR) Information ☐ Parts List The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Turnils North America ------------------------------- Richard Allgood /Project Manager
Turnils North America 1750 Satellite Blvd, Suite 100, Buford, Georgia 30518, United States -------------------------------------------------------------------------------- (FCC ID:2AU29AMPWSSUV2) POWER OF ATTORNEY DATE: 2022-11-22 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Testing Group (Shenzhen) Co., Ltd. Jandy So on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Testing Group (Shenzhen) Co., Ltd. Jandy So on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, Turnils North America are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Turnils North America ------------------------------- Richard Allgood/Project Manager
Reference No.: WTN21X10116492W-1 Page 2 of 11 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn EXHIBIT 2 - EUT EXTERNAL PHOTOGRAPHS EUT View 1 EUT View 2 Reference No.: WTN21X10116492W-1 Page 3 of 11 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn EUT View 3 EUT View 4 Reference No.: WTN21X10116492W-1 Page 4 of 11 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn EUT View 5 EUT View 6 Reference No.: WTN21X10116492W-1 Page 5 of 11 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn EUT View 7
Reference No.: WTN21X10116492W-1 Page 1 of 11 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn ANNEX EXHIBIT 1 - PRODUCT LABELING Proposed FCC ID Label Format Specifications: The label shall be securely affixed to a permanently attached part of the device, in a location where it is visible or easily accessible to the user, and shall not be readily detachable. The label shall be sufficiently durable to remain fully legible and intact on the device in all normal conditions of use throughout the device’s expected lifetime. Proposed Label Location on EUT FCC ID Label Location
Reference No.: WTN21X10116492W-1 Page 6 of 11 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn EXHIBIT 3 - EUT INTERNAL PHOTOGRAPHS EUT Housing and Board View 1 EUT Housing and Board View 2 Reference No.: WTN21X10116492W-1 Page 7 of 11 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Solder Board-Component View 1 Solder Board-Component View 2 Reference No.: WTN21X10116492W-1 Page 8 of 11 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Solder Board-Component View 3 Solder Board-Component View 4 Reference No.: WTN21X10116492W-1 Page 9 of 11 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Antenna View
Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 1 of 24 TEST REPORT Reference No. .................... : WTN21X10116492W-1 FCC ID ................................ : 2AU29AMPWSSUV2 Applicant ........................... : Turnils North America Address ............................. : 1750 Satellite Blvd, Suite 100, Buford GA 30518 Product Name ................... : Wall Switch Test Model. ........................ : 15C-Surface Mounted WS Standards .......................... : FCC Part 15.231 Date of Receipt sample .... : Oct. 29, 2021 Date of Test........................ : Oct. 29, 2021 to Jan. 20, 2022 Date of Issue ..................... : Jan. 20, 2022 Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Tested by: Reviewed By: Approved & Authorized By: Jack Huang / Project Engineer Jason Su / RF Manager Silin Chen / Manager Reference No.: WTN21X10116492W-1 Page 2 of 24 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn TABLE OF CONTENTS 1. GENERAL INFORMATION ................................................................................................................................... 4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ............................................................................... 4 1.2 TEST STANDARDS ................................................................................................................................................... 5 1.3 TEST METHODOLOGY ............................................................................................................................................. 5 1.4 TEST FACILITY ....................................................................................................................................................... 5 1.5 EUT SETUP AND TEST MODE ................................................................................................................................. 6 1.6 MEASUREMENT UNCERTAINTY .............................................................................................................................. 7 1.7 TEST EQUIPMENT LIST AND DETAILS ..................................................................................................................... 8 2. SUMMARY OF TEST RESULTS ......................................................................................................................... 10 3. ANTENNA REQUIREMENT ................................................................................................................................ 11 3.1 STANDARD APPLICABLE ....................................................................................................................................... 11 3.2 TEST RESULT........................................................................................................................................................ 11 4. RADIATED EMISSIONS ....................................................................................................................................... 12 4.1 STANDARD APPLICABLE ....................................................................................................................................... 12 4.2 TEST PROCEDURE ................................................................................................................................................. 13 4.3 CORRECTED AMPLITUDE & MARGIN CALCULATION ............................................................................................ 14 4.4 SUMMARY OF TEST RESULTS/PLOTS .................................................................................................................... 14 5. 20DB BANDWIDTH ............................................................................................................................................... 18 5.1 STANDARD APPLICABLE ....................................................................................................................................... 18 5.1 TEST PROCEDURE ................................................................................................................................................. 18 5.2 SUMMARY OF TEST RESULTS/PLOTS .................................................................................................................... 18 6. TRANSMISSION TIME ......................................................................................................................................... 19 6.1 STANDARD APPLICABLE ....................................................................................................................................... 19 6.2 TEST PROCEDURE ................................................................................................................................................. 19 6.3 SUMMARY OF TEST RESULTS/PLOTS .................................................................................................................... 19 7. DUTY CYCLE ......................................................................................................................................................... 21 7.1 STANDARD APPLICABLE ....................................................................................................................................... 21 7.2 TEST PROCEDURE ...................................................................................................................................…
Text truncated - open the document above for the full version.
Reference No.: WTN21X10116492W-1 Page 10 of 11 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn EXHIBIT 4 - TEST SETUP PHOTOGRAPHS Radiation Emission Test Setup (Below 30MHz) Radiation Emission Test Setup (30MHz to 1GHz) Reference No.: WTN21X10116492W-1 Page 11 of 11 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Radiation Emission Test Setup (1GHz to 18GHz) ***** END OF REPORT *****
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |
Smart Hub
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterSmith & Noble Smart Hub
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterAMP Bridge
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
DC Tubular Motor with built-in RF control
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
DC Tubular Motor for Narrow Shades
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter