FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Therabody, Inc./
  3. 2AU6T-TRM

2AU6T-TRMThermFace Massage

Therabody, Inc.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 21, 2026
Application Purpose
Original Equipment
Equipment Note
ThermFace Massage
Frequency Range
2402.00000000 - 2480.00000000
Company
Therabody, Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Therabody, Inc. Address: 1640 S. Sepulveda Blvd Suite 300 Los Angeles California United States 90025 Tel: 0086-13798236661 Fax: 0755-8676 7555 Email: [email protected] Attestation letter Date: 2026-06-29 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir or Madam, Our product ThermFace Massage, model: ThermFace Massage, FCC ID: 2AU6T-TRM, for marketing purpose, this product only supports BLE 1M: 2402-2480MHz. The other functions, bands and modes were disabled to use by manufacturer in the software, the end user has no capability to activate it. Sincerely Yours, Signature: Felix Chen Title: Compliance Manager

Attestation Statements

Therabody, Inc. Address: 1640 S. Sepulveda Blvd Suite 300 Los Angeles California United States 90025 Tel: 0086-13798236661 Fax: 0755-8676 7555 Email: [email protected] CFR 47 §2.911(d)(5)(i) Attestation Letter Attestation Letter Date: 2026-06-29 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID:2AU6T-TRM Therabody, Inc. certifies that the equipment for which authorization is sought, is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely Yours, Signature: Felix Chen Title: Compliance Manager

Attestation Statements

Therabody,Inc. Address:1640S.SepulvedaBlvdSuite300LosAngelesCaliforniaUnitedStates90025 Tel:0086-13798236661 Fax:0755-86767555 Email:[email protected] CFR47§2.911(d)(5)(ii)AttestationLetter AttestationLetter Date:2026-06-29 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsCFR47§2.911(d)(5)(ii)Filing FCCID:2AU6T-TRM Therabody,Inc.certifiesthatasofthedateofthefilingoftheapplication,theapplicantisnot identifiedontheCoveredListasanentityproducing“covered”equipment.Andourproductdoes notuseKasperskysoftwareinformation. Wealsocertifythat,asofthedateofthefilingoftheapplication,theequipmentdoesnotutilize cyber-securityoranti-virussoftwarefromKasperskyLab,Inc,oranyofitssuccessorsand assignees,whichisalsoonthe“coveredlist”. SincerelyYours, Signature: FelixChen Title:ComplianceManager

Attestation Statements

U.S.AGENTLETTEROFATTESTATION Date:2026-06-29 FEDERALCOMMUNICATIONSCOMMISSION AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsCFR47§2.911(d)(7)Filing FCCID:2AU6T-TRM Therabody,Inc.certifiesthat,asofthedateofthefilingoftheapplication,Therabody,Inc. isourdesignatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. Therabody,Inc.acceptstomaintainanagentfornolessthanoneyearafterthegranteehas terminatedallmarketingandimportationortheconclusionofanyCommission-related proceedinginvolvingtheequipment. Therabody,Inc.accepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentandApplicantInformation: Name:Therabody,Inc. Address:1640S.SepulvedaBlvdSuite300LosAngelesCaliforniaUnitedStates90025 FRN:0032704413 Tel.:0086-13798236661 Email:[email protected] Signedby(printedname):FelixChen Signature: Title:ComplianceManager

Cover Letter(s)

QA-FR-170-B Therabody,Inc. Address:1640S.SepulvedaBlvdSuite300LosAngelesCaliforniaUnitedStates90025 Tel:0086-13798236661 Fax:0755-86767555 Email:[email protected] FCCAuthorization Date:2026-06-29 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorization Towhomitmayconcern: We(Therabody,Inc.),theundersigned,herebyauthorizeBayAreaCompliance LaboratoriesCorp.(Shenzhen)toactonitsbehalfinallmattersrelatingtoapplication forEquipmentauthorization,includingthesigningofalldocumentsrelatingtothese matters.AllactscarriedoutbyBayAreaComplianceLaboratoriesCorp.(Shenzhen) onourbehalfshallhavethesameeffectasourownaction. We,theundersigned,herebycertifythatwearenotsubjecttoadenialoffederalbenefits, thatincludesFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988, 21U.S.C.862. Thisauthorizationisvaliduntilfurtherwrittennoticefromtheapplicant. SincerelyYours, Signature: FelixChen Title:ComplianceManager

Cover Letter(s)

Therabody,Inc. Address:1640S.SepulvedaBlvdSuite300LosAngelesCaliforniaUnitedStates90025 Tel:0086-13798236661 Fax:0755-86767555 Email:[email protected] FCCConfidentialAuthorization Date:2026-06-29 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestregardingapplicationforcertificationof FCCID:2AU6T-TRM InaccordancewithSections0.457and0.459oftheCommission’sRules,Therabody, Inc.herebyrequestslong-termconfidentialtreatmentofinformationaccompanyingthis applicationasoutlinedbelow: BlockDiagram Schematics OperationDescription Aswellasshort-termconfidentialtreatmentofinformationaccompanyingthis applicationforaperiodof180daysaftergrantisissuedasoutlinedbelow: InternalPhotos User’sManual ExternalPhotos TestSet-upPhotos Theabovematerialscontainproprietaryandconfidentialinformationnotcustomarily releasedtothepublic.Thepublicdisclosureofthesematerialsprovidesunjustified benefitstoitscompetitorsinthemarket. SincerelyYours, Signature: FelixChen Title:ComplianceManager

ID Label/Location Info

FCC ID:2AU6T-TRM IC:25672-TRM 上海强锐康国际贸易有限公司 Made in China Label and label location

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601T57664E-RFA TR-EM-RF011 Page 29 of 66 Version 4.2 RF EXPOSURE EVALUATION RF EXPOSURE EVALUATION Applicable Standard According to FCC §2.1093 and §1.1307(b) (1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D01 General RF Exposure Guidance v06. The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] • [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where 1. f(GHz) is the RF channel transmit frequency in GHz. 2. Power and distance are rounded to the nearest mW and mm before calculation. 3. The result is rounded to one decimal place for comparison. 4. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test Exclusion. Measurement Result For worst case: Mode Frequency (MHz) Max tune-up conducted power # (dBm) Max tune-up conducted power # (mW) Distance (mm) Calculated value Threshold (1-g SAR) SAR Test Exclusion BLE2402-24804.52.85.00.93.0Yes Result: Compliant

Test Report

Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF011 Page 1 of 66 Version 4.2 TEST REPORT Applicant Name:Therabody, Inc. Address:FCC: 1640 S. Sepulveda Blvd Suite 300 Los Angeles California United States 90025 IC: 1640 S. Sepulveda Blvd., Suite 300 Los Angeles CA 90025 United States Of America (Excluding The States Of Alaska Report Number:2601T57664E-RFA FCC ID:2AU6T-TRM IC:25672-TRM Test Standard (s) FCC PART 15.247; RSS-GEN ISSUE 5, FEBRUARY 2021 AMENDMENT 2; RSS-247 ISSUE 4, JULY 2025 Sample Description Product Type:ThermFace Massage Model No.:ThermFace Massage Multiple Model(s) No.:N/A Trade Mark:Therabody Date Received:2026-05-12 Issue Date:2026-08-18 Test Result:Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By:Approved By: Cheeb HuangJimmy Xiao RF EngineerEMC Manager Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601T57664E-RFA TR-EM-RF011 Page 2 of 66 Version 4.2 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ..........................................................................................................................3 GENERAL INFORMATION ........................................................................................................................................4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)......................................................................................4 OBJECTIVE ....................................................................................................................................................................4 TEST METHODOLOGY....................................................................................................................................................4 MEASUREMENT UNCERTAINTY .....................................................................................................................................5 TEST FACILITY ..............................................................................................................................................................5 SYSTEM TEST CONFIGURATION ...........................................................................................................................6 SUMMARY OF TEST RESULTS ................................................................................................................................9 TEST EQUIPMENT LIST ..........................................................................................................................................10 REQUIREMENTS AND TEST PROCEDURES ......................................................................................................12 AC LINE CONDUCTED EMISSIONS...............................................................................................................................12 UNWANTED EMISSION FREQUENCIES AND RESTRICTED BANDS .................................................................................15 99% OCCUPIED BANDWIDTH & 6 DB EMISSION BANDWIDTH ....................................................................................18 PEAK OUTPUT POWER MEASUREMENT .......................................................................................................................21 POWER SPECTRAL DENSITY ........................................................................................................................................22 100 KHZ BANDWIDTH OF FREQUENCY BAND EDGE....................................................................................................24 CONDUCTED SPURIOUS EMISSION...............................................................................................................................26 DUTY CYCLE ...............................................................................................................................................................28 RF EXPOSURE EVALUATION ................................................................................................................................29 ANTENNA REQUIREMENT .....................................................................................................................................32 TEST DATA AND RESULTS .....................................................................................................................................34 AC LINE CONDUCTED EMISSIONS...............................................................................................................................34 UNWANTED EMISSION FREQUENCIES AND RESTRICTED BANDS .................................................................................37 RF CONDUCTED DATA ................................................................................................................................................57 6dB Emission Bandwidth.................................................................................…

Text truncated - open the document above for the full version.

Test Report

ShenzhenElinkThingsCo.,Ltd -1- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 AntennaSpecification Version:V2.3 UpdateDate:September06,2023 ShenzhenYilianInternetofThingsCo.,Ltd.Allrights reserved Thespecificationsofthisproductaresubjecttochangewithoutnotice. ShenzhenYilianInternetofThingsCo.,Ltd.reservestherighttomakechangestothespecifications andmaterialscontainedinitwithoutpriornotice,andatthesametimedamage(includingconsequential damage)causedbytrustinthematerialscited,includingButnotlimitedtoerrorsinprintingandother errorsrelatedtothispublication,YilianInternetofThingswillnotbeheldresponsible. ShenzhenElinkThingsCo.,Ltd -1- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 Contents Contents...................................................................................................................................................................................-1- 1Antennasize(Unit:mm).................................................................................................................................................-1- 2Antennaspecificationparameters........................................................................................................................................-2- 3Testcondition........................................................................................................................................................................-2- 4Testingenvironment..............................................................................................................................................................-4- 5Deoningfrequencyofantennanetwork...............................................................................................................................-6- 6Antennatestefficiency.........................................................................................................................................................-6- 72Dfig(2450MHz)...................................................................................................................................................................-7- 83Dfig.....................................................................................................................................................................................-8- ShenzhenElinkThingsCo.,Ltd -1- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 1Antennasize ( Unit : mm ) BM16 ShenzhenElinkThingsCo.,Ltd -2- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 2Antennaspecificationparameters numberParameteritemDescription 1Centeroperatingfrequency2441MHz 2Workbandwidth2400---2480Mhz 3Rateofdatasignalling1Mbps 4AntennatypeOn-boardPCBantenna(default) 5Antennagain-1.08dBi 6Impedance50ohm 7ModemtypeGFSK 3Testcondition TestengineerJesseGuan Phone(+86)18975824147 [email protected] ConfirmJoyZhu Date2023/9/5 ShenzhenElinkThingsCo.,Ltd -3- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 ShenzhenElinkThingsCo.,Ltd -4- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 4Testingenvironment ShenzhenElinkThingsCo.,Ltd -5- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 ShenzhenElinkThingsCo.,Ltd -6- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 5Deoningfrequencyofantennanetwork Thereturnlossoftheantennaat2.445ghzis-30dBandtheimpedanceisabout50.Bandwidth80m 6Antennatestefficiency passivetestfor2.4g Freq(MHz)Gain(dBi)Efficiency(dB)Efficiency(%) 2400-2.125670268-6.51298217822.32039018 2410-1.839793728-6.35055515823.17098436 2420-1.64029678-6.24681065523.7311582 2430-1.328848956-5.92515296425.5555189 2440-1.132319256-5.79955308526.30538676 2450-1.087960046-5.84929926526.00579133 2460-1.316358881-6.00672172325.08001707 2470-1.579335991-6.24506749923.74068524 2480-1.962892418-6.45421219322.62448909 ShenzhenElinkThingsCo.,Ltd -7- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 2490-2.50538583-6.75344940721.11811056 2500-3.031894388-7.25223622418.8267943 72Dfig(2450MHz) (1)XY-Plane (2)ZY-Plane (3)ZX-Plane 3 1 2 ShenzhenElinkThingsCo.,Ltd -8- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 83Dfig

Contact Information

Applicant

Felix Chen
[email protected]Fax: 0755-8676 7555

Technical Contact

Therabody, Inc.Felix Chen
[email protected]

1640 S. Sepulveda Blvd Suite 300 · Los Angeles, California, 90025 · United States

Test Firm

Bay Area Compliance Laboratories Corp (Shenzhen)Nana Liu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.50 mW
Confidentiality
Long Term
Grant Notes
Output Power Listed is Conducted.

Other Applications from Therabody, Inc.

2AU6T-RA4M

JetBoots PRO Plus

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System
2AU6T-RA4D

JetBoots PRO Plus

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System
2AU6TTMP

Theragun Prime PLUS

Jul 07, 2024

Equipment Class

DTS - Digital Transmission System
Theragun PRO PLUS - FCC ID 2AU6TTPP - Therabody, Inc.
2AU6TTPP

Theragun PRO PLUS

Jul 27, 2023

Equipment Class

DTS - Digital Transmission System
Beauty Device - FCC ID 2AU6THALO-001 - Therabody, Inc.
2AU6THALO-001

Beauty Device

Jun 06, 2021

Equipment Class