Document Name User Manual Document No. TG-TPP-001 Model Theragun PRO PLUS Rev 01 Page 1 of 24 User Manual Name Date Prepared by: Ice Zheng Reviewed by: Felix Chen Approve by: CJ Frederick Revision History Modification date Change description Rev Modified by 2023-4-24 Initial release. 1 Team Document Name User Manual Document No. TG-TPP-001 Model Theragun PRO PLUS Rev 01 Table of Content 1. Recommendation of Use.............................................................................................. 3 1.1 Contraindications ............................................................................................... 4 1.2 Warnings ............................................................................................................ 5 1.3 Precautions ........................................................................... 1.5 Label & Symbols..................................................................................................... 9 2. Intended Use & Indications for Use ............................................................................ 10 3. Device Description ...................................................................................................... 10 3.1 Smart Features ................................................................................................ 11 3.2 Attachments ..................................................................................................... 11 3.3 Getting started ................................................................................................. 12 3.4 Using the Theragun PRO PLUS ................................................................. 13 3.5 Connecting the attachments ............................................................................ 14 3.6 Charging the Theragun PRO PLUS ............................................................ 14 4. Cleaning Instructions ................................................................................................... 16 5. Service ........................................................................................................................ 16 6. Product Specification .................................................................................................. 17 7. Safety, EMC ................................................................................................................ 18 8. Manufacturer Information ............................................................................................ 24 9. LIMITED WARRANTY ................................................................................................. 24 ............ ............ 6 Page 2 of 24 Document Name User Manual Document No. TG-TPP-001 Model Theragun PRO PLUS Rev 01 Page 3 of 24 1. Recommendation of Use Device name :Theragun PRO PLUS model : Theragun PRO PLUS Read the full Warnings and Guidance prior to using the Theragun PRO PLUS. The Theragun THE DEVICE is equipped with 5 buttons and a color LCD screen, which acts as the main user interface between user and device. These are located on the top of the device’s head in front of the top handle. This allows the user to view the screen while controlling the device with a single hand in most scenarios. The second point of interaction is the attachments. Users can change the therapy the device provides by replacing these accordingly (Percussive, Cold, Heat and Vibration at the moment of Launch). The attachments need to be physically changed by pulling from them. The third interfacing point is the biometric sensor, located in the interior of the main handle, and haptic system, located in the main and front handles. These two systems work as a conjunction to capture the user’s HR and HRV data and provide a physical feedback related to it (mimicking their own heart rate, a cyclic pattern to guide breathing, etc.) The haptic system is comprised of 4 ERM vibration motors that can be controlled independently in pairs. The last interface with the user will be the Therabody App. The THE DEVICE includes a Bluetooth chipset that enables the main functionalities of the product to be controlled via phone. Concurrently, the biometric data can be accessed by Therabody App in order to display the information to its user and provide recommendations based on it. The device was designed to be a “Recovery Hub”. Based on a percussive therapy device, the ergonomics of the triangular handle allows you to reach virtually any part of your body, but this time with a range of therapies beyond percussive (heat, vibration, Infrared light, cold). The LEDs providing the infrared light therapy are built in the device and can be used in conjunction with the rest of the therapies. The device will also be the first percussive therapy device with a built-in biometric sensor the reads your HR and HRV, and a haptic system (vibration motors inside the handles) that can provide different feedback depending on the Document Name User Manual Document No. TG-TPP-001 Model Theragun PRO PLUS Rev 01 Page 4 of 24 data. This device is contraindicated against and should not be used by those with acute or severe cardiac, liver, or kidney disease/condition or other underlying conditions linked to these diseases. It is not recommended that this device is used over various skin infections and conditions, or directly over a surgical site/hardware, bone fracture, or if you are experiencing unexplained pain in the area. It is also advised that this device is not used for those who have neurological and/or peripheral conditions as well as other conditions that may influence or alter sensation and perception. In the event of any adverse reaction, discontinue use. Please consult your physician prior to use if you are unsure if you have any of the previously listed conditions. Immediately stop using the device at the first sign of discomfort. Adult supervision should be provided for those under the age of 18 using this device. If you have an…
Text truncated - open the document above for the full version.
Therabody,Inc. Address:6100WilshireBlvd.Suite200LosAngeles,CA90048-5107,UnitedStates Tel:0086-13823630081 Fax:0755-86767555 Mail:[email protected] 2023-06-08 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Attestationletter DearSirorMadam, OurproductTheragunPROPLUS,model:TheragunPROPLUS, FCCID:2AU6TTPP,formarketingpurpose,thisproductonlysupportsBLE1M. Theotherfunctions,bandsandmodeswasdisabledtousebymanufacturerinthe software,theenduserhasnocapabilitytoactivateit. Sincerely, Signature: FelixChen Title:Manager
Therabody,Inc. Address:6100WilshireBlvd.Suite200LosAngeles,CA90048-5107,UnitedStates Tel:0086-13823630081 Fax:0755-86767555 Mail:[email protected] CFR47§2.911(d)(5)(i)AttestationLetter AttestationLetter Date:06/08/2023 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsCFR47§2.911(d)(5)(i)Filing FCCID:2AU6TTPP Therabody,Inc.certifiesthattheequipmentforwhichauthorizationissought,isnot“covered” equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903ofthe FCCrules. Sincerely, Signature ContactPerson:FelixChen Title:Manager
Therabody,Inc. Address:6100WilshireBlvd.Suite200LosAngeles,CA90048-5107,UnitedStates Tel:0086-13823630081 Fax:0755-86767555 Mail:[email protected] CFR47§2.911(d)(5)(ii)AttestationLetter AttestationLetter Date:06/08/2023 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsCFR47§2.911(d)(5)(ii)Filing FCCID:2AU6TTPP Therabody,Inc.certifiesthatasofthedateofthefilingoftheapplication,theapplicantisnot identifiedontheCoveredListasanentityproducing“covered”equipment. Sincerely, Signature ContactPerson:FelixChen Title:Manager
U.S.AGENTLETTEROFATTESTATION Date:2023-06-08 FEDERALCOMMUNICATIONSCOMMISSION AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsCFR47§2.911(d)(7)Filing FCCID:2AU6TTPP Therabody,Inc.certifiesthat,asofthedateofthefilingoftheapplication,Therabody,Inc. isourdesignatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. Therabody,Inc.acceptstomaintainanagentfornolessthanoneyearafterthegranteehas terminatedallmarketingandimportationortheconclusionofanyCommission-related proceedinginvolvingtheequipment. Therabody,Inc.accepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentandApplicantInformation: Name:Therabody,Inc. Address:6100WilshireBlvd.Suite200LosAngeles,CA90048-5107,UnitedStates FRN:0028992295 Tel.:0086-13823630081 Email:[email protected] Signedby(printedname):FelixChen Signature:
QA-FR-170-B Therabody,Inc. Address:6100WilshireBlvd.Suite200LosAngeles,CA90048-5107,UnitedStates Tel:0086-13823630081 Fax:0755-86767555 Mail:[email protected] FCCAuthorization Date:2023-06-08 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorization Towhomitmayconcern: We(Therabody,Inc.),theundersigned,herebyauthorizeShenzhenAccurateTechnology Co.,Ltd.toactonitsbehalfinallmattersrelatingtoapplicationforEquipment authorization,includingthesigningofalldocumentsrelatingtothesematters.Allacts carriedoutbyShenzhenAccurateTechnologyCo.,Ltd.onourbehalfshallhavethe sameeffectasourownaction. We,theundersigned,herebycertifythatwearenotsubjecttoadenialoffederalbenefits, thatincludesFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988, 21U.S.C.862. Thisauthorizationisvaliduntilfurtherwrittennoticefromtheapplicant. SincerelyYours, Signature: FelixChen Title:Manager
Therabody,Inc. Address:6100WilshireBlvd.Suite200LosAngeles,CA90048-5107,UnitedStates Tel:0086-13823630081 Fax:0755-86767555 Mail:[email protected] FCCConfidentialAuthorization Date:2023-06-08 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestregardingapplicationforcertificationof FCCID:2AU6TTPP InaccordancewithSections0.457and0.459oftheCommission’sRules,Therabody,Inc. herebyrequestslong-termconfidentialtreatmentofinformationaccompanyingthis applicationasoutlinedbelow: BlockDiagram Schematics OperationDescription Aswellasshort-termconfidentialtreatmentofinformationaccompanyingthis applicationforaperiodof180daysaftergrantisissuedasoutlinedbelow: InternalPhotos User’sManual ExternalPhotos TestSet-upPhotos Theabovematerialscontainproprietaryandconfidentialinformationnotcustomarily releasedtothepublic.Thepublicdisclosureofthesematerialsprovidesunjustified benefitstoitscompetitorsinthemarket. SincerelyYours, Signature: FelixChen Title:Manager
Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF External Photos Page 1 of 4 External Photos Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF External Photos Page 2 of 4 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF External Photos Page 3 of 4 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF External Photos Page 4 of 4
The E-label information To access the e-label information, in the device, Choose: Settings > Device
Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Internal Photos Page 1 of 13 Internal photos Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Internal Photos Page 2 of 13 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Internal Photos Page 3 of 13 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Internal Photos Page 4 of 13 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Internal Photos Page 5 of 13 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Internal Photos Page 6 of 13 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Internal Photos Page 7 of 13 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Internal Photos Page 8 of 13 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Internal Photos Page 9 of 13 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Internal Photos Page 10 of 13 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Internal Photos Page 11 of 13 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Internal Photos Page 12 of 13 Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Internal Photos Page 13 of 13 ANT
Shenzhen Accurate Technology Co., Ltd. Report No.: RA230525-29245E-RF Version 140: 2023-01-30 Page 12 of 51 FCC-BLE; RSS-BLE FCC§15.247 (i), §1.1307 (b) (3) &§2.1093 – RF EXPOSURE Applicable Standard According to FCC §2.1093 and §1.1307(b) (3), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D04 Interim General RF Exposure Guidance SAR-Based Exemption: SAR-based thresholds are derived based on frequency, power, and separation distance of the RF source. The formula defines the thresholds in general for either available maximum timeaveraged power or maximum time-averaged ERP, whichever is greater. Per § 1.1307(b)(3)(i)(B), for single RF sources (i.e., any single fixed RF source, mobile device, or portable device, as defined in paragraph (b)(2) of this section): A single RF source is exempt if: the available maximum time-averaged power or effective radiated power (ERP), whichever is greater, is less than or equal to the threshold P th (mW) described in the following formula. This method shall only be used at separation distances (cm) from 0.5 centimeters to 40 centimeters and at frequencies from 0.3 GHz to 6 GHz (inclusive). P th is given by: Shenzhen Accurate Technology Co., Ltd. Report No.: RA230525-29245E-RF Version 140: 2023-01-30 Page 13 of 51 FCC-BLE; RSS-BLE For worst case: Exemption limit: For f=2.48GHz, d=0.5cm, the P th =2.72mW For handheld use, the limit are multiplied by a factor of 2.5, so exemption limit=6.8mW The higher of the available maximum time-averaged power or effective radiated power (ERP): The antenna gain is -3dBi (-5.15dBd), 0dBd=2.15dBi The maximum tune up conducted power is 8.0dBm (6.31mW), which less than 6.8 mW@2480MHz exemption limit So the stand-alone SAR test can be exempted.
TestDate:2019.05.06 深圳市 地址:深圳市宝安区 67 区洪浪北二路凌云大厦 10 楼 Shenzhen Chuangke Zhiqu Communication Technology Co., Ltd. Adress: 10th Floor, Lingyun Building, Honglang North 2nd Road, District 67, Bao 'an District, Shenzhen www.RFsister.com 聚焦·开放·分享 天线测试报告 -RF sister Antenna test report Test Date : 2019.05.06 1.A n t e n n a s i z e TestDate:2019.05.06 聚焦·开放·分享 2. Electrical Characteristics No.ItemSpecifications 1 Frequency 2400-2500MHz 2 BandWidth 1 M 3 Max. Gain -3dbi 4 V.S.W.R(inBW) ≤4.3 5 PolarizationLinear 6 AzimuthBeamwidthOmni-directional 7 Impedance阻抗50 Return 3. ReturnLoss andSmithChat Loss TestDate:2019.05.06 聚焦·开放·分享 V.S.W.R SmithChat TestDate:2019.05.06 聚焦·开放·分享 4. Physical Test Environment E5071C网络分析仪 5. Shape of the antenna Efficiency : TestDate:2019.05.06 聚焦·开放·分享 2400MHz 2450MHz TestDate:2019.05.06 聚焦·开放·分享 2500MHz
★ Note: This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “ ”. Shenzhen Accurate Technology Co., Ltd. is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with an asterisk ’*’. Customer model name, addresses, names, trademarks etc. are not considered data. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. Shenzhen Accurate Technology Co., Ltd. 1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, P.R. China Tel: +86 755-26503290 Fax: +86 755-26503290 Web: www.atc-lab.com Version 140: 2023-01-30 Page 1 of 51 FCC-BLE; RSS-BLE TEST REPORT Applicant Name : Therabody, Inc. Address : FCC: 6100 Wilshire Blvd. Suite 200 Los Angeles, CA 90048- 5107, United States IC: 6100 Wilshire Blvd., Suite 200 Los Angeles CA 90048-5107 United States Of America (Excluding The States Of Alaska Report Number : RA230525-29245E-RF FCC ID: 2AU6TTPP IC: 25672-TPP Test Standard (s) FCC PART 15.247; RSS-GEN ISSUE 5, FEBRUARY 2021 AMENDMENT 2; RSS-247, ISSUE 2, FEBRUARY 2017 Sample Description Product Type: Theragun PRO PLUS Model No.: Theragun PRO PLUS Multiple Model(s) No.: N/A Trade Mark: Therabody Date Received: 2023/05/25 Report Date: 2023/06/13 Test Result: Pass* * In the configuration tested, the EUT complied with the standards above. Prepared and Checked By: Approved By: Dave Liang Candy Li EMC Engineer EMC Engineer Shenzhen Accurate Technology Co., Ltd. Report No.: RA230525-29245E-RF Version 140: 2023-01-30 Page 2 of 51 FCC-BLE; RSS-BLE TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 4 GENERAL INFORMATION ....................................................................................................................................... 5 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 5 OBJECTIVE ................................................................................................................................................................... 5 TEST METHODOLOGY .................................................................................................................................................. 5 MEASUREMENT UNCERTAINTY .................................................................................................................................... 6 SYSTEM TEST CONFIGURATION .......................................................................................................................... 7 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 7 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 7 EUT EXERCISE SOFTWARE .......................................................................................................................................... 7 DUTY CYCLE ................................................................................................................................................................ 8 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 8 EXTERNAL I/O CABLE .................................................................................................................................................. 8 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 8 SUMMARY OF TEST RESULTS ............................................................................................................................. 10 TEST EQUIPMENT LIST ......................................................................................................................................... 11 FCC§15.247 (I), §1.1307 (B) (3) &§2.1093 – RF EXPOSURE ..................................................................................... 12 APPLICABLE STANDARD ............................................................................................................................................ 12 RSS-102 § 2.5.1 - EXEMPTION LIMITS FOR ROUTINE EVALUATION – SAR EVALUATION ................. 14 APPLICABLE STANDARD ............................................................................................................................................ 14 FCC §15.203 & RSS-GEN §6.8 – ANTENNA REQUIREMENT............................................................................ 16 APPLICABLE STANDARD ............................................................................................................................................ 16 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 16 FCC §15.207 (A), RSS-GEN §8.8 - AC POWER LINE CONDUCTED EMISSIONS .......................................... 17 APPLICABLE STANDARD ............................................................................................................................................ 17 EUT SETUP ................................................................................................................................................................ 17 EMI TEST RECEIVER SETUP ..…
Text truncated - open the document above for the full version.
Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Test Photos Page 1 of 2 Photo of Conducted Emission Measurement Shenzhen Accurate Technology Co., Ltd. Project No.: RA230525-29245E-RF Test Photos Page 2 of 2 Photo of Radiated Emission Measurement (Below 1G) Photo of Radiated Emission Measurement (Above 1G)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 6.00 mW |
ThermFace Massage
Equipment Class
DTS - Digital Transmission SystemJetBoots PRO Plus
Equipment Class
DTS - Digital Transmission SystemJetBoots PRO Plus
Equipment Class
DTS - Digital Transmission SystemTheragun Prime PLUS
Equipment Class
DTS - Digital Transmission System
Beauty Device
Equipment Class
DTS - Digital Transmission System