Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Document Name User manual Document No. 003-HALO-TG Model Theragun halo Rev 40 1 Rev History Modification date Change description Rev Modified by 12-4-2021 Update intended use 3 Team 12-4-2021 Updated language and fixed minor errors 4 Team User Manual 2 Contents 1 Recommendation of Use 3 1.1Contraindications 4 1.2 Warnings 4 1.3 Precautions 6 1.4 Adverse Reactions 7 1.5 Label & Symbols 7 2 Intended Use & Indications for Use 7 3 Product Description 8 3.1 Detachable component List 10 3.2 Function Introduction 12 3.3 How to Operate the Theragun halo 12 3.3.1 Main device with attachment 13 3.3.3 Keyboard 14 3.3.4 Buttons icon 14 3.3.5 Using Instructions 16 3.3.6 APP instructions(ISO/Android) 19 4 Product specification 33 4.1 Switch off the device 34 4.2 Charging 34 5 Maintenance 35 5.1 Error! Bookmark not defined.35 5.2 Trouble Shooting 36 5.3 Disposal of Electrical and Electronic Equipment Waste (E-waste) 6 Service 36 7 Safety, EMC & Biocompatibility 37 8 Manufacturer Information 41 9 LIMITED WARRANTY 41 Document Name User manual Document No. 003-HALO-TG Model Theragun halo Rev 40 3 User Manual 4 1 Recommendation of Use 1.1 Contraindications It means that the device is unit for use in certain diseases, conditions, or specific populations. 1) Never use this device over any damaged tissue or other type of skin condition can result in delaying the best medical treatment. 2) Do not use if you have had any facial surgery or other surgical procedure – consult your doctor 3) Do not use if you have a history of epilepsy or seizures 4) Do not use if you are pregnant 5) Never use the device to the patient with Implant Electronic Devices (such as cardiac pacemaker) 6) The device should not be used in the following areas - Breast area - Eye area(circular muscle within the orbital rim) - Mid-line of neck (bone of neck) - Groin area 7. The ME EQUIPMENT shall not be serviced or maintained while in use with a PATIENT. 1.2 Warnings The patient is an intended operator. The patient can use and maintain the device and its accessories according to this manual It’s used to identify a hazard that may lead to death or serious injury. Do not apply over the eyeballs in the stimulation mode, otherwise will damage the eyes. People with a facial trauma are suggested to consult the doctor before using the Halo device. Document Name User manual Document No. 003-HALO-TG Model Theragun halo Rev 40 5 People who have had an aesthetic surgery or had Botox injections should consult the doctor before using, otherwise will cause physical damage. Do not use if you have had any facial surgery or other surgical procedure – consult with your doctor. Stop using when you have any discomfort. Use this device only for its intended use as described in this user manual and avoid causing physical damage. The device should not be used by children and pregnant women and should be kept out of the reach of children (0 to 12 years old). This product is not waterproof, only clean with a moist washcloth wipe the device .Don't put the device under water. Do not apply the device near any devices with Electromagnetic Interference (EMI), such as cell phones, Magnetic Resonance Imaging (MRI), computerized axial tomography (CT), diathermy, Radio Frequency Identification (RFID), etc. or MR environment. EMI, RF devices or MR environment may affect the normal function of the device or would cause user injury. The devise is for single patient use. For device with micro current stimulation mode: If you are being treated by a physician, consult with your physician before using this device. Do not apply the electrodes near the thorax; the application of electrodes near the thorax may increase the risk of cardiac fibrillation. Do not apply Micro current over your neck because this could cause severe muscle spasms resulting in closure of your airway, difficulty in breathing, or adverse effects on heart rhythm or blood pressure. Do not apply microcurrent across your chest because the introduction of electrical current into the chest may cause rhythm disturbances to your heart, which could be lethal. Do not apply stimulation over painful areas. If you have painful areas, you should consult with your physician before using this device. Do not apply stimulation over open wounds or rashes, or over swollen, red, infected, or inflamed areas or skin eruptions (e.g., phlebitis, thrombosis, varicose veins). Do not apply stimulation in the presence of electronic monitoring equipment (e.g., cardiac monitors, ECG alarms), which may not operate properly when the electrical stimulation device is in use. Commented [TP1]: Define “children” Commented [JS2]: Deleted for adult use only. Need to discuss User Manual 6 Simultaneous connection of a user to a high frequency surgical ME equipment may result in burns at the site of the simulator electrodes and possible damage to the simulator. Operation in close proximity (e.g.0. 1 m) to a shortwave or microwave therapy ME equipment may produce instability in the simulator output. Do not use the device in the shower. Do not apply stimulation while sleeping. Do not use the device on children under 12 years of age. Do not apply stimulation while driving, operating machinery, or during any activity in which electrical stimulation can put you at risk of injury. Consult with your physician before using this device, because the device may cause lethal rhythm disturbances to the heart in susceptible individuals. Apply stimulation only to normal, intact, clean, healthy skin. Keep clean in use, store in a dry place, do not expose to the sun This appliance contains batteries that are non-replaceable Avoid the LED light irradiate into your eyes when operate the device with LED ring; Otherwise it will cause eyes injury. During the light irradiation treatment, close your eyes to avoid the light beam get into your eyes. FCC compliance statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)…
Text truncated - open the document above for the full version.
Theragun,Inc. Date:2021-02-09 TO:FederalCommunicationCommission EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MID21046 Regarding:FCCID: 2AU6THALO-001 Towhomitmayconcern: We,theundersigned,herebyauthorizeSGS-CSTCStandardsTechnicalServicesCo.,Ltd.(SGS) ShenzhenBranchandKenyXuinSGS-CSTCStandardsTechnicalServicesCo.,Ltd.(SGS)Shenzhen Branchtoactonourbehalfinallmannersrelatingtoapplicationforequipmentauthorizationwithrespect totheFCCIDabove,includingsigningofalldocumentsrelatingtothesematters.Anyandallactscarried outbytheagentonourbehalfshallhavethesameeffectasactsofourown. We,theundersigned,herebycertifythatwearenotsubjecttoadenialoffederalbenefits,thatincludes FCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,21U.S.C.853(a). Whereouragentsignstheapplicationforcertificationonourbehalf,Iacknowledgethatallresponsibility forcomplyingwiththetermsandconditionsforCertification,asspecifiedbySGSNorthAmerica,Inc.,still resideswithTheragun,Inc. Thisauthorizationisvaliduntilfurtherwrittennoticefromtheapplicant. PrintName:FelixChenTitle:ComplianceEngineer Signature: OnbehalfofCompany:Theragun,Inc. Telephone:0086+13823630081 E-mail:[email protected]
Theragun, In c. Date :2021-02-09 TO: Federal Communicati on Commission Equipment Authorizati on Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding:Confidentiality Request regarding application for FCC ID: 2AU6THALO-001 LONG TERM CONFID ENTIA LIT Y Pursuant to 47 CFR Secti on 0.4 59 and 0.4 57 of th e commission’s rules, th e applicant hereby request confidenti al tr eatm ent of th e documents liste d below, associate d with th e certi ficati on applicati on referenced above. Schemati c(s) Block Diagrams Operati onal Descripti ons The documents above conta in proprietary informati on not released to th e public. Public disclosure of th is informati on may prove harmful to th e business of th e applica nt. SHORT TERM CONFID ENTIA LIT Y Additi onally, th e applicant requests th e fo llowing documents be held confidenti al unti l th e device is markete d or180days fr om th e grant date , whichever is less. If th e device is markete d with in aforementi oned days of th e Grant Date , th e applicant will noti fy th e TCB per FCC KDB 726920 D01 Confidenti ality Request Procedures. Exte rnal Photo s In te rnal Photo s Test Setup Photo s User manual(s) Sincerely, Print Name: Felix ChenPrint Name: Felix Chen Signatu re: On behalf of Company: Theragun, In c. Telephone: 0086+13823630081 E-mail:felix.c he n@the rabodycorp.c om
ApplicantDeclaration ApplicantDeclaration Rev:0.0 SGSNorthAmericaInc. 620OldPeachtreeRoad SUITE100 Suwanee,Georgia30024 UnitedStates ApplicantLegalBusinessName Theragun,Inc. Address 6100WilshireBlvd.Suite200LosAngeles,CA90048-5107,USA GranteeCode 2AU6T FCCID 2AU6THALO-001 AuthorizedContactName FelixChen ContactEmail [email protected] ContactPhone 0086+13823630081 I,theundersigned,certifythatIamanauthorizedsignatoryfortheApplicantandthereforedeclare; a)inaccordancewith47CFR2.911(d),allofthestatementshereinandtheexhibitsattachedheretoaretrueandcorrecttothebestofmy knowledgeandbelief. b)inacceptingaGrantofEquipmentAuthorizationissuedbyaTCB,undertheauthorityoftheFCC,asaresultoftherepresentationsmadein thisapplication,theApplicantisresponsiblefor: (1)labelingtheequipmentwiththeexactFCCIDasspecifiedinthisapplication, (2)compliancestatementlabelingpursuanttotheapplicablerules, (3)complianceoftheequipmentwiththeapplicabletechnicalrules, c)iftheApplicantisnottheactualmanufactureroftheequipment,appropriatearrangementshavebeenmadewiththemanufacturertoensure thatproductionunitsofthisequipmentwillcontinuetocomplywiththeFCC’stechnicalrequirements. d)inaccordancewith47CFR2.909andKDB394321,theApplicanthasread,understoodandagreestoacceptthattheyaretheresponsible partyandagreetoabidebytheirresponsibilitiesasspecifiedunder47CFR2.909andKDB394321. e)inaccordancewithISO17065,FCCKDB641163,FCCKDB610077,KDB394321andRSP-100,theApplicanthasread,understood,accepts andagreestoabidebythepostmarketsurveillancerequirements. (1)theApplicantunderstands,acceptsandagreesthatasamplemayberequestedforsurveillancetesting. (2)theApplicantshallmakeprovisionstoalwayshaveaproductionsampleavailableuponrequestbySGS,FCCand/orISED. (3)theApplicantshall,uponrequestbySGS,attheApplicant’sexpense,provideaproductionsampleoftherequestedproducttoSGS, FCCand/orISEDasinstructed.Thesampleshallincludeallsupportdevices,cables,software,accessoriesorotherhardwareor softwarerequiredforevaluation,review,certificationandauditsurveillanceofproductscertifiedbySGS. f)neithertheApplicantnoranypartytotheapplicationissubjecttoadenialofFederalbenefits,thatincludesFCCbenefits,pursuanttoSection 5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862becauseofaconvictionforpossessionordistributionofacontrolledsubstance.See 47CFR1.2002(b)forthedefinitionofa“party”forthesepurposes. g)theApplicanthasread,understood,acceptsandagreestoabidebytheSGSNorthAmerica,Inc.(TCB)termsandconditions. LinktoCFRs:https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 LinktoKDBs:https://apps.fcc.gov/oetcf/kdb/index.cfm LinktoRSP-100:https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html ApplicantSignature:Date: PrintName:FelixChen Title:ComplianceTeam *NOTE:ThisdeclarationcannotbesignedbyanAgent,itshallbesignedbyanauthorizedpersonlistedintheFCCdatabase
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 6 External Photos for SZEM2102001753CR FCC ID: 2AU6THALO-001 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 6 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 6
Considering the limited space of product label, it is not convenient to add FCC Part 15a(3) statement in other locations, we(Theragun, Inc.) have add this statement in the manual to replace. Label Location: Label position at the top of the handle.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 9 Internal Photos for SZEM2102001753CR FCC ID: 2AU6THALO-001 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 9 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 7 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 8 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 9 of 9
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210200175302 Page: 1 of 6 Keny Xu EMC Laboratory Manager 1 Cover page SAR Evaluation Report Application No.: SZEM2102001753CR Applicant: Theragun, Inc. Address of Applicant: 6100 Wilshire Blvd. Suite 200 Los Angeles, California, 90048-5107, United States Manufacturer: Theragun, Inc. Address of Manufacturer: 6100 Wilshire Blvd. Suite 200 Los Angeles, CA 90048-5107, USA Factory: Shenzhen Xiang Zhida Technology Co., Ltd Address of Factory: Room 101, 201, 301, 401, Building C, No.121 of Lianxin Road, Wulian Community, Longgang Street, Longgang District, Shenzhen, P.R.C Equipment Under Test (EUT): EUT Name: Beauty Device Model No.: TheraFace Trade mark: TheraFace FCC ID: 2AU6THALO-001 Standards: 47 CFR Part 1.1307 47 CFR Part 2.1093 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2021-02-09 Date of Test: 2021-02-14 to 2021-03-08 Date of Issue: 2021-03-26 Test Result : PASS* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210200175302 Page: 2 of 6 2 Version Revision Record Version Chapter Date Modifier Remark 01 2021-03-26 Original Authorized for issue by: Leo Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210200175302 Page: 3 of 6 3 Contents Page 1 COVER PAGE ........................................................................................................................................ 1 2 VERSION ................................................................................................................................................ 2 3 CONTENTS ............................................................................................................................................ 3 4 GENERAL INFORMATION ..................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 4 4.2 TEST LOCATION ................................................................................................................................ 5 4.3 TEST FACILITY .................................................................................................................................. 5 4.4 DEVIATION FROM STANDARDS ............................................................................................................ 5 4.5 ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................... 5 4.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER .......................................................................... 5 5 SAR EVALUATION ................................................................................................................................. 6 5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ........................................................................................ 6 5.1.1 Standard Requirement ................................................................................................................ 6 5.1.2 Limits .......................................................................................................................................... 6 5.1.3 EUT RF Exposure ....................................................................................................................... 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210200175302 Page: 4 of 6 4 General Information 4.1 General Description of EUT Power supply: Lithium Ion Battery: 7.4V 5.6Wh rechargeable battery which charged by USB port Cable(s): Type-C cable:46cm unshielded Operation Frequency: 2402MHz to 2480MHz Bluetooth Version: V4.2 LE Modulation Type: GFSK Number of Channels: 40 Channel Spacing: 2MHz Antenna Type: PCB Antenna Antenna Gain: 1.5dBi SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210200175302 Page: 5 of 6 4.2 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 No tests were sub-contracted. 4.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized by ISED as an accredited testing laboratory. CAB identifier: CN0006. IC#: 4620C. 4.4 Deviation from Standards None. 4.5 Abnormalities from Standard Conditions None. 4.6 Other Information Requested by the Customer None. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210200175302 Page: 6 of 6 5 SAR Evaluation 5.1 RF Exposure Compliance Requirement 5.1.1 Standar…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210200175301 Page: 1 of 49 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZEM2102001753CR Applicant: Theragun, Inc. Address of Applicant: 6100 Wilshire Blvd. Suite 200 Los Angeles, California, 90048-5107, United States Manufacturer: Theragun, Inc. Address of Manufacturer: 6100 Wilshire Blvd. Suite 200 Los Angeles, CA 90048-5107, USA Factory: Shenzhen Xiang Zhida Technology Co., Ltd Address of Factory: Room 101, 201, 301, 401, Building C, No.121 of Lianxin Road, Wulian Community, Longgang Street, Longgang District, Shenzhen, P.R.C Equipment Under Test (EUT): EUT Name: Beauty Device Model No.: TheraFace Trade Mark: TheraFace FCC ID: 2AU6THALO-001 Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2021-02-09 Date of Test: 2021-02-14 to 2021-03-08 Date of Issue: 2021-03-26 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210200175301 Page: 2 of 49 Revision Record Version Chapter Date Modifier Remark 01 2021-03-26 Original Authorized for issue by: Leo Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210200175301 Page: 3 of 49 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions ANSI C63.10 (2013) Section 6.4,6.5,6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM210200175301 Page: 4 of 49 3 Contents Page 1 COVER PAGE ..................................................................................................................................... 1 2 TEST SUMMARY ................................................................................................................................. 3 3 CONTENTS ......................................................................................................................................... 4 4 GENERAL INFORMATION .................................................................................................................. 6 4.1 DETAILS OF E.U.T. ......................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS .................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY ......................................................................................................... 6 4.4 TEST LOCATION ............................................................................................................................. 7 4.5 TEST FACILITY ............................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ......................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................. 7 5 EQUIPMENT LIST ............................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................11 6.1 ANTENNA REQUIREMENT ................................................................................................................11 6.1.1 Test Requirement: ..................................................................................................................11 7 RADIO SPECTRUM MATTER TEST RESULTS .................................................................................12 7.1 CONDUCTED PEAK OUTPUT POWER ................................................................................................12 7.1.1 E.U.T. Operation .....................................................................................................................12 7.1.2 Test Mode Description ............................................................................................................12 7.1.3 Test Setup Diagram ................................................................................................................13 7.1.4 Measurement Procedure and Data .........................................................................................13 7.2 MINIMUM 6DB BANDWIDTH .............................................................................................................14 7.2.1 E.U.T. Operation .....................................................................................................................14 7.2.2 Test Mode Description ............................................................................................................14 7.2.3 Test Setup Diagram ............................................................................................................…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 3 Setup Photos for SZEM2102001753CR FCC ID: 2AU6THALO-001 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 3 1 Photographs Radiated Emissions which fall in the restricted bands Radiated Spurious Emissions SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 3
No.1 Workshop, M-10, Middle Section, · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 400.00 µW |
ThermFace Massage
Equipment Class
DTS - Digital Transmission SystemJetBoots PRO Plus
Equipment Class
DTS - Digital Transmission SystemJetBoots PRO Plus
Equipment Class
DTS - Digital Transmission SystemTheragun Prime PLUS
Equipment Class
DTS - Digital Transmission System
Theragun PRO PLUS
Equipment Class
DTS - Digital Transmission System